Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-01-2026 | BOQ CORRIGENDUM | BOQ | 27-01-2026 |
| 2 | 13-01-2026 | DATE CORRIGENDUM | Date | 27-01-2026 |
| Sl. No. | Item Description |
| 1 | Taking down Chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames)complete all as specified and as directed. |
| 2 | Taking down Chowkhats or frames exc 1.5 sqm and not 4.00 sq. m each but with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 3 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 4 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heatmoulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail;Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 5 | S&F Pressed steel frames for doors with one or more rebates,1.25mm thk cold rolled mild steel sheet, size of frame 105 x 60mm including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 6 | S&F Pressed steel frames for doors with one or more rebates,1.25mm thk cold rolled mild steel sheet, size of frame 125 x 60mm including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 7 | M&L providing plain cementconcrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in fixing of hold fast, back filling of pressed steel door frame including necessary form work as required complete all as specified and directed. |
| 8 | S&F 35 mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(a), complete all as specified and as directed. |
| 9 | S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 10 | S&F powder coated (minimum thickness of poweder coating 50 micron) anodised aluminium frame for doors, windows, ventileters with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 11 | S&F Powder coatedAnodised aluminium window and ventilator shutters, side hung type without sash bars,with frame, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and directedNote:- (i) Wire cloth /glass shall be measured and paid separately under appropiate items. (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed (iii) Fixing of shutters with fittings shall be as per manufacturers instructions. |
| 12 | S&F 4mm thick plain sheet glass,ordinary quality fixed with Aluminum frame work exc 0.5 sqm in each pane complete all as specified and as directed. |
| 13 | S&F 4mm thick plain sheet glass,ordinary quality frosted one side fixed with Aluminum frame work exc 0.5 sqm in each pane complete all as specified and as directed. |
| 14 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed with Aluminum frame workcomplete all as specified and as directed. |
| 15 | S&F in repair, 18/19mm thick PVC board, 100% Lead free, density not less than 600 Kg/Cbm, prelaminated one side & other side balancing white, as in kitchen cabinet, shelves including 30mm (Width of flaps when opened) Continuous (piano) hinges,mild steel, bright finish or electrogalvanised, magnetic catcher 01 Nos per shutter, 01 Nos. 100mm Stainless steel handle complete all directed. |
| 16 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all asdirected. |
| 17 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 18 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified anddirected. |
| 19 | S&F 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified anddirected. |
| 20 | S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 21 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 22 | S&F in repair, stainless curtain rod of 20mm dia thickness not less than 0.75mm, fixed with curtain rod holder fixed in walls with screws and finials caps complete all as specified and directed.Note: Curtain rod holder and finials caps is deemed to be inclusive in the Unit rate quoted rates) |
| 23 | S&F 300 mmlong Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 24 | S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with inlet ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 25 | S&F in repair Vitreous China wash down water closet pan, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 26 | S&F vitreous China pedestal wash basin, white, flat back, size 550x400mmincluding brackets including cutting forand pinning in ends of brackets or erecting stand, including necessary packing, union and cap , PVC solid 32mm bore waste pipe, 800mm long complete all as specified and as directed. |
| 27 | S&F PVC connection 15mm size with PTMT nuts, 450mm long complete all as specified and as directed. |
| 28 | S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges completeall as specified and directed. |
| 29 | S&F in repair 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 30 | S&F in repair, sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 31 | S&F in repair, 0.63mm thick stainless steel Kitchen rack, overall size 1050mm x 750mm x 250mm complete all as directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/ rubbish from the site complete all as specified and directed. |
| 33 | M&L Glazed ceramic coloured tiles in vertical surfaces 450x 350x 7 mm thick set and jointed in cementitious tile adhesive & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 34 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 35 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 36 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in vetical surfaes, dadoo etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 37 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed. |
| 38 | M&L Granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in flooring including 20 mm thick Screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 39 | M&L Heavy duty coloured ceramic tiles 300mmx300mmx15mm thick in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed. |
| 40 | M&L Heavy duty coloured ceramic tiles 300mmx300mmx15mm thick in in vetical surfaes, dadoo etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 10 mm thick Screed bed or bedding layer of cement mortar 1:4, for laying floor finishes, complete all as specified and directed. |
| 41 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 42 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 43 | M&L 100mm thick Palin cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base of path/hardstanding finished even and fair complete all as specified and directed.. |
| 44 | M&L 100mm thick Palin cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate as in floor laid in alternatebays (not exceeding 2 Sqm each)and finished even and fair without using extra cement complete all as specified and directed. |
| 45 | M&L 25mm thick Palin cement concrete type B-0 (1:2:4) using 12.5 mm graded stone aggregate as in sunken floor mixed with water proofing compound as per manufacturer\"s instructions, finishing the surface even and fair without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid seperately at Supply only rate. |
| 46 | M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 47 | M&L PCC (1:4:8) type D-2 (using 40 mm gradedstone aggregate) as in in foundations, filling and massconcretecomplete all as specified and as directed. |
| 48 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 49 | S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longincluding 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws all as specified complete complete all as specified and directed. |
| 50 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the site complete all as specified and as directed. |
| 51 | Demolition Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 52 | M&L brick work with sub class \"B\" bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 53 | M&L Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 54 | M&L 20mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm& 10mm) mixed with water proofing compound in top layer as per manufacturer\"s instructions, finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid seperately at Supply only rate. |
| 55 | Supply only integral Water proofing compund, complete all as specified and directed. |
| 56 | M&L Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 57 | M&L rendering 5 mm thick on ceiling or concrete Surfaces in cement mortar 1:3 finished even and smooth. (without using extra cement), complete all as specified and directed. |
| 58 | Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all asdirected. |
| 59 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 60 | S&F Rolled mild steel Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.confirming to Fe.410W. Gde-E- 250) quality A) including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 61 | Taking out existing unserviceable water roof treatment of any descriptionfrom RCC roof slab, parapet etc including Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete all as specified anddirected . |
| 62 | M&L PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course to roof surfaces finished even and fair including demoliation of existing unserviceable PCC padding complete all as specified anddirected . |
| 63 | M&L Rendering 10mm thick in cement mortar (1:4) mixed with and including water proofing compound as per manufacture instructionon existing roof surface true to level complete all as specified anddirected . |
| 64 | M&L applying cement slurry @ 3Kg/Sqm over RCC slab complete all as specified anddirected . |
| 65 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, complete all as specified and directed:-(i) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(ii) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm.Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iii) Two coats of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approved by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction |
| 66 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and as directed. |
| 67 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/ Ceilings complete all as specified and as directed. |
| 68 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 69 | S&F 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 70 | S&F 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 71 | S&F PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed. |
| 72 | S&F 110mm bore PVC (SWR) Vent Cowl complete all as specified and as directed. |
| 73 | S&F in repair, 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solventcement complete all as specified and as directed. |
| 74 | S&F in repair 32mm Waste fittings, brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 75 | Taking up or down 15mm bore steel tubing and connections, complete all as directed. |
| 76 | Taking up or down 20mm bore steel tubing and connections, complete all as directed. |
| 77 | Taking up or down 25/32mm bore steel tubing and connections, complete all as directed. |
| 78 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 79 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed. |
| 80 | Supplying and laying of 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed. |
| 81 | S&F in repairs 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type), screwed both endscomplete all as specified and as directed. |
| 82 | S&F in repair 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 83 | S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 84 | S&F in repair, 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 85 | M&Lpreparation of new steel surfaces of any description over 10cm width or girth and applyingtwo coats of synthetic enamel paint complete all as specified and directed. |
| 86 | M&L Preparation of new or previously untreated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling applying two coat of synthetic enamel paint overone coat of pink primer,complete all as specified and directed.. |
| 87 | M&L preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 88 | M&L complete removal of existing finishes,preparation from old wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 89 | M&L applying Two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification including priming coat over 1 mm thick wall care putty,complete all as per manufacturer\"s specification complete all as specified and directed. |
| 90 | M&L for complete removal of existing finishes preparation of old wall surface applying Two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification including priming coat over 1 mm thick wall care putty,complete all as specified and directed. |
| 91 | M&L preperation of new surfaces of ceilings and applying three coat of white wash,complete all as specified and as directed |
| 92 | M&L preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and as directed. |
| 93 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), including dismantling existing unserviceable water tank of any description complete in all as specified and as directed. |
| 94 | S&F in repair, health faucet suitable for 15mm dia pipe, 1.25 meter long easy flexible tubein chrome finish & wall hook all as specified and as directed |
| 95 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 96 | M&L RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate) for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 97 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat, rought finished surfaces of concerete complete all as specified and directed. complete all as specified and directed. |
| 98 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hookingend and binding with and includingmild steel wire not less than 0.90 mm dia (annealed) complete all as specified anddirected . |
| 99 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.Note:- Concealed conduit in RCC slab/beam shall not be not be taken out |
| 100 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 101 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed. |
| 102 | Taking up the existing unservicable UG cable of any type/ description as from any position complete all as directed.Note : Earthwork will be measured and paid seperately. |
| 103 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell pointcontrolled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.(ii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted(iii)Where concealing of conduit is not feasible i.e. on surface ofRCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 104 | All as per item No 103 here-in-above but One socket out let 5/6 amps point on the same board |
| 105 | All as per item No 103 here-in-above but One socket out let 5/6 amps point on the independent board |
| 106 | All as per item No 103 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. |
| 107 | M&L concealed point wiring for One one socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate fittings] concealed in walls, withand including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:- (i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii)Where concealing of conduit is not feasible i.e. on surface ofRCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.(iii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted. |
| 108 | S&F Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 109 | S&F Modular Switch two way 5/6 Amp, 1 module, complete all as specified and directed. |
| 110 | S&F Modular Socket 6 Amps, 5 pin, 2 module, complete all as specified and directed. |
| 111 | S&F Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed. |
| 112 | S&F Modular Socket 6 A/ 16 Amps, 6 pin combined 2, complete all as specified and directed. |
| 113 | S&F ModularBell Push Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 114 | S&F Modular fan regulator, step type, 120 watt, 2 module, complete all as specified and directed.. |
| 115 | S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed |
| 116 | S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 117 | S&F LED bulb 10 watt5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified. |
| 118 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Triple pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 119 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 120 | S&F RCBO for earth leakage, overload and short circuit protection, Four pole, 415 Volts, 30m A, 63 Amps complete all as specified and as directed. |
| 121 | S&F RCBO for earth leakage, overload and short circuit protection, Double pole, 230 Volts, 30m A, 32 Amps complete all as specified and as directed. |
| 122 | S&F MCB, SP, B Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 123 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with Polycarbonate housing & integrated electronic driver,4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed. |
| 124 | S&F energy saving & environment friendly long life 20 Watt,(or nearest next higher wattage)CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete withintegrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 125 | S&F LED luminarie surface/wall mounted chamagne gold finish fixture with plastic body, suitable for 9 Watt LED Lamp,(or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, including LED bulb 9 watt5 STAR LAMPwith B 22 base capacity complete all as specified and as directed. |
| 126 | S&F Bulk head LEDfitting with injection molded Polycarbonate housing suitable for 10 Watt (or nearest next higher wattage)with IP 66 protection & impact resistance not less than IK-10 complete withintegrated type, with high efficiency electronic driver, & high brightness LEDs, luminaire efficacy > 100 lumens/Watt, power factor ≥ 0.95, operating range 140 to 270 V, 50 and connecting complete all as specified and as directed. |
| 127 | Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation, laying of UG cable, pipe etcin soft/loose soil & getting out, complete all as directed. |
| 128 | Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 129 | Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all asdirected. |
| 130 | M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid |
| 131 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed. |
| 132 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 133 | M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked), clamps, nuts bolts etc as required as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed. |
| 134 | Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of pipes, complete all as specified and as directed.Note:- Pipe will be measured and paid seperately under appropiate item |
| 135 | Disconnecting and taking down Ceiling Fan/Exhaust Fan of any Sweep from Electrical Connections, cleaning all dust, etc. thoroughly and re-fixing in Original Position checking smooth functioning and including electrically connected with Flexible Wire multi -stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan cleaning all dust, etc. complete all as specified and as directed. |
| 136 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED. |
| 137 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means ofbolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab(1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. |
| 138 | S&F Cable jointing kit LT 1100 Volts cable End joint kit complete with jointing material and accessories suitable for 25 Sqmm 3.5 coreXLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail