| Sl. No. | Item Description |
| 1 | Supply & install in replacement smoke and heat detectors, photoelectric / optical type certified to EN 54 addressable with self built intelligent with connected accessories complying with optical chamber, cover, case molding, photodiode (transducer), infrared LED all as specified and directed. NOTE:- (i) Junction box of suitable size for detector the concrete mother ceiling / surface along with necessary gland.(ii) Rate of metal/PVCboxes shall be including in quoted rate of items. Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 2 | Supply & install in replacementFire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measuredat 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range.Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 3 | Supply & install in replacementAddressable electronic sounder cum strobe.Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 4 | Supply & install2 core solid copper conductor of size 1.5 sqmm, as per IS-1554 PVC insulated & PVC sheathed, armoured cable FRLS down through non metallic PVC conduit of suitable size shall be properly clamped to the ceiling / surfacesincluding taking down of unserviceable cable and \"S\" loop shall also be left where cables connect to sounders, panels and all the cables and wires shall be tagged for proper identification complete all as specified and directed. |
| 5 | Supply & install in replacementNetwork card suitable for PLC fire control panel 2/4 Loop complete all as specified and as directed. Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 6 | Supply & install in replacement Addressable control module.Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 7 | Supply & install in replacementAddressable manual call point resettable type.Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 8 | Supply and FixSealed Maintenance Free (SMF) battery of capacity 12 V, upto 7 AH, suitable for fire panel including initial charging completeetc including taking down of old battery complete all as specified and directed. Make of battery : Exide / Amar raja / Amaron Note :-(i)The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation.(ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract. |
| 9 | Supply and installation, programming and testing in relacement of fire PLC control panel complying with BS EN 54 1 loop panel with 242 detector & 99 module DXc1 Single loop Fire Alarm Control Panel two loop card inbuild minimum 200 addressable points detectors/ devices per Loop6*40 character blue crystal display with backlightcircuits PT requiresincluding taking down of old one complete all as specified and as directed.Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 10 | Supply & install in replacement conventional smoke detectorsdetectors in the concreteceiling / surface along with necessary complete allas directed . Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 11 | Supply & install in replacementconventional electronic sounder cum strobe.Make :- Honeywell/ Ceasefire /GST/Universal (Ravel) |
| 12 | Supply & install in replacementrepeater panel active type . Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 13 | Supply & install in replacementNetwork card suitable for repeater fire panel complete all as specified and as directed. Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 14 | Supply and fixing in repair of power back up unit 1100 VA minimum 30 min backup with wall mounted SS stand complete all as specified and directed.Make : APC / Microtech / Zebronics |
| 15 | Supply & install in replacement conventional heat detectors in the concreteceiling / surface along with necessary complete all as directed . Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 16 | Supply & install in replacementconventional manual call point resettable type.Make :- Honeywell/Ceasefire /GST/Universal (Ravel) |
| 17 | M&L for removing the smoke / heat detector and cleaning with the help of specialblower as per OEM recommendation up to height 7 mtr complete all as specified and directed. |
| 18 | Supply, installation and testing in repairof fireconventional control panel 2 Zone panel with max 20 detectorper Zone Fire Alarm Control Panel 16X2character blue crystal display including taking down of old one and complete all as specified and directed.Make : Honeywell/Ceasefire/Visionic/Universal(Ravel) |
| 19 | M& L inrepair PVC conduit medium grade of size 20 mm on wall /roofwith help of screws and GI shaddle including fixing of existingserviceable copper /aluminium conductorand all fitting fixture such as Tee, Elbow and lappingcompleteall as specified and as directed. |
| 20 | M& L inrepairPVC conduit medium grade of size 25mm on wall /roofwith help of screws and GI shaddle including fixing of existingserviceable copper /aluminium conductorand all fitting fixture such as Tee, Elbow and lappingcompleteall as specified and as directed. |
| 21 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 22 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed. |
| 23 | S & F in repairs 3.0 mm thick hylum sheetforfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size6\"x 8\" all as specified and directed. |
| 24 | S & F in repairs 3.0 mm thick hylum sheetforfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 8\"x 8\" all as specified and directed. |
| 25 | S & F in repairs Modular flush metal box 1/2 module in the existing wall complete all as directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 26 | Supply and Fix in repair switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 27 | Supply and Fix in repair shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 28 | Supply and Fix in repair shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 29 | Supply and Fix in repair shuttered switch socket outlet 2 in 1, 3/5 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 30 | Taking down the existing UNSV electric water heater storage type carefully from the position and deposit to store yard / refixing purpose complete all as specified and directed. |
| 31 | Re-fixing of electric storage water heater of 15/25 ltr capacity in new location with nut, bolt and washers and making water supply functional complete all as specified and directed. |
| 32 | S & F in repairs CPStop cock, cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm diaall as specified and directed. |
| 33 | M & L for Cutting existing steel tubing in position without taking down for alterations or additions (Each cut measured) of size 15-20 mm dia GI pipeall as specified and directed. |
| 34 | M & L for Screwing existing steel tubing in position without taking down for alterations or additions (or lengthening screw on pipe to form connector) of size 15-20 mm dia GI pipeall as specified and directed. |
| 35 | S & F in repairs CP tap, fancy type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm diaall as specified and directed. |
| 36 | M&L for cutting of hole through cement concrete wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of pipe of Geyser of size 32 to 40mm all as specified and as directed. |
| 37 | Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed. |
| 38 | M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of pipe of Geyser of size 32 to 40mm all as specified and as directed. |
| 39 | Taking down carefully copper/aluminum pointwiring(light, fan,Power) completefittings such as switches , ceiling roses pendents , regulatorssocketslight fittingsetc and making good disturbed surface of wall, floors , roofetc all as specified. |
| 40 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including metal flush boxes, concealed/surface in wall/roofs/floor/ ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dollyfor one light point point controlled by one wayswitch complete all as specified and directed. Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 41 | All as per item No 40 but for One ceiling fan point controlled byone way 5/6 Amp witch. |
| 42 | All as per item No 40 but for One Exhaust fan point controlled by one way 5/6 Amp witch. |
| 43 | All as per item No. 40 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 44 | All as per item No. 40 here in before but for one 3 pin socket outlet 5 Ampon the same board |
| 45 | All as per Sl No. 40 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 46 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 47 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 48 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 49 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 50 | S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor |
| 51 | S & F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directedMake : Anchor/Havells/L&T |
| 52 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 53 | S&F in replacementfactory madepowder coated distribution board VTPN, 8 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 54 | S&F in replacement distribution board MCCB four pole, 160Amp ultimate breaking capacity 25 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 55 | S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 56 | S & F MCB in repair SPN 240 volts 40 to 63 Amps\"C\" series 10 KA breakingcapacity complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 57 | Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 58 | Supply and fixing round/square shape 12 watt 220 volts ACrecessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copperconductor cable of suitable size complete. Make: Philips/Bajaj/CG |
| 59 | Taking down of old unserviceable ceiling fan of any size and keeping in safe custody for re-use complete all as specified and directed. |
| 60 | Refixingexisting serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed by Engineer-in-Charge. Note : cost includes replacement of rubber bush ,hanging hook with new cotter pins etc complete. |
| 61 | Supply and fixing ceiling fan 1200mm sweep, energy efficientISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-Old Unserviceable domestic ceiling fan shall be deposited to MES store yard. |
| 62 | S & F in repairs 3.0 mm thick hylum sheetforfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 8\"x 12\" all as specified and directed. |
| 63 | S & F in repairs Modular flush metal box 3 module in the existing wall complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 64 | S & F in repairs Modular flush metal box 4 module in the existing wallcomplete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 65 | S & F in repairs Modular flush metal box 6 module in the existing wallcomplete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 66 | S & F in repairs Modular blank plate one modulecomplete all as specified and directed. |
| 67 | S & F in repairs modular stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified |
| 68 | S & F in replacement of Modular Switch 1 way 6 A, 1 Module |
| 69 | S & F in replacement of Modular Switch 1 way 16 A, 1 Module |
| 70 | S & F in replacement of Modular socket 6 A, - 2/3 pin combined 2 module |
| 71 | S & F in replacement of Modular socket 6/16 A, - 3 / 5 pin comb 2 module |
| 72 | S & F in replacement of modular White cover plate with frame, 2 module |
| 73 | S & F in replacement of modular White cover plate with frame, 3 module |
| 74 | S & F in replacement of modular White cover plate with frame, 4 module |
| 75 | S & F in replacement of modular White cover plate with frame, 6 module |
| 76 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 SqmmPVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 77 | S&F in replacementfactory madepowder coated distribution board VTPN, 6 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as specified and directed.Make : Indoasian/Havells/ Legrand. |
| 78 | S&F in replacement distribution board MCCB four pole, 125 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 79 | S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 80 | S & F MCB in repair SPN 240 volts 32 Amps \"C\" series 10 KA breakingcapacitycomplete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 81 | Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 82 | M&L for refixingexisting serviceable LED light fittingafter cleaning all dust etc. completeall as specified and as directed . |
| 83 | S&F in repairs 35/36 W( WH) LED recessed/surface type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. |
| 84 | Taking down of old unserviceable exhaust fan/Wall mounted fan of any size and keeping in safe custody for re-use complete all as specified and directed. |
| 85 | Refixingexisting serviceable wall mounted fans/Exhaust Fan 300/225 mm sweep servicing, paintingExhaust fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed by Engineer-in-Charge. |
| 86 | M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250 to 450 mm all as specified and as directed. |
| 87 | Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, PVC body,1400 RPM,with necessary nut, bolts / screws with louver, writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 88 | M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsibility of the contractor |
| 89 | Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . |
| 90 | S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG |
| 91 | S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 92 | S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 93 | S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 94 | S & F in repair MCB single pole 240 volts 40-63 Amps \"C\" series 10 KA breakingcapacitycomplete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 95 | S&F in replacementfactory madepowder coated distribution board TPN, 8 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 96 | Supply and fixingMCB TPN 415 Volts, \"C\" series, breaking capacity 10 KA of rating 40-63 Amps Make : Legrand /Schiender/Indo Asian |
| 97 | M&L for cutting of hole through cement concrete wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250 to 450 mm all as specified and as directed. |
| 98 | Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, metal body,1400 RPM,with necessary nut, bolts / screws with louver, writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 99 | M&L forin repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsible of the contractor. |
| 100 | Material & Labour for Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed. |
| 101 | Material and labour for Dismantling of ACSR or AAC conductors of any type and description all as specified and directed. |
| 102 | Material and labour for Dismantling stay assembly complete all as specified and directed. |
| 103 | Dismantling & taking down shackle/pin insulators of any size and type complete all as specified and as directed by Engineer-in-Charge. |
| 104 | Material & Labour for Dismantling old u/s service cable of any type complete all as directed . |
| 105 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in soft/loose for foundation of pole, laying under ground cables etc and getting out complete all as directed. |
| 106 | Returning filling in with the earth obtained from above item including spreading, levelling, watering and well ramming in layers and not exceeding 25 cm in layer complete all as specified and directed. |
| 107 | Removing surplus soil to a distance not exceeding 50 Mtr and deposting where directed at a level not exceeding 1.5 Mtr above the starting point all as directed. |
| 108 | Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement only punned thickness shall be considered for paymet. |
| 109 | Material and Labour for well burnt subclass ‘B’ bricks as mechanicalprotection forunder ground LT electric cables laidalong with length of the bricks equal to the width of the trench complete all as speified and directed . |
| 110 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material to out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 111 | Supply and Fixing GI tubing light grade 100 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 112 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 150 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 113 | Material and labour for 3.5 core 240 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed.Make : Havells/ Polycab/ RPG AsianNote - Earthwork and bricks to be measured paid separately in respective items. |
| 114 | Material and labour for 3.5 core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed.Make : Havells/ Polycab/ RPG AsianNote - Earthwork and bricks to be measured paid separately in respective items. |
| 115 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable size 150 to 185 Sqmm 3.5 core of underground LT armoured cables complete all as specified and directed.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 116 | M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm laid and spreaded in sub - station yard complete all as directed and specified. |
| 117 | Supply, installation, testing and commissioning LTpanel CPRI Testedof suitableSize andsuitable for 3 phase 415 Volts of suitable size made out of 3.15mm thick CRCA sheet of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 1000 Amp and including PCC foundation in (1:2:4) type B-1 using 20mm graded stone aggregate as per site requirement to accomodate to the following :-INCOMING(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 630 Amp, 50 KA - 01 No (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a)MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No(b)MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 25 KA - 01 No(c)MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 16 KA - 03 Nos |
| 118 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262, IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india. The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one Nopolycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :- |
| 119 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 25 KA- 03 Nos.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 100 Amps, 10 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS). |
| 120 | Material and labour for 3.5 core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed.Make : Havells/ Polycab/ RPG AsianNote - Earthwork and bricks to be measured paid separately in respective items. |
| 121 | Material and labourfor 3.5 core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed.Make : Havells/ Polycab/ RPG AsianNote - Earthwork and bricks to be measured paid separately in respective items. |
| 122 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable size 95 to 120 Sqmm 3.5 core of underground LT armoured cables complete all as specified and directed.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 123 | Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following :- |
| 124 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No(O/G).(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA- 01 No(O/G).(d) MCB SPNof 415 V of capacity 40 Amps 10 KA- 02 Nos (O/G)(e) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set(g) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 125 | Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- |
| 126 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA- 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 25 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 127 | M&L in repair of fabricatedsheet metal board of building panel /LT Panel complete with locking arrangement, fabricated out of3.0 mm thick MS sheetwith powder quotedinternal and external surfaces including taking down old unserviceable rusted sheet metal enclosure complete all as specified and directed.Note:-(a) Size Shall be decided as per site requirement. |
| 128 | M&L in repair of fabricated sheet metal board of building panel /LT Panel complete with locking arrangement, fabricated out of2.0 mm thick MS sheetwith powder quotedinternal and external surfaces including taking down old unserviceable rusted sheet metal enclosure complete all as specified and directed.Note:-(a) Size Shall be decided as per site requirement. |
| 129 | M&L Taking down of serviceable energy meters 4 to 6 Nos ofanytype ,MCB TPN /SPNDB with MCB of 1to 2 Nos , MCCB TPN DBwithMCCBs of 1 to 2 Nosfrom the rusted building main panel and refixing the same on same day after replacement of new fabricated building main panel boardcomplete all as specified and directed.Note:-(a) Concealed the DBs on wall all including making good and matching with existing surface is inclusive in the quoted rates. |
| 130 | M&L Taking down of serviceable MFM/volt meter/Ammeterof 1 to 2 Nos ofanytype ,MCB TPN /SPN of 1to 2 Nos , MCCB TPN /4 Pole of 1 to 2 Nosfrom the rustedLT panel / Feeder pillar Box and refixing the same on same day after replacement ofnew fabricated frame of LT panel / Feeder pillar Box complete all as specified and directed.Note:-(a) PCC foundation of suitable size in (1:2:4) type B-1 using 20mm graded stone aggregate is inclusive in the quoted rates. |
| 131 | S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 132 | S&F in replacementfactory madepowder coated distribution board TPN, 6 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 133 | S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ Havells/ Indo Asian |
| 134 | S & F in repair MCB single pole 240 volts 6 to 32 Amps \"C\" series 10 KA breakingcapacitycomplete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 135 | Supply and fixing of Aluminium Bus Bar of existing Size in the existing panel board on site of required shape post insulator with removing and refixing of existing UG cable complete all as specified and as directed . |
| 136 | Supply and fixing of copper Bus Bar of existing Size in the existing panel board on site of required shape post insulator with removing and refixing of existing UG cable and complete all as specified and as directed . |
| 137 | Supply and fixing in repair LED Indicating lamp (R-Y-B) complete all as specified and as directed. |
| 138 | Welding of two MS/GI Sheet /Pipes on site including grinding the welded portion and making smooth surface complete all as specified and as directed. |
| 139 | M& L for preparation to internal and external old steel surface of Main building Distributation Board / LT Distributation Board of various size and completely removal of existing treatment by scraping etc and surface painted with Synthetic enamel paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed. |
| 140 | S&F ofSingle pole and neutral enclosure with a two pin and earth plug and socket complete with single poleMCB 32 Amps complete all as specified and as directed .Make Legrand/Schneider /ABB |
| 141 | Supply and fixing of MCB TP 415 Volts, \"C\" series, breaking capacity 10 KA of rating 40-63 Amps complete all as specified and as directed . Make : Legrand /Schiender/Indo Asian |
| 142 | Material and labour for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be measured paid separately in respective items. |
| 143 | Material and labour for 3 ½ core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be measured paid separately in respective items. |
| 144 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262, IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one Nopolycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 360 A current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- |
| 145 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 36 KA 4 Pole - 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps, 10 KA - 03 Nos.(c) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS). |
| 146 | Supply and Fixing GI tubing light grade 50 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 147 | Material and labour for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG AsianNote - Earthwork and bricks to be measured paid separately in respective items. |
| 148 | Material and labourfor 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be measured paid separately in respective items. |
| 149 | Material and labour for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG AsianNote - Earthwork and bricks to be measured paid separately in respective items. |
| 150 | M&L plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed. |
| 151 | M & L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in coping/collar of poles including necessary form work complete all as specified and directed. |
| 152 | M&L for GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws,with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9M including necessaryEarth work,PCC foundation copping etc and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed . |
| 153 | Supply and fix GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.5 mtr long bent to shape as directed, fixed on poles with necessaryclamp of required size suitable for steel tubular pole including suitableGInuts and bolts washers complete all as specified and as directed . |
| 154 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No., MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 155 | Supply and fix PVC insulated Copper Conductor Cable 1.5 Sqmm, FRLS 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex or equivalent |
| 156 | M&L for Octgonal GI poles complete with GI base plate finial taper plug, bolts, nuts and screws,with suitable bracketall as specifiedof height 7 M including 6 Amp single pole MCB with 32 Amp connector/ terminal necessaryEarth work,PCC foundation copping etc and refixing of all existing fitting fixture from existing old electric pole complete all as specified and as directed Make - Philips /Bajaj/Havells/CG |
| 157 | M&L as in repairenergy efficient street light luminaire LED type 70watts,with light sensor, IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KVSPD fixing in cable junction box complete all as specified and as directed. Make - Philips /Bajaj/Havells/CG |
| 158 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and as directed :- |
| 159 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps, 25 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63Amps, 10 KA- 06 Nos.(c) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 160 | Supply and fixing in repair building security/ LED street light fitting 35/36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 161 | S & F in repairs street light bracket made up of GI tubing 32 mm dia light grade of length 1.0 mtr bent to a shape with 2 Nos clamp of suitable size made of GI flat incl nut, bolt and washer for fixing on wall complete all as specified and directed. |
| 162 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 163 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 164 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 165 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 166 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 167 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 168 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 169 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 170 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 171 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 172 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 173 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 174 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 175 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 176 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 177 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 178 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 179 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 180 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 181 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 182 | M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global |
| 183 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 184 | Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size min200mm x 300mm or dia 200 mmand size shall be square / oval as per site requirement duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means withnecessarycement concrete andpainting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed. |
| 185 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out unserviceable old LT panel board andreconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- |
| 186 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 315 Amp, 36 KA - 02 Nos (Incomer).(b) On Load Change over front operated of capacity 315 Amp, 4 Pole, 415 V - 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KΑ - 01 (O/G).(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCBfor 3 Phase Supply - 01 set (f)Space for spare feeder - 01 No.Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS). |
| 187 | Point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSHcable 1100 volts grade with stranded copper conductor in and including rigid steelERW conduit and conduit accessoriesin wall, floors and ceiling including PTFE(Teailon) type sealing of joint along with continuous earth wire 1.5 Sqmm PVC insulated and unsheathed single core FRLSHcable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and includingsuitable standard accessories complete for one No. flame proof light point/ one fan point /one exhaust fan controlled by one way flame proof switch all as specified and directed.Make of Cable : Plaza/ Polycab/ Havells |
| 188 | Supply and fixing LED light fitting 1X20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable (FRLSH) with suitable size.Make : Sudhir/Baliga/Shyam Switchgear/Crompton |
| 189 | Supply and fix Switch flame proof rotary type with termination box in LM6,16 A, single pole 250V complete all as specified and directed. Make : Sudhir/Baliga/Shyam Switchgear |
| 190 | S&F flame proof junction box with spigotted cover in LM-6, three way/terminal block 3/4 way strip type cable entry, 20 mm dia hole aluminium constructed, internal dimension 80 mm dia and 40 mm depth, duly approved by CMRI Dhanbad complete all as specified and directed. Make:- Shyaam Product Cat No SSPL/JB/105 or equivilent in Baliga / Flaxpro/ Sudhir |
| 191 | S&F flame proof cast iron enclosure distribution board 415 volts, 6 way, SPN and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoingand including making good to the disturbed surfaces of walls, floors etc.complete all as approved by CMRI Dhanbad with following incoming and outgoing controls all as specified and directed:- (i)Incoming:- MCB, 2 Pole 32 Amp -01 Nos (ii) Outgoing:- MCB 1 Pole 6-32 Amp - 04 Nos. with complete internal bus bar & wiring up to terminals Make:- Shyaam Product Cat No SSPL/MCDB/186 or equivilent in Baliga / Flaxpro/ Sudhir |
| 192 | Supply and fixingflame proof, heavy duty metallic Exhaust fan of 300 mm, single phase, 230 V, 50 Hz with all accessories,prewired includingnecessary electric connection, louvers and making of holes of suitable sizes in wall of any description and finishing surfaces complete all as specified and as directed. Make : Sudhir/Baliga/Shyam SwitchgearNote: Old U/s Exhaust Fan shall be deposited to MES Store yard. |
| 193 | Supply and install, testing commissioning of RO Plant (Reverse Osmosis+Ultra Violet+TDS Controller) high purification capacity of 1000 Ltrs/Hrs, Duty Cycle 16 Hours (max) with following Accessories :-(a) Electronic Water Conditioner(b) Raw Water Pump :- (i) Type : Horizontal Pump (ii) Type of Drive: Three Phase, 415 V AC, 50 Hz (iii) Capacity:1800 lph minimum (iv)Discharge Pressure: 3Kg / cm2(c) Pressure Sand filter :- (i) Type: Vertical with Manual Multi Port Valve system (ii) M.O.C. of Vessel: FRP (iii)Frontal Pipe Work : UPVC (iv) Operating Pressure:3.5 kg/cm2 (v) Type of Valve: Multi-Port Valve (vi) Filtering Media: Pebbles Chips, Sand and Gravels |
| 194 | (d) Activated Carbon Filter :- (i) Type : Vertical with Manual Multi Port Valve system (ii) M.O.C. of Vessel : FRP(iii) Frontal Pipe Work : UPVC(iv) Operating Pressure:3.5 kg/cm2(v) Type of Valve:Multi-Port Valve(vi) Filtering Media:Activated Carbon - 900 IV & Chips(e) Antiscalant Dosing System:-(i) Type of Dosing Pump : Electronic Metering Pump(ii) MOC of Tank: HDPE(iii) Capacity of Pump:0 – 6 LPH(iv) Capacity of tank: 100 Ltr.(f) Micron Cartridge Filter :-(i) Type of Cartridge : Replaceable(ii) Material of Cartridge : Spun(iii) Quantity of Cartridge : Two Nos.(iv) M.O.C. of Housing : PP(v) Diameter of cartridge: 4 inches(vi) Length of Cartridge :20 inches(vii) Cartridge Rating: 5 micron |
| 195 | (g)High Pressure Pump:-(i) Type : Vertical, multistage, centrifugal(ii) M.O.C. of Pump : SS 304(iii) Type of Drive : Three phase, 50Hz, 415V(iv) Capacity : 1800 LPH(h) Reverse Osmosis System :-(i) Type of Membrane :Composite Polyamide(ii) M.O.C. of Membrane : Polyamide(iii) No. of Membrane : 4 Nos.(iv) Size of Membrane: 4” x 40” (D x L)(v) MOC of Membrane Housing : FRPMake Of The RO Plant : Make in India Make with ISO Certified company |
| 196 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and including suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 SqmmPVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 197 | S&F factory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 198 | Supply and fixingMCB TPN 415 Volts, \"C\" series, breaking capacity 10 KA of rating 40-63 Amps Make : Legrand /Schneider/Indo Asian |
| 199 | Material and labour for 4 core 6 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 200 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 4 Sqmm drawn through in and including suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 SqmmPVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)4 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 201 | S & F MCB single pole 240 volts 6 to 32 Amps \"C\" series 10 KA breakingcapacity complete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian. |
| 202 | S&F Electronic energy meter 3 Phase 30 to 60Amps range capacity complete all as specified and directed. Make : BENTEC / L&T/ABB. |
| 203 | Supply and fixing25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 204 | Supply and fixingChlorinated PVC Gate Valve of size 25 mm dia (ISI marked) complete all as specified and as directed. |
| 205 | Supply and fixing20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 206 | Supply and fixingChlorinated PVC Gate Valve of size 20 mm dia (ISI marked) complete all as specified and as directed. |
| 207 | Cutting existing water supply of 50mm dia bore main line in position for insertion of specials / fittings viz Tee etc. of suitable size for making branch connection including testing after completion complete all as specified and directed. |
| 208 | S&F PVC water tank 2000 ltr capacity, rotational moulded poltethylene water storage tanks (cylindrical vertical with clossed top) hoisted and fixed in position all as specified in SSR Part 1 including S&F ball brass valve, 25mm dia bore, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 209 | M&L mild steel framed work such as grills, grating, etc with ends of bars shouldered and/ orriveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 210 | M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces and all as specified and directed. |
| 211 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in soft/loose soil,returning, filling in and ramming earth or broken rubble mixed with earth ground, in layers not exceeding 25 cm and making good surface and all as specified and directed. |
| 212 | M&L forcement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as infoundation, filling and mass concrete complete all as specified and directed. |
| 213 | Material and labour for providing plain pement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 214 | M&L forPCC typeBI 1:2:4 using 20 mm grade aggregatefor flooring complee all as specifed and directed |
| 215 | Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar ( 1:6) complete all as specified and directed. |
| 216 | M&L for rendering 15mm thick in cement mortar (1:4) onbrick or concrete surfaces of wall and finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 217 | M&L for preparation of newly or untreated plastered surface and applying two coat of oil bound distemper complete all as specified and directed. |
| 218 | Note :- An amount of Rs 1,55,725.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail