| 1 | Complete removal of all existing roof treatment from RCC roof including old hussion felt & preparation of surface with wire brush and cleaning with water complete and M&L for water proofing treatement on non approachable/on accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer/aurhorized applicator of the manufacturer complete all as specified and directed:-(a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab.(b) 15mm thick cement plaster fair finished using cement mortar(1:4) with WPC on roof slab.(c) Applying oil based bitumen primer @0.30 ltr/Sqm on plastered surface.(d) Applying modified APP polymeric membrane 3mm thick and minium weight 3.00 Kg/Sqm for water profing roof , sealing as directed at site with 100mm over laps as per manufacture\"s instruction.Note \" Supply only WPC shall be measured and paid separetly under relevant item.(e) Applying two coats of Aluminium paint over bituminous surface of membrance |
| 2 | Supply only liquid water proofing compound ISI marked |
| 3 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each. Complete all as directed. |
| 4 | S&F Powder coated aluminium windowand ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as 5.5 mm thick glass of approved make, peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 Nos.) suitable handle (1 Nos.) complete all as specified and directed. |
| 5 | Taking down cement plaster on brick or concrete or stone walls etc including racking out joints hacking for key scrubbing down with water any description.complete all as directed. |
| 6 | Material & labour for 10mm thick rendering in CM 1:6 on fair fair faces of brick wall orconcrete surfaces finished even and fair complete all as specified & directed |
| 7 | Material & labour for 15mm thick rendering in CM 1:4 on fair fair faces of brick wall orconcrete surfaces finished even and fair complete all as specified & directed |
| 8 | Material & labour for 5mm thick rendering in CM 1:3 on ceiling or concrete surfaces finished even and fair complete all as specified |
| 9 | M&L forrepair and rendering 10mm thickin CM 1 :3on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete includingcleaning of viisible reinforcementandtreating with cement slurry also necessary repair to cracked concreteif any with cement concrete1:2:4 Type B-0 using 12.5mm gradedstone aggregateincluding necessary scafolding work for double/single storey bldgs complete all as specified & directed . |
| 10 | Material and labour for preparation of OLD plastered surfaces of ceiling and applying one coats of white wash complete all as specified & directed. |
| 11 | Material and labour for preparation of NEW plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 12 | Materials & labour for prepration of NEW plastered surface and finishing the surfaces of wallwith wall care putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 13 | Materials & labour for prepration of OLD plastered surface and finishing the surfaces of wallwith wall care putty and applyingtwo coat of Oil Bound distemper of, any colour, complete all as specified & directed. |
| 14 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.complete all as specified & directed |
| 15 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces.complete all as specified & directed |
| 16 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed |
| 17 | M &L for Vetrified Ceramic tiles 8-10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 18 | M&L for Non - Skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 15mm thick cement screed bed or bedding layerin CM 1:4 .complete all as specified and directed. |
| 19 | M&L for Machine cut kota stone slab flooring 20-25mm thick over incl 18-20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. complete all as specified and directed. |
| 20 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and incl15mm thick plaster in CM 1:4 complete all as specified and directed. |
| 21 | Demolition of cement concrete in ground floors and paving exc 15cm thickness(below or above ground level) all as directed. |
| 22 | M&L for Cement concrete 1:5:10 type E-2 (using 40 mm graded stone aggregate as in filling around shunken areas complete all as specified and directed. |
| 23 | M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate with WPC as in sunken portion and making adequate slope toward spout pipe complete all as specified and as directed. NOTE: - Water Proofing Compound shall be measured and paid separately |
| 24 | M&L for rendering 15 mm thick on concrete orbrick surface in CM (1:3) mixed with WPC as per manufacturer instructions and finishes surfaces even and smooth with out using extra cement.Note - WPC will be measured and paid separtely |
| 25 | M&L for applying two coats evenly a tack coat of hot air blown bitumen of grade 85/25 @ 1.50 Kg per sqm per coat (one coat overplaster and one coat on polythene film) including cleaning of surface over polythene film complete all as specified and as directed |
| 26 | M&L for polythene film black 200 micron thick laid in floor, vertical surface etc complete all as specified and directed. |
| 27 | Taking down eaves gutters and rain water pipes (any ize or patterns)including all heads,shoes,bends,swan-necks etc. |
| 28 | S&F PVC(SWR) floor trap 75mm dia plain with grating incl jointing with solvent cement. |
| 29 | S&F PVC(SWR) multi floor trap/nahani trap 75mm dia plain with grating incl jointing with solvent cement. |
| 30 | S&F PVC(SWR)pipe 110 mm dia grade \"B\" single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp. |
| 31 | M&L PVC (SWR) bend of radius 110mm dia, grade \"B\" |
| 32 | M&L PVC(SWR) Tee of radius 110mm dia, grade \"B\" |
| 33 | M&L PVC (SWR) vent cowl 110mm dia, grade \"B\" |
| 34 | M&L PVC(SWR) pipes 75mm dia, grade \"B single socketed, in any length with rubber ring joints,laid in trenches or fixed to wall with and including stack and clamp. |
| 35 | M&L PVC (SWR) bend of radius 75mm dia grade \"B\" |
| 36 | M&L PVC (SWR) Tee of radius 75mm dia grade \"B\" |
| 37 | M&L PVC (SWR) vent cowl 75mm dia grade \"B\" |
| 38 | Supply, fix 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including taking down old existing GI pipe wherever required and including testing complete all as specified & directed. |
| 39 | Supply, fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including taking down old existing GI pipe wherever required and including testing complete all as specified & directed. |
| 40 | S&F for 110 mm bore PVCfloor traps plain with grating and 300 mm long out let including jointing with cement concrete type B -1 1:2:4 complete all as specified & directed. |
| 41 | Supply & fix in repairvitreous china squatting pan of ‘Orrisa pattern’ size 580x440mm, white with, integral foot rest including replacement of ‘P’ or ‘S’ trap, lime concrete bedding and making good floor complete all as specified and directed. |
| 42 | Supply & fix in repair PVC low level flushing cistern of 9-10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed. |
| 43 | Supply & fix in reapirPVC connections of 600mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed. |
| 44 | Supply & fix in reapir angular valve, 15 mm dia, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed. |
| 45 | Supply & fix in repair bib taps cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed. |
| 46 | S&F in repairvitreous china wash Basin white flat back size 550 x 400mmincluding brackets, cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed |
| 47 | Supply and fixing as in repairs vitreous china urinal , half stall type, whitewith grating and union for discharge pipe (excluding flushing cistern,flush pipe and waste pipe) complete all as specified and directed. |
| 48 | M&L for Non- skid colour ceramic tiles,7 to 8mm thick square/rectangular area of each tile exc 0.11 sqm but n exc 0.18sqmbut in skirting including 10mm thick screed bed in CM(1:4) complete all as specified and as directed by Engr-in-Charge. |
| 49 | M&L for Non Skid ceramic colour ceramic tiles,7 to 8mm thick square/rectangular area of each tile 0.06sqm but not exceeding 0.11sqm ,in floors over and including 15mm thick screed bed in CM(1:6),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacecoloured cement to match the floor complete all as specified and as directed by Engr-in-Charge. |
| 50 | M&L for coloured glazed ceramic colour tiles in vertical surface in Skirting/Dados 350mmx250mmx7mm /450x350x7mm thick over and including 10mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces complete all as specified and as directed by Engr-in-Charge. |
| 51 | S&F in repairs decorative curtain rod made out of 25mm dia (outer dia) MS pipe having wall thickness 0.63mm, PVC coated of any colour and pattern as approved overall dia 28 to 28mm, includiing and including two nos brackets on each ends alongwith globe on each ends for earch window/door fro fixing complete all as specified and directed with fancy design and approved by engineer-in-Charge. |
| 52 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqn each.completed all as directed |
| 53 | S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawingcomplete all as specified and as directed. |
| 54 | Supplied and fixed factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame as per specification & drawing complete all as specified and as directed by Engr-in-Charge. |
| 55 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as directed. |
| 56 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all as directed. |
| 57 | Taking down Old/ Unserviceable MCBDBs SPN/TPN/ Main Switchesby disconnection of electric connection including old unsvMCCBs,MCBs, isolators etc and making good to distrubed surface complete all as directed. |
| 58 | M&L for point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofmodular switch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 59 | All as per Ser item No 58 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 60 | All as per Ser item No 58 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 61 | All as per Ser item No 58 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 62 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 63 | S&F Switch modular singlepole , one way 16 Amps complete all as specified and directed. |
| 64 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 65 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 66 | S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed. |
| 67 | S&F modular Fan step regulator 230 Volts single phase 120 watt, 2 modulecomplete all as specified and directed. |
| 68 | M&L for submain wiring complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 69 | Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. |
| 70 | Supply and fix MCCBDB VTPN 4 way with metal door suitable forProvision ofincommer and out going MCCBs/MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 71 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed. |
| 72 | S&F in replacement ofMCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 73 | S&F in replacement of MCB DP 40Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles. |
| 74 | S&F in replacement ofisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 75 | S&F in replacement of LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed at site. |
| 76 | S&F exhaust fan steel body AC single phase, 230Volts of size 300 mm sweepcomplete with louver shutter and including makingof hole suitablesizefan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. |
| 77 | S & F Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 78 | M &L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge.ii) The earthing resultnot more than 2 Ohms or disered earth resistance value.iii) Meggerrequired for testingwill bebe provided at site by the contractor.iv) Contractor shall submit earth resistance testing report before submission of bill. |
| 79 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |