| Sl. No. | Item Description |
| 1 | POST ANTI-TERMITE TREATMENT |
| 2 | M&L for providing and injecting chemical emulsion for post construction Anti-Termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging, 12mm dia holes with cement mortar 1:2 to match the existing surfacescomplete all as specified and directed. |
| 3 | M&L for providing and injecting chemical emulsion for treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar (1:2) to match the existing floors complete all as specified and directed. |
| 4 | M&L for providing and injecting chemical emulsion for treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 5 | M&L for providing and injecting chemical emulsion for post construction anti - termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 litres per hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed. |
| 6 | GENERAL NOTES FOR ITEM NO 01:-1) Anti-termite treatment work shall be carried out through authorised applicators having valid license from IPCA.2) Anti-termite chemical shall be procured in sealed containers and kept in custody of Engineer-in-Charge. Material would be issued by JE/AGE as per site requirement.3) Quoted rate shall be deemed to be inclusive of the cost of all T&P, protective gear and safety arrangements required for satisfactory execeution of the work. |
| 7 | BRICKWORK & RCC WORK |
| 8 | M&L for Brick Work with Fly-AshBricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6 incl demolition of old brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., and removal of debris outside AF land complete all as specified and directed. |
| 9 | Demolition Cement Concrete (Reinforced) of kitchen slab and similar work (reinforcement cut as required to facilitate demolition) and removing debris, etc. to Outside MOD Land, complete all as specified and directed. NOTE: Old reinforcement shall be measured under Sch of Credit. |
| 10 | -ditto- but for demolition of Cement Concrete (Reinforced) of Roof, Floor (other than Ground Floor) Beam, Staircase, Landings, Chajjas and similar work complete |
| 11 | M&L Reinforced Cement Concrete 1:2:4 type B0 (12.5mm graded stone aggregate) as in Shelves, kitchen slabs, etc incl smooth finishing at Top side without using extra Cement, complete all as specified and directed.(NOTE: MS reinforcement & Formwork shall be measured and paid seperately) |
| 12 | M&L Reinforced Cement Concrete 1:2:4 type B0 (12.5mm graded stone aggregate) as in Chajja, Facia, Sunshade and Similar Items and incl smooth finishing at Top side without using extra Cement, complete all as specified & directed. (NOTE: MS reinforcement & Formwork shall be measured and paid seperately) |
| 13 | M&L for formwork to soffits of suspended slabs such as roof slabs, kitchen slabs, shelves, floor slabs, landings, chajja and similar work; not exceeding 200 mm thick (horizontal or sloping) for rough finished surfaces complete all as specified and directed. |
| 14 | M&L TMT Bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hoping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia or securing with Clips, complete all as specified and directed. |
| 15 | M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Slabs, Manhole Cover Slabs, etc., set in Cement Mortar 1:4, with necessary formwork including dismantling and removal of damaged precast slabs etc complete all as specified & directed.NOTE : Reinforcement will be Measured and Paid separately under relevant Item. Old reinforcement will be measured under Sch of Credit. |
| 16 | WATERPROOFING TREATMENT ON ROOFS |
| 17 | COMMON NOTES FOR ITEM NO 03 & SUB-ITEMS THEREOF:- (1) The work shall be executed only through an authorised applicator of the respective manufacturer, after concluding an MOU/Agreement with the manufacturer for a company-backed guarantee.(2) The MOU/Agreement copy shall be submitted to the Garrison Engineer (GE) by the contractor along with the Performance Security before issue of the Work Order. In case of failure to do so, the contract is liable to be cancelled and the contractor shall be responsible for penalties as stipulated in the tender documents.(3)The contractor shall give a guarantee for 10 years for the effectiveness of the water proofing treatment and submit security depost as specified in particular specifications.(4) The execution procedure, surface preparation, and mix proportions of all materials shall be carried out strictly in accordance with the manufacturer’s latest technical data sheet (TDS) and recommendations.(4) The contractor shall submit complete technical details, product data sheets, and material specifications of all proposed items for prior approval of the GE before commencement of work.(5) The contractor shall procure all materials directly from the respective manufacturers and submit authenticated purchase vouchers/invoices as proof of genuine procurement. All materials shall be from the same manufacturer to ensure compatibility(6) Cost of waterproof coating system, primer, geotextile fabric or HDPE sheet, screed bed, ceramic tiles, and epoxy grout shall be deemed to be included in the quoted rate of the respective item.(7) The quoted rate shall be deemed to include all consumables, T&P, scaffolding, curing arrangements, testing, and safety gear required for the satisfactory completion of the work in all respects. |
| 18 | M&L for dismantling and removal of existing waterproofing treatment of any type and thickness such as bituminous felt, APP membrane, or similar polymeric waterproofing membrane alongwith cement screed bed, any thickness including removal of vegetation, moss, or plants, cleaning the exposed surface, and disposal of all debris outside MOD land, complete all as specified and directed.NOTE:- Demolition of concrete padding over RCC roof, if any below the waterproofing treatment, shall be measured and paid for separately under relevant items. |
| 19 | M&L for uprooting of plants or vegetation growth from wallup to roof level, applying two coats of tartaric acid and repair to broken/chipped off plastered surfaces with cement mortar 1:3 in patches not exc 2.0 sqm and removal of debris outside MOD land and disposed off complete all as specified and directed. |
| 20 | Demolition of plain cement concrete padding over roof of buildings and removal of debris and disposing outside MOD area complete all as specified and as directed. NOTE: For measurement purpose, only thickness of cement concrete portion shall be considered. |
| 21 | M&L for cutting open visible cracks in existing roofs or terraces to a ‘V’ groove, cleaning thoroughly to remove dust, loose particles, and laitance, and filling with approved acrylic / epoxy crack filler paste, complete all as specified and directed by the Engineer-in-Charge.(MAKE: STP, PLASTISEAL / FOSROC, RENDEROC CS / SIKA, SIKADUR-20) |
| 22 | M&L for preparation of old concrete surfaces such as roofs, terraces, and parapets, etc., by picking, wire-brushing, and sweeping clean to remove dust, dirt, laitance, oil, grease, and all loose or de-bonded concrete/screed layers, washing down with clean water to remove foreign matter, and applying one coat of polymer-modified cement slurry consisting of cement mixed with approved polymer (such as SBR or Acrylic Latex) as per manufacturer\"s recommendations, thoroughly brushed over the cleaned and damp surface to form a uniform bonding/waterproofing coat ensuring full coverage at all junctions and corners complete all as specified and directed by Engineer-in-Charge.(Make: STP – SHALSBR LATEX / FOSROC – NITOBOND SBR / SIKA – SIKA LATEX) |
| 23 | M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as padding over roof slab for grade correction, laid over polymer-modified cement slurry, mixed with and including liquid waterproofing compound as per manufacturer’s recommendations, finished even & smooth, laid to proper slope with roof kerbs and rounded or chamfered edges, complete all as specified & directed.Note : Water Proofing compound shall be measured and paid seperately as \"Supply only\". Polymer modified slurry, to be applied before laying of PCC padding shall be measured and paid seperately) |
| 24 | Supply only Liquid Water Proofing Compound, ISI Marked, as approved, complete all as specified and directed. |
| 25 | M&L for cleaning and preparation of freshly laid concrete padding surfaces over roofs, terraces, and parapets, etc. and applying one coat of polymer-modified cement slurry consisting of cement mixed with approved polymer (such as SBR or Acrylic Latex) as per manufacturer\"s recommendations, thoroughly brushed over the cleaned and damp surface to form a uniform bonding/waterproofing coat ensuring full coverage at all junctions and corners, complete all as specified and directed.(Make: STP – SHALISBR LATEX / FOSROC – NITOBOND SBR / SIKA – SIKA LATEX)(NOTE: This item shall be provided only when cement mortar bedding layer is provided over new PCC padding and when PCC padding and cement mortar layer are not laid monolotically) |
| 26 | M&L for applying a 10 mm thick layer of cement mortar (1:3) mixed with SBR Latex as per manufacturer’s recommendations, over old or new PCC padding, to form a smooth and even surface, including rounding/angling at the junctions of roof slab and parapet walls, complete all as specified and directed.(NOTE: Polymer modified slurry, to be applied before laying of cement mortar bedding shall be measured and paid seperately) |
| 27 | M&L for cleaning the surface thoroughly to remove all dust, dirt, loose particles, oil, and other foreign matter, and applying Single-component aliphatic polyurethane-based liquid-applied waterproof coating having a minimum Solar Reflectance Index (SRI) of 106 on inaccessible roofs, terraces, and parapets in three coats (including one primer coat of the same material diluted with clean water in the ratio recommended by the manufacturer) at specified intervals, applied to achieve the manufacturer’s recommended dry film thickness (DFT), including curing, finishing, and testing, complete all as specified and directed by the Engineer-in-Charge.(MAKE: STP, SHALIURETHANE BTD / SIKA, SIKALASTIC-590 IN / FOSROC, NITOPROOF 725)NOTES:- Dry Film Thickness (DFT):(1) The total dry film thickness (DFT) of the polyurethane waterproofing membrane (excluding the diluted primer coat) shall not be less than 1.2 mm for the complete system (two finish coats), applied in multiple coats as per the manufacturer’s technical data sheet.(2) Wet film thickness (WFT) shall be measured for each coat, and the cumulative WFT shall be converted to DFT using the manufacturer’s solids-by-volume data.(3) The final acceptance tolerance shall be ±10%.(4) In case any manufacturer’s technical data sheet specifies a higher minimum DFT, the higher value shall govern. |
| 28 | PLASTERING, WHITE WASH, DISTEMPERING & PAINTING |
| 29 | M&L for complete removal of existing treatment on old painted surfaces of walls by scrapping andremoving layers of all wall finishes including cleaning, watering to make the surface clean and free from dust, etc incl necessary scaffolding, safety and protective measures complete all as specified and directed. |
| 30 | Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 31 | M&L for Rendering (Internal) 15mm thick in cement mortar 1:6 on Brick Walls or concrete surfaces, finished Even & Smooth without using Extra Cement complete all as specified and directed. |
| 32 | M&L for Rendering 5.0mm thick in cement mortar 1:3 on Concrete Surfaces of Ceilings, Plastered Surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the Ratio 1:1:1 shall be applied and finish Even, complete all as specified and directed. |
| 34 | M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound(as per manufacturer\"s instructions) on external surfaces ofbrick/stone walls or concrete surfaces finished even and fair upto 4 storey height incl necessary scaffloding complete all as specified and directed. Note : Water Proofing compound shall be paid seperately as \"Supply only\". |
| 35 | M&L for preparing newly Plastered surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and directed. |
| 36 | M&L for preparing New/Undecorated Plastered Surfaces of Walls, applying a coat of suitable cement primer followed by a Coat of 2.0 mm thick Wall Putty (in two layers of 1mm thick) including rubbing down with Sand Paper to obtain a smooth finish surface and finishing with Two Coats of Acrylic Distemper (as approved) as per desired shade/tint complete all as specified and as directed. |
| 37 | M&L for preparation of newly plastered surfaces andfinished with two coats ofexterior acrylicemulsion paint (having anti-dust & anti-algae properties) duly mixed with stainer to achieve approved Tint/shade over a coat of suitable exterior primer, applied to new wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer\"s instructions, up to 4 storey height incl necessary scaffolding safety gear etc complete all as specified and directed. |
| 38 | M&L preparing newly Rough Cast plastered surfaces of Walls and applying two Coats of Exterior Emulsion Paint (having anti-dust & anti-algae properties) duly mixed with stainer to achieve approved Tint/shadeover a coat of suitable exterior Primer (as per Manufacturer\"s instructions), complete all as specified and directed. |
| 39 | M&L preparing old decorated/painted Wood and Wood Based Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (1st quality), complete all as specified and directed. |
