| 1 | Excavating in post holes (or similar holes) in Soft/Disintegrated Rock each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 2 | Removing excavated material (Soft/ disintigrated rock) exc 250m but n.exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 3 | M&L for PCC (1:3:6) Type C2 (using 40 mm graded stone aggre-gate) as in foundations, filling and mass-concrete complete all as specified and directed. |
| 4 | M&L for 25 mm thick PCC (1:2:4) type B1, (using 20 mm graded stone agg) as in sub base of floor complete all as specified and directed. |
| 5 | M&L for cement concrete tiles, machine pressed, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 20 mm thick screed bed in cement mortar (1:6) for following size of tile complete all as specified and as directed:- |
| 6 | 20cm x 20cm x 22 mm thick |
| 7 | S&F rolled mild steel section for structural steel work as in main and cross beams, hip and jack rafters, purlin where connected to common rafters and running rails and guides for sliding crane, fixed with angle cleats or other connecting plates/ bolts, conforming to Fe-290(Gde-E-165)complete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 8 | S&F mild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 with and including one shop coat of zinc chrominium primer paint complete all as specified and as directed.Note : The rates quoted deemed included for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 9 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated conforming to Fe-290 (Gde-E-165) complete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 10 | M&L for 6 mm thick Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment graded Fe-410-W Gde- E-250 quality-A complete all as specified and directed. |
| 11 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 12 | M&L for preparing surfaces of steel, treating end of posts, backs of chowkhats etc area exc 0.1 sqm but not exc 0.50 sqm and treated with tar or coal tar black paint each complete all as specified and directed. |
| 13 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick ofcolour as approved by AGE(I) having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 14 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick ofcolour as approved by AGE(I) having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 15 | S&F Wiring for circuit/submain wiring alongwith earth wire with the 2x1.5 sqmm, 1x1.0 sqmm of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed as required alongwith earth wire (green colour)cable of voltage rating upto and including 1100 Volts drawn in and including rigid PVC conduit 25 mm (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:-NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii)The quoted rates shall be deemedto be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface.The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs. |
| 16 | S&F Double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB double pole of 10 amp complete all as specified and directed. |
| 17 | S&F ceiling rose surface bakelite 65 x 25 mm dia three terminals (ISI Marked) complete all as specified and directed. |
| 18 | S&F surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified and directed. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period. |
| 19 | S&F SPN 32 AMP rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) ofpoles and current carrying capacity in the MCB DBwith connection testing and commissioning complete all as specified and directed. |
| 20 | S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, 10 Sqmm twin core cable flat or circular complete all as specified and directed. |