Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-01-2026 | Corrigendum No 01 | BOQ | 21-01-2026 |
| Sl. No. | Item Description |
| 1 | M&L for surface dressing n.exc 15 cm deep and getting out in hard/dense soil complete all as specified and directed by the Engg-in-Charge. |
| 2 | M&L for Excavation in trenches n exc. 1.5m in depth for foundation and not exc 10 sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed by the Engg-in-Charge. |
| 3 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation,filling and mass concrete complete all as specified and directed by the Engg-in-Charge. |
| 4 | M&L for precast cement concrete type C1, 1:3:6 using 20mm graded stone aggregates, block masonary with solid blocks, exc 10cm width and setting in cement mortar 1:6 complete all as specified and directed by the Engg-in-Charge. |
| 5 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work in flat rough finished surfaces of concrete complete all as specified and directed by the Engg-in-Charge. |
| 6 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions in flat fair finished surfaces of concrete complete all as specified and directed by the Engg-in-Charge. |
| 7 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc in flat rough finished surfaces of concrete complete all as specified and directed by the Engg-in-Charge. |
| 8 | M&L for TMT bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including for mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by EIC. |
| 9 | M&L for TMT bars Mild steel bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including for mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 10 | M&L forreinforcement cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) in foundation , including rafts, footing, foundation beams, plinth beams, bases for coloums etc complete all as specified and directed by the Engg-in-Charge. |
| 11 | M&L for reinforcement cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed by the Engg-in-Charge. |
| 12 | M&L for reinforcement cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate)as in beams, cantilevers, bressumers, lintel over 1.5m span complete all as specified and directed by the Engg-in-Charge. |
| 13 | Returning filling incl spreading leveling watering and well ramming in layers not exceeding 25 mm in any type of soil complete all as specified and directed by the Engg-in-Charge. |
| 14 | Removing excavated material n.exc. 50 m and deposited were directed at a level n.exc.1.5 m above the starting point complete all as specified and directed by the Engg-in-Charge. |
| 15 | M&L for Earth filling in floors including spreading, levelling and ramming with watering as required in layers n.exc 25cm thick complete all as specified and directed by the Engg-in-Charge. |
| 16 | M&L for Hard core of broken stones or boulders of gauge in exc 63mm deposited spread and levelled in layers n. exc 15cm thick incl watering and rolled to true surface complete all as specified and directed by the Engg-in-Charge. |
| 17 | M&L 75mm thick PCC (1:4:8) type D2 using 40mm graded aggregate as in sub base to floor or similar works complete all as specified and directed by the Engg-in-Charge. |
| 18 | M&L PCC 1:3:6 type B2 ( using 20 mm grade aggregate) 75 mm thick as in plinth protection/paving or similar works complete all as specified and directed by the Engg-in-Charge. |
| 19 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 20 | M&L for rendering 15 mm thick in CM 1:4 on other fair faces of brick work or concrete surfaces in two layers 10mm & 5mm thick with WPC to be used in outer layer of 5mm thick, finishing even and smooth without using extra cement complete all as specified and directed by the Engg-in-Charge. (WPC measured and paid seperately) |
| 21 | Supply only liquid waterproofing compound complete all as specified and directed by the Engg-in-Charge. |
| 22 | M&L for MS Fe-290 (Gde E-165) for roof trussed (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by the Engg-in-Charge. |
| 23 | S&F Rolled mild steel Gde Fe-290 (Gde E-165) as in Plates (plain or chequered) channels,angle sections, square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed by the Engg-in-Charge. |
| 24 | S&F 20mm dia of neck mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, length of bolt exc 30cm long complete all as specified and directed by the Engg-in-Charge. |
| 25 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 26 | S&F for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 27 | M&L PCC type B0 1:2:4 (12.5mm graded aggregate) 25mm thick as in floor finished surfaces fair and even to receive tile complete all as specified and directed by the Engg-in-Charge. |
| 28 | M&L Non skid Ceramic colouredtiles 7 to 8mm thickarea of each tilesexc 0.06 sqm but not exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed bed in CM 1:6 finished even and smooth for receive tiles complete all as specified and directed by the Engg-in-Charge. |
| 29 | M&L for Glazed ceramic coloured tilesin vertical surfaces 350x450x7mm thick etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tile over 10mm thick rendering in cement mortar 1:4 in backing coat of plaster for skrting/dado complete all as specified and directed by the Engg-in-Charge. |
| 30 | M&L for 20mm thick granite (of any type) work table rubbed and polished) in steps, pillars, jambs, window cills, cooking plateform/whash basin plateform etc and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by the Engg-in-Charge. |
| 31 | S&F 2nd class softwood(KAIL) as inPlain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by the Engg-in-Charge. |
| 32 | S&F 35mm thick2nd class soft wood (KAIL) plain framed panelled shutters (any No of pannels) with panels of timber flat on both sides (Feather edgeed), or of veneered particle board medium density, wood particle board withcommercial face veneers, supplied and fitted to chowkats complete all as specified and directed by the Engg-in-Charge. |
| 33 | S&F 30 mm thick 2nd class soft wood (KAIL) glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc dividedinto squares with plain chamfered or rounded, mitred and rebated sash bars any numbers complete all as specified and directed by the Engg-in-Charge. |
| 34 | S&F 100 mm butt hinges medim weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by the Engg-in-Charge. |
| 35 | S&Fbutt hinges medium weight cold rolled mild steel of 75 mm long fixed with screws or welded complete all as specified and directed by the Engg-in-Charge. |
| 36 | S&F anodised aluminium barrel tower bolt extruded sections 200 mm size complete all as specified and directed by the Engg-in-Charge. |
| 37 | S&F anodised aluminium barrel tower bolt extruded sections 150 mm size complete all as specified and directed by the Engg-in-Charge. |
| 38 | S&F 125mm extruded aluminium alloy handles febricated type anodised complete all as specified and directed by the Engg-in-Charge. |
| 39 | S&F 100mm extruded aluminium alloy handles febricated type anodised complete all as specified and directed by the Engg-in-Charge. |
| 40 | S&F 250mm Aluminium alloy, anodised,sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by the Engg-in-Charge. |
| 41 | S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beading in square n exc 0.5 sqm complete all as specified and directed by the Engg-in-Charge. |
| 42 | M&L preparation of new plastered surfces of walls and applying three coat white wash complete all as specified and directed by the Engg-in-Charge. |
| 43 | M&L for preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by the Engg-in-Charge. |
| 44 | M&L for preparation of wood and wood based material surface of any description description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by the Engg-in-Charge. |
| 45 | M&L prepation of new or previously untreated surfaces on steel of any description, over 10cm in width or girth, not otherwise described andapplying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by the Engg-in-Charge. |
| 46 | S&F High grade stainless steel toilet pan of size 58.5x48.2x30.0 cm (excludiig flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F PVC flushing cistern valveless syphonic action type flushing cistern low level 10 Ltrs white with inlet ball valve float and handle incl bracket complete all as specified and directed by the Engg-in-Charge. |
| 48 | S&F Vitreous china urinal bowl type complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinals to plug with and incl 60cm long brass screw pointing around urinal back in cement complete all as specified and directed by the Engg-in-Charge. |
| 49 | S&F 32mm CP waste coupling with waste pipe suitable for urinals complete all as specified and directed by the Engg-in-Charge. |
| 50 | S&F CP urinal spreader complete all as specified and directed by the Engg-in-Charge. |
| 51 | S&FWHB counter sunk type ovel under/over counter shape in fixed & on stone slab incl necessary cutting etc complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F pillar tap 15 mm bore fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed and fly screwed for iron pipe complete all as specified and directed by the Engg-in-Charge. |
| 53 | S&F 15mm dia chromium plated fancy type Bib tap with round handle screwed down screwed for iron pipe or brass ferrule complete all as specified and directed by the Engg-in-Charge. |
| 54 | S&F 15mm dia chromium plated fancy type stop valves/angle cock screwed down high pressure, screwed for iron pipe complete all as specified and directed by the Engg-in-Charge. |
| 55 | S&F PVC connection 15mm size, with PTMT nuts of length 600mmcomplete all as specified and directed by the Engg-in-Charge. |
| 56 | S&F 32mm CP waste coupling with waste pipe for WHB complete all as specified and directed by the Engg-in-Charge. |
| 57 | S&F, 600mm x 450mm beveled edge mirror of selected quality, thickness of glass 5mm, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engg-in-Charge. |
| 58 | S&F Towel rail 600 mm long PTMT fixed with and incl chromium plated brass screws and wooden/ plastic cleats (Min Wt 170 gms) complete all as specified and directed by the Engg-in-Charge. |
| 59 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement diameter of outlet 75mm complete all as specified and directed by the Engg-in-Charge. |
| 60 | S&F 75mm bore PVC (SWR) bends any radius with access door complete all as specified and directed by the Engg-in-Charge. |
| 61 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed by the Engg-in-Charge. |
| 62 | S&F 110mm PVC (SWR) \"P\" trap complete all as specified and directed by the Engg-in-Charge. |
| 63 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed by the Engg-in-Charge. |
| 64 | S&F110mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed |
| 65 | S&F75mm bore PVC (SWR) vent cowl complete all as specified and as directed |
| 66 | S&F PVC (SWR) pipes110mm dia single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 67 | S&F PVC (SWR) pipes75mm dia single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 68 | S&F for 25 mm outer dia 3-layer PPR polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stablized and antimivrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors complete all as specified and directed by the Engg-in-Charge. |
| 69 | S&F for 20mm outer dia 3-layer PPR polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stablized and antimivrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors complete all as specified and directed by the Engg-in-Charge. |
| 70 | S&F rotational moulded polytheline water storage tank 1000 Ltrs capacity (cylinercial/vertical with closed top) hoisted and fixed in position complete all as specified and directed by the Engg-in-Charge. |
| 71 | S&F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed of 20mm bore dia complete all as specified and directed by the Engg-in-Charge. |
| 72 | S&F Vitreous China wash down water closet pan including P or S trap of bore 125/110 mm (pedestal pattern), white or in matching colour of tiles(excludingflushing cistern and flush pipe) including plastic water closet seat, white or in matching colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and wash down water closet complete all as specified and as directed. |
| 73 | S&F Viterous China squatting pan `Orrisa\" pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified and as directed. |
| 74 | S&F for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm longfixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 75 | S&F for Brass CP shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed. |
| 76 | S&F CP soap tray fixed to walls with rubber plugs or screws complete all as specified and directed. |
| 77 | S&F forTubular towel rail, ISI marked 60cm long between flanges, 20mm dia \"D\" type Brass Chromium plated inclbrackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 78 | S&F forBall valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe complete all as specified and directed by the Engg-in-Charge. (min.weight 20mm-210 gms) |
| 79 | M&L for providing PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, benching etc. complete all as specified and directed by Engr-in-charge. |
| 80 | M&L for precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge. |
| 81 | Removing excavated material (soil) exc. 500 m but n.exc. 1.5km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 82 | M&L for HDPE DWC pipe 200mm internal dia and external dia 230mm SN-04 confirming to SN-4 fixed with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc single Y junction laid in tranches and jointed with cement solvent including testing complete all as specified and directed by Engineer-in-Charge. |
| 83 | M&L for concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 200 mm bore pipe, complete all as specified and directed by Engr-in-Charge. |
| 84 | M&L for Provn of Sockage well of 3.00 dia and 3.00m deep incl excavation in hard dense soil, foundation in PCC 1:3:6, Well of honey combed and each solid in M-25 Concrete, incl, intercepting chamber, screen chamber stone work in CM 1:4 RCC cover slab in M-25 filling with stone boulder complete all as specified and directed by Engr-in-Charge. (As per TD Drg No. CESZ/TD/1078/2011, Sheet 1/1) |
| 85 | S&F PP-R Gate valve (brass insert) of size 25 mm as per site requiremnet complete all as specified and directed by Engr-in-Charge. |
| 86 | Dismantiling of plain corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed by Engr-in-Charge. |
| 87 | Demoliton of stone/ boulder masonry, precast concrete articles and precast concrete block walling including all quoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified and directed by Engr-in-Charge. |
| 88 | M&L for cement concrete type C-1 (1:3:6) use 20mm graded agg 50 mm thick as in copings slightly rounded or chamfered angles and throating, complete all as specified & directed. |
| 89 | Demolition of Cement Concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and as directed |
| 90 | M&L for 25mm thick cement concrete type C-2 1:3:6 (20 mm graded aggregate) as in sub base of floors complete all as specified and directed by Engr-in-Charge. |
| 91 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by Engr-in-Charge. |
| 92 | M&L for machine cut Kota stone slab flooring 20-25mm thick, over cement screed bed or bedding layer of cement mortar 20 mm thick in CM for laying floor finishes base laid and jointed with grey cement slurry mixed pigment to match the shade of the slab including rubbing and mirror polishingpreparation complete all as specified and as directed by Engr in charge. |
| 93 | Dismantiling of floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge. |
| 94 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge. |
| 95 | S&F in repairs 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails on wall to timber frame work complete complete all as specified and directed by Engr-in-Charge. |
| 96 | S&F in repairs 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails on ceiling to timber frame work complete all as specified and directed by Engr-in-Charge. |
| 97 | Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in framed work, in any position complete complete all as specified and directed by Engr-in-Charge. |
| 98 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 99 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed by Engr-in-Charge. |
| 100 | Taking down chowkats or frames not exc 1.5 Sqm with shutters (without taking off shutters from the frames) each complete all as specified and directed by Engr-in-Charge. |
| 101 | Taking down chowkats or frames exc 1.5 Sqm but n.exc 4.0 Sqm with shutters (without taking off shutters from the frames) each complete all as specified and directed by Engr-in-Charge. |
| 102 | S&F 30 mm thick 2nd class soft wood (KAIL) plain framed panelled shutter (any number of panels)with panels of timber flat on both sides (Feather edge) or of veneered particle board medium density wood particle board with commercial face veneers and fitted to chowkhat complete all as specified and directed by Engr-in-Charge. |
| 103 | S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified and directed by Engr-in-Charge. |
| 104 | S&F 100mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed by Engr-in-Charge. |
| 105 | S&F 300mm Aluminium alloy, anodised,sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engr-in-Charge. |
| 106 | S&F in repairs mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engr-in-Charge. |
| 107 | M&L for preparation of old surface of wood and wood based material surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 108 | Dismantling of PVC drain pipes of any size or any dia and any position/ description, including disposal or removing to storecomplete all as specified and directed by Engr-in-Charge. |
| 109 | Taking up or down 20 mm dia steel tubing/PPR connections, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge. |
| 110 | Taking up or down 25 mm dia steel tubing/PPR connections, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge. |
| 111 | S&F in repair 20 mm dia chromium plated fancy type Bip tap with round handle screwed down for iron pipe or brass ferrule complete all as specified and directed by Engr-in-Charge. |
| 112 | S&F in repair kitchen sink with drainage board made outof 1mm thick stainless steel with plugs, washers and wastes, including bedding in cement mortar to dwarfwall or including fixing cantilever bracket and connecting union to pipe over all size 915 mm X 460 mm & bowl size 410 mm X 330 mm X 160 mm including sink coupling and waste pipe complete all as specified and directed by Engr-in-Charge. |
| 113 | Dismantling PVC water tanks of capacity exc 500 ltr but n exc 1000 ltr and removing to store complete all as specified and directed by Engr-in-Charge. |
| 114 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge. |
| 115 | M&L rendering 15mm thick cement plaster in cement mortar (1:4) finished even & fair withoutusing extra cement on brick/concrete surfaces complete all as specified and directed by Engr-in-Charge. |
| 116 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. |
| 117 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing capingwith all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cablefor earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer pointcontrolled by one switch. |
| 118 | All as per Srl item No. 78.00 here in before but usingcable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 119 | All as per Srl item No. 78.00 here in before but usingcable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 120 | S&F Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by Engr-in-Charge. |
| 121 | S&FSwitch socket combination 2 in 1, and 3 and 2 pin, 5 Ampsflush type complete all as specified and directed by Engr-in-Charge. |
| 122 | S&F Switch socket combination 2 in 1,5 and 15 Ampsflush type complete all as specified and directed by Engr-in-Charge. |
| 123 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 124 | S&F LED lights fitting, surface mounting general purpose ultra slim economical LED batten of 1x 18W/20W,lumen out put 100lm/wattt, CCT:6500K/3000K , PF>0.9, in extruded PC housing and round/square shaped diffuser including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 125 | S&F LED light fitting 1x9W/ 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 126 | M&L of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed by Engr-in-Charge. |
| 127 | S&F Sheet metal enclosure for DB\"s Double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by Engr-in-Charge. |
| 128 | S&F 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 32 Amp in the MCB DB complete with connection testing complete all as specified and directed by Engr-in-Charge. |
| 129 | S&F 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed. |
| 130 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300mm complete all as specified and directed by Engr-in-Charge. |
| 131 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6.0mmthick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion.Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate,(ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 132 | S&Fin replacement 1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified. |
| 133 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants,sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 134 | S&F in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required Complete all as specified and directed. |
| 135 | S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing complete all as specified and directed by Engr-in-Charge. |
| 136 | S&F in replacement of LED Flood light fitting70 watt5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified and directed by Engr-in-Charge. |
| 137 | Supply and fixing in replacement exhaust fan, steel body, AC single phase, 230 V of size 380 mm sweep with blades and frame and louvers complete with cutting of suitable size of hole on wall with all connected accessories and making surface good after fixing complete all as specified and directed. |
| 138 | S&Fin replacement1100 volts grade heavy duty 16 Sqmm 2 core flat cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 139 | Note : Deduction for amount of Rs. 26120.60 as listed in Schedule \"A\" Part-II (Schedule of Credit) shall be made while awarding of contract. |