| 1 | B/R Portion: -Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and as directed. |
| 2 | Excavating in trenches not exceeding 1.50m wide and not exceeding 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 3 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in each layers hard/ dense soil complete all as specified and as directed. |
| 4 | Removing excavated materials in soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed. |
| 5 | Hardcore of gauge of broken boulders exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cmthick, watered and rolled/ rammed to a true surface complete all as specified and as directed. |
| 6 | Brick work with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 7 | PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in mass concrete in foundation) complete all as specified and as directed. |
| 8 | Providing precast cement concrete of mix (1:3:6) (using 12.5 mm graded crushed stone aggregate) louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar (1:6) complete all as specified and as directed. |
| 9 | PCC (1:4:8) type D-2 75mm thick (using 40 mm graded crushed stone aggregate) as sub base to floor complete all as specified and as directed. |
| 10 | 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of (1:3) by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and as directed. |
| 11 | RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in foundations/ plinth beams complete all as specified and as directed. |
| 12 | RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in columns complete all as specified and as directed. |
| 13 | RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in Chajjas complete all as specified and as directed. |
| 14 | RCC (1:2:4) mix, type B-1 (using 20mm graded crushed stone aggregate) as in lintel beams, roof beams supported on walls as for roof slabs, lintel etc. complete all as specified and as directed. |
| 15 | RCC (1:2:4) mix, type B-1 (using 20mm graded crushed stone aggregate) as in slabs and shelves etc. complete all as specified and as directed. |
| 16 | RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping, bond stone etc. complete all as specified and as directed. |
| 17 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter complete all as specified and as directed. |
| 18 | Formwork to sides and soffits of roof beams, tie beams, etc. also splays between floors and beams, etc complete all as specified and as directed. |
| 19 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions square/ rectangular complete all as specified and as directed. |
| 20 | Formwork to soffits of slabs including supports, overhangings etc, for fair finished surfaces of concrete complete all as specified and as directed. |
| 21 | Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 22 | Formwork to edges of roof slab of thick not exceeding 20cm wide and as in similar work complete all as specified and as directed. |
| 23 | Formwork flat and rough for coping beams complete all as specified and as directed. |
| 24 | TMT bars (Fe 500), 10 mm dia and over in reinforcement cut to length, bent to shape required including bending spirally cranking, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 25 | TMT bars (Fe 500), 5mm dia and over upto including 10mm dia stirrups bending spirally or hooping for columns, hooking ends and binding with mild sleel wire not less than 0.90mm dia complete all as specified and as directed. |
| 26 | 15 mm thick rendering in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 27 | Rendering 15mm thick on fair faces of brick/ concrete surfaces built in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and as directed. |
| 28 | 5 mm thick rendering in cement mortar (1:3) on fair faces of brick work or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified and as directed. |
| 29 | Rendering 15mm thick cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 30 | Applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over new surfaces complete all as specified and as directed. |
| 31 | Preparation of new surface and applying two coats of oil bound distemper new plaster surface over 1 mm thick putty complete all as specified and as directed. |
| 32 | Preparation of new surface and applying two coats of exterior emulsion/ weather proof paint over a coat of primer over and including 1mm thick putty on plastered surface complete all as specified and as directed. |
| 33 | Preparation ofsurfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 34 | Provision of roof treatment with polymeric water proofing membrane all as given below: -(a) Material and labour for plastering 10 mm thick in cement mortar (1:3) using 100% coarse sand on roof surface including water proofing compound as per manufacturer\"s instructions and as directed by Engineer-in-Charge.(b) Applying a coat of bituminous primer conforming to IS : 3384-1986 @ 0.25 Iitres/ Sqm on prepared surface and allowed to dry.(c) Applying and laying 3mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10 cm and 15 cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar (1:3).(d) Material and labour for two coats of aluminium paint on membrane surface 1338.40 complete all as specified and directed. |
| 35 | Vitrified tiles any colour 10 mm thick (square/ rectangular) polished as in floor, area of each tilenot exceeding 0.36 Sqm etc set and jointed over neat 5-6 mm thick approved polymer modified tile adhesive of appropriate grade as per manufacturer\"s instruction and laid with 3-4mm spacer, spacer gaps to be filled with approved epoxy grout and including screed bed or bedding layer of mortar 15 mm thick cement mortar (1:6) for laying floor finishes complete all as specified and as directed. |
| 36 | Description all as per Ser item No 35.00 here-in-before but in vertical surfaces fixed with 3-4 mm spacer set and jointed over neat 5-6 mm thick approved tile adhesive polymer modified tile adhesive of appropriate grade as per manufacturer\"s instruction and provided with 3-4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed. |
| 37 | Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grith complete all as specified and as directed. |
| 38 | Supply only water proofing compound complete all as specified and as directed. |
| 39 | Powder coated aluminium three track sliding type glazed window, shutter with 5mm thick plain sheet glass fixed open track section 100 x 38 x 1.4 mm having three track (two of 5.50 mm thick glass and one of stainless steel wire cloth of 0.56 mm dia and 1.18 mm aperture) with members of window shutters of section 38 x 12mm including aluminium grill 75 mm x 5.50 mm thick pitch diamond shape, wire gauge and grill shall be fixed with the help of 40 mm aluminium flat and other standard Bombay sliding section including all necessary fiber wheel rollers suitable handle to facilitate sliding and all necessary jointing cleats glazing clips, rubber packing, Aluminium snap beeding etc complete all as specified and as directed. |
| 40 | Aluminium powder coated aluminium door shutters with frame (frame sections not less than 3mm thick), shutter sections not less than 2mm thick. Bottom half panel filled with 8 mm thick prelaminated particle board and top half portion covered with 5.5mm thick frosted glass including necessary joining cleats, glazing clips, rubber neoparene packing, handles 2 nos in each door, hinges, anodised aluminium snap beading, screws, two way floor door spring, mortise lock with keys etc. complete all as specified and as directed. |
| 41 | Curtain rod of stainless steel 20mm dia and side capes fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and as directed by Engineer-in-Charge. |
| 42 | Spreading and levelling in layers not exceeding 25 cm thick and add for well ramming including watering as required complete all as specified and as directed. |
| 43 | E/M Portion: -Point wiring for one light/ fan/ call bell point controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including medium grade PVC conduit 25mm dia concealed with cutting chases and making good disturbed surface complete including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn same conduit with modular cast iron/ pressed steel sunken terminal boxes of required size with modular cover plate with frame for mounting switches, sockets, fan regulators etc complete all as specified and as directed.Note: - (i) Wiring shall be done in proper colour coding.(ii) Rates are inclusive of cutting chases with suitable PCC works and making good to disturbed surfaces. |
| 44 | Description all as per Ser item No 43.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board without inverter wire complete all as specified and as directed. |
| 45 | Description all as per Ser item No 43.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board with inverter wire complete all as specified and as directed. |
| 46 | Description all as per Ser item No 43.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green color complete all as specified and as directed by Engineer-in-Charge. |
| 47 | Modular Socket, 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed. |
| 48 | Modular switch 1 way 6A, 1 module, 240 volts ISI marked complete all as specified and as directed. |
| 49 | Ceiling rose, 3 Phase/ PVC/ polycarbonate isolated body complete all as specified and as directed. |
| 50 | Modular switch 1 way 16A, 1 module, 240 volts ISI marked complete all as specified and as directed. |
| 51 | Modular Socket 6A/16A - 6 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed. |
| 52 | Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 53 | Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed. |
| 54 | LED light fitting 1 x 20W, 220V, AC decorative type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4\" ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed. |
| 55 | LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 56 | Ceiling fans complete with blades, hanging hooks and accessories, Fan regulators, 230 V, 1200 mm sweep minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) including checking of electric supply to the fan point and hanging of new fans on new hooks, etc. complete all as specified and as directed. |
| 57 | Modular fan step regulator, 120W - 2 module complete all as specified and as directed. |
| 58 | Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed.Note: - Wiring shall be done in proper colour coding. |
| 59 | Distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make. |
| 60 | SPN 40 to 63 Amp rating 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 61 | 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 Amp complete with connection, testing and commissioning complete all as specified and as directed. |
| 62 | Supply and install hi wall split units indoor/ outdoor 5 star rating complete with cordless remote control unit andf with in built Heating and Cooling arrangement and Digital inverter twin rotary of capacity 1.5 Ton complete all as specified and as directed by Engineer-in-Charge. |
| 63 | Double pole and neutral enclosure witha two pin and earth plug and socket complete with 25 Amp MCB for Split type Air conditioner complete all as specified and as directed. |
| 64 | Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 5 KVA complete all as specified and as directed. |
| 65 | Supply and laying and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 16 Sqmm, 2 core in and including taking out old one complete all as specified and as directed. |
| 66 | GI tubing light graded 32mm dia including all accessories for encasing cables for mechanical protection, laid under plinth/ floors/ path culverts with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |
| 67 | Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed. |
| 68 | Supply and laying in trenches, fixing or passing through pipe, fixed to wall/ pole, connecting and testing for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.Note: - Wherever cable fixing/ connection, suitable thimble should be used as per site situation. |
| 69 | Flood security light fitting 35/45 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed. |
| 70 | Security light bracket, made out of suitable size GI/MS pipe (medium grade) of suitable length, bend to shape as required and welded and fixing in position with mild steel clamps nuts and bolts complete all as specified and as directed. |
| 71 | Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed. |
| 72 | Sub class \"B\" old size well burnt bricks, laid flat with width equal to length of brick in trenches as protection to cable complete all as specified and as directed. |
| 73 | Cutting the existing concrete/ bituminous road surface width not exceeding 30 cm and making good the surface with 100mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) finished even and fair complete over 100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) over consolidated/ rammed earth surface complete all as specified and as directed. |
| 74 | Bus bar chamber with MCB 63 Amps TPN including aluminium bus bar with 4 O/G ways and all accessories with mild steel angle and frames and PCC foundation work complete all as specified and as directed. |
| 75 | GI pipe medium grade with fittings laid in trenches of 40mm bore of pipe complete all as specified and as directed. |
| 76 | Description all as per Ser item No 75.00 here-in-before but of size 25mm dia bore complete all a specified and as directed. |
| 77 | Description all as per Ser item No 75.00 here-in-before but of size 20mm dia bore complete all a specified and as directed. |
| 78 | Gate valve both side screwed fixing with 40mm bore GI pipe complete all as specified and as directed. |
| 79 | Description all as per Ser item No 78.00 here-in-before but of size 25mm dia bore complete all as specified and as directed. |
| 80 | Description all as per Ser item No 78.00 here-in-before but of size 20mm dia bore complete all as specified and as directed. |
| 81 | Cutting of existing GI/ CI/ DI pipe dia 100mm to 150mm in position for insertion of new GI tee for branch connection complete with all fittings complete all as specified and as directed. |