| 1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 2 | Frame size 50 x 100 mm |
| 3 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 4 | 35 mm thick |
| 5 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 6 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 7 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer- in-Charge. |
| 8 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. |
| 9 | 30 mm thick plain PVC door shutters |
| 10 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 12 | 300x16 mm |
| 13 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 14 | 250x10 mm |
| 15 | 100x10 mm |
| 16 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 17 | 125 mm |
| 18 | 100 mm |
| 19 | Providing and fixing bright finished brass hard drawn hooks and eyes : |
| 20 | 150 mm |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 22 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 23 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 24 | Asbestos Cement sheet |
| 25 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 26 | Ridges plain (500- 600mm) |
| 27 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 28 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 29 | Two or more coats on new work |
| 30 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 31 | One or more coats on old work |
| 32 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 33 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 34 | Of sectional area 40 square centimetres and above |
| 35 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 36 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 37 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 38 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 39 | All kinds of soil. |
| 40 | Earth work in surface excavationnot exceeding 30 cm in depthbut exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge: |
| 41 | All kinds of soil |
| 42 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 43 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 44 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 45 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 46 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 47 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 48 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 49 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 50 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 51 | Foundations,footings,basesof columns,etc.formass concrete |
| 52 | Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. |
| 53 | Suspended floors,roofs,landings,balconies and access platform |
| 54 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 55 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 56 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 57 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 58 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 59 | 12 mm cement plaster of mix: |
| 60 | 1:4(1 cement: 4 fine sand) |
| 61 | 12 mm cement plaster finished with a floating coat of neat cement of mix: |
| 62 | 1:3(1 cement: 3 fine sand) |
| 63 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. |
| 64 | Extra for making chequers of approved pattern on cement concrete floors, steps, landings, pavements etc. |
| 65 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 66 | For thickness of tiles 10 mm to 25 mm |
| 67 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 68 | Providing andlayingCeramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 69 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 70 | Size of Tile 600x600 mm |
| 71 | ProvidingandlayingVitrifiedtilesindiferent sizes (thickness tobe specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 72 | Size of Tile 600x600 mm |
| 73 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : |
| 74 | Orissa pattern W.C. pan of size 580x440 mm |
| 75 | ProvidingandfixingP.V.C.lowlevelflushingcisternwithmanually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 76 | 10 litre capacity - White |
| 77 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 78 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 79 | 15 mm nominal bore |
| 80 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 81 | Flexible pipe42.1.1) 32 mm dia |
| 82 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 83 | 15 mm nominal bore |
| 84 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 85 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 86 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 87 | 150 mm diameter |
| 88 | Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 89 | 110 mm diameter |
| 90 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 91 | Bend 87.5°47.1.1) 110 mm bend |
| 92 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 93 | 20 mm nominal dia Pipes |
| 94 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 95 | 25 mm nominal dia Pipes |
| 96 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 97 | 15 mm nominal bore |
| 98 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 99 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 100 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 101 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 102 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 103 | Old work (one or more coats) |
| 104 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 105 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 106 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 107 | One or more coats on old work |
| 108 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank,IS : 12701marked,withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 109 | Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. |
| 110 | New work (Two or more coats) |
| 111 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 112 | Ingratings,frames,guardbar,ladder,railings,brackets, gates and similar works |
| 113 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 114 | Medium shade pigment using 50% white cement 50% Grey cement |
| 115 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes,(Weight Not less than 10kg per Sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 116 | Superior hardwood Cat-II (A)60.1) 35 mm thick |
| 117 | Providing and fixing pre-painted galvalume(PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 118 | Providing and fixing PVC Half Round (semi circular) Gutter/Pipe use for collection and conveyance of Rain water including all supporting accessories like brackets, elbow, short stop end, stop end outlet of required size with necessary screws, sealents etc. all complete as per the direction of Engineer - in - charge. |
| 119 | 250 mm PVC Half Round |
| 120 | Structural GI work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. As per direction of Engineer - in - charge. |
| 121 | Electric resistance or induction butt welded tubes |
| 122 | Dismantling eaves of facia board. |
| 123 | Dismantling eaves of facia board of 19mm thick ply wood including stacking within 50merers lead. |
| 124 | Providing and fixing eaves and facia board with WPC board of 18mm thick and 30 cm width of approved brand and manufacture with necessary screws etc. all complete as per the direction of Engineer - in - Charge. |
| 125 | Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality. |
| 126 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm. |
| 127 | Providing and fixing C.P. soap Dish Holder having length of 138mm ,breadth 102 mm , height of 75mm with concealedfittings arrangements, weighting not less than 106 grams. |
| 128 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 129 | 15 mm nominal bore with 60 cm length |
| 130 | Providing cement concrete surface drain including earth excavation 10 cm thick bed concrete and 15 cm thick side walling with 1:3:6 (1: Cement 3: Coarse sand 6: Stone aggregate 40mm nominal size) finished with 12 mm thick cement plaster 1:4 (1: Cement 4: fine sand) including floating coat of neat cement inside the drain and its top and exposed surface, including disposal of surplus earth etc. complete, as per standard design. |
| 131 | 23 x 23 cm |
| 132 | Providing and fixing of G.I Pipe gate structure of required dia pipe with complete welding including applying priming coat of approved steel primer. |
| 133 | Providing and fixing decorative type arrow of made of cast iron of size 51/2\" and painted with golden enamel paint complete etc., as per the direction of Engineer -in - Charge. |
| 134 | Supply and fixing rolling shutters of approved make, made of required size G.I laths, interlocked together througgh their entire length and jointed together at the end by end lock, mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull manufactured from high tensile steel wire of adequate strength conforming to IS : 4454-part 1 and G.I top cover of required thickness for rolling shutters. |
| 135 | 80x1.25mm G.I lathswith 1.25 mm thick top cover |
| 136 | Providing and laying United Polyethylene Septic Tanks made of Polyethylene in a single moulding with 3 chambers and 2 manholes, the high wall/thickness of septic tank should with stand load and pressure of the eath to a greate extent, fulfilling the technical sepcification of Type-1B (1000Litrs.) United Polythylene Spetic Tank or equivalent Capacity of flushing per day should be 07-10, diameter of tank 650 mm, length 2500 mm, thickness 10 mm, Number of manhole 2 Nos. and No. of Chambers 3 Nos. of sizes 550 mm dia, diameter of inlet and outlet pipe of 110 mm and Air vent pipe of size 50 mm dia etc. all complete laid as per the direction of Engineer in charge. |
| 137 | Flushing per day should be 07-10 (1000 Ltrs.) |
| 138 | Providing and fixing G.I plain sheet covering over expansion joints with necessary iron screws etc. complete as per direction of Engineer - in - Charge. |
| 139 | G.I Sheet 1.00 mm thick.74.1) 200mm wide |
| 140 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 141 | Of area 3 sq. metres and below |