Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of Lime Concrete in ground floorand pavingsexc 15 cm thicknessabove ground floor (Sunken floor) including removal of rubbish out side MOD land complete all as specified and directed. |
| 2 | M&L for PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radius of 75 to 100mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed withintegral water proofing compound as per manufacturer direction )Note :- Integral water proofing compound(WPC) will be measured and paid seperately. |
| 3 | M&L for two coat of acrylic polymer modified cementitiousflexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge complete all as specified and directed.Note : Ponding test :- After water proofingcoating, ponding test willl be done for ponding for 48 Hrs. |
| 4 | M&L for 15mm thick protection plasterin CM (1:4) as infloor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufacturer direction ) complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately. |
| 5 | M&L for 40 mm dia GI pipe, medium grade, as in spout pipe, projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge complete all as specified and as directed. |
| 6 | M&L for PCC (1:5:10) Type E2 (using 40 mm graded stone aggre-gate) as in foundations, sunken portion filling and mass-concretecomplete all as specified and directed. |
| 7 | M&L for 25 mm thick PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate,as in floor mixed withliquid water proofing compound as per manufacturer direction complete all as specified and directed. Note :- Liquid water proofing compound will be measured and paid seperately. |
| 8 | Supply only SBR Latex liquid polymer of approved make complete all as specified and directed. |
| 9 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes (PVC/ SGSW/ AC/ RCC pipe) of the followingbore of pipe, set in cement mortar complete all as specified and as directed. |
| 11 | 100 mm bore pipe |
| 12 | 150 mm SGSW pipe |
| 13 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed :- |
| 14 | 75 mm bore |
| 15 | 110 mm bore |
| 16 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of following size complete all as specified and as directed :- |
| 17 | 110 mm bore |
| 18 | 75mm bore |
| 19 | S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of following size complete all as specified and as directed :- |
| 20 | 110 mm bore |
| 21 | 75 mm bore |
| 22 | S&F PVC (SWR) bends with access door any radius of following size complete all as specified and as directed :- |
| 23 | 110 mm bore |
| 24 | 75 mm bore |
| 25 | S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed. |
| 26 | S&F PVC (SWR) reducers of size 110 mm x75 mmcomplete all as specified and directed. |
| 27 | S&F PVC (SWR) junction single, (single T) with access door equal or unequal of following size complete all as specified and as directed :- |
| 28 | 110 mm bore |
| 29 | 75 mm bore |
| 30 | S&F75 mm bore PVC (SWR) vent cowlcomplete all as specified and as directed |
| 31 | S&F PVC (SWR) multi floor trap, out let dia 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 32 | S&F PVC (SWR) P trap, out let dia 110mm, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 33 | S&F PVC (SWR) floor trap, out let dia 75mm, plain with grating including jointing with solventcomplete all as specified and as directed. |
| 34 | M&L for 150 mm salt glazed stone ware (SGSW) pipe, grade A, ISI marked, laid in trenches and jointed in CM (1:1)complete all as specified and directed. |
| 35 | M&L for 150/100 mm dia pipe cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 36 | S&F stack clamps out of 40 mm by 3 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for following bore of pipe complete all as specified and directed :- |
| 37 | 100mm bore pipe |
| 38 | 75mm bore pipe |
| 39 | Demolition of concrete of any description and in any position not otherwise specifically provided for Cement concrete ( reinforced) reinforcement cut as required to facilitate demolition including removal of debris etc to a distance out side MoD land complete all as specified and directed. |
| 40 | M&L for RCC (1:2:4) type B1 Nominal mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed. |
| 41 | M&L for RCC (1:2:4) type B1 Nominal mix (using 20mm graded stone aggregates)as in Chajjas/ fins/ facia of roof slabincluding form work and one coat of SBR latex as bonding of old concrete to new concrete complete all as specified and directed.Note- 1.The Cost of SBR latex shall deemed to included in the rate.2. The work is required to be carried out at double storyed. The cost of scaffolding, safety and security of workers and approach to roof shall deemed to included in the rate. |
| 42 | M&L for formworkfor rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed. |
| 43 | M&L for precast RCC (1:2:4) type B1, (using 20mm graded stone aggregates) as in cover slab (for manholes) and set in CM (1:6) including necessary fair finish formwork complete all as specified and directed. |
| 44 | M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 45 | Demolition of PCC in ground floorand pavings not exc 15 cm thickness below or above ground levelincluding removal of rubbish out side MOD land complete all as specified and directed. |
| 46 | M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including 4 mm thick glass dividing strip of figured glass pin headed type 73 mm wide inserted in position complete all as specified and directed.Note : Joint to be provided at each interval of 3m and corner and cost of the same deemed included in quoted rate. |
| 47 | Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of following size complete all as specified and directed:- |
| 48 | Area not exc 1.5 sqm each |
| 49 | Area exc 1.5 sqm but not exc 4 sqm each |
| 50 | Taking down and refixing shutters in the same opening of any description including easing and adjusting, of following size complete all as specified and directed:- |
| 51 | Area not exc 1.0 sqm each |
| 52 | Area exc 1.0 sqm but not exc 2.0 sqm each |
| 53 | Taking down shutters of any description, of following size complete all as specified and directed:- |
| 54 | Area exc 1.0 sqm but not exc 2.0 sqm each |
| 55 | M&L for 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and directed. |
| 56 | M&L for 35 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk stainless steel screws complete all as specified and directed.Note: stainless steel butt hinges and necessary stainless steel screws shall be paid separately. |
| 57 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable andvariation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately. |
| 58 | 65mm x 100mm size |
| 59 | 65mm x 125mm size |
| 60 | M&Lfactory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed.Note- S S Butt hing measured and paid separately at relevant item |
| 61 | S&F second class hard wood (sal) plain, fillets, square, rectangular or triangular in section clean sawn, secured with nails of following sectional area complete as specified and as directed:- |
| 62 | Sectional area exc 13 sq cm but not exc 25 sq cm |
| 63 | S&F stainless steel barrel tower bolts of extruded section (ISI Markd)of following size complete all as directed and specified:- |
| 64 | 200 mm long |
| 65 | S&F stainless steel handles fabricated type, of following size complete all as directed and specified:- |
| 66 | 200 mm long |
| 67 | S&F stainless steel sliding door bolt with hasp & Staple, bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of following size complete all as specified and directed:- |
| 68 | 300mm long |
| 69 | S&F stainless steel, non magnetic butt hinge (ISI Marked) and fixed of following size complete all as specified and directed:- |
| 70 | 100 mm long |
| 71 | S&F floor doorstopper (ISI Marked) of aluminium alloy body andtongue anodised, with hard drawn steel spring, fixed in floor of following size complete all as specified and directed :- |
| 72 | 150mm long (overall length of cover plate) |
| 73 | S&F aluminium door seal upto 1200mm long on bottom of door complete all as specified and directed. |
| 74 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or wire staples complete all as specified and as directed. |
| 75 | S&F in repairs for stainless steel non magnetic curtain rod of 20 mm dia with and including fixing brackets and decorative type knobs (as approved by AGE (I)/ GE) both side of each rod complete all as specified and directed.Note: - Measurement will be taken between end point of knobs. |
| 76 | S&F 18 mm thick solid WPC board both side prelamfor cabinet boxes & shutter , cup boards, drawer, etc with shelf and shutter incl lipping to edges of exposed surfaceincluding provn of fixing arrangement complete all as specified and directed. |
| 77 | S&F continuous (piano) hinges, mild steel bright finish or electro galvanised width of flaps (when open) 30mm complete all as specified and directed. |
| 78 | S&F Stainless Steel Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed. |
| 79 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 80 | M&L for brick work with old size full bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 81 | M&L for brick work with old size half bricksubclass ‘B’ burnt clay bricks, straight or curved on plan to any radius, built in CM (1:4) complete all as specified and directed. |
| 82 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. |
| 83 | M&L for 5mm thick rendering in cement plaster (1:3) as in ceiling surfaces and fininshed surface even and smooth without using extra cement complete all as specified and directed. |
| 84 | M&L for 15mm thick plastering on fair faces of brick and concrete solid block wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed.Note :- WPC (Liquid type) shall be measured and paid separately as supply only. |
| 85 | M&L for preparation of new surfaces ofceiling and applying two coats of oil emulsion distemper over a coat of alkali resistant primercomplete all as specified and as directed. |
| 86 | M&L for preparation of old surfaces ofceiling and applying two coats of oil emulsion distemper over a coat of alkali resistant primercomplete all as specified and as directed. |
| 87 | M&L Complete removal of existing treatment by mechanised system on walls internal or external surfaces in any height complete all as specified and directed. |
| 88 | M&L preparation of new orplastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 89 | M&L preparation of old orplastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. |
| 90 | M&L for 15mm thick plastering onfair faces of brick work or concrete surfaces in CM (1:6)finished even and smooth without using extera cement complete all as specified and directed. |
| 91 | M&L preparation of newplastered or unplastered surfaces of wall andapplying two coat ofdistemper oil emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface Complete all as specified and directed. |
| 92 | M&L preparation of old plastered or unplastered surfaces of wall andapplying two coat ofdistemperemulsion white or tinted over and incl of one coat of alkali resistance priming paintand 1mm thick wall care puttyon wall surface Complete all as specified and directed. |
| 93 | M&L for writing letters or figures (Block, Roman, Italic or Indian) not exc 30cm high complete all as specified and as directed. |
| 94 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to storeand rubbish off the premises from MoD land complete all as specified and as directed. |
| 95 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to removedust, etc complete all as specified and directed. |
| 96 | M&L for coloured vitrified tiles of any design and pattern, 600x600x9 to 10mm thick, as in floor and skirting etc Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b with average water absorption between 0.08% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max Deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects.complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) |
| 97 | M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.18 sqm but not exe 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I) |
| 98 | M&L for Non- skidcoloured ceramic tiles of any design and pattern, 300X300X 7 to 8mm thick, in floor etcSet and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects.complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I) |
| 99 | S&F Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishescomplete all as specified and as directed. |
| 100 | M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mmthick, as in dado etc, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects.complete all as specified and directed.Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE (I) |
| 101 | M&L for 10 mm thick plastering on other than fair faces of brick work or concrete surfaces in CM (1:4) to receive glazed tile/ granite complete all as specified and directed. |
| 102 | M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror finish polishingcomplete all as specified and as directedNote:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.) |
| 103 | Description same all as per item No 75above but, as in skirting/ dado (10-12mm thick Kota stone) over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed. |
| 104 | S&F Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishescomplete all as specified and as directed. |
| 105 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed inany mortar and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 106 | M & L18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 107 | Disconnecting and dismantling of water storage tank and removing from the site of following capacity of tank completeall as specified and as directed:- |
| 108 | Capacity exc 500 Ltr but not exc 1000 Ltr |
| 109 | S&F 1000 Ltrs Capacityrotational moulded polyethylene water storage tank, white in colour triple layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, completeall as specified and as directed. |
| 110 | S&F20mm bore ( minimum weight 210gms) ball valve high pressure ofPTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes or brass ferrule and fixed complete all as specified and as directed |
| 111 | Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :- |
| 112 | 15mm bore |
| 113 | 20mm bore |
| 114 | Cutting chases,in brick or concrete surface pinning in. makinggood to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc. and making good, cutting not exc 10 cm girthcomplete all as specified and directed. |
| 115 | S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall,and ceiling or laid in floor of following bore complete all as specified and as directed :- |
| 116 | 15mm bore (Concealed pipe work) |
| 117 | 20mm bore |
| 118 | Refixing old galvanised steel water tubing, with all new fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- |
| 119 | 20 mm bore |
| 120 | S&F20 mm bore gun metal globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and directed |
| 121 | S & F in repair 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure with crutch or butterfly handleor concealed screwed both ends for iron pipe or for unions. complete all as specified and directed. |
| 122 | S&Fchromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed. |
| 123 | S&F in repair 15 mm bore bib taps, chromium plated, fancy type, long body, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed . |
| 124 | S&F in repairs shower rose 125 mm size chromium plated with or without swivel joints, any size, including fixing to15mm GI pipe or union complete all as specified and directed. |
| 125 | S&F in repair Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.complete all as specified and directed. |
| 126 | S&Fglass corner shelf fancy type made of 6 to 7 mm thick sheet glass of size 250mmx250mm fixed with chromium plated brackets complete all as specified and directed. |
| 127 | S&F600 mm longPVC connection 15 mm size with PTMT nutcomplete all as specified and directed. |
| 128 | S&F in repairWash basins (Padestal pattern) 550x400mm vitreous china (flat back type) any 40mm size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting complete all as specified and directed. |
| 129 | S & F for Grating ,cockroch proof, round 125 mm diachromoum plated complete all as specified and directed. |
| 130 | S&F 5mm thick bevelled edge best quality looking mirror of size 600x450 mm with 30mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 6mm thick AC bldg board, complete all as specified and directed. |
| 131 | S&F in repair PVC valveless, syphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approvrd by GE/AGE(I) complete all as specified & directed. |
| 132 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white/ivory, with and including plastic seat and cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., completeall as specified and directed. |
| 133 | S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered \"Hot\" or \"Cold\" ,with long screwed shanks and fly nut capstan head screwed for 15mm dia pipe fixed in repair.completeall as specified and directed. |
| 134 | S&F in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm borepipes complete all as specified and directed. |
| 135 | S&Ftowel rack of size 600 mm fixed with and including CP brass screws and wooden/plastic cleats,complete all as specified and directed. |
| 136 | S&F Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia all as specified and directed. |
| 137 | S&F toilet paper holder chromium plated fixed to wall with chromium plated (CP) brass screws complete all as specified and directed. |
| 138 | S&Flow density polythene pipe (LDPE) of pressurerating 6 Kgf / sqcm fixed to wall or laid in floor etc including fittings of following size complete all as specified and as directed :- |
| 139 | 32 mm bore |
| 140 | S & Fin repairs Sinks with drainage board made of stainless steel 0.8 mm thick kitchen or laboratory with plugs, washers; including bedding in cementmortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460and bowl size 410mm x 330 mm x 160mm complete all as specified and as directed. |
| 141 | S&F Stainless steel kitchen plate rack 24 gauge thick sheet of over all size 31\"x26\"x10\" fixed with steel screws and steel rawl plugs complete all as specified and directed. |
| 142 | S&F PVC Cabinet (box type) size (600X450 )mmX125 mm with looking mirror of selected quality glasshaving 5.5 mm thickand fixed to wallswith screws and wooden/ rawl plugs complete all as specified and directed. |
| 143 | S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight per sqm not exc 4kg complete all as specified and as directed. |
| 144 | S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 145 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 146 | M&L for fixing or passing through pipe, laid in trenches, fixed on wall,LT panel board,XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 4 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools,heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirementall as specified and directed. Note:(i)GI tubing requiredshall be measured and paid separately under relevant item.(iii) Heat shrink sleeve of 25mm long on HS joint for colour indicationshall deemed to be included on the quoted rate. |
| 147 | Excavating in trenches n exc 1.5 m width and n exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 148 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. |
| 149 | Removal of surplus soil to a distance n\"exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 150 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. |
| 151 | Supply and laying cable protection bricks, common burnt clay sub class \"B\" designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. |
| 152 | Supply and laying GI tube light grade 50 mm dia with all fittings laid in trenches or fixed on pole for protection of cable while fix on pole or HT pole structures pipe tightend with D type steel clamp, washers, nut, bolt etc complete all as specified and directed. |
| 153 | M & L for cutting of road /hard standing as required at site, not exceeding 20 cm width and not exceeding 90 cm in depth for laying of cable protection pipe including insert the cable inside pipe making good the disturbed road/hard standing by providing PCC (1:2:4) Type B-1 up to the existing surface level and make good complete all as directed. |
| 154 | Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. |
| 155 | Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed. |
| 156 | Disconnecting and taking down Taking down fan, sealing cable end,dismantling blades and removing fan and blades to storecomplete all as specified and directed. |
| 157 | Disconnectingall electrical connection andtaking down old wooden meter box from existing site,and providingnew meter box of plywood grade BWR, type BB of6 mm thick fixed on wall all as specified and directed. |
| 158 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC),remoteless and complete connection with two core flexible wire to wiring with all accessories and all as specified and directed. (Note: Flexible wire shall be measure and paid seperately) |
| 159 | Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates |
| 160 | All as per item No 125above but for one light point controlled by one no of one way switch single pole, complete all as specified and directed. |
| 161 | All as per item No 125 above but for one ceiling fan point controlled by one no of one way switch single pole,complete all as specified and directed. |
| 162 | All as per item No 125 above but for one Exhaust fan point controlled by one no of one way switch single pole, complete all as specified and directed. |
| 163 | All as per item No125 above but for one call bell point controlled by one no of bell push, complete all as specified and directed. |
| 164 | All as per Item No 125 above but for One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed. |
| 165 | All as per item no 125 but for One 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed. |
| 166 | All as per item no-125 above but controlled by two, two wayswitch5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed. |
| 167 | All as per item No 125 abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed. (Geyser point + power point) |
| 168 | S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzcomplete all as specified and directed. |
| 169 | Supply and fixing switch modular, one-way 16/20 Amps, 1 module 240 Volts AC complete all as specified and directed. |
| 170 | Supply and fixModular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. |
| 171 | Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module230 volts, 50 hz complete all as specified and directed. |
| 172 | Supply and fixing switch modular flush typesingle pole, two way 6 Amp, 1 moduleISI marked, 230 volts, 50 hz all complete all as specified and directed. |
| 173 | Supply and fixing bell push modular flush type single pole one way 6 Amps, 1 module with indicator, ISI marked complete all as specified & directed. |
| 174 | Supply and fixing bell multi music type AC 230/240 volts single pole, complete all as specified & directed. |
| 175 | Supply and fixing in repair batten /angle holder insulated body with back plate, suitable for batten fittings all as specified & directed. |
| 176 | Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals complete all as specified & directed. |
| 177 | Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 440 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >100-120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete allas specified & directed. |
| 178 | Supply and fix surface mounted LED luminiare, 10 watt 2 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete allas specified & directed. |
| 179 | Supply and fixingin repair LED building security light 1X20 W housing made out of pressure die-cast aluminium alloy with toughened glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection up to 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 130 Lumens/watt, power LED should be of more than 01 wattCCT should be between 5700° K- 6500° Kincluding fixed onwall with 02 Nos MS clamp made out of 40X6 mm FI and bracket made out of 32 mm dia light grade GI pipe not less than 0.90 mtr long bend to shape completeallas Specifiedand directedincluding connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from terminalbox to light fittingscomplete all as specified and as directed. |
| 180 | Supply and fixing MCBSPN 10- 32 Amp \"B\" series, 10 KA repturingcapacity all as specified and directed. |
| 181 | Supply and fixing MCCB63 Amp 16 KA 4 Pole in existing TPN DB all as specified and directed. |
| 182 | Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with one, double pole MCB 32 Amps 10 KA rupturingcapacity 240 Volts AC complete all as specified & directed. |
| 183 | S & F fresh air fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air displacement -1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed . |
| 184 | S & F ventilation air fan AC single phase 230/240 Volt of size 250 mm sweep,non-metallic high quality engineering plastic, air delivery 680 cmm Power consumption- 36 W, RPM-1200 complete with louversand two years warranty including making hole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed.Note-: The price for making necessary hole for fixing of exhaust fan is included in quoted rate. |
| 185 | Taking down existing Geyserkeeping in safe custody and refixing the same including replacement of PVC connection and fastners complete all as specified and directed. |
| 186 | Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected withmain earth dolly including cuttingchasesand making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. |
| 187 | Supply and fixing sub main wiring four single core 4 Sqmm PVC insulated unsheathed stranded copper conductor cable (FRLSH) 1100 volts graded drawn in for three phase and one for netural & including rigid PVC conduit 20 mm dia or more medium grade concealed in wall as per existing along with 4. Sqmm PVC insulated unsheathed copper conductor cable (FRLSH) as earth wire connected with main earth dolly including cutting chassing and making good disturbed portion all as specified and directd. Note: Four runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. |
| 188 | M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4.0mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm gradedstone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm stone agrigrtae )reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1including testing and taking out the old one complete all as specified and directedNote - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items. |
| 189 | S& Fwhitemodular cover plate with frame offollowing module complete all as specified and directed. |
| 190 | 2 Module |
| 191 | 3 Module |
| 192 | 6 Module |
| 193 | 8 Module |
| 194 | 12 Module |
| 195 | S & F modular metal flush box ofmodule all as specified and directed. |
| 196 | 2 Module |
| 197 | 3 Module |
| 198 | 6 Module |
| 199 | 8 Module |
| 200 | 12 Module |
| 201 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy