| 1 | S&F Steel work in tubular trusses/ISMB/Angle section/gusset plates including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 2 | Material and labour for Cement concrete in foundations, filling and mass concrete type D2(1:4:8) using 40 mm graded stone aggregate including compaction of concrete, curing etc. complete. |
| 3 | Supply and fixing 12mm thick toughened glass, selected premium quality and glazing with rubber beads or with glazing clips exc 0.5sqm in each pane including solar control film 25 microne reflective type sticked to glass panes as per instructions of manufacturer all as specified and as directed. |
| 4 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 5 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 6 | S&F PVC (SWR) pipes 110mm bore double socketed in any length with rubber ring joints fixed to walls for rain water pipes all as specified and as directed. |
| 7 | M&L fortwo coat of synthetic enamel paint over 10 cm width or girth,not otherwise described over a coat of redoxide on new surface incl preparation all as specified and as directed. |
| 8 | M&L forExcavation in trenches, not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not of any type of soil all as specified and as directed. |
| 9 | M&L forRCC M-30 in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under reamed piles and mass concrete all as specified and as directed. |
| 10 | M&L forForm work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar works; vertical or to batter for rough finished surfaces all as specified and as directed. |
| 11 | M&L for sand cushioning under foundation tiles including watering and consolidtion complete all as specified and as directed. |
| 12 | M&L for mild steel bars 10mm dia and over FE 410 W(Gde E250) quality A cut to length and bend to shape as required,,including cranking,bending,spirally for hooping and inserting in to footing as bolting in concrete include necessary washer and bolts all as specified and as directed. |
| 13 | M&L for Reinforced cement concrete (Design Mix, M-30) in beams, cantilevers, bressummers, lintels over 1.50 meter span all as specified and as directed. |
| 14 | M&L forReinforced cement concrete (Design Mix, M-30) in Chajja all as specified and as directed. |
| 15 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels cantilevers, shelves including supports, overhungetc. also splays between floors and beams etc. as in rough finished surfaces all as specified and as directed. |
| 16 | M&L forFormwork to chullah hoods, chajjas, troughs and similar items in-cluding edges all as specified and as directed. |
| 17 | M&L forPre-cast cement concrete block Type C1 1:3:6 (20 mm graded aggregate) masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 , complete all as specified and as directed. |
| 18 | S & F 125 x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, all as specified and as directed. |
| 19 | S & F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and as directed. |
| 20 | S & F Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc,making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.](Note: The unit rate quoted by contractor includes cost of glass and wire mesh with in 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each |
| 21 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: (i) Quoted rate shall be include are 4mm thick sheet glass and wire mesh with in 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and connceted accessories.(ii) For uPVC frame, sash and mullion extruded\ profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 22 | S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed all as specified and as directed. |
| 23 | S&F 200 mm long 10 mm dia aluminiumtower bolt all as specified and as directed. |
| 24 | S&F 150 mm long Mild steel pressed handles, oval type, stove enamelled black all as specified and as directed. |
| 25 | S&F 150mm Long, 16mm Dia aluminium aldrop bolt all as specified and as directed. |
| 26 | M&L rendering 10 mm thick in CM 1:6 on PCC block masonry/ brick work or concrete surfaces to be finished even and smooth without using extra cementin internal walls all as specified and as directed. |
| 27 | M&L forrendering 15 mm thick in CM 1:4 on PCC block masonry brick work or concrete surfaces to be finished even andsmooth without using extra cement all as specified and asdirected. |
| 28 | M&L forpreparing newplastered surfaces of wall & apply three coats of white wash over a coat of lime putty complete all as specified and as directed. |
| 29 | M&L for preparing newplastered surfaces of wall & applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified and as directed. |
| 30 | M&L for TMT bars 10 mm dia and over cut to length bent to shape required including cranking,bending,spirally for hooping and binding with and including mild steel wire anealed not less than 0.9 mm dia all as specified and as directed. |
| 31 | All as per item No.30 here in before, but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders all as specified and as directed. |
| 32 | M&L for two coat of synthetic enamel paint over 10 cm width or girth,not otherwise described over a coat of pink primer on new surface incl preparation all as specified and as directed. |
| 33 | M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 75mm thick, watered and rammed to a true surface all as specified and as directed. |
| 34 | M&L forPCC for 50 mm thick (1:3:6) type D-2 using 20 mm graded stone aggregate as in plinth protection all as specified and as directed. |
| 35 | M&L forPCC(1:4:8) type D-2, (using40 mm graded stone aggregate),75 mm thick,as in sub base for floor, finished even and rough complete all as specified and as directed. |
| 36 | M&L forMachine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeover and including 15 mm thick cement screed in (1:4 ) CMcomplete all as specified and as directed. |
| 37 | M&L forMachine cut kota stone slab in skirting 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeover and including 10 mm thick cement screed in (1:4 ) CMcomplete all as specified and as directed. |
| 38 | M&Lfor Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. |
| 39 | M&L for Providing and fixing 10mm thick plaster of paris ceiling (Gypsum unhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wirmesh (Note:Fillets, metal frame work and G.I. wire mesh etc shall be measured and paid separately) |
| 40 | M&L for Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil all as specified and as directed. |
| 41 | M&L for removal of excavated soil n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point all as specified and as directed. |