| 1 | Supplying & fixing suitable size GI box with modularplate and cover in front on surface or in recessincluding providing and fixing 25 A modular socketoutlet and 25 A modular SP MCB, \"C\" curve includingconnections, painting etc. as required |
| 2 | Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. as required |
| 3 | 5/6 amps switch |
| 4 | 3 pin 5/6 amps socket outlet |
| 5 | 15/16 amps switch |
| 6 | 6 pin 15/16 amp socket outlet |
| 7 | Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 9 | 25 mm |
| 10 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required |
| 11 | 6 Module (200mmX75mm) |
| 12 | 8 Module (125mmX125mm |
| 13 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 14 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired. |
| 15 | 1 x 1.5 sqmm |
| 16 | 2 x 2.5 sqmm |
| 17 | 2x 4 sqmm |
| 18 | 2 x 6 sqmm |
| 19 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V 50 HZ , Single phase AC supply , earthing etc complete as reqd |
| 20 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 21 | Above 95 sqmm and upto 185 sqmm |
| 22 | Upto 35 sqmm |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections etc. as required |
| 24 | 400 A . 35 KA . TPMCCB |
| 25 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 26 | Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 27 | Supply, Installation, testing and commissioning of pre-wired, 70 watt, Street Light luminaire delivering >100 lumen/watt with PDC housing, 220-240 V, 50 Hzon existig street light pole/wall including all accessories and connection etc.as required. Make Philips, Cat No. BRP032 P LED75 CW SLR PSU GR SPD or equivalent model of Thorn/Trilux |
| 28 | Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site. |
| 29 | Supply, Installation, testing and commissioning of pre-wired, 45 watt, IP 65, Post top lantern light have symmetric light distribution, 220-240 V, 50 Hzcomplete i/c all accessories etc. directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips Uniscape Model, Cat No.BGP200 LED45 CW PSU GR CPC SPD or equivalent model of Thorn/Trilux |
| 30 | Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade ofsize 4C X 16 sqmm etc as required. |
| 31 | 4 x 16 sqmm |
| 32 | Supply, installation , testing and commissioning of 1 HP , Direct on line starter with sheet steel enclosures suitable for 1-phase, 220V , complete set with contractor & OLR , start , stop push button with indicator lamps, voltmeter, ammeter, including mounting arragement of starter with all accesories etc. as required. Make Havells URJA- DOL submersible pump controller (Standard )- 1 Phase , Cat No. IHADOAJ1FD or equivalent model of crompton/BCH Electric |
| 33 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 34 | Supplying , installation, testing and comissioning of 4 pin LED PLL tube 18 watt 1800 lm input voltage 220- 240 volt 50 Hz complete as required . Tube equivalent to philips Make Cat no. LED PLL 18W 6500K 2G11 |
| 35 | Supplying and Fixing of snap-on DLP trunking of size 105mm x 50 mm with cover and including accessories such as cover, Flat angle, end caps, internal/external angle support etc. on the wall/surface complete all as requied |
| 36 | Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hzon existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No.BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux |