| 1 | Item Rate BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: The Executive Engineer / Chennai Division-II Name of Work: Providing Special repair works to the existing State Fire and Rescue Service Training Centre at Tambaram in Chennai city. Contract No: EE/Ch. DN-II/DB/3498 /2024 Bidder Name : BOOKLET - 4TENDER CODING SHEET ( BOQ) CONTAINS : 8 Pages( RATES TO BE FILLED UP BY THE TENDERER IN THIS CODING SHEET )SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make Qty Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against 1 No Item Quoted Currency in INR / Other Currency Rate exclusive of GST in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Rate exclusive of GST in words AMOUNT Rs. P. AMOUNT Rs. P. TOTAL AMOUNT In Words |
| 2 | Dismantling the damaged pressed tiles in cement mortar |
| 3 | Finishing top of roof with one course of Hydraulic Pressed Tiles of size 23cmx 23cmx20mm thick |
| 4 | Pointing the Pressed Tile over the roof with cement mortar 1:3 (One of cement and three of crushed stone sand) |
| 5 | Finishing the top of flooring with cement concrete 1:3 (One of cement and three of blue granite chips of size 10mm and below) 20 mm thick Ellispattern |
| 6 | Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark conforming to IS 13952:1992- type `A` for Rain water down fall pipe |
| 7 | Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 a. 32mm dia |
| 8 | b. 25mm dia ASTM D schedule 40mm threaded PVC pipe with necessary PVC/GI Specials |
| 9 | Supply and delivery at site and fixing of SFRC manhole cover with frame with locking arrangement a. 60 x 60 cm |
| 10 | Supplying and fixing of C.I man hole cover with locking arrangementsof size 0.6m x 0.6m (50Kg) |
| 11 | Supplying and fixing of 4mm thick pin headed Glass panels with aluminium anodised |
| 12 | Supplying and fixing Mild Steel grills as per the design approved to verandah enclosure or gate |
| 13 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators |
| 14 | Providing and fixing factory made unplasticized polyvinyl chloride (UPVC) Door Frame of size 50X47mm |
| 15 | Dismantling the damaged brick works of cement mortar |
| 16 | Providing Form work and centering for reinforced cement concrete works a. For Column footings, plinth beam, Grade beam, Raft beam, Raft slab etc., |
| 17 | Supplying, fabricating and placing in position of Mild steel Grills / Ribbed Tor Steels (without cement slurry) |
| 18 | Providing and laying in position, Standardised Concrete Mix M-25 Gradea. In Foundation and Basement |
| 19 | Brick work in Cement Mortor 1:6 (One of cement and six of crushed stone sand ) using Chamber burnt bricks of size 9”x4½\"X3” (23x11.4x7.5 cm) for super structure in a. In Ground floor |
| 20 | b Third floor |
| 21 | Plastering with CM 1:5 (one of cement and five of crushed stone sand) 12mm thick |
| 22 | Painting the New walls with two coats of approved best ready mixed plastic emulsion paint |
| 23 | Painting the old iron work with one coat and other similar works with approved first class synthetic enamel ready mixed paint |
| 24 | Supplying and fixing of Single leaf Solid core flush door shutters using boiled water resistance (BWR) teak wood ply a. 1000 x 2100mm |
| 25 | Removing the existing doors and windows |
| 26 | Applying one coat of anticorrosive treatment on steel (20 ltrs. of anit corrosive chemical for one MT of steel reinforcement rods) |
| 27 | Applying one coat of Anticorrosive treatment for steel window/ M.S. Grills (using 5 liters of anti corosive chemical per one MT of steel) |
| 28 | Supply and errection of Rotational Moulded Polyethylenewater storage tanks (HDPE Cylinderical vertical type) capacity of 2000 litres |
| 29 | Removing and refixing the existing grill gate Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |