| 1 | Taking down existing water proofing treatment of any description incl PCC padding, cement plaster any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment incl make good necessary dubbing out wherever required and removing rubbish from site complete all as specified and directed. |
| 2 | Material and Labour for Brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and as directed. |
| 3 | Matrial and Labour for Cement Concrete 1:2:4 Type B-0 (12.50 mm Graded Stone aggregate in padding, finishing surface concrete topping even and fair (without using extra cement) of average thickness 40 mm in slope as required over roof complete all as specified and as directed. |
| 4 | Material and Labour for Providing, cement concrete of Typein roof kerbs on roofor mud stops, rounded or chamfered on edges complete all as specified and as directed By Engineer-in-Charge |
| 5 | Material and Labour for 10 mm thick Plastering in CM 1:4 on concrete roof surfaces using water proofing compound @ 3% by weight of cement and finishing the surface even and fair including taking down and complete removal of existing treatment of any type. WPC will be measured separately. |
| 6 | Supply only liquid waterproofing compound ISI Marked all as specified and as directed. |
| 7 | Material and Labour for Applying evenly two coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces over and Including a coat of Bituminuous Primer at a rate of 1 Kg/Sqm or as per manufacturer\"s instructions complete all as specified and as directed. |
| 8 | Material and Labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 9 | Material and Labour for Preparation of newly laid APP membrane roof treatment over 10 cm width or girth and applying two coats of aluminium paint complete all as specified and as directed. |
| 10 | Supply and Fixing in Repair Rotational moulded polyethylene water storage tanks of capacity 500 Ltrs (Including Dismantling of Existing Tanks (cylindrical vertical with closed top) hoisteand fixed in position all as specified in SSR Part I, including making necessary arrangements for fixing inlet, outlet and overflow pipe and provision of wash out pipe etc and 20 mm ball valves High Pressure PTMT with epoxy coated aluminium rod and high density plastic ball including taking down existing tank complete. |
| 11 | Supply and Fix in Repair Ball valves 20 mm Dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) |
| 12 | Taking up or down steel tubing of bore 20/25 mm and connections, including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge |
| 13 | Refixing any dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed by Engineer-in-Charge |
| 14 | Supplying and laying of CPVC 20mm dia pipes SDR 11 & Plain CPVC SDR 11 incl fittings into walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge |
| 15 | Supplying and laying of CPVC 25mm dia pipes SDR 11 & Plain CPVC SDR 11 incl fittings into walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge |
| 16 | Supply and Fix in Repairs PVC (SWR) pipes of 110 mm Dia,single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls incl all connected/ required fittings complete all as specified and as directed by Engnr-in-Charge |
| 17 | S&F for Bands Straps Supports or stays for Rainwater Ventilating Pipes Including Bolts if required Hooks stay heavy for large complete all as specified and as directed. |
| 18 | Supply and Fix in Repair Gun-metal, globe or gate valves 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Ditto As per item No 18.00 Above but Bore 25 mm. |
| 20 | Demolition of Brickwork or Stone Boulder Masonary, Bulit in Cement Mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed by Engnr-in-Charge. |
| 21 | M & L for brickwork with Fly ash Bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge. |
| 22 | M&L for 10 mm thick rendering in CM 1:6 on fair face of brick/ concrete surfaces finished fair and evenwithout using extra cementcomplete all as specified and directed. |
| 23 | S&F in rpr for3-4 mm thk Sheet glass, tinted ordinary quality for fixing in window or where required complete all as directed |
| 24 | M & L PCC (1:3:6) type C-2 using 40mm graded stone aggregate 75 mm thick as in plinth protection and similar worksfinished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed |
| 25 | Demolition of Concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as spd and directed. |
| 26 | M&L Hardcore of broken stones gauge not exceeding63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface including removal of existing loose soil complete all as specified and directed. |
| 27 | M&L for 100 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as sub base floor complete all as specified. |
| 28 | M & L for sand filling under floors or in fdn including watering and consolidation as in bedding layers for laying tiles. |
| 29 | M&L for factory made Machine pressed precast concrete interlocking paver blocks any shape and size confriming to IS 15658-2006 of 60mm thickness coloured chemically treated PCC (ISI Marked ) M-35 grade of design & pattern approved by GE as in footpath complete all speciified and directed. |