| 1 | Dismantling wall & ceiling boards, any thickness, incl. cover fillets all as specified and as directed. |
| 2 | M&L forPVC Solid Wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed(Colour as directed by Engir-in-Charge). |
| 3 | M&L for 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC framecomplete all as specified and directed. |
| 4 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and as directed. |
| 5 | M&L Non - Skid Ceramicwhite tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, infloors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified & directed |
| 6 | M&L for white glazed ceramic tiles in vertical surface 350 x 250 x 7 mm/ 450X350X7mmthick set and jointed over and including 10 mm thick rendering even and rough in CM1:4 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified. |
| 7 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 15mm thick screed in CM 1:6 etc set complete all as specified and directed. |
| 8 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed and including 10mm thick backing in CM 1:4 etc set complete all as specified and directed. |
| 9 | Supply and fixing 4 mm thick, Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws as in ceiling complete all specified. |
| 10 | Supply and fix GI frame work for seamless ceiling605x605 mm grid comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centreand including6mm dia GI hanger (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed. |
| 11 | Dismantling of GI(corrugated, semi-corrugated) sheet in roof covering complete all as specified and as directed. |
| 12 | S&F pre- painted galvalume aluminum zinc coating GI Based corrugated steelsheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified & directed |
| 13 | S&F pre- painted galvalume aluminum zinc coating GI Basedplan corrugated steelsheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified & directed |
| 14 | Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work. |
| 15 | Material and labour for 2nd class hardwood in scantling clean sawn in any position framed work and fixed.complete all as specified and as directed. |
| 16 | Taking down chowkats or frame with shutters (without taking off shutters from the frames )exc. 1.5 sqm but n.exc. 4 sqm each complete all as specified and as directed. |
| 17 | Material and labour 2nd class Hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixedcomplete all as specified and as directed. |
| 18 | S&F 30mm thick Pre laminated Flush shutters on both sides, solid core construction, with particle board core complete all as specified and as directed. |
| 19 | Material and labour 30 mm thick 2nd class H/W Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed |
| 20 | M&L fortwo coats of synthetic enamel paint over a coat of pink primer of new wooden surface of any description, not other wise described over 10 cm width or girth incl. preparation of surfaces. |
| 21 | Supply and fixwall ties, hold fasts hooks for hanging fans, boarding, wind tie,purlins etc and similar small articles conforming to Fe.290, Gde-E-165 complete all as specified and as directed. |
| 22 | Supply and fixed galvanized mild steel wire cloth 0.56mm fixed nominal dia of wire and avrg widh of aperature 1.18mm and fixed with tinned tacks or galvanised wire staple complete all as specified and as directed. |
| 23 | S&F for150 mm Brass handles, cast type, polished bright all as specified and directed. |
| 24 | S&F 250mm for Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed all as specified and directed. |
| 25 | S&F 150 mm Brass barrel tower bolts, with cast or sheet barrel and rolled orcast bolts and fixed® complete all as specified and directed |
| 26 | S&F 100 mmButt hinges, cast brass,with mild steel hinge pin, bright polished and fixed, typeB-11 all as specified and directed |
| 27 | Demolition of brick work built in cement mortor including all quoins, pillars etc complete all as specified and as directed. |
| 28 | M&L for brick work with sub class ‘B’ (old size bricks) straight or curved on plan exc 6 m mean radius, built in cm 1:6 complete all as specified and directed. |
| 29 | Materials and labour for rendering 15mm thick cement plaster on in two layers each of 10+5mm thick in Cement Mortar (1:4) with liquid water proofing compound of cement on fair faces of brick work completeallas specified and directed.(Note :Integral water proofing compound shall be measured and paid separately under respective item of BoQ) |
| 30 | Supply only liquid water proofing compound confirming to relavent IS |
| 31 | Materials and labour for 10 mm thick rendering in cement mortar (1:6) on brick/concrete surface finished even and smooth without using extra cement, complete all as specified and as directed. |
| 32 | Taking down cement plaster of any description from brick/ stone walls surfaces including. racking out joints, hacking for key, scrubbing down with water etc. and removing debris to a distance n.exc. 50 m, complete all as specified and as directed. |
| 33 | Except timber 2nd class hardwood in scantling clean sawn in any position framed work and fixed.complete all as specified and as directed. |
| 34 | All as per item no 28 here-in-before, but except bricks |
| 35 | Materials and labour for preparing of new surfaces of walls and applying two coat of oil bound distemper(interior grade) on the same after complete prepearation of internel wall surfaces and applying one coat of primer, allcomplete as specified and as directed. |
| 36 | Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces. |
| 37 | M&L for complete removal of existing treatment on walls including brooming down, applying two coats of oil emulsion distemper over and inlucing one coat of primer complete all as specified and directed. |
| 38 | Complete removal of existing treatment including washing, rubbing down and stopping of existing surfaces and applying two coats of exterior emulsion paint of weather coatincluding one coat of emulsion primer and preparation of surfaces on wall surface all as specified and directed . |
| 39 | Taking down carefully/ aluminium point wiring (light, fan, socket or power) complete incl.(fitting such as switches, ceiling rose, pendants, regulators, socket, boards, DB, MCB, light fitting etc), removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc, complete all as per specified and directed. |
| 40 | M&L for Point wiring complete with proper colour coading using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked (white and creamy colour) and including PVC conduit medium grade not less than 25 mm dia, ISI marked with all accessories concealed in wall/celling/floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts Multistranded copper conductor green colour as continuous earth wire and connected to common earth dolly terminated into PVC modular box of required size for one light point / one fan point / one way switch on modular white cover plate with frame of required size (modular white cover plate with frame measured separately) for mounting of switch complete all as specified and directed for the following:- |
| 41 | One light point controlled by one number one way switch. |
| 42 | One ceiling fan point controlled by one number one way switch. |
| 43 | One three pin socket outlet 5 Amps independent board. |
| 44 | One three pin socket outlet 5 Amps same board. |
| 45 | All as per item no 40 here-in-before but4 sqmm complete all as specified and as directed. |
| 46 | Taking down old u/s sub main wiring of any size complete all as specified and directed. |
| 47 | M&L for Sub main wiring with 2 run of single core 2.5 sqmm FRLS (ISI marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC conduit concealed type of min size 25 mm along accessories on roof/ wall/ ceiling etc including one run of 2.5 sqmm FRLS (ISI marked) PVC insulated unsheathed multistanded copper conductor as earth wire complete all as specified and directed. |
| 48 | All as per item no 47 here-in-before but size of the cable 4.0 Sqmm complete all as specified and directed. |
| 49 | All as per item no 47 here-in-before but size of the cable 6.0 Sqmm complete all as specified and directed. |
| 50 | S & Fmodular type switch 6 Amps, one way one module complete all as specified. |
| 51 | S & F Modular Type Socket outlet, 6 Amps,2/3 pin combined 2 module complete all as specified. |
| 52 | S & F Modular Type Socket outlet, 6/16 Amps, combined 2 module complete all as specified. |
| 53 | Material and labour for white cover plate with frame & modular metal flush box suitable for accommodating 1/2 Nos module switch/socket etc complete all as specified and directed by Engr-in-Charge. |
| 54 | All as per item no 53 but 3 module complete all as specified and directed by Engr-in-Charge. |
| 55 | All as per item no 53 but 4 module complete all as specified and directed by Engr-in-Charge. |
| 56 | All as per item no 53 but 6 module complete all as specified and directed by Engr-in-Charge. |
| 57 | All as per item no 53 but 8 module complete all as specified and directed by Engr-in-Charge. |
| 58 | Supply & fixing modular blanking plate suitable for modular switch board complete all as specified and directed. |
| 59 | Supply and fixing of Dboxx MCB protected socket PVC plastic base model (white) including plug with indicator and socket with 20/16 amp MCB (SP) complete all as specified. |
| 60 | Supply and fix ceiling rose, surface bakelite, 65mmX50mm, two to three terminal , PVC/Polycarbonate, insulated body (ISI marked) after teking down unsv one complete all as specified and directed. |
| 61 | Supply and fix modular fan step regulator, 1 to 5 steps, 120 Watt - 2 modulecomplete all as specified and directed by Engr-in-chrage. |
| 62 | Supply and fix LED tube light fitting 1X20 Watts 220 V,AC basic all purpose surface and wall mounteddecorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose ,after taking down unsv one complete all as specified and as directed. |
| 63 | Supply and fix LED luminaire 600X600 mm 36 Watt, 220V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size connecting to the ceiling rose complete all as specified and directed. |
| 64 | Taking down ceiling fan (any make/size), sealing cable end,dismantling blades and removing fan and blades to be handover to E/M sub division-salvage store.) |
| 65 | Supply and fix ceiling fan, complete with three blade, down rod, accessories 230V, 1200mm sweep, ,with squirrel cage induction motor and connection to ceiling rose complete all as specified and as directed. |
| 66 | S&F MCB DB CRCA sheet powder coated vertical type TPN 8 way double door factory made suitable for incorporating MCB as out going MCBs Incoming complete all as specified and directed. |
| 67 | Supply and fix sheet metal enclosure MCB DB 8 way SPN double door suitable for 240 V fixed flused on walls including cutting knitch and making good disturbed surface incl blanking plates as per requirment incl taking down unsv one complete all as specified and directed. |
| 68 | Supply & fix MCB, SPN, AC, 240V IP-43 of 16 to 32 Amps capacity \"C\" series and making connections including taking down unsv one complete all as specified& directed. |
| 69 | Supply & fix MCB, SP, AC, 240V IP-43 of 05 to 32 Amps capacity \"C\" series, 10KA breaking capacity and making connections incl taking down unsv one complete all as specified& directed. |
| 70 | S&F MCCB 4P, AC, 415V IP-43 of 40 Amps capacity and making connection Incl taking down unsv one com all as specified and directed.( Existing panel) |
| 71 | S&F MCB TPN, AC, 415 V IP-43 of 16 to 32 Amps capacity and making connection incl taking down unsv one complete all a specified and directed. |
| 72 | M&L for earthing complete with galvanized stel earth plate electrode 600X600X6 mm, burried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5m below ground level connected to galvanized earth wire 4mm by means of bolt, nut and washer of GI or steel earthing lead to be procted by GI pipe of 40mm bore light grade and other end connected to earthing test point or main controlled switch as directed including providing funnel with 20 mm bore GI pipe medium grade for watering wire mess, charcoal and common salt in alternative layer of 15 cm (completed thickness) all around the earth electrode , concrete earth pit in PCC (1:3:6) type CI, 50 mm thick precast RCC (1:2:4) type B1 cover slab reinforced with 8mm dia TMT bar @ 15 cmboth ways and suitable handle made out of 10mm dia, including necessary excavation and earth work , returning filling and disposal of surplus soil to a distance n. exc 50m and testing on complete connection all as shown in electric plate no 3 SSR part-1 and as directed. |
| 73 | Taking down old unserviceable XLPE cable complete all as specified and directed. |
| 74 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core completelete all as specified and directed. |
| 75 | Excavation in trenches not exc 1.5 wide and not exc 1.5 mtr deep and getting out in soft soil for laying pipes complete all as specified . |
| 76 | Returning and filling in soils , includingspreading ,levelling ,wateringand well ramming in layersnot exc25 cm thick completeall as specified . |
| 77 | Removal of excavated material to a distance not exc 50 mtr away from starting pointand depositing where directed at a level notexc 1.5 mtr above the starting pointcomplete all as specifiedand directed |
| 78 | Supply and spread fine dry river sand 23 cm thick layer for cushioning of cables laid in trenches, leveling, watering, punning to 18 cm from 23 cm by compacting all as directed. (Punned depth shall be measured and paid) |
| 79 | Supplying and laying unreinforced precast concrete cable cover ISI marked, Class LV, type I, flat size 250mm x 150mm x 40mm duly embossed with \"LT CABLE 1100 V\" all as specified and as directed. |
| 80 | Taking down old unserviceable MCCB complete all as specified and directed. |
| 81 | Supply and fixing MCCB 25 amp, 16 KA, 415 V, complete all as specified. |
| 82 | M&L for earthing complete with galvanized steel earth plate electrode 600X600X6 mm, burried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5m below ground level connected to galvanized earth wire 4mm by means of bolt, nut and washer of GI or steel earthing lead to be protected by GI pipe of 40mm bore light grade and other end connected to earthing test point or main controlled switch as directed including providing funnel with 20 mm bore GI pipe medium grade for watering wire mess, charcoal and common salt in alternative layer of 15 cm (completed thickness) all around the earth electrode, concrete earth pit in PCC (1:3:6) type CI, 50 mm thick precast RCC (1:2:4) type B1 cover slab reinforced with 8mm dia TMT bar @ 15 cm both ways and suitable handle made out of 10mm dia, including necessary excavation and earth work, returning filling and disposal of surplus soil to a distance n.exc 50m and testing on complete connection all as shown in electric plate no 3 SSR part-1 and as directed. |