| 40 | M&L preparing old Treated/Painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and directed. |
| 41 | M&L for preparing old treated/decorated surfaces of ceilings and applying One Coat of White Wash, complete all as specified and directed. |
| 42 | M&L for preparing old treated/decorated surfaces of walls and applying One Coat of White Wash, complete all as specified and directed. |
| 43 | M&L for preparing old treated/decorated surfaces of walls and applying One Coat of Acrylic Distemper, complete all as specified and directed. |
| 44 | M&L preparing old Decorated/Treated Plastered surfaces of Exterior Walls by brooming down or steel wire brushing and scraping down, filling of cracks with suitable pasteand applying One Coat of Exterior Emulsion Paint (having anti-dust & anti-algae properties) with approved Tint, applied with rollers to wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer\"s instructions, upto 4 storey height including necessary scaffloding complete all as specified and directed. |
| 45 | -ditto- but with One Coat of Exterior Emulsion Paint (having anti-dust & anti-algae properties) on old Decorated/Treated Rough Cast Plastered surfaces. |
| 46 | JOINERY, BUILDERS HARDWARE & GLAZING |
| 47 | Resecuring or easing & adjusting without taking down shutters of any description, area exceeding 1.0 sqm but not exceeding 2.0 sqm each complete all as specified and directed. |
| 48 | Taking down Shutters of any description exc 1.0 sqm and not exc 2.0 Sqm each, keeping aside for re-use or removal from site complete all as specified and directed. |
| 49 | Refixing of Shutters of any description, area exc 1.00 Sqm and not exc. 2.00 Sqm Each after resecuring or easing and adjusting complete all as specified and directed. |
| 50 | Taking down damaged / unserviceable Steel / Wooden Chowkat or Frame exc. 1.50 Sqm but not exc. 4.00 Sqm Each with shutter(without taking off shutter from the frame) and removal from site incl cutting holes in brickwork for removal of holdfasts complete all as specified and directed. |
| 51 | -ditto- but for Steel / Wooden Chowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 52 | -ditto- but for PVC Chowkat or Frame not exc 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed. |
| 53 | Hacking out old broken Glass (any thickness, size, quality or description) from Metal Frames, glazed with putty or fixed with beads, complete all as specified and directed. |
| 54 | M&L for Securing glass of any description in existing metal frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New length of frame reputtied shall be measured) complete all as specified and directed. |
| 55 | Taking down old AluminiummChowkat or Frame exc. 1.50 Sqm but not exc. 4.00 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed. |
| 56 | Taking down old AluminiumChowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed. |
| 57 | S&FPre-Painted Galvanised Steel Frame of size 105x60mm using 1.25mm thick Mild Steel Sheets for Doors with One or More Rebates including providing necessary Fixing Lugs, Hinges, Lock Strike Plate, etc., complete all as specified and directed. |
| 58 | S&F Pre-Painted Galvanised Steel Frame of size 125x60mm using 1.25mm thick Mild Steel Sheets for Doors with One or More Rebates including providing necessary Fixing Lugs, Hinges, Lock Strike Plate, etc., complete all as specified and directed. |
| 59 | M&L Cement Concrete 1:3:6 type C0 (12.5mm graded stone aggregate) as in Filling Back side of Chowkats and for filling holdfast holes in brickwork finished even and smooth complete all as specified and directed. |
| 60 | S&F factory made single extruded WPC (Wood Polymer composite) solid door / window / ceosetory windows & other frames / chowkhat of size 50 X 75 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 grams) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N(Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with mild steel hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed.(NOTE: MS hold fast/lugs or SS dash fasteners shall be paid for seperately. For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made) |
| 61 | -ditto- but WPC frame of size 100 x 50 mm single rebated type |
| 62 | -ditto- but WPC frame of size 125 x 65 mm double rebated type |
| 63 | S&F Butt hinges, 100mm long, stainless steel with brass/SS screws complete all as specified and directed. |
| 64 | S&F Aluminium alloy Handle 125mm long, cast type, anodised with brass/SS screws complete all as specified anddirected. |
| 65 | S&F Aluminium alloy Handle 150mm long, cast type, anodised with brass/SS screws complete all as specified anddirected. |
| 66 | S&FAluminium Barrel Tower Bolt 150 mm long, extruded section, with brass/SS screws complete all as specified and directed. |
| 67 | S&FAluminium Barrel Tower Bolt 200mm long, extruded section, with brass/SS screws complete all as specified and directed. |
| 68 | S&FAluminium alloy, anodized, Sliding Door Bolt 250mm long with Hasp Staple (Bolt type) and Fixing Clips of Sheet cast or extruded section and fixing Bolts and Sliding Bolts of extruded section and fixing, with brass/SS screws complete all as specified and directed. |
| 69 | S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and shall be fixed with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified & directed.(Note: Butt hinges and necessary S.S screws shall be paid separately) |
| 70 | -ditto- but for 35 mm thick WPC flush shutter |
| 71 | Providing and fixing 30 mm thick WPC skeleton door shutter with WPC stiles and rails, including beading for fixing the outer-face SS-304 woven mosquito mesh (wire dia 0.56 mm, aperture 1.18 mm), and providing on the inner face an expanded aluminium grill (AA 3003/5052, 1.0 mm thick, 10–12 mm opening) fixed within the frame using aluminium U-channel and SS screws; all SS–aluminium contact points isolated with 2 mm neoprene/PVC strip; complete all as directed by the Engineer-in-Charge.NOTE: All materials, wire mesh, aluminium grill, beading, channels, accessories, fixings and labour required for complete installation shall be deemed to be included in the quoted rate and nothing extra shall be paid on any account. |
| 72 | S&F Door Spring of Mild Steel 300mm long, Ordinary Rat Tail type, Rod pattern Springs incl Roller and Roller Plate welding with frame, etc., with brass/SS screws complete all as specified and directed. |
| 73 | S&F Floor Door Stopper 150mm in size, Aluminum alloy Body and Tongue with Hard Drawn Steel Spring (weight not less than 90 Gram), with brass/SS screws complete all as specified and directed. |
| 74 | Taking down aluminium Shutter of any description, area exc 1.00 Sqm and not exc. 2.00 Sqm Each and Refixing in the Same Opening, after resecuring or easing and adjusting, etc. including re-fixing of glass sheet and replacement of necessary Jointing Cleats, Glazing Clips, Rubber Neoprene Packing, Screws, etc. and repairing of Locking Arrangement if any, complete all as specified and directed.NOTE : Cost of Materials requiredfor smooth functioning of Shutter shall deem to be included in the Quoted Unit Rate. Locks and glass sheet, if required to be replaced shall be measured seperately under respective items. |
| 75 | S&Fin repair Mild Steel Mortice Lock 100mm in size, 4-Lever, Vertical type, complete all as specified and directed. |
| 76 | S&F in repair Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick Aluminium alloy Sheet Foundation Box, Main Body with Stainless Steel Cover, Governing Pivot made of Brass, Other Parts made of Mild Steel heavy duty complete all as specified and as directed. |
| 77 | S&F in repair Door Closer Aluminium (Die cast) body, hydraulically regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in width and of weight between 61.00 to 80.00 Kilogram complete all as specified and directed. |
| 78 | S&F in repairs Stainless Steel Curtain Rod 25mm dia/bore(as approved) includingfixing stainless steel Bracket (shaped as approved) not less than 80mm longto wall with Screws/ securedwith stainless steel side doom(as approved) fitted/tightened on Curtain Rod at both ends with screw, complete all as specified and as directed.Note : Cost of brackets and end caps shall deemed to be included in the quoted rate. |
| 79 | S&F aluminium alloy powder-coated aluminium glazed door with side-hung shutters, including glazing with 5.50 mm thick tinted glass fixed with rubber gasket, aluminium beading and glazing clips, complete all as specified and as directed, comprising the following:-(a) Frame: 100 × 44 × 1.48 mm thick aluminium box section, fixed to masonry / RCC with rawl plugs, screws etc., complete.(b) Middle and Lock Rail: 150 × 44 × 1.48 mm thick aluminium box section.(c) Top Rail and Stiles: 85 × 44 × 1.48 mm thick aluminium box section.(d) Aluminium Beading: 0.70 mm thick.(e) Making Good: Making good the wall surface to match the existing finish, complete.NOTES:(1) Quoted rate shall be deemed to be inclusive of the cost of all aluminium sections, powder coating / anodising, glazing clips, rubber gasket / packing, anodised aluminium snap-on beading for fixing glass panes, fasteners, fixtures, labour, tools, and all incidental works necessary for completion of the item.(2) Door floor spring, mortice lock, and door closer and Sheet Glass shall be measured and paid for separately. |
| 80 | S&F aluminium alloy powder-coated aluminium sliding window, three-track type, with movable shutters sliding on a minimum of two PVC rollers of approved quality per shutter, including one glazed shutter and one stainless steel mosquito-proof shutter, complete all as specified and as directed, comprising the following:-(a) Window Frame: 75 × 35 × 1.48 mm thick aluminium section, complete.(b) Shutter Members (Top / Bottom Rails and Stiles): 38 × 19 × 1.48 mm thick aluminium section or heavier.(c) Aluminium Beading / Glazing Clips: 0.70 mm thick.(d) Stainless Steel Wire Cloth: 0.45 mm nominal diameter of wire with average aperture width of 1.40 mm, fixed in aluminium frame or with F/Y section, secured with aluminium fire staples, complete.(e) Aluminium Fittings: Aluminium handles suitable for sliding shutters with auto-interlocking closing arrangement, complete.(f) Making Good: Making good the wall surfaces to match the existing finish, complete.NOTES:(1)Quoted rate shall be deemed to be inclusive of the cost of all aluminium sections, powder coating / anodising, stainless steel mosquito wire mesh, PVC rollers, glazing clips, rubber / neoprene gasket, anodised aluminium snap-on beading for fixing glass panes, aluminium fittings, fasteners, fixtures, labour, tools, and all incidental works necessary for completion of the item.(2)Sheet glass shall be measured and paid for separately. |
| 81 | S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.NOTE:- Weight of grill shall be worked out based on the actual weight of gill as found on site. |
| 82 | Providing and fixing replacement of defective / damaged automatic door sensor for automatic sliding / swing door, including supply of new sensor (microwave / infrared / presence detection type as required), compatible with the existing automatic door operator and control system, complete with mounting brackets, wiring, connectors, calibration and testing. The work shall include dismantling and safe removal of the existing faulty sensor, making good disturbed surfaces, integration with existing power supply and control unit, alignment, sensitivity adjustment, commissioning, and functional testing to ensure smooth and safe door operation, complete all as specified and as directed by the Engineer-in-Charge.NOTES:(1) The quoted rate shall be deemed to include cost of sensor, accessories, labour, tools & plants, testing and commissioning.(2) Make of Sensor shall be as per OEM or as approved by GE.(3) The work shall be carried out by trained and experienced technicians conversant with installation, calibration, and commissioning of automatic door systems. The contractor shall ensure correct integration with existing control panels and safety devices. The quoted rate shall be deemed to include the cost of such specialised labour. No extra payment shall be made on this account.(4) No extra payment shall be made for dismantling or minor civil / electrical adjustments required for installation.(5)Warranty for the replaced sensor shall be as per manufacturer’s standard. |
| 83 | S&F Sheet Glass 5.50 mmthick, Tinted (as approved by GE), fixed to Aluminium Windows of size exc 0.50 sqm each pane complete all as specified and directed. |
| 84 | S&F Sheet Glass 4.80 mmthick, Tinted (as approved by GE), fixed to Aluminium Windows of size exc 0.50 sqm each pane complete all as specified and directed. |
| 85 | S&F Plain Sheet Glass4.0mmthick, Ordinary quality and glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and directed. |
| 86 | S&F Frosted Sheet Glass4.0mmthick, Ordinary Type and glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and directed. |
| 87 | REPAIRS TO CEILINGS, WALL PANELLING & FALSE CEILING |
| 88 | Dismantling of false ceiling grid, any type including ceiling board of any thickness, keeping aside properly for reuse or removal from site complete all as specified and directed. |
| 89 | Dismantling of wall boardas in lining, panelling, cupboard/cabinet doors & shelves etc, of any size or any thickness including cover fillets complete all as specified and directed. |
| 90 | S&F wall panelling with hollow 5 mm thick PVC panels of 10\"/12\" width and any height, single side pre-laminated with flat or fancy patterned on laminated side, fixing on walls with screws or with solvent cement as required on site including necessary corner angles, fillets etc as required at site complete all as specified and directed. |
| 91 | S&F 18 mm thick HDHMR (High Density High Moisture Resistant) waterproof pre-laminated board for cupboard shutters, cut to size and fixed complete, including providing and fixing stainless steel SS 304 grade auto-concealed cabinet hinges (zero-degree), full overlay type, of adequate size, minimum 02 Nos. per shutter, fixed with cabinet hinge repair plate, stainless steel silver chrome finish door handle 100 mm long (01 No. per shutter) and 150 mm long safety type hasp and staple, brass with mild steel hinge pin, complete with all screws, fittings, labour, wastage and incidental works, complete all as specified and as directed by the Engineer-in-Charge.NOTE: Quoted unit rate shall be inclusive of shutter board, hinges, handles, hasp & staple, screws, accessories and labour, complete. |
| 92 | S&F 16 mm thick HDHMR (High Density High Moisture Resistant) waterproof pre-laminated board for internal partitions, shelves and carcass of cupboards, cut to required sizes and fixed in position with approved screws, cleats, shelf pins and fittings, including all necessary supporting members, labour, materials, wastage and incidental works, complete all as specified and as directed by Engr-in-Charge.NOTE: Quoted unit rate shall be inclusive of HDHMR board, fixing accessories, screws, labour and all incidental works, complete. |
| 93 | S&F false ceiling with powder coated exposed G.I. grid suspension system consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle, wall angle fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c, Main Runners placed @ 1200mm, Cross Tee 1200mm inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm and additional cross tees of 600 mm placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm, grid of module size 600mm x 600mm shall be supported by Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. Note: Ceiling board will measured and paid separately under appropriate item. |
| 94 | S&F 16 mm thick mineral fibre ceiling tiles, ofdimension 595x595mm with humidity resistance 99% Thermal conductivity K = 0.052-0.057 w/mK, colour white, fire performance UK Class 0/Class 1 (BS 476 pt-6&7) suitable for green building application (GRIHA Criteria 17 & 29 SWAGRIHA 12) with recycled content not less than 30 % and light reflectance not less than 85% and NRC of 0.55 to 0.6 duly fixed on GI Snap Grid Frame Work with Steel Screws complete all as specified and directed.Note: Snap grid ceiling frame shall be measured separately under appropriate item. |
| 95 | Providing and fixing PVC false ceiling with hidden GI framework and S&F wall panelling with hollow 5 mm thick PVC panels of 10\"/12\" width and any height, single side pre-laminated with flat or decorative patterned finish on the laminated side, fixed to walls using screws or solvent cement as required at site, and laid or clipped on a hidden GI framework of approved quality, 0.5–0.8 mm thick for main channels and cross members, spaced as approved by the Engineer-in-Charge to ensure rigidity and level ceiling finish, including provision of necessary corner angles, fillets, trims, edge profiles, jointing, alignment, leveling, and all accessories required for a neat, continuous, and rigid finish, complete with cutting, shaping, fixing of panels, cleaning, and protection till completion, all as specified and directed by the Engineer-in-Charge, with all materials, labour, tools & plants, framework, adhesives, fasteners, wastage, scaffolding, and incidental works deemed to be included in the quoted rate. |
| 96 | M&L for repairing spalled / damaged concrete surfaces in RCC members (slabs, beams, columns, ceilings, etc.) with polymer-modified repair mortar and associated materials, complete as directed by the Engineer-in-Charge. The work shall be executed in the following steps:(a)Step 1 (Marking and Cutting) :- Mark the damaged / spalled area in a regular shape (square or rectangular) and cut the edges to a depth of at least 10–15 mm using a chisel or mechanical cutter to expose sound concrete and reinforcement, avoiding feather edges.(b) Step 2 (Removal and Cleaning):- Remove all loose, delaminated, and unsound concrete. Clean the surface thoroughly using wire brushes, compressed air, or water jet to remove dust, laitance, and loose particles.(f) Step 6 (Bonding Coat):- Apply a bonding coat of approved bonding agent (e.g., polymer latex / epoxy bonding agent) on the prepared concrete surface. Repair mortar shall be applied while the bonding coat is still tacky. (g)Step 7 (Application of Repair Mortar) : Rebuild the damaged area with polymer-modified repair mortar (pre-packed, non-shrink, approved brand) or micro-concrete for larger or deeper repairs, restoring the original profile and level. (h)Step 8 (Fixing of Chicken Mesh) :Provide and fix chicken wire mesh (12.5 mm × 22 SWG, hexagonal type) over the affected area, fixed with nails or screws at suitable spacing to ensure proper anchorage with the surface. (j) Step 9 (Application of Polymer Modified Mortar (Finishing Coat):- Apply 10–12 mm thick polymer-modified mortar (PMM) over the chicken mesh, finished even and smooth to match adjoining surfaces, following manufacturer’s instructions for mixing and application. (k) Step 10 (Curing and Cleaning):- Cure the repaired surface properly for a minimum of 7 days using wet curing or curing compound. Clean the site of all debris, droppings, and restore to a neat condition.NOTES :- (1) The work and mix proportion of items shall be carried out strictly as per manufacturer\"s recommendations. contd.... |
| 97 | Item No 6.09 (Contd...):-NOTES :- (2) Contractor shall submit details alongwith technical literature of various items required for the job for prior approval of GE.(3) Contractor shall procure the materials from authorised dealer or manufacturer and submit purchase voucher accordingly. (4) Quoted rate shall deemed to include for all consumbles, T&P, scaffolding and safety gear required for satisfactory completion of the job.MAKES:-1) RUST REMOVER AGENT -FOSROC, REEBAKLENS RR / STP, SHALIRUSTOFF / SIKA, RUSTOFF 1002) EPOXY PRIMER -FOSCROC, NITOZINC / STP, SHALIPRIME Zn R / SIKA, FERROGARD 950 IN3) BONDING AGENT -FOSROC, NITOBOND / STP, SHALIBOND CONCRETE / SIKA, SIKADUR-32 IN4) MICRO CONCRETE - FOSROC, RENDEROC RG / STP, SHALIFIX MC / SIKA, SIKAREP MICROCRETE-45) POLYMER MODIFIED MORTAR - FOSROC, RENDEROC S2 / STP, SHALIFIX FRM 40 / SIKA, SIKATOP-122 HS |
| 98 | REPAIRS TO SUNKEN FLOORS |
| 99 | Demolition of Cement Concrete (un-reinforced) in Toilet Floors, Sunken Floors including taking out floor tiles, PCC, mortar of any description including raking out joints, hacking for key, scrubbing down with water and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed. |
| 100 | M&L for applying comprehensive waterproofing treatment to sunken floor areas of toilets, baths, and similar wet locations, including all materials, labour, and equipment, complete as per specifications and direction of the Engineer-in-Charge and comprising the following operations carried out in sequence:-(a)Step 1 (Surface Preparation):- Clean the entire sunken floor area and adjoining walls of all loose materials, laitance, dust, grease, oil, and any foreign matter. Cut and repair cracks, honeycombs, and voids using polymer-modified repair mortar or crack filler paste as directed by the Engineer-in-Charge. Ensure the surface is sound, even, and free from standing water before proceeding.contd..... |
| 101 | Item No 7.02 (contd....) (b) Step 2 (Fillet Formation):-Provide and form a 45° fillet (coving) at the junction of floor and wall all around the periphery using Polymer Modified Mortar (PMM) (Cement : Sand = 1:3, with polymer additive/SBR Latex). Ensure smooth finishing and proper bonding with both wall and floor surfaces.(c) Step 3 (Priming/Bond Coat):-Apply one coat of polymer-modified cement slurry over the complete area, including all joints and fillets. The mix proportion shall be Cement : Polymer : Water = 1 : 0.4 : 1 by weight. Allow the surface to become tacky before proceeding with waterproofing coats.(d) Step 4 (Cementitious Waterproofing Coating):-Apply two coats of cementitious waterproofing slurry (Cement + approved polymer such as SBR / Acrylic Latex) over the entire sunken floor and extend it 300 mm up the adjoining walls. The second coat shall be applied at right angles to the first after allowing the first coat to air-dry for 4–6 hours. Ensure uniform coverage and film thickness as per manufacturer’s recommendation.(e) Step 5 (Provn of GI spout pipe):-Provide and fix a 40 mm dia medium-class G.I. pipe spout at the lowest point / lateral slope, projecting at least 250 mm beyond the outer most face of the wall, positioned below the floor drain pipe. Seal the joint around the pipe using polymer-modified mortar / non-shrink grout / epoxy sealant, ensuring water tightness. Maintain an outward slope of 1:20 for safe drainage of any trapped seepage water. (f) Step 6 (Protective Plaster/Screed):- After the waterproofing coat has air-dried, apply a protective cement mortar layer (1:3) mixed with SBR Latex (10% by weight of cement): => Horizontal surfaces: 20 mm thick=> Vertical surfaces: 15 mm thickMaintain a proper slope of 1:60 to 1:80 towards the floor drain. Ensure uniform thickness and dense, smooth finish.(g) Step 7 (Curing):- Cure the completed waterproof coating and protective plaster for a minimum of 7 days, using water sprinkling or wet hessian cloths as directed by the Engineer-in-Charge. Prevent direct sunlight or mechanical damage during curing.contd......... |
| 102 | Item No 7.02 (contd....) (h) Step 8 (Pond Testing):- After curing, conduct a pond test by retaining water over the treated surface for a minimum period of 48 hours. Check for any signs of leakage or dampness on the underside or adjacent walls. If leakage is observed, identify the source, rectify the defect, and retest until satisfactory watertightness is achieved. NOTES :- (1) The work and mix proportion of items shall be carried out strictly as per manufacturer\"s recommendations. (2) Contractor shall submit details alongwith literature of various items required for the job for prior approval of GE. (3) Quoted rate shall deemed to include for all consumbles, T&P, scaffolding and safety gear required for satisfactory completion of the job. (MAKE OF ITEMS : SUITABLE PRODUCTS IN FOSROC / STP / SIKA / DR FIXIT) |
| 103 | M&L for cement concrete 1:5:10 type E-2 ( using 40 mm graded stone aggregate) in sunken portion of slab, complete all as specified. |
| 104 | M&LCement Concrete 1:2:4 type B0 (12.5mm graded stone aggregate) 25mm thick in Sub-base for laying of Tiles in Floor, complete all as specified and directed. |
| 105 | REPAIRS TO FLOORING & TILING WORKS |
| 106 | M&L for Dismantling Stone Slabs and/or Tiles of any description or thickness in Floors, Aprons, etc. laid, bedded and pointed in Cement Mortar, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water complete all as specified and directed. |
| 107 | M&L for providingGranite (of any type) Slab, 16-18mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement and admixture of pigment to match the shade of granite stone including edge moulding, grinding and polishing, laid over and including 20 mm thick screed bed in cement mortar (1:4), laid in any position / location complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall deemed to be included in the quoted rate. |
| 108 | -ditto- but for Granite (of any type) Tiles, 12-14mm thick machine cut, in skirting/dado, fixed over and including 10mm thick cement screed (1:4) and jointed with grey cement slurry, and pointed with white cement and admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall deemed to be included in the quoted rate. |
| 109 | M&L for providingMachine cut Pre-Polished Kota Stone Tiles, 18-20mm thick in Flooring, laid over including 20mm thick screed base of cement mortar 1:6 and joined with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall be deemed to be included in the quoted rate. |
| 110 | -ditto- but for Machine cut Kota Stone Tiles 16-18mm thick, in Riser of Steps, Skirting, Dado and Pillar, joined with grey Cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, fixed over and including 10mm thick cement screed (1:4) complete all as specified and directed..NOTE : Cost of Cement Screed Bed shall be deemed to be included in the quoted rate. |
| 111 | Dismantling Floor, Paver Tiles, Hearth or Wall Tiling,etc. including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 112 | M&L for providing Non-skid/matt finish Ceramic tiles, coloured, joint free,7-8 mm thick (Square / rectangular), area of each tile exceedig 0.18 Sqm but not exceeding 0.38 Sqmin Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the tiles, laid over and including Screed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 113 | -ditto- but for non-skid/matt finish ceramic tiles (area of each tile exceedig 0.18 Sqm but not exceeding 0.38 Sqm) in skirting, fixed over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 114 | M&L for providing Non-skid/matt finish Ceramic tiles, coloured, joint free,7-8 mm thick (Square / rectangular), area of each tile exceedig 0.11 Sqm but not exceeding 0.18 Sqmin Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the tiles, laid over and including Screed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 115 | M&L for providing Coloured/Printed Glazed Ceramic Tiles, 450x300x6.5-7mm thick in Vertical Surfaces i.e. Dado, Skirting, etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, fixed over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:3, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 116 | Providing and fixing glazed ceramic mosaic tiles conforming to relevant IS / international standards, suitable for underwater and swimming pool applications, of approved colour, shade and pattern, having low water absorption (≤0.5%) and chemical resistance including resistance to sodium hypochlorite / chlorine normally used for swimming pool disinfection, without deterioration, staining or loss of surface finish, laid in chip size not less than 20 mm and not more than 50 mm, as approved by the Engineer-in-Charge, factory mesh-mounted sheets of approx. 300×300 mm, thickness not less than 5–6 mm, fixed over properly prepared and waterproofed pool surfaces using polymer-modified cement-based tile adhesive suitable for submerged conditions, including cutting, shaping, setting out, true to line, level and plumb, and filling and sealing of all joints (1.5–3 mm) with two-component epoxy-based waterproof grout resistant to chlorine, pool chemicals, staining and fungal growth, including cleaning of surface, curing, protection till completion, and making good adjacent surfaces, complete all as specified and as directed by the Engineer-in-Charge, with all materials, labour, tools & plants, adhesives, epoxy grout, leads, lifts, scaffolding, wastage and incidental works deemed to be included in the quoted rate. |
| 117 | REPAIRS TO PLUMBING & SANITARY WORKS |
| 118 | Taking up or down water supply tubing, any type, 15/20mm bore (dia) with accessories, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and directed. |
| 119 | Taking down of PVC water tanks, over roofs, of capacity 500 to 1000 litres, after disconnecting all water connections, float valves, dewatering, plugging the pipes and keeping aside the tanks in safe custody for removal or re-fixing after water treatment of surfaces complete all as specified and directed. |
| 120 | S&F Chlorinated Polyethylene Chloride (CPVC) pipes 20 mm outside dia, SDR-11, having thermal stability for hot and cold water supply incl all SDR-11 CPVC plain and brass threaded fittings (such as Bends, Elbows, Tees, Short Pieces, Connectors, Back - Nuts Caps, Plugs, Unions, Flange (core) & flange (ring), reduction Tee, reducing socket, Male & female threaded socket, tank connectoretc) fixed/laying walls, ceilings or in floors etc.with suitable size MS clamp of spacing 1.00 mtr etc pipe line complete all as specified & directed. |
| 121 | -ditto- but with 25 mm outer dia size CPVC pipes |
| 122 | M&L Cleaning and removing all Scales and dirts from inside of PVC water tanks, of capacity exc. 250 Litre and not exc. 500 Litre, by scrubbing the deposits with Wire Brush, bleaching powder, etc, including re-fixing the tanks in same position and re-connecting all water lines & float valve incl writing Letters \"CLEANED ON DD.MM.YYYY\" (i.e. Date of Cleaning of Tank) not exc. 50mm in height and testing complete complete all as specified and as directed. |
| 123 | -ditto- but for tanks of capacity exc. 500 Litres and not exc. 1000 Litres |
| 124 | S&F Rotational Moulded Polyethene Water Storage Tank, 1000 Litre Capacity, Cylindrical, Vertical type with Closed Top, 3 layered, conforming to IS, hoisted and fixed in Position alongwith GI tank nipple and tank lid incl testing complete all as specified and directed. |
| 125 | S&F Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe, complete all as specified and directed. |
| 126 | S&F in repairs angle valve, 15 mm bore, cast copper alloy, chromium plated fancy type, minimum weight 300 grams, with wall flange fixed to iron pipe complete all as specified and directed. |
| 127 | S&F in repairs Chromium plated brass Pillar tap, with aerator, minimum weight 550 grams, fixed to WHB complete all as specified and directed. |
| 128 | S&F in repairs Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, ShortBody with Capstan Head, minimum weight 400 grams, screwed down, screwed for Iron Pipe or for Brass Ferrule, complete all as specified and directed. |
| 129 | S&F in repair 15mm bore chromium plated single lever central hole basin mixer without popup waste system with 450mm long copper pipe and brass nut, minimum weight 700 grams complete all as specified & directed. |
| 130 | S&F in repair Chromium plated brass bodyWall mixer, with concealed body, with overhead shower arrangement fixed with 15 mm bore Iron pipe complete all as specified and directed. |
| 131 | S&F in repair Automatic Brass Sensor Tap(Touch Less Hand Free Sensor Tap) for Wash Basin includingFoam Flow Water, 5 Inch Height. AC and Battery Operated (Cold Only), PVC connection etcand fixed with all accessories in 15mm dia bore pipe completeall as specified and directed. |
| 132 | S&F in repair chromium plated Hand shower (health faucet), ABS body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed. |
| 133 | S&F in repair Vitreous China White Squatting Pan of size 580x440mm, \"Orissa\" Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) incl provision of Lime Concrete Bedding and Making Good to Floor/distrubed surfaces, complete all as specified & directed. |
| 134 | S&F in repair PVC Connection Pipe 15mm size and 60 Cm in length with Adapter Nuts of PVC, complete all as specified and directed. |
| 135 | S&F in repair 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and incl with flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. |
| 136 | S&F in repair Vitreous China Wash Hand Basin 450x300mm in size, White (Flat Back or Angle Back Type), provided with 32mm dia Brass Chromium Plated Waste Fitting, PVC waste pipe, brackets incl making good disturbed Surfaces in Cement Mortar 1:3 and filling joints with whte cement complete all as specified and directed.(NOTE: Cost of CP wate coupling and PVC waste pipe is deemed to be incl in the quoted rates) |
| 137 | -ditto- but for Vitreous China Wash Hand Basin 550mm x 400mm in size, white, Flat BackType, complete |
| 138 | S&F in repair chromium plated brass over head shower rose (125 mm dia) with arm, with 3 flow, minimum weight 450 grams, fixed to 15mm bore of iron pipe complete all as specified and directed. |
| 139 | S&F in repairs PTMT Towel Rail (minimum weight 190 grams), fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 140 | S&F in repairs Brass Chromium Plated Tubular Towel Rail, 60 Cm long with Brackets, total weight not less than 300 grams complete all as specified and directed. |
| 141 | S&F in repair Mirror 900x600mm in size, Beveled Edge of Selected quality Glass, fixing with Brass Chromium Plated Knobs/Spacers 25mm to 30mm size (One Each in Corner), complete all as specified and directed. |
| 142 | S&F in repair Grating 100mm dia in size, Chromium Plated complete all as specified and directed. |
| 143 | S&F in repair acrylic Shelf (Bath Tray), 600 mm long or Corner Shelf, size 30 cm alongwith all accessories complete all as specified and directed. |
| 144 | S&F inrepairs for waste coupling chromium plated for sink / wash basin, suitable for 32mmdia waste pipe complete all as specified and directed.(NOTE: This item shall only be measured for replacement in existing sinks, basins etc) |
| 145 | S&F in repair PVC Waste Pipe 32mm bore (dia), 60-75 cm length (as required at Site), complete all as specified & directed. (NOTE: This item shall only be measured for replacement in existing sinks & basins) |
| 146 | S&F in repair PVC (SWR) 75 mmfloor trap plain with grating including jointing to waste pipe, fixed in cement concrete 1:2:4 (20 mm graded stone aggregates) complete all as specified and directed. |
| 147 | S&F in repairs PVC (SWR) 75mm OD Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid onfloor, trench etc or fixed to Walls with PVC clips complete |
| 148 | S&F in repairs PVC (SWR) 110mm OD Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid onfloor, trench etc or fixed to Walls with PVC clips complete. |
| 149 | S&F in repair PVC (SWR) 75mm OD, Bend any type, provided with Access Door, etc. and jointing with Solvent Cement, complete all as specified and directed. |
| 150 | S&F in repair PVC (SWR) 110mm OD, Bend any type, provided with Access Door, etc. and jointing with Solvent Cement, complete all as specified and directed. |
| 151 | S&F in repair 75 mm bore PVC (SWR) junction single (single T) equal or unequal, with access door complete all as specified and directed. |
| 152 | S&F in repairs 110 mm bore PVC (SWR) junction single (single T) equal or unequal, with access door complete all as specified and directed. |
| 153 | S&F in repair PVC (SWR) vent cowl, 75 mm bore complete all as specified and directed. |
| 154 | REPAIRS TO MS WORK & ROOFING |
| 155 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and removal from sitecomplete all as specified and as directed. |
| 156 | Dismantling wrought iron or mild steel work of any description in rafters, purlins and wind ties wtc and removal from site complete all as specified and directed. |
| 157 | M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 158 | M&L preparing new or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and directed. |
| 159 | S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high/multi rib profile having 1000–1020 mm effective width, 28–30 mm high crest at 250–255 mm pitch (centre), manufactured from high tensile galvalume sheets of 550 MPa tensile strength with coating comprising 18–20 micron top coat, 5 micron primer and 8–10 micron alkyld backer zinc-aluminium alloy (AZ-150) with total mass 150 g/m² on both sides, sheets having wide pans with minimum three small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support, fixed as per the existing profile using self-tapping screws, fasteners, and all necessary accessories, including overlaps and supports, complete, all as specified and directed by the Engineer-in-Charge. |
| 160 | -ditto- but 0.50 mm thick colouredplain galvalume sheet as in ridge/valley gutter of roof. |
| 161 | COMMON NOTES TO ITEM NO 10 AND SUB ITEMS THEREOF:- (1) The quoted rates shall be deemed to include the cost of all tools and plants (T&P) such as scaffolding, ladders, ropes, welding and cutting equipment, drilling machines, safety harnesses, lifelines, helmets and all other necessary safety gear and protective measures required for execution of the work at all heights, including working at heights up to 15 metres above ground level or as actually required at site.(2) The quoted rates shall also be deemed to include all fixing accessories, consumables and incidental items such as self-drilling screws with EPDM washers, G.I. anchor bolts, nuts, bolts, cleats, screws, rawl plugs, sealants, welding electrodes, fasteners and all other materials required for proper completion of the work in all respects, including incidental cutting, drilling, welding, removal of minor welded or bolted connections, safe lowering, stacking and removal of dismantled materials from site.(3) The contractor shall ensure adequate safety arrangements for all personnel engaged in the work and shall be solely responsible and liable for the safety of his workmen during execution, dismantling or installation operations. The Department shall bear no responsibility for any accident, injury or loss of life, and the contractor shall indemnify the Department against all such claims or damages.(4) In case the planned MS structure, truss, grill, purlin, bracing, roofing arrangement or similar work differs from the existing structure, proper measurement of the existing structure to be dismantled shall be recorded in the Measurement Book (MB) duly signed by the Engineer-in-Charge. |
| 162 | REPAIRS TO PLINTH PROTECTION, FOOTPATH & OTHER PAVED AREAS |
| 163 | Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 164 | M&L for Cement Concrete 1:3:6 type C1 (20mm graded stone aggregate) 75mm thick as in Plinth Protection, finishing surfaces Even and Smooth without using Extra Cement complete all as specified & directed. |
| 165 | M&L for Cement concrete, 75mm thick, type D- 2, 1:3:6 (40mm graded aggregate) in sub floors, sub bases, pavings etc., complete all as specified and as directed. |
| 166 | M&L for providing rubber moulded cement concrete coloured chequered tiles 300x300x22-25mm thick, set, jointed and pointed in neat cement slurry in floors, with grey cement and pigment, laid over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and directed. NOTE : Quoted rate shall deem to include the cost of cement screed bed. |
| 167 | Supply and laying machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed. (NOTE: Sand for cushioning level will be measured and paid seperately) |
| 168 | M&L for sand cushioning with clean river sand duly clear of residual, organic and deleterious materials spread evenly to uniform thickness over PCC Sub Base complete all as specified and directed. |
| 169 | M&L for Cement Concrete 1:2:4 type B1 (20mm graded stone aggregate) as in Coping, Bed Plates, Holdfast, Bed Block, Kerb Stonesincluding necessary Formwork and weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail