| Sl. No. | Item Description |
| 1 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked)of size 95 Sqmm 3.5 Core& laid in trenches/pipes or fixed on pole Complete all as per specified and directed by Engg-in-Charge. |
| 2 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation etc or for laying of cables, pipes etc and getting out in soft/loose soil complete all as specified. |
| 3 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed by engineer-in-charge |
| 4 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick. |
| 5 | M&L for tibba sand cushioning to under ground cable in trenches/existing cabletrenches/ducts in layers of 8cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge |
| 6 | M&L Stone patti 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35 cm wide and not less then 60 cm in length laid dry abutting each other with gap between adjacent slab not excedding 10mm over sand cushioning complete all as specified and directed |
| 7 | Supply and erecting cable route marker for LT Cable made of precast RCC (1:2:4) using 20mm graded stone aggregate cast in pillar of size 15x10x60cm including reinforcement with 4 nos 10mm dia deframed bars of 55 cm length and link/strapps of 8mm dia bras at 150mm C/C and in fixing in ground level duly pained &written LT .433 KV including PCC & earth work |
| 8 | M&L for GI Tubes, of size 40mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. |
| 9 | M&L for GI Tubes, of size 50mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. |
| 10 | M&L for GI Tubes, of size 80mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. |
| 11 | Boring of Holes under road,Pavement,hard,standing by trenchless technology using ultra sounding techanique and necessary machine including HDPE pipe of 300 mm dia for 0.4 mpa working pressure |
| 12 | PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work compaction etc all as specfied and directed by Engineer-in-Charge. |
| 13 | Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Copper bus bar for distribution system and type tested at CPRI, complete with bus bars and control wiring complete including dismantling of old LT panel and including the following, LT panel 1INCOMING :(a) On load change over switch, 415 Volts, 50 Hz, 4 pole - 01 Nos(b) MCCB 100 Amps, 4 pole , Thermal magneticrelease, 16 KAadjustable 70 to 100%, 415 Volts, 50 Hz-01 NosOUTGOINGS : (a)MCCB 100 Amps, 4 pole , Thermal magneticrelease, 16 KAadjustable 70 to 100%, 415 Volts, 50 Hz-02 Nos |
| 14 | Supply, install, testing and Commissioning of APFC Panel of capacity 25 KVAR with relay 05 step auto/manual operation suitable for improving PF up to unity Double door Outdoor type CPRI Approved hut type top made out of 3 mm thickness CRCA sheet with channel / angle iron pedestral frame, compartmental type , dust free, vermin proof , IP 52 protection cable alley , cable entry hole at the bottom and mounting on ISMC 100 Channel duly grouted on in and includingPCC (1:3:6) platform raised at 30 cm above Ground level Suitable for comprising and provision of the following Accessories :-(a) Incommer MCCB 4 pole 415 volts with Adjustable type 100 Amps with breaking capacity 36 KA complete -01 Nos(b) Bus bar aluminimum of suitable capacity for phases and neutral -01 Set. (c) Capacitor duty contactor of MO C type of required capacity - 01 Nos (for each capacitor bank) (d)Digital Micro processor based power factor correction Relay of suitable step operation suitable for 25 KVAR capacity of APFC panel- 01 Nos (e) 25 KVAR capacitor bank consisting of 5 Steps of operation including of Capacitors of voltage 450V long lifeheavy dutytype5 x 05 KVAR with suitable MCCB as back up protection.(f) 5 KVAR fixed heavy duty type capacitor(f)DigitalAmmeter with selector switch and CTs of suitable capacity.(g)Digital Voltmeter with selector switch of suitable capacity.(h) Internal power and control wiring with suitable size of PVC insulated copper wire and LED indicating lamps.. |
| 15 | Supply, installation, testing, and commissioning of a 50 kVA Isolation Transformer, 3-Phase, 50 Hz, outdoor Type, Copper Wound, Oil Cooled, with Class \"A\" Insulation and a powder-coated metallic body, designed for an Input Voltage range of 415V ±5% and an Output Voltage range of 415V +5%, with a 1:1 ratio and Vector Group Dyn 11 (Delta-Star) configuration. The transformer shall include the first filling of transformer oil of requisite dielectric strength up to the prescribed level, ensuring an efficiency of more than 95%. A separate neutral bushing shall be provided for earthing, maintaining a potential difference between neutral and earth of less than one volt. The transformer shall be equipped with standard fittings, including a digital temperature meter, lifting hooks (one set), and two earthing terminals, ensuring safe and efficient operation. Protection features include Overload and Short Circuit Protection, ensuring reliability and longevity complete all as specifed and directed. Note : 1.Isolation transformer shall be supplied with First fill of transformer oiland cost of the same is deemed to be included in unit quoted rates.2.Plateform of suitable sizefor mounting of isolation transformer shall be provided by the contractort as per manufacturers advise and the cost of the same shall be deemed to be included in unit quoted rates.Make- Volina, ITE Gurgaon, Vinteck |
| 16 | Supply, Installation, Commessioning and Testing of50 kVA Servo Controlled Voltage Stabilizer, copper wound, confirming to BIS: 9815: Part 1: 1994 (Re-affirmed 2019),3-phase, 4 wire, 50Hz, Naturally Oil Cooled, outdoor type, Unbalanced Type, Copper Wound unit with a Digital Display, ensuring Relay-Free, Smooth, and Silent Operation with first filling ofTransformer Oil (IS 335:2018). It operates within an Input Voltage range of 300V-480V, providing a stable Output Voltage of 415V ±1% (Adjustable) at 50 Hz frequency with no wave form distortion and a response time of ≤10 milli seconds. It has a sensitivity of ±1%, a correction rate of >6V/sec per phase, and follows Class \"A\" Insulation standards. The stabilizer ensures No Load Losses <0.5%, Full Load Losses <2.5%, and an efficiency of >95% with a continuous 24x7 duty cycle. Designed for 3-phase, unbalanced loads, it includes a Digital Voltmeter/Ammeter for monitoring. Essential protections include Overload/Short Circuit Protection, High/Low Voltage Cut-off, Bypass Arrangement for Emergencies, and Single Phase Sequence Change Protection, ensuring reliable and uninterrupted operation complete in and including providing of suitable size plateform for mounting stabilizer as per site requirement complete all as specifed and directedNote : 1. Stabilizer shall be provided with first fill of transformer oiland cost of the same is deemed to be included in unit quoted rates.2.Plateform for mounting of stabilizer of suitable size shall be provided by the contractor as per manufacturers advise and the cost of the same is deemed to be included in unit quoted rates.MakeVolina, ITE Gurgaon, Vinteck |
| 17 | Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Copper bus bar for distribution system and type tested at CPRI, complete with bus bars and control wiring complete including dismantling of old LT panel and including the following, LT panel 2INCOMING :(a)MCCB 200 Amps, 4 pole , Thermal magneticrelease, 16 KAadjustable 70 to 100%, 415 Volts, 50 Hz-01 NosOUTGOINGS : (a)MCCB 100 Amps, 4 pole , Thermal magneticrelease, 16 KAadjustable 70 to 100%, 415 Volts, 50 Hz-03 Nos (1 nos for equipment load ,1 nos for building load,1 nos harmonic filter) |
| 18 | Supply, Installation, Commessioning and Testingof 25 Amp 3 phase 4 wire, 415V, 50Hz, IGBT Fired modular type Active Power with touch screen HMI unit with 25 Amp incomer MCCB, microprocessor release, 25 KA, the harmonic filter enclosure shall be made out of 2mm thick CRCA sheet duly powder coatedSiemens Gray 7032 color coated enclosure IP-20 Protection with future provisios. Note:-(i) Modular IGBT based Active Power Filter Units with embedded cooling fans should be used in separate non-compartmentalized compartments in APF with proper ventilation to reach the target rating of total Active Harmonic Filtration. Temperature sensors shall be provided to monitor APF module’s internal temperature, and cooling fans’ rotating speed shall be adjusted according to the detected internal temperature. Each filter module is working independently even if one module got faulty rest system will work independently.(ii) Modular APF Unit / Units shall have basic function of harmonic current elimination to reduce THD-I and load imbalance correction. (iii) The APF system shall be modular as described above with each APF module shall be capable to mitigate harmonic, Power factor correction (Lead and Lag) and unbalancing. It should work normally even when anyone of the module gets failure in case of multiple modules. The APF system should be able to eliminate harmonic current of 2nd to 50th order (selectable) and correct load imbalance (compensate Negative and Zero sequence). Its operational Voltage Range should be AC 415V +15%, -20%, L-L. Frequency Range: 50/60Hz ±5Hz. It should have Power Scalability. One HMI display module should be able to display running data and set parameters for multiple APF modules in Hybrid System. (iv) APF shall have Inrush Current ≤120% of its rated current. Instant Response Time: ≤ 100us. Full Response Time: ≤ 20ms. Operating Ambient Temperature: -10 to 50 without derating. Programmable Current Transformer Ratio. It shall have built in protection against surges, sags, over voltage and voltage surges from AC source, and load switching and circuit breaker operation in the distribution system. The APF shall be CE marked in accordance with EEC directives 73/23 “low voltage” and 93/68 “electromagnetic compatibility.Make: - Universal Switch Gear Control / Tricolite / Siemens / ABB |
| 19 | M& L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth plate 32 X 6 mm by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 50 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 20 | M&L for chemical earthing with Copper earth plate of size 900 x 600x5mm buried diagonally directly in ground, Earth pit shall be not less 5100mm depth from GL level, 1800mm length and 1600mm widthwith top edge of the plate shall be not less than 3400mm below ground level connected to and including providing with copper strip of size 32 x 6mm, 07.50 mtr length and fixed by means ofnuts, bolts, check nuts and washers of suitbale metal and providing of common salt, charcoal dust and chemical MgSo4 with alternate layer from bottom of the excavated pit upto 1700mm high, The copper plate shall be packed minimum 300mm all around the copper plate in alternate layer of100mm thick (Layer shall be of charcoal dust - 100mm, common salt - 100mm, MgSo4 - 100mm maintain earth resistance less then 1 ohmand the same shall be repeated upto 1700mm height) in and including necessary excavation, returing filling in any type of soil and testing complete all as specified and directedin and including the following:-(a) Excavation and earth work for making hole for electrode in any type of soil(b) PCC earth Pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 400mm thick in PCC 1:2:4 type B-1, reinformed with welded steel wire fabric weighing not less than 01.87Kg/Sqm, PCC earth pit shall be constructed as per plate Number 5of MES SSR Part -1 (1991)(c ) Funnel with watering pipe of GI 20mm nominal bore light grade and lugs etc complete all as specified and directed(d) 50mm bore GI light grade pipe with all fittings for protection of copper strip upto 5 meter length(e) Adequate quantity of Common salt, charcoal dust and MgSo4 chemical as required(f) Testing after completion of work, if testing result is not satisfactory, earthing will be redone by the contractor at his own expense |
| 21 | Supply and fixing in replacement GI powder coated perforated type cable tray14 SWG, (2mm thick) of width 150mm and height 50mm with necessary coupler plate and cable tray cover where required with PVC tie for fixing of cable compete all as specified and directed. |
| 22 | Supply and fixing in replacement GI powder coated perforated type cable tray14 SWG, (2mm thick) of width 300mm and height 50mm with necessary coupler plate and cable tray cover where required with PVC tie for fixing of cable compete all as specified and directed. |
| 23 | Supply & fixing MS Cross arms , bracing,supports, clamps and back plates fabricated from structuralsteel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only. |
| 24 | Supply, fixing and connectingconventional optical smokeDetectors Complying with and type certifiedcomplete with standard base for conventional detector complete all as specified and directed |
| 25 | Supply, installation, commisioning and testing 02 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed. |
| 26 | Supply, fixing and connecting conventional type manual call point resettable complete all as specified and directed |
| 27 | Supply, fixing, connecting and testing conventional wall sounder complete all as specified and directed |
| 28 | Supply and fix Remote response indicators complete all as specified and directed |
| 29 | S&F2x1.5 sq. mm +1x1.0 sq. mm earth wirefor circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core in and including rigid, non metallic PVC conduit of suitable sizeon surface complete as per site requirement and as directed by Engr-in-charge |
| 30 | S&F2x2.5 sq. mm +1x1.5 sq. mm earth wirefor circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through rigid, non metallic PVC conduit of any type or sizeon surface as per site requirement and as directed by Engr-in-charge |
| 31 | Supply, installation, testing and commissioning of Inverter Technology,Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap 1.5 TR, fitted with rotary compressor, Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) , clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipesand making good the disturbed surfaces of wall with cement mortar, white cement and painting works to match the existing surfaces of walls complete all as specified and directed.Make-Latest Model of LG/Blue Star/Hitachi/Voltas/lyod |
| 32 | Supply & fixing heavy duty copper pipe 12mm (1/2\") dia/ bore thickness not less then 0.70 mm complete including brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. |
| 33 | Supply & fixing heavy duty copper pipe 6mm (1/4\") dia/ bore thickness not less then 0.70 mm complete including brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. |
| 34 | supply and fixing new nityrile rubberinsulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR complete all as directed by engg-in-charge |
| 35 | Supply & fixing in replacement wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed.Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS. |
| 36 | S&F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacitycomplete all as specified and directed by Engr in charge. |
| 37 | S7Ffor wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS four core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity complete all as specified and directed. |
| 38 | M & L for surface Sub main wiringwith tworunsof 4 sqmm single core PVC insulated unsheathed multistrandedwith copperconductorcable , 1100Volts FRLS-Hgrade ISImarkeddrawnthrough in and including stove enamelled steel conduit& including onerunof 4 sqmmPVCinsulatedunsheathed strandedcopper conductor cablegreenin colour forearthcontinuityconductor and making good the distrubed surfaces after completing the work and clearing the site complete all as specified and directed.Note :- Two runsof4 sqmm cableandonerun of 4 sqmm earthwire and steel conduit pipe shallbemeasuredasonelength. |
| 39 | Supply & fixing new PVC drain pipe 15 mm dia with coupler Joint for Split/window AC complete all as specified & as directed. |
| 40 | Supply & fixing in replacement Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed. |
| 41 | Taking down door frames with chowkhat exc 1.5 sqm and n. exc.4.00 sqm each with shutters (without taking off shutters from the frame). |
| 42 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame/shutter work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including roller for, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 43 | S&F aluminum anodized handle cast type 150mm size |
| 44 | S&F 300MM Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) & fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 45 | S&F 200 mm sizealuminium anodised barrel tower boltof extruded section . |
| 46 | S & F 4.8 mm thick ACP sheet, selected quality (Tinted) and fixed to aluminium door/window in square exc 0.5 sqm in each pane complete all as specified and as directed. |
| 47 | M&L for precast cement concrete solid blocks ( 1:3:6 ) type C-I (using 20mm graded stone aggregate) exc 10cm in width as in block masonry built in CM 1:4 etc complete all as specified. |
| 48 | M & L 15 mm thick rendering (INTERNAL) in cement mortar 1:6 on stone masonry surfaces of fair faces of brick or concrete surfaces, finished even and fair complete. |
| 49 | M & L 15 mm thick rendering (external) in cement mortar 1:4 on stone masonry surfaces or other than of fair faces of brick or concrete surfaces, finished even and fair complete. |
| 50 | M & L for prepariation of newly plastered surfaces and applying two coats of distemper oil emulsion (White or tinted) over a coat of chalk whiting on surfaces of wallscomplete all as specified and directed. |
| 51 | M & L for prepariation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resitant primer on surfaces of walls any colour as approved by GE. |
| 52 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as directed. |
| 53 | M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as directed. |
| 54 | Formwork to sides of concrete foundations, Beam, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work, flat andrough finished surfaces of concrete; vertical or to batter. |
| 55 | M&L for reinforced cement concrete (Nominal design mix) 1:11/2:3 (20mm graded aggregates) in slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the likeas directed. |
| 56 | M&L for surface point wiring controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the distrubed surfaces in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLS copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly complete all as specified and directed. One light point controlled by one, one way switch |
| 57 | -Ditto- as per Ser No 56.00 above but One Fan point controlled by one, one way switch |
| 58 | -Ditto- as per Ser No 56.00 above but One socket outlet 3 Pin, 6 Amp on independent board |
| 59 | -Ditto- as per Ser No 56.00 above butOne socket outlet 3 Pin, 6 Amp on same board. |
| 60 | M&L for surface point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC cassing capping on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceilingincluding one run of PVC insulated FRLS copper conductor cable of 2.5 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 61 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 62 | S&Fswitch piano flush type single pole one way 5 Amp (ISI Marked) |
| 63 | S&F switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 64 | S&F socket out let 2 in 1, 3 pin 5 Ampflush type (ISI Marked) |
| 65 | S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 66 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd. |
| 67 | Supply and fixing Surface and wall mounted LED tube light fittings of cap 20W , four feet Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and two Nos of square type PVC Box for mounting of LED fittings complete all as specified and directed. |
| 68 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) |
| 69 | Supply & fixPrewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutralcomplete all as directed by Engineer-in-Charge. |
| 70 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) ofof rating SP 5 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed |
| 71 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) ofof rating SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed |
| 72 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of TPN/FP 40 to 100 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed |
| 73 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 74 | Supply and fixing in repair GI Pipe light grade, 40mm dia , galvanized, with all fittings complete all as specified and directed |
| 75 | M&Lfor copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground |
| 76 | M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw and protected with 3mm thick enclosure completed closed for test point with 4 nosof screws with wall complete all as specfied and directed. |
| 77 | M&L for porceiline insulator suitable for fixing earthing strip to the wall / floor etc complete with necessary nuts, bolts and fixing material complete all as specified and as directed |
| 78 | M&L for earthing complete with CPRI tested 50mm dia, pure copper earth electrode pipe of length 3000mm, pipe in copper strip Technology with NABL tested, RoHS compliant earth enhancement compound 50 Kg in each bore hole in tripod configuration (three numbers of 50mm dia pure copper electrode pipe) interconnectedwith copper strip of size 20x3.15 mm and connected by means of exothermic brazing & porected by GI pipe light grade 32mm bore andpolycarbonate/ PVC earthing pit cover connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed.Note (i) Cost of copper strip 20x3.15 mm and 32mm dia GI pipe light grade required for interconnection of three numbers of pure copper 50mm dia earth electrode is deemed to be included in unit quoted rates.Copper strip of suitable size from earth pit to test point/equipment shall be measured and paid seperately(ii) Cost of earth work, boring, polycarbonate/ PVC earthing cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates.(iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted ratesiv) The boring will take place for 3 meter depth & 350mm dia for three numbers of pure copper earth electrode pipe to form tripod configuration.Earth enhance compound to be filled around the earth electrode in 100mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork.The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each.The PVC pipe to be removed sinultaneously.The cost of all this is deemed to be included in the quoted rate.(v) Minimum distance between each earthing is not less than 3 running meter(vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms |
| 79 | Antistatic Flooring 3mm thick vinyl for electrostatic discharge as per manufacturersspecifications complete including scraping down the existing surface to finished level appropriate for laying of the ESD surface all as specified and directed by Eng In Charge. |
| 80 | Supply, installation, testing and commissioning of Inverter Technology,Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap 1.5 TR, fitted with rotary compressor, Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) , clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipesand making good the disturbed surfaces of wall with cement mortar, white cement and painting works to match the existing surfaces of walls complete all as specified and directed. Make-Latest Model of LG/Blue Star/Hitachi/Voltas/lyod Note:-(i) All above rates shall be included, 3 Mtrs of Copper Pipes and 3 Mtrs of3 Core, 2.5 Sqmm Cable are provide by OEM.(ii) Labour/Transportation charges for site are deemed to be included in the above quoted rate. |
| 81 | Supply & fixing heavy duty copper pipe 12mm (1/2\") dia/ bore thickness not less then 0.70 mm complete including brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. |
| 82 | Supply & fixing heavy duty copper pipe 6mm (1/4\") dia/ bore thickness not less then 0.70 mm complete including brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. |
| 83 | supply and fixing new nityrile rubberinsulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR complete all as directed by engg-in-charge |
| 84 | Supply & fixing in wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed.Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS. |
| 85 | S&F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacitycomplete all as specified and directed by Engr in charge. |
| 86 | S&Ffor wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS four core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity complete all as specified and directed. |
| 87 | M&L for submain wiringwith 2 single corePVC insulated unsheathed multi stranded copper conductor FRLS wire 6.00 Sq mm 1100 volts grade including and 6.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in conduit Note : Two run of 6.0 Sqmm cable andone run of 6.0 Sqmm cable as earth continuity conductor shall be measured & paid as one unit. |
| 88 | Supply & fixing new PVC drain pipe 15 mm dia with coupler Joint for Split/window AC complete all as specified & as directed. |
| 89 | Providing and making one number hole of upto 20” (Twenty Inches) length and 2” (Two Inches) diameter in existing wall/slab (RCC/brick/stone) by means of core cutting machine, including proper fixing of machine, T&P, labour, scaffolding as required, ensuring neat and clean finish without damage to adjoining surface, and after completion of work, properly filling the annular gap around the pipe/opening with cement mortar (1:2) or white cement as required, finishing the surface flush with adjacent area, cleaning the site of all debris and making good the surface, all complete as per specification and as directed by Engineer-in-Charge. |
| 90 | Supply & fixing weather protection cover for outdoor AC unit of heavy gauge Minmum 1.0 mm G.I. sheet with anti-rust coating, sloping/triangular top, front & both sides covered, supported on M.S. pipes . fixing cleats, securely anchored with bolts/nuts/washers, painted with red oxide primer & 2 coats synthetic enamel Paint,all complete as per specification and as directed by Engineer-in-Charge. |
| 91 | Supply & fixingOutdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed. |
| 92 | Supply, laying & testing cable XLPE insulated , screened , PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, of size 25 Sqmm 4 Core. |
| 93 | Supply, installation, commissioning and testing of non clog self priming pumpsetmounted on common base plate foundation having discharge 35 LPS , 15 mtr head ,1440 RPM & Suction and delivery 100 mm x 100 mmCI Casing,CI impeller,CS Shaft,gland packing directly coupled with and including electric motor minimum capacity of 9.3KW/12.5 HP, 3 phase, 415 volts, 50 Hz, 1440 RPM TEFC complete including PCCfoundation, copper conductor cable of suitable size including protection flexible pipe for cable from starter to motor terminal, Suction line pipe GI & fitting flanged, Foot Valve, Pressure Guage and Air Vent pipe, Fitting Accessories required complete all as per manufacturer\"s recommendation/Design. Complete all as directed with all accessories and comprising of the following:-(a) 06 runs of Single core cable PVC insulated copper conductor, multistranded, 1100 volts grade of suitable size drawn through and including PVC flexible pipe from motor to starter panel for each pump set complete connection with copper lugs, cable glands etc.(b) PCC foundation in CM 1:2:4 type B-2 using 40 mm graded aggregate 20 cm above GL and 30 cm below GL including grouting of eye bolts nuts etc for pump set/motor of adequate size as per manufactureres reccommendations.(c) Common base frame suitable for above pump set as per manufacturers recommendation.Note :- (i) Cost of alignment with dial guage and making necessary adjustments including shim packing etcwith each pump including jointing material shall deemed included in unit rate quoted by contractor.(ii) Foot Valve of suitable size shall be measured and paid seperately under respective item of Sch. |
| 94 | S&F Fully automatic star delta starter for centrifugal pumpset pump, in sheet steel enclosure, suitable for following capacity, 3 Phase, 50 Hz, 415 Volt, AC supply suitable for following capacity pump set compressing of Ammeter, Volt meter, selector switch and indicator lamp, single phase preventer, Auto/Manual Mode, Under current, over current, phase reversal, phase unbalance, locked rotor and ground fault and testing and including dismantling & taking out old unserviceable star delta starter complete all as specified and directed. (a) For 12.5 HP motor.Make : BCH/C&S/Havells/Legrand/L&T. |
| 95 | Supply, laying and jointing GI tubes, medium grade 100mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr-in-Charge. |
| 96 | M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth strip 32x6 mm by means of bolts, nuts check nuts and washers of galvanized iron and steel earth strip protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -3 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion. |
| 97 | M&L for Brass/ Gun metalfoot valve of size 100mm bore (ISI marked & IS 318 LTB2 ) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers complete all as specified & directed. |
| 98 | M& L Pre-cast cement concrete block masonry type C1 (1:3:6) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete |
| 99 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces using cement mortar 1:6 finished even and smooth without using extra cement |
| 100 | M&L for Rendering 10mm thick on other than fair faces of brick work or concrete surfaces using cement mortar 1:4 finished even and smooth without using extra cement |
| 101 | M&L for two coat of cement based Paint over a coat of primer on newly plastered surface including preparation of newly plastered surface |
| 102 | M&L for two coat of Oil Bound distemper over a coat of primer on newly plastered surface including preparation of newly plastered surface |
| 103 | M&L for Cement concrete in foundations, filling and mass concrete Type D2 (1:4:8) using 40 mm graded aggregate |
| 104 | M&L Anodised aluminium frame powder coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, and partition of any type with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 105 | Supply and fixing 100mm long butt hinges mild steel medium weight cold rolled ISI marked. |
| 106 | S&F 250 mm long mild steel sliding bolts, stove enameled black, with bright bolt not less than 12mm dia all as specified |
| 107 | Supply and fixing as Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. |
| 108 | S&F aluminium anodised barrel tower bolt of extruded section 150mm long |
| 109 | Supply and fixing 150mm long extruded aluminum handles fabricated type anodized, ISI marked. |
| 110 | S&F Door closer hydraulically regulated, designation No. 1 universal type, aluminium (extruded section body) suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified. |
| 111 | S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified |
| 112 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 113 | S&F 4.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in squareexc 0.5 sq. m in each pane complete all as specified |
| 114 | Demolition of Concrete in ground floors andpavings exc 15 cm thickness |
| 115 | Cutting out bricks, forming toothing for,and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only |
| 116 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any soft soil |
| 117 | M&L forProviding and laying 60mm thick factory made (Rubber moulded) chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail