| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 2 | Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 4 | Taking down plaster on wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed. |
| 5 | Taking down Chowkhats or frames n exceeding 1.5 Sqm each (Without taking off shutters from the frame) complete all as specified and directed. |
| 6 | Taking down Chowkhats or frames exceeding 1.5 Sqm but n exc 4.0 Sqm each (Without taking off shutters from the frame) complete all as specified and directed. |
| 7 | M&L fo Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. |
| 8 | S&F 4.50mm thick linoleum, plain coloured, laid dry in floors including stretching, cutting and fitting and sealed down with an approved adhesive complete all as specified and directed. |
| 9 | M&L for dark shade Vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and n exc 1.00 Sqm, in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM 1:6, and pointed in coloured cement to match complete all as specified and as directed. |
| 10 | M&L 25mmthick Plain Cement Concrete (1:2:4) type B0 using (12.5mm graded stone aggregate) as in floors complete all as specified and as directed. |
| 11 | M&L for non skid coloured ceramic tiles (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and jointed in white/coloured cement to match over and including 15 mm thick screed bed in cement mortar in (1:6), complete all as specified and as directed. |
| 12 | M&L for glazed ceramic colour tiles, size 200x300x7mm/ 350x250x7mm/ 450x350x7mm size as in walls, set and jointed in neat cement slurry over and including 10mm thick backing coat in cement mortar (1:3) and pointed in coloured cement to match for work on vertical surface such as skirting/ dado etc complete all as specified and as directed. |
| 13 | M&L for cement plastering 10mm thick in cement mortar 1:6 on brick work for concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 14 | (a)S&F false ceiling of 12.5 mm thick gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer\"s instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by GE and including supply and fixing of items all as specified as below:-(b)S&F suspended Plain Ceiling includes Perimeter Channel (Material-GI(IS513), YS 260Mpa, Finish-Galvanised 150GSM(IS27) is fixed along with perimeter of existing wall/partition with the help of HILTIHPS-1 (6x40) impact anchor, at 600mm centres.(c)S&F Ceiling Angle (Material-GI(IS513), YS-260Mpa, Finish-Galvanised 150GSM(IS277) is suspended by fixing it to the Gyproc_ soffit cleat (GI (IS513) YS-260Mpa, Finish-Galvanised 150GSM(IS277).Soft Cleat and Gyproc-- Rawl Plug-08x45mm (Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load-6.8kN for M30 concrete grade) creating 1220mm x 1220mm grid.(d)S&F Intermediate channel (Material-GI(IS513), YS-260Mpa, Finish-Galvanised 150GSM(IS277) is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement (Material-As per EN 10083 Finish- Zinc Plating) or with 2 Nos of 04.2x13 Gyproc metal to metal screw (Material-Carbon steel EN-ISO 7049/50 Finish.Zinc Coating Thickness- 4.14micron.)(e)S&F Ceiling Section (Material -GI(IS513),YS-260Mpa, Finish-Galvanised 150GSM (IS277) is then fixed to the Intermediate Channel (Material-GI (IS513), YS-260Mpa, Finish-Galvanised 150 GSM (IS277) with the help of Gyproc Connecting Clip (Material-High carbon spring steel wire (BS 970Gr.En42)-46-48 HRC, Finish-Zinc plating 4-6 micron) and in direction perpendicular to the intermediate channel at 457 mm c/c. (f)S&F Single layer of 12.5mm tapered edge plain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws (Material-Carbon steel EN-ISO 7049/50, Finish-Case hardened Grey Phosphating) at 230mm centres on ceiling section & 150mm at periphery of ceiling.(g) Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc Joint Paper tape. |
| 15 | M&L for pre-cast cement concrete block type C1, 1:3:6 (using 20mm graded stone aggregate) and set in CM 1:6 masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and as directed. |
| 16 | S&F factory made uPVC white colour three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 17 | S&F factory made uPVC door frame made of uPVC extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions. |
| 18 | S&F factory made uPVC white colour two track four panels sliding glazed door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto 10.00 sqm) comprising of uPVC multi-chambered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.l fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed. (Glass or wiremesh shall be paid separately).Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 19 | M&L for Reinforced Cement Concrete type B1,1:2:4 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 20 | M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, wall and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 21 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 22 | S&F 52mm thick PVC partition consisting of 12mm thick plain solid PVC ply sheet reinforced with frame work made from 40mm x 20mm MS tubes. In between two MS tubes, 5mm thick Plain heat moulded C channel of size 75mmx50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply panel shall be inserted in the PVC C channel. The first & last MS tube should be errected such that it is inside a PVC C channel, in between adjoining plastic panel, 5mm thick x75mm width plain PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete all as specified and as directed. |
| 23 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ anneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions complete all as specified and as directed. |
| 24 | S&F 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed. |
| 25 | S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 26 | S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 27 | M&L for applying acrylic thick wall care putty on internal surfaces of walls (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting complete all as specified and directed. |
| 28 | M&L for preparing existing treated surfaces on walls and applying 01 coats of interior emulsion paint (light shade) @ 20 sq.m/litre/1 coats by using roller to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer complete all as specified and directed. |
| 29 | M&L for complete removal of existing surface and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to wall surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended by manufacturer of interior emulsion complete all as specified and directed. |
| 30 | M&L for complete removal of existing surface and applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended by manufacturer of exterior emulsion complete all as specified and directed. |
| 31 | S&F in repair 15mm dia Stop valves, chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 32 | S&F in repair 15mm dia ofGun-metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 33 | S&F in repair chromium plated 15mm dia Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 34 | S&F 15mm dia chromium plated bib taps (fancy type), cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete with checknut complete all as specified and as directed. |
| 35 | S&F Wash basins, Vitreous China (flat back or angle back type) of size 630 x 450mm, including brackets, 32mm dia waste fittings etc complete all as specified and as directed. |
| 36 | S&F Vitreous China Wash down water closet pan (Pedestal pattern), Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devicer, P trap of 110mm dia and fixing bolt etc (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 37 | S&F in repair vitreous China squatting pan \"orrisa\" pattern white colour of size 580x440mm including trap set in and including concrete complete all as specified and as directed. |
| 38 | S&F in repair PVC valveless, syphonic action type, low level PVC flushing cistern 10 ltr capacity white with flush pipe & all fitting complete all as specified and as directed. |
| 39 | S&F in repair 600 x 450mm bevelled edge mirror of selected quality glass 5.0/ 5.5mm thick mounted on standard PVC/Aluminium frame complete all as specified and as directed. |
| 40 | S&F in repair PVC connection 15mm size with PTMT nut of length 600mm etc complete all as specified and as directed. |
| 41 | M&L forpoint wiring in PVC casing & capping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmmPVCinsulated & unsheathed copper conductorcable as earth wire and connected to light/fan & common earth dollywith necessary copper thimbels all as specified and directed for One light/bell / Fan point controlled by one ,one wayswitch complete all as specified and directed. |
| 42 | All as per item No 41 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch complete all as specified and directed. |
| 43 | All as per item No 41 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch complete all as specified and directed. |
| 44 | All as per item No 41 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly complete all as specified and directed. |
| 45 | S&F Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 3 module complete all as specified and directed. |
| 46 | S&F Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 6 module complete all as specified and directed. |
| 47 | S&F Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 8 module complete all as specified and directed. |
| 48 | S&F Modular type single pole one module, 6 Amps complete all as specified and directed. |
| 49 | S&F Switch modular type single pole one module, 16 Amps complete all as specified and directed. |
| 50 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole two module, 6 Amps complete all as specified and directed. |
| 51 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole two module, 6/16 Amps complete all as specified and directed. |
| 52 | S&F Modular bell push single pole one module, 6 Amps complete all as specified and directed. |
| 53 | Modular blank plate one module complete all as specified and directed. |
| 54 | S&F in ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated complete all as specified and directed. |
| 55 | S&F building security light fitting complete with 35 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector complete all as specified and directed. |
| 56 | S&F DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar complete all as specified and directed. |
| 57 | S&F DB, VTPN 4 way vertical type with single/three phase outgoing with provision forMCCB as incomer 415 volt with 200Amps rated bus bar, IEC61439-1 Type testedcomplete all as specified and directed. |
| 58 | S&F MCB 6-32 amps, 10 KA, SP 240 volt, \"C\" series complete all as specified and directed. |
| 59 | S&F MCB 32-40 amps, 10 KA, DP 240 volt, \"C\" series complete all as specified and directed. |
| 60 | All as per item No 59 hereinbefore but MCB DP 63 amps. |
| 61 | All as per item No 59 hereinbefore but MCB TPN 63 amps. |
| 62 | All as per item No 59 hereinbefore but MCB TPN 100 amps. |
| 63 | M&L for sub main wiring in PVC casing and caping of required size 4sqmm PVC insulated multistrand copper conductor FRLS with 01x4 Sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Note:- For the purpose of payment one runs of 4sqmm conductors and one run of 4 sqmm conductor with casing caping will be measured as one length. |
| 64 | M&L forsub main wiring in PVC casing and capping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x6 sqmm PVC insulated multistrand copper conductorFRLS as earth continuity wire all as specified and directed. Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 6sqmm conductor with casing capping will be measured as one length. |
| 65 | S&F LED slim square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed. |
| 66 | S&F invertor LED 4 ft batten 20 Watt, 6500K with square profile and polycarbonate channel , lithium ION battery with charging time 8 Hours -10 Hours and backup time upto 4 hours indoor recess mountingwith reflector andconnector blockandall as specified and directed. Make :Havells Cat Part No. LHEXACP7FN1W20 or its equivalent in PS. |
| 67 | S&F single pole and neutral sheet metal enclosure with a two pin and earth plug socket complete including one single pole MCB of 32 Amp, C Curve, 10 KA rupturing capacity complete all as specified and directed. |
| 68 | S&F three pole and neutral sheet metal enclosure with a two pin and earth plug socket, 4 module complete including one tpn MCB of 40 Amp, C Curve, 10 KA rupturing capacity complete all as specified and directed. |
| 69 | S&F MCCB 4 Pole 100 Amps, 16 KA, 415V, 50 HZ, ICS=100% Icu, with adjustable thermal settings, suitable for isolation complete all as specified and directed. |
| 70 | S&F wall mounted fan single phase, PVC body 400mm sweep, BLDC, voltage 230Volt 50 Hz, 1200 RPM copper winding, winding insulation Class F complete all as specified and directed. |
| 71 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. |
| 72 | Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and as directed. |
| 73 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 74 | M&L for Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 50mm dia suitable for 0.4mpa working pressure all as specified and directed. |
| 75 | M&L for Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary matching including HDPE pipe of 63mm dia suitable for 0.4 MPa working pressure complete all as specified and directed. |
| 76 | Supply, Installation, testing and commissioning of Micro processor based intelligent addressable single loop fire alarm panel with 12V, 7 AH battery complete all as specified and directed. |
| 77 | S&F detectors complying with and type certified to EN-45 addressable type multisensor detectors with heat and smoke combination photoelectric/optical with base with self built intelligence as per IS:11360 complete all specified and directed. |
| 78 | S&F addressable manual call point resettable type complete all specified and directed. |
| 79 | S&F addressable electronic sounder cum strobe complete all specified and directed. |
| 80 | Supply, Installation, testing and commissioning of network card complete all as specified and directed. |
| 81 | Supply, installation, testing and commissioning of control module for siren complete all as specified and directed. |
| 82 | Supply, fixing and installation of addressal repeater panel complete all as specified and directed. |
| 83 | Supply, installation, testing and commissioning of external siren of capacity 2-3 KM range complete all as specified and directed. |
| 84 | Supply and laying of 2 core, 1.5 Sqmm armoured cable complete all specified and directed. |
| 85 | Supply and laying HDPE Pipe 32 mm dia for OFC cables complete all specified and directed. |
| 86 | S&F cable route indicator made out of 3 mm thick MS sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, type of cable with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm complete all as specified and as directed. |
| 87 | S&F Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol complete all as specified and directed. |
| 88 | S&F Special standing seam fixture Clamp for Air terminal on Metal Structure -Site specific complete all as specified and directed. |
| 89 | S&F 3m mast suitable for Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, complete all as specified and directed. |
| 90 | S&F 8 mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 complete all as specified and directed. |
| 91 | S&F Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/ IEC 62305 complete all as specified and directed. |
| 92 | S&F Standing Seam clamp :To hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof, Installation can be made through simple fastening system, mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 complete all as specified and directed. |
| 93 | S&F Cross splicer should be tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol complete all as specified and directed. |
| 94 | S&F Aluminium Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol complete all as specified and directed. |
| 95 | S&F Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 complete all as specified and directed. |
| 96 | S&F test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connect round to Flatconductor complete all as specified and directed. |
| 97 | S&F Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns) Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).;14.2 / OD SS Clamp Both Side; Carbon based backfill compound - 25Kg complete all as specified and directed. |
| 98 | Supply and fix air curtain 4 ftlong, 220-240 V, 50 HZ, RPM (Max/Min) 2700/2100, Body MS Power coated, No. of blowers -03 Nos, No. of motors -02 Nos (single phase), Blower material - ABS, Noise level - 50-70 db, CFM- 825, max air velocity 21 m/s and with motion sensor complete all as specified and directed. |
| 99 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and as directed. |
| 100 | Supply and Lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100V grade with stranded aluminium conductor of size 35 Sqmm 4 core complete all as specified and directed. |
| 101 | M&L for maintenance free earthing complete of comprising of 17.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding, 50 pounds of Ecosafe based environment friendly backfill and suitable clamp, back-fill earthing enhancing compound should strictly be a Eco Safe carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed water and set like concrete and should not leach /diffuse into the ground.Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per IEC :62561-7 for Back-fill compound shall be submitted alongwith the material.17.2 OD SS clamp both side, Eco friendly rust proof heavy duty weather proof Polyethylene Earth pit chamber with following dimensions:254 mm dia (top), 330 mm dia (bottom) & 260 mm (height) complete all as specified and directed. |
| 102 | S&F 8 mm dia solid Aluminium Conductor for roof top mesh grid meets the requirement of IS IEC 62305 (As specified in Drawing) complete all as specified and directed. |
| 103 | S&F conductor holding clamp suitable for mesh grid Conductor holder each at 1 meter distance to meets the requirement of IS IEC 62305 complete all as specified and directed. |
| 104 | S&F cross universal connector for T and cross connection, to route vertical down conductor /mesh formation meet the requirement complete all as specified and directed. |
| 105 | S&F test link in order to disconnect the earth termination system for enabling measurements. to connect Aluminium round conductor to Ring Earthing complete all as specified and directed. |
| 106 | S&F 10 mm copper bonded Round steel solid Conductor in compliance with IS/ IEC 62305 and IEC 62561-2. The coating shall be smooth, continuous & free from flux stains (Ring Earthing) should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding complete all as specified and directed. |
| 107 | S&F SS Straight Connector for connecting Ring Conductor suitable for 10mm Cu. Bonded Steel Conductor to meet the requirement for IS/IEC-62305 complete all as specified and directed. |
| 108 | S&F SS Cross Splicer Providing of cross universal connector For T and cross connection, to route vertical down conductor with stud connection meets the requirements of IS / IEC 62305 complete all as specified and directed. |
| 109 | Supply, installation and commissioning of LT outdoor loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cm height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 125 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 25 KA as incomer and 02 Nos MCCB 4P 63 Amps 16 KA as outgoing complete all as specified and directed. |
| 110 | Supply, install, testing and commissioning of invertor type ductable air conditioning system, of capacity minimum 7.5 TR, comprising of indoor and outdoor unit with invertor compressor of capacity minimum 7.5 TR capacity with R-410A Gas as refrigerant complete all as specified and directed with following items :-(i) CPVC drain piping of size 32mm from indoor units till nearest drain points with necessary bends and fittings as per site requirement.(ii)MS Stand for Outdoor ductable unit duly painted with two coats of red oxide over a coat of black synthetic enamel paint as per site requirement.(iii) Cable of size 4Cx 2.5 Sqmm from outdoor unit to indoor unit as per recommendation of OEM as required at site.(iv) Power cable of size 4C x 10 Sqmm from nearest power source to outdoor unit as per recommendation of OEM as required at site.(v) Open and closed cell nitrile rubber for acoustic insulation of thickness 10mm for insulation of copper tubing from outdoor unit to indoor unit as per site requirements.(vi)GI volume control dumper of suitable size as per recommendation of OEM and as required at site. (vii) Grills with collar damper of suitable size as per recommendation of OEM as as required at site. (viii) Fire retardant flexible canvas connection as per recommendation of OEM and as required at site. (ix) Installation of factory made GI Duct of size 24G/22G with angle flanges / support, joints, gasket, bolts & nuts etc compete all as per recommendation of OEM and approved by accepting officer.(x) Dehumidifier (xi)Temp range 21+ degree celsius(xii) Humidity range 55+5% for lab.(xiii) Dust control - 10 Micron with independent temperature control (xiv) Electric panel as per manufacturers recommendation. (xv) dehumidifier to control Humidity as mentioned at Ser No XII.Note : (i) Contractor has to submit the layout drawings of Ducts as per recommendation of OEM andget approval ofsame before commissioning of plant from Accepting officer.(ii) Cotractor has to carryout nitrogen pressure test after commissioning of plant and has to submit the test report to EIC duly signed by rep of OEM.(iii) Necessary PCC Work required for fixing of stand including making holes in wall deemed to be included in quoted rate nothing extra will be paid to the contractor for this. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail