| 1 | Dismantling of sheet roofing (plain, corrugated, semicorrugated, etc.)of any discription, size and pattern complete all as specified and directed |
| 2 | M&L for prepainted colouredgalvaniume aluminium zinc coatingGI basedcorrugated steel sheet 0.50 mm thickof ancolourhaving tensilestregnth of 550 mpaas in roofcovering andcladdingto wall fixed with self tapping screwscomplete all as specified and directed. |
| 3 | M&L for prepainted colouredgalvaniume aluminium zinc coatingGI basedplain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roofcovering /cladding to roof wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | Dismantling timber scantlings 40 sq. cmand over in section (framed work), in any positioncomplete all as specified and directed. |
| 5 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section (framed work), in any positioncomplete all as specified and directed. |
| 6 | M&Lfor timber scantling framed work second class hard-wood clean sawn scantling complete all as specified and directed. |
| 7 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards etc any thickness complete all as specified and directed. |
| 8 | M&L for false ceiling with non asbestor fibercement perforated board 8mm thick of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm exposed metal frame/grid complete all as specified and directed.Note : Frame work for ceiling shall be measured and paid separately |
| 9 | M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two un-equal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/Intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm center to center complete all as specified and directed. |
| 10 | M&L for hangers 6mm dia G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I, flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. |
| 11 | S&F solid PVC wall peneling/lining consisting of 5mm thick Plain colour PVC sheetinclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed.NOTE : (i) Solid PVC Wall Lining shall consist of PVC sheet stuck with solvent cement on PVC sheet panelling fillets as per direction of Engineer-in-Charge, manufacturer’s instruction & drawing. (ii) Rectangular or circular pillars or other insets in the wall shall be covered using heat bent PVC sheet to ensure heat bending of the PVC sheet at the required angle, suitable groove shall be cuts in the PVC sheet if required.(iii) Two PVC lining sheets shall be stuck adjacent to each other after leaving a gap of 2mm. If so desired strips of 5mm thick PVC sheet of width 75mm feathered at the edges can be stuck at the places where two PVC sheets are joined, using solvent cement.(iv) PVC strip shall be measured and paid seperatly under respective item here under. |
| 12 | S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and asdirected by Engineer in Charge. |
| 13 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 14 | M&L for rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6finishing the surface even and smooth without using extra cement complete all as specified and directed.Note:(ii) The unit rates quoted shall be applicable for exicution of work up to 10m height and deemed included cost ofallT&P ,scafolding and all safety precaution (i.e. Safety Jacket, Safety Shoes, Safety Masks, Safety Helmet, Safety harness, Safety Goggles etc) required for smooth exicution of work. Without safety precaution this work will not be allow to commence. |
| 15 | M&L for rendering 10mm thick in CM (1:6) on Brick/conc surface finished even and fair on internal surfaces of wall, complete all as specified and directed. |
| 16 | M&L for rendering 5 mm thick on ceiling surfaces in cement mortar 1:3 finisheing the surface even & fair complete all as specified and directed. |
| 17 | Supply only liquid integral crystalline water proofing compound complete all as specified and directed. |
| 18 | M&L for complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit), make surface clean, free from dust, loose paint etccomplete all as specified and directed. |
| 19 | M&L for two coats of water based premium acrylic smooth exterior emulsion of approved colour with silicon addictive & color stay technology excellent dirt pick up resistance with low VOC less than 50 gram/ltr as per the LEEDS specification anti algal propertiess in two coats @ 1.79 ltrs (undiluted)/10sq mtrs diluted with water as per manufacturer instruction appliedwith fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and capable of operating single spray gun with a max materialhose length of 30 m. the spray machine should be of reputed paint manufacturer as mentioned in PS and accessories for applying emulsion should be able to spray in hard to reach areas and penetration of emulsion on the surface using auto roller for making the surface uniform complete all as specified and directed. Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.Make of Manufacturer : ASIAN/BERGER/NEROLAC or equivalent make as mentioned in appx BNote- The contractor shall obtain approval of the agency from GE and shall enter a memorandum of understanding (MOU) with the manufacturer duly approved by GE.The execution of work shall be commenced after the submission of MOU and necessary approval from the Engineer-in-charge. MOU shall be valid during currency of work. However during defectlibality period, if any defect is noticed, the contractor shall only be responsible for the rectification of same. |
| 20 | M&L for 1mm thick wall care putty with one coat of acrylic water based exterior grade primer @0.9 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed.Make of Manufacturer : ASIAN/ BERGER/ NEROLAC or equivalent make as mentioned in Appx D |
| 21 | M&L forpreparation of old treated surface of wall by scrapping with wire brush/sanding paper/ metal patti, removing nails etc, and make surface clean, free from dust, loose paint etc,filling drpessions, with wall care putty, to receive decorative coat/painting coat complete all as specified and directed |
| 22 | M&L for applying two coats of oil bound distemper on prepared wall surfacecomplete all as specified and directed. |
| 23 | M&L for applying three coats of white wash on prepared ceilingsurfaces, complete all as specified and directed. |
| 24 | M&L for preparation steel/wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over and including a coat of red oxide/pink primercomplete all as specified and directed. |
| 25 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 26 | Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls complete all as specified and directed. |
| 27 | Taking down existing sub main wiring with acessaries and fixtures complete, any discrption, type, capicity and location including disconnection of all electric connection complete all as specified and directed. |
| 28 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only) when found serviceable in all respects complete for reuse or ordered to fixed in repair) complete all as specified and directed. |
| 29 | M&L for point wiring for one light point/ fan point/ exhaust fan point controlled by one switchwith 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed conduit, including non metallic PVC conduit of apropriate size (not less than 20 mm dia) with all accessories, fitting and fixtures, factory made ressessedterminal boxes of reqd size (made of pressed steel sheet not less than 1.6 mm thick) duly painted withtwo coats of block bituminous paint over a coat of red oxide primer (both side),top cover made of 3 mm thick Phenolic laminated sheet, earthing cable of same discription to common earth drawn in same conduit connected to earth dolly and making good disturbed surfaces and finished to match with existing complete all as specified and directed. |
| 30 | All as per item No 29 above but for One 5/15/16 Amp socket outlet on Independant board with 2.5 sqmm (nominal area) cable. |
| 31 | All as per item No 29 above butfor One5 amp socket outlet point on same board. |
| 32 | All as per item No 29 above butfor One bell pointcontrolled by one 5 Amps bell switch. |
| 33 | All as per item No 29 above butfor One 2-way light point controlled by 2x two way 5 Amps switch. |
| 34 | All as per item No. 29 above but for One 15/16 Amp socket outlet on Independant board with 4.0Sqmm (nominal area) cable. |
| 35 | S&F switch piano, flush butten, single pole one way 5 Amps 240 Volt complete all as specified and directed. |
| 36 | S&F switch piano, flush butten, single pole two way 5 Amps 240 Volt complete all as specified and directed. |
| 37 | S&F bell switch, piano type single pole one way 5 Amp complete all as specified and directed |
| 38 | S&F switch piano fiush button single pole one way 15 Amp 240 volt complete all as specified and directed. |
| 39 | S&F socket 5 amps 5 pin, socket outlet, flush type , 230 volts complete all as specified and directed |
| 40 | S&F socket 15 amps 6 pin flush type , 230 volts complete all as specified and directed |
| 41 | S&F switch socket combination 2 in 1, multipurpose,5/6 amps 5/6 pin flush type , 230 volts complete all as specified and directed |
| 42 | S&F switch socket combination 2 in 1, multipurpose,15/16 amps 6 pin flush type , 230 volts complete all as specified and directed |
| 43 | S&Flamp holder insulated body PVC/ Polycabonate type with back plate suitable for batten/ angular/pendent holder fittings including 9 Watt LED lamp/bulb complete all as specified and directed |
| 44 | S&F modular switch 1 way 6 Amp complete all as specified and directed. |
| 45 | S&F modular switch 2 way 6 Amp complete all as specified and directed. |
| 46 | S&F modular switch 1 way 16 Amp complete all as specified and directed. |
| 47 | S&F modular switch bell push 6 Amp complete all as specified and directed. |
| 48 | S&F for modular socket, 6/16Amp combined 2 Module with ISI marked complete all as specified and directed. |
| 49 | S&F for modularsocket6Amp, 2/3 pin type ISI Marked complete all as specified and directed. |
| 50 | S&F LED retrofitlamp of capacity 12 watt, B-22 holder base with polycabonate body and aluminium heat sink warm white complete including taking down old/ unserveciable CFL/bulb complete all as specified and directed. |
| 51 | S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface bakelite sheet 63.50mm dia complete all as specified and directed. |
| 52 | S&F electric bell ding dong type AC 230 Volts, 50 Hz single pole complete all as specified and directed. |
| 53 | S&F fan regulator, modular type, 120 watt single phase complete all as specified and directed. |
| 54 | S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 230 Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 55 | S&F miniature circuit breaker (MCB) SPN 40Amp, 240V, 10KA \"C\" curve, with connections complete all as specified and directed. |
| 56 | S&F miniature circuit breaker (MCB) Single Pole, 6 to 32 Amps 240 volts, 10KA \"C\" Curve complete all as specified and directed. |
| 57 | S&F miniature circuit breaker (MCB) TPN, 63 Amps 415 volts, 10KA, \"C\" Curve complete all as specified and directed. |
| 58 | Taking down light fittings with all fixtures, any discription, type, capicity and in any location including disconnection of electric connections complete all as specified and directed. |
| 59 | S&FLED Mirror light fitting with lamp,1 x 10Watt, 2 feet long, 6000K, Decorative Indirect up-down light for mirror and as wall light application,made of extruded polycarbonate, environmental friendly, energy efficientcomplete with all accessories, prewired and making connection from ceiling rose to connector with and including three core flexible copper cable of size 23/0.0076 of required lengthcomplete all as specified and directed. |
| 60 | S&F LED tube light fittings,18/20 wattfixed on wall with rawl/plug , including making connection from connector to ceiling rose with and including 23/0 0076 flexible copper wire three core of required length complete all as specified and directed. |
| 61 | S&F Decorative wall light fitting/fixture suitable for 15W TU retrofit LED bulb (B-22 base) polycarbonate body, weather proof, environmental friendly, energy efficient with LED lamp and all accessories, prewired including complete making connection from ceiling rose to connector with and including three core flexible copper cable of size 23/0.0076of required lengthcomplete all as specified and directed. Make: Havells Cat No CITY 3,LHDL06160099 or equivalent of Philips / Crompton. |
| 62 | S&Froad lighting luminaire with LED lamp and all accessories, 35 Watt, unique peanut optics to ensure uniform distribution, higher spacing between poles, maintenance free system for city roads and Streets, 50% Energy Savings, IP66 Protection PC and FG Cover, High Impact Resistance fixed on pole/wall with bracket, connecting to existing junction box with and including three core flexible copper wire of size 23/0.0076complete all as specified and directed. |
| 63 | S&F in repair bracket for fixing light fitting on pole, made out of 25mm bore GI pipe (light grade), 1.20 m long made to shape and fixed to existing pole or bldg by means of 2 Nos mild steel flat iron clamps (40x6mm size) with suitable size bolt, nuts & washers complete all as specified and directed. |
| 64 | S&F sub main wiring with two single core FRLS PVC insulated unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area FR PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 20mm dia \"medium grade\" PVC concealed conduits and fittings, complete all as specified and directed.NOTE: One unit length shall measured as two run of main wire and one run of conduit & earth wire |
| 65 | Taking down existing Ceiling fan/Exhaust fans with frame and mosquito mesh net including disconnecting all electrical connection, dismantling blades and depositing to store complete all as specified and directed.(NOTE: Existing fans shall be deposited by the contractor in AGE E/M store Yard at Old Cantt Pryagraj.) |
| 66 | S&F of new exhaust fan, matel body, heavy duty, 300 mm sweep ,single phase 240 volt including making electrical connection from connector to ceiling rose with and including 3 core 23/0.0076 size flaxible copper cable, marking MES No wirh paint complete all as specified and directed. |
| 67 | S&F of new plastic body exhaust fan 250 mm sweep, single phase 240 volt, including making electrical connection from connector to ceiling rose with and including 3 core 23/0.0076 size flaxible copper cable, marking MES No wirh paint complete all as specified and directed |
| 68 | S&F two pin and earth plug and socket with 1 MCB single pole 20 to 32amps \"C\" series 10KA in sheet metal enclosure and connections complete all as specified and directed. |
| 69 | S&F ceiling fan with Brush Less Direct Current (BLDC) Motor,ingle phase AC,230 V, 50 Hz, 1200 mm sweep, BEE 5 star rated, class of insulation: B, copper winding, with remote or electronic regulator unit for speed control, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety ropeand all remaining accessories like safety pin, nut bolts, washers etc, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,complete all as specified and directed. |
| 70 | M&L for Supply,laying, jointing & testing of 16 Sqmm, 4.0 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductorcomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. |
| 71 | S&F PVC sheathed white colour three core copper flexible cable of size 23/.0076 complete all as specified and directed. |