| 1 | Surface dressing n.exc 15cm deep and getting out in soft / loose soil cutting bushes / shrubs, grass etc complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soilcomplete all as specified and directed. |
| 4 | Removing surplus excavated soil to a distance exc. 50m and not exc 100 m and depositing where directed at a level n exc. 1.5m above the starting pointcomplete all as specified and directed. |
| 5 | M&L for Cement concrete 1:4:8 type D-2 (using40mm graded crushed stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 6 | M&L RCC Type B1 1:2:4 using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L for RCC type B-1, 1:2:4 using 20mm graded stone aggregatein for Columns,pillars,piers,postsand struts complete all as specified and directed. |
| 8 | M&L TMT bars, 10mm dia and overcut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 9 | All as per ser item No.8 above but 5mm to 10mm dia as in stirrups, spacers binders etc complete all as specified and directed. |
| 10 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 11 | Formwork to square/rectangular sides of pillars,posts, struts, piers,columnsand stanchions, etc for rough finishedsurface of concrete complete all as specified and directed. |
| 12 | M&L for Roof trusses (framed) made of structural steel Fe - 410 - W (Gde E-250),quality A Square or rectangular section trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 13 | M&L for stuctural steel post or Plate girder or single stanchions made of Fe - 410-W (Gde E-250) quality A / built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections complete all as specified and directed. |
| 14 | M&L for Plates (plain or chequered) channels, square cut or notched made of Fe 410- W (Gde E-250) quality A (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 15 | S&F for Mild steel screw bolts (machine made) 16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 22.5cm long but n exc 30 cm long and dia of neck not less than 11 mm to 15mm complete all as specified and directed. |
| 16 | M&L for two coats of synthetic enamel paint on new steel surfaces over one coat of red oxide over 10 cm width or girth not otherwise described,complete all as specified and directed. |
| 17 | S&F forPre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 18 | M&L forPre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 19 | M&L for hard core of gauge n.exc 63 mm broken stone or boulderspread & leveled in layer n.exc 15 cm thick watered & rammed to a true surface complete all as specified and directed. |
| 20 | M& L for 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate in floor, finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 21 | Forming 12 mm thick expansion joints filled with pre formed bituminous filler and top 30 mm primed and sealed with sealing compound grade A complete all as specified and directed. |
| 22 | Forming 10 mm wide and 65 mm deep construction joints filled with pre formed bituminous filler and top 30 mm primed and sealed with sealing compound grade A complete all as specified and directed. |
| 23 | M&L for Brick work with fly ash bricks (old size brick) straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed. |
| 24 | M&L for Rendering 15mm thick cement mortar in CM 1:4 on fair faces of brick work surface rendering to be finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch Complete all as specified and directed. |
| 26 | All as per serial item No. 25.00 but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board. |
| 27 | All as per serial item No. 25.00 but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour Complete all as specified and directed. |
| 28 | Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts Complete all as specified and directed. |
| 29 | Supply and fixing switch piano, flush type, single pole, one way, 15 Amp, 230 Volts Complete all as specified and directed. |
| 30 | Supply and fixing socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts Complete all as specified and directed. |
| 31 | Supply and fixing socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts Complete all as specified and directed. |
| 32 | Supply and fixing ceiling rose surface bakelite 65mmx50mm with two or three terminal Complete all as specified and directed. |
| 33 | Supply and fixing decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 16W to 20W with LED tube of model E-LITE LED pride and connecting up, complete all as specified and directed. Make : Havells cat part No. LHEXBHP71N1W018 or equivalent of philips/Crompton Greaves/ bajaj/Wipro/GE |
| 34 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion esistant including thermal management in multiple optics complete with IP 65/66 protection Complete all as specified and directed. |
| 35 | Supply and fixing sheet metal enclosuresdouble door type suitable for fixing MCB\"s, SPN with 200 Amps rated bus bar,8 way, 240 Volts Complete all as specified and directed. |
| 36 | Supply and fixing sheet metal enclosuresdouble door type suitable for fixing MCB\"s, SPN with 200 Amps rated bus bar,4 way, 240 Volts Complete all as specified and directed. |
| 37 | S & F MCB 63 Amp, three pole & neutral,240 Volt complete all as pecified & directed. |
| 38 | S & F MCB 32/40 Amp, single pole & neutral,240 Volt complete all as pecified & directed. |
| 39 | S & F MCB 6-40 Amp, single pole240 Volt complete all as pecified & directed. |
| 40 | S&F sub main wiring on and includingpassing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductorunsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing U/S sub main wiring Complete all as specified and directed. (Note:Two runs of cable with one run of earth wire and one run of PVC Coundit shouldmeasured as one length) |
| 41 | S&F sub main wiring on and includingpassing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with PVC flexible cable copper conductorunsheathed multistranded single core of size 4 sqmm of green colour confirming to IS 694/1990 including taking down existing U/S sub main wiring Complete all as specified and directed. (Note:Two runs of cable with one run of earth wire and one run of PVC Coundit shouldmeasured as one length) |
| 42 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2.0 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed.Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 43 | M/L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed. |
| 44 | M&L for dry sand and punning for cushioning to under ground cable all as directed.Note :- For the purpose of payment only punned thickness shall be measured. |
| 45 | Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. |
| 46 | M/L for GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including clamps complete of 40 mm bore |