| 1 | Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc,disposal of unservicable rubbish outside the premises as per policy laid down by UT Chandigarh area all as specified and directed by Engineer-in-Charge. |
| 2 | Taking down existing bitumen felt roof treatment including cement mortar bedding& scrubbing down with water,cleaning the surface etc,disposal of unservicable rubbish outside the premises as per policy laid down by UT Chandigarh area all as specified and directed by Engineer-in-Charge. |
| 3 | Cutting of tree branches/tree roots from wall and felling of trees not exc 30 cm girth,repairing dismantled portion of wall with cement mortar /concrete and making good with existing surfaces and removing the tree /branches etc,disposal of unservicable rubbish outside the premises as per policy laid down by UT Chandigarh area all as specified and directed by Engineer-in-Charge. |
| 4 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc complete all as specified and directed by Engineer-in-Charge. |
| 5 | Taking down steel tubing and connections of 15 mm bore in pipe with all fittings from walls,ceilings and floors and removal from sitecomplete all as specified and directed by Engineer-in-Charge. |
| 6 | Taking down steel tubing and connections of 20 mm bore in pipe with all fittings from walls,ceilings and floors and removal from sitecomplete all as specified and directed by Engineer-in-Charge.. |
| 7 | Dismantling existing Brick tiles or terracing tiles, single layer on roofs includingdisposal of unservicable rubbish outside Cantt area complete all as specified and directed by Engineer in Charge. |
| 8 | Demolition ofMud phuska in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) in any position including disposal of unservicable rubbish outside Cantt area complete all as specified and directed by Engineer in Charge. |
| 9 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc,applying a coat of cement slurry @ 3 Kg/sqm on roofsurface and Rendering 10 mm thick in cement mortar 1:3 onfair faces of brickwork or concrete surfacesfinished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instructions complete ( WPC shall be measured and paid separately )all as specified and directed by Engineer-in-Charge. |
| 10 | Disconnecting existing tanks of capacity exc 500 ltrbut not exc 1000 ltr ,setting aside (or loweringif required)for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position including cleaning,removing all scale and dirt etcfrom tankscomplete all as specified and directed by Engineer-in-Charge. |
| 11 | Cutting grooves or rebates in parapet walls 75 mm wide and 65 mm deep and making good in cement mortar 1:3 after inserting APP membrane and shaping horizontal face of groove complete all as specified and directed by Engineer-in-Charge. |
| 12 | Disconnecting existing tanks of capacity exc. 500 ltr & n. exc. 1000 ltr, setting aside and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 13 | Plain cement concrete1:2:4 type B-0using 12.5mm graded crushed stone aggregate as in cement concrete in roof padding, roof kerbs or mud stops,back filling of chowkats, holdfasts,coping,bed plates,cills,benching rounded or chamfered on edges with and including using necessary use and waste of formwork for fair finished surface complete all as specified and directed by Engineer-in-Charge. |
| 14 | Water proofing roof treatment/Sunken treatment using APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqmblack finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm over cleaned surface including parapet,applying a coat of blown bitumen 85/25 grade @ 1.2 kg per square metre over priming coat torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side and 150 mm at the ends and sealingall as per manufacturers instructions incl wire brushing and cleaning the top surfaces of concrete, roof surfacesetc. with water including flashings and junction of parapets etc complete all as specified and directed.The rates shall be inclusive of finishing rain water gutter portionwith cement mortar 1:3 to provide requisite slope towars rain water pipe outlet. |
| 15 | Heat Resistant Terrace Tiles (200 mm x 200 mm x 20 mm) with SRI(solar refractive index) > 78, solar reflection> 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed. |
| 16 | Brickworkwith fly ash bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radiusbuilt in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 17 | Rendering 10 mm thick in cement mortar 1:6 onother than fair faces of brickwork or concrete surfacesfinished even and fair without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Rendering 15 mm thick in cement mortar 1:4 onfair faces of brickwork or concrete surfacesfinished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Rendering 10 mm thick in cement mortar 1:3 onfair faces of brickwork or concrete surfacesfinished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instructions complete ( WPC shall be measured and paid separately )all as specified and directed by Engineer-in-Charge. |
| 20 | Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of alkali resistant primer and 1 mm wall care puttyincluding preparation of surface complete all as specified and directed. |
| 21 | Preparation of new plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces with and including 1 mm thick wall care puttycomplete all as specified and directed. |
| 22 | Complete removal of existing treatment,preparation of surfaces of walls and applying two coats of oil bound distemper over and including a coat of alkali resistant primer and 1 mm wall care puttyincluding preparation of surface complete all as specified and directed. |
| 23 | Complete removal of existing treatment,preparation of surfaces of walls,and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces with and including 1 mm thick wall care puttycomplete all as specified and directed. |
| 24 | Preparation of old Plastered of ceiling etc by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss, efflorescence salts treating oil and greasy spots,filling the cracks / holes with cement wall care puttyetc and applying two coats of white wash on walls complete all as specified and directed by Engineer-in-Charge. |
| 25 | Preparation of old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applyingone coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Preparation of old or previously treated wooden surface of any description not otherwise described over 10cm width or girth and applyingone coat of synthetic enamel paintcomplete all as specified and directed by Engineer-in-Charge.Note for item 1 to 2 :- The rates quoted against these items shall be inclusive of use of scaffolding,ladders,cradles,removing nails,making good holes,cracks,removing furniture,washing floors,wall tiles,cleaning glasses,joinery eletric fittings etc of splashes etc |
| 27 | Mild steel framed work suchas inframe work for water tank and similar work conforming to Fe.290.Gde-E-165complete all asas specified and directed by Engineer-in-Charge. |
| 28 | Supplying & fixing of PVC water storage tank 500 ltr capacity HDPE triple layered ,white colourcylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia (Minimum weight200 mm - 210 gms ) including 20 mm/15 mm tank nipple with inlet and outlet pipecomplete Note :(i) Inlet, outlet & wash out pipe will be measured paid for separately.(ii) The quoted rate is inclusive ofminimum one union each on inlet and outlet of water tank as per size of pipe shall be provided. |
| 29 | Supplying and fixingin repairstype stop valves, cast copper alloy, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 20 mm bore, fancy type, chromium plated complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supplying and fixingin repairstype stop valves, cast copper alloy, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 15 mm bore, fancy type, chromium plated complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supplying and fixingin repairs Ball valves high pressure of PTMT with epoxy coated Aluminiumrod& high density plastic ball screwed for iron pipe suitable for GI pipe of 20 mm bore (Minimum weight -210gms) complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supplying and fixingin repairsPVC lids with clips ,screws,locking device complete for 500 / 1000 litre capacity PVC water storage tanks,closed top complete all as specified and directed by Engineer-in-Charge. |
| 33 | Galvanised iron tubes medium grade with all fitting such as sockets,bends,elbows,tees etc concealed / surface fixed to walls and ceilings or laid in floor of dia 15 mm complete all as specified and directed by Engineer-in-Charge. Note :- Cutting chases as required shall be measured and paid separately. |
| 34 | Galvanised iron tubes medium grade with all fitting such as sockets,bends,elbows,tees etc concealed / surface fixed to walls and ceilings or laid in floor of dia 20 mm complete all as specified and directed by Engineer-in-Charge. Note :- Cutting chases as required shall be measured and paid separately. |
| 35 | Fixing only galvanised iron tubes medium grade with all fitting such as sockets,bends,elbows,tees etc concealed / surface fixed to walls and ceilings or laid in floor of dia 15 mm complete all as specified and directed by Engineer-in-Charge. Note :- Cotting/cgasing as required shall be measured and paid separately. |
| 36 | Fixing only galvanised iron tubes medium grade with all fitting such as sockets,bends,elbows,tees etc concealed / surface fixed to walls and ceilings or laid in floor of dia 20 mm complete all as specified and directed by Engineer-in-Charge. Note :- Cotting/cgasing as required shall be measured and paid separately. |
| 37 | 110 mm bore, PVC (SWR) pipes with pressure rating not less than 4 Kg/sqcm single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts or laid in trenches complete all as specified and directed by Engineer-in-Charge. |
| 38 | PVC(SWR)bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. |
| 39 | Note: For the purpose of arriving at Net contract sum amount, the amount of credit schedule i.e Sch \"A\" section II (i.e Rs 26800.00 shall be deducted from the total amount arrived. |
| 40 | Total of Schedule \"A\" Rs. |