| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil for road to required slope gradient, camber etc complete all as specified and directed by Engineer-in-Charge. |
| 2 | Excavating in trenches, n.exc 1.50 m wide and n.ex. 1.50 m in depth for foundation, etc or for shafts, wells cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.50m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removing excavated surplus soil n.exc 50 m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for sand filling under floors or in foundations, cushioning to inter locking tiles / paver blocks, cushioning to under ground cables and the like including watering and consolidation as required complete all as specified and directed by Engineer-in-Charge.Note: (i) Sand cushioning to interlocking tiles/ paver blocks shall be laid & spread in a uniform layer of 40mm thickness.(ii) Sand cushioning to under ground cables shall be laid in two layers, Ist layer of 8 cm thickness shall be laid before laying of cable and 2nd layer of 15 cm thickness shall be laid after laying & stretching of cable. Overall punned thickness to be measured as 18 cm for the purpose of payment. |
| 6 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and well rammed including watering complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for PCC (1:4:8) type D2(using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for RCC M-30 (Design Mix) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for RCC M-30 (Design Mix)) as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for RCC M-30 (Design Mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for RCC M-30 (Desgn Mix) as in chajjas and the like complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for RCC M-30 (Design Mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for applying two coats of hot bitumen blown of any grade on concrete surfaces at the rate of 1.50 Kg/Sqm per coat complete all as specified and directed by Engineer-in-Charge. |
| 14 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge. |
| 15 | S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required, including binding with mild steel wire (annealed) not less than 9mm dia complete all as specified and directed by Engineer-in-Charge. |
| 16 | Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge. |
| 17 | Use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer-in-Charge. |
| 18 | Use & waste formwork to soffit of suspended slabs such as roof slabs, floor slabs, landings and similar work, n exc 200mm thick (horizontal or sloping) complete all as specified and directed by Engineer-in-Charge. |
| 19 | Use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintes,cantilevers, shelves including supports, overhangs, etc also splays beteen floors and beams finished rough surfaces of concrete complete all as specified and directed by Engineer-in-Charge. |
| 20 | Use & waste formwork to chajjas, chullah hoods, similar items including edges complete all as specified and directed by Engineer-in-Charge. |
| 21 | Use & waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for brick work with old size sub-class \"B\" bricks in cement mortar (1:6), straight or curved on plan exc 6m mean radius in any position complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for hardcore of broken stone or boulders of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded aggregate) as in sub base and the like complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L for 10mm thick light shade virified ceramic tiles (square/rectangular), polished, area of each tile n.exc 0.36 Sqm, laid in vertical surfaces such as skirting & dados over and including 10mm thick rendering or backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for 10mm thick light shade virified ceramic tiles (square/rectangular), polished, area of each tile n.exc 0.36 Sqm, laid in flooring over and including 15mm thick screed bed or bedding layer in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F 7 to 8 mm thick non skid ceremic coloured tiles (square/rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, laid in flooring over and including 20mm thick screed bed or bedding layer in cement mortar (1:6), set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F glazed ceramic digital coloured tiles of size 450x300x7mm or 600x300x7-8mm thick, laid in vertical surfaces over and including 10mm thick rendering or backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F 20mm thick machine cut granite (of any type) tiles, laid in horizontal or vertical surfaces over and including 15mm thick screed bed or bedding layer in cement mortar (1:4), bedded and jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engineer-in-Charge. |
| 30 | M&L for rounding to edges of stone slabs (of any type) at one edge, such as in steps, cooking platform and in similar situations including grinding and polishing to match complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for 50mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in sub base, floors, coping, paving, plinth protection, finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other frames/ chowkhat of size 45 x 70 mm, comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 53 N/mm2 modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant, fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed by Engineer-in-Charge. Note: For WPC solid door/ window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 33 | S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type 30mm thick flush door shutter, comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design, pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as per directions of Engineer In- Charge. Note: All builders hardware shall be measured and paid for separately |
| 34 | M&L anodised aluminium snap grid frame work of size 605x605 mm for false ceiling and perforated particle board or tiles 12 mm thick for insulation and accoustic purposes, 60 cm X 60 cm in size including hangers 6 mm dia G.I. (upto 1200 mm length) adjusting level, fixed to roof slab by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners of 12.5 mm dia 40 mm long complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F 250 mm long mild steel sliding door bolt plate typestove enamelled black with bright bolt not less than 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer-in-Charge. |
| 36 | S&F 200mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer-in-Charge. |
| 37 | S&F 100 mm long mild steel cold rolled butt hinges medium weight and fixedcomplete all as specified and directed by Engineer-in-Charge. |
| 38 | S&F 150mm size mild steel pressed steel handle, oval type, stove enamelled black and fixed complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F 110 mm dia bore PVC (SWR) pipes, single socketed, fixed to walls in any length with rubber ring joints as in drain/rain water pipe including necessary clamps complete all as specified and directed by Engineer-in-Charge. |
| 41 | S&F 110 mm dia bore PVC (SWR) pipes, single socketed, laid in trenches in any length with rubber ring joints complete all as specified and directed by Engineer-in-Charge. |
| 42 | S&F 110 mm dia bore PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete external surfaces of walls, applied in two layers i.e. Ist layer of 10 mm thickin cement mortar (1:6) and 2nd (top) layer of 5 mm thick in cement mortar (1:4) mixed with water proofing compound as per manufacturer\"s instructions, finished even and fair complete all as specified and directed by Engineer-in-Charge.Note:- Water proofing compound shall be measured and paid for separately at supply only rates |
| 44 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces ofceiling, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L for 15mm thick rendering in cement mortar (1:6) internal surfaces of walls of any description of brick work or concrete, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for preparation of newly plastered surfaces of walls and applying two coats of Acrylic Smooth Exterior paint of approved shade @ 1.67 Ltr/10 Sqm over and including a priming coat of exterior primer @ 2.20 Kg/10 Sqm complete all as specified and directed by Engineer-in-Charge. |
| 47 | M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of priming chalk whiting on plastered surfaces preparatory to distempering complete all as specified and directed by Engineer-in-Charge. |
| 48 | M&L for preparation of newly plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of priming chalk whiting on plastered surfaces preparatory to distempering complete all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for 100mm thick M-50 grade factory made rubber moulded coloured machine pressed precast concrete interlocking paver block in approved design and colour, conforming to IS-15658-2006 with grey cement and pigment as approved, laid over and including 40mm thick sand cushion and joints filled with sand complete all as specified and directed by Engineer-in-Charge.Note - Sand for cushioning shall be measured and paid for seperatly. |
| 50 | M&L for water proofing treatment to RCC roof slab, walls, chhajjas etc complete all as specified here-in-below and as directed by Engineer-in-Charge:-(a) Providing 15mm thick plaster screed bed layer in cement mortar (1:3) mixed with water proofing compound as per manufacturer\"s instructions on concrete surfaces, finished even and fair complete all as specified. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc by brooming with broom, sweeping free from dirt, dust etc and evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (c) Supply and laying APP polymer modified approved membrane, non-woven, polyester, weighing not less than 3.5 Kg/Sqm with side / end overlaps as specified and joints sealed by torch application method all as specified.(d) Carrying out test for leakage / seepage by flooding water for 24 hrs and rectifying the defects, if any observed during flooding test to the entire satisfaction of GE. (e) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 Ltr/Sqm on the top of membrane surfaces complete all as specified and directed by Engineer-in-Charge.Note: Water proofing compound shall be measured an paid for separately at supply only rates. |
| 51 | Supply only liquid water proofing compound of approved quality all as specified and directed by Engineer-in-Charge. |
| 52 | M&L for treating theback fill in contact with foundation or soilat the rate of 7.5 litres of emulsion per square metre ofvertical surface complete all as specified and directed by Engineer-in-Charge.Note: Area of the sub structure in contact with back fill to be measured. |
| 53 | M&L for treating the top surface of filled earth, soil under floor or plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge. |
| 54 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer-in-Charge. |
| 55 | M&L for 40 mm thick damp proof course (DPC) in cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) mixed with water proofing compound as per manufacturer\"s instructions to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer-in-Charge.Note: Water proofing compound shall be measured an paid for separately at supply only rates. |
| 56 | S&F 20 mm dia bore PTMT ball valve high pressure with polylethylene float ball and fly nut complete, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F 10 liters capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve float including bracket, 32mm flush pipe and fixed in position complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F 15mm dia bore chromium plated brass angle / stop valve, fancy type, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F 15mm dia bore chromium plated brass bib tap, longbody, fancy type screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F 15mm dia bore chromium plated brass pillar tap, fancy type with capasten heads, scewed down, high pressure with or without lettered \"HOT\" or \"COLD\" with long screwed shank and fly nut, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.. |
| 61 | S&F vitreous china water closet pan \"Padestal pattern\", white, with & including plastic water closet seat, white, closed pattern with flat bottom & EWC seat cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&Fjet spray with tube for single symphonic action type for EWC seat, complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F 100mm dia CP grating with or without hole and fixed in position with white cement complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F vitreous china wash hand basin of size 450 x 550mm, oval shape, white, excluding tap but including 32mm dia CP brass waste coupling etc complete all as specified and directed by Engineer-in-Charge. Make: CERA Cat part No. 1005 or other equivalent and approved make |
| 65 | S&F15mm dia bore PVC connection 450mm long with PTMT nut with washer at both ends complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F CP brass bottle trap 32 mm dia including joining to waste fitting and waste pipe complete all as specified and directed by Engineer-in-Charge. |
| 67 | S&F vitreous china urinal half stall olymous star, white including waste pipe, Urinal spreader of PTMT of any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F600 x 450 x 5 mm thick bovelled edge looking mirror of selected quality glass with supirior quality PVC / plastic body frame, fixed to PVC plugs with CP brass screws complete all as specified and directed by Engineer-in-Charge. |
| 69 | S&F20 mm dia bore gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 70 | S&F20mm dia CP brass towel rail, D type, 60 cm long and fixed with PVC plug & CP brass screws complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F 110mm dia bore PVC (SWR) \"P\" trap complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F 75mm dia bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F 75 mm dia bore PVC (SWR) pipe, single socketed, laid in trenches or in floors in any length with rubber ring joints complete all as specified and directed by Engineer-in-Charge. |
| 74 | S&F 75 mm dia bore PVC (SWR) pipe, single socketed, fixed to walls in any length with rubber ring joints including necessary clamps complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F 15mm dia bore steel tubing, galvanised, medium grade with all fittings and fixed to walls or ceilings or laid in floors including necessary clamps etc complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F 20mm dia bore steel tubing, galvanised, medium grade with all fittings and fixed to walls or ceilings or laid in floors including necessary clamps etc complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F 500 ltrs capacity Rotational moulded polyethylene water storage tank with lid (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed by Engineer-in-Charge. |
| 78 | M&L for brick work with old size sub-class \"B\" bricks in cement mortar (1:4), straight or curved on plan n.exc 6m mean radius for man-holes/septic tank, sewer works etc complete all as specified and directed by Engineer-in-Charge. |
| 79 | M&L for 15 mm thick rendering in cement mortar (1:3) on fair faces of brick or concrete surface, finished even and smooth without extra cement complete all as specified and directed by Engineer-in-Charge. |
| 80 | M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed by Engineer-in-Charge. |
| 81 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and directed by Engineer-in-Charge. |
| 82 | S&F MS framed work such as grills, gratings, manhole covers etc with ends of bars shouldered or riveted or forged into spikes, frame work of water tanks and similar work conforming to Fe 290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge. |
| 83 | M&L for preparation of new steel & iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 84 | S&F 100mm long mild steel cold rolled butt hinges, heavy weight, fixed to steel / angle iron frame by welding, if required, complete all as specified and directed by Engineer-in-Charge. |
| 85 | M&L for 75mm thick plain cement concrete (1:2:4) type B2 (using 40mm graded stone aggregate) as in sub base, flooring, coping, paving, plinth protection and the like, finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 86 | S&F 300mm dia bore reinforced cement concrete pipes, class NP3, laid and jointed with collars complete all as specified and directed by Engineer-in-Charge. |
| 87 | M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in bed to drain pipe of 300 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engineer-in-Charge. |
| 88 | M&L for concealed point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed HFFR copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, HFFR copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases and modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed by Engineer-in-Charge for one light point controlled by one, one-way switch 06 Amps. |
| 89 | All as per Srl item No. 88.00 here-in-before but for one ceiling / exhaust fan point controlled by one, one way switch 06 Amps. |
| 90 | All as per Srl item No. 88.00 here-in-before but for one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch. |
| 91 | All as per Srl item No. 88.00 here-in-before but for one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch. |
| 92 | All as per Srl item Item No. 88.00 above but point wiring with 2.5 Sqmm single core HFFR cables and earth continuity wire of 2.5 Sqmm single core HFFR cable for one 3 pin 15 Amps socket outlet point controlled by one, one way switch on independent board complete all as specified and directed by Engineer-in-Charge |
| 93 | S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified and directed by Engineer-in-Charge |
| 94 | S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts, one module complete all as specified and directed by Engineer-in-Charge |
| 95 | S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified and directed by Engineer-in-Charge |
| 96 | S&F modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified and directed by Engineer-in-Charge |
| 97 | S&F ceiling rose, 6 Amps, 3 terminal including connection complete all as specified and directed by Engineer-in-Charge. |
| 98 | S&F modular ceiling fan regulator, 02 module, AC, 230 volts, 120 watts, duly ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 99 | S&F recess mounted compact vertical, round shaped energy saving LED down lighter luminaire 12 watts, 4000 K, 230 volts, 50 Hz complete with suitable LED driver lamp & all accessories, internally prewired including connecting up with three core twisted flexible copper conductor cable of suitable size and cutting of suitable hole in false ceiling complete all as specified and directed by Engineer-in-Charge. |
| 100 | S&F recess mounting LED luminaire2\"x2\", 36 Watts (warm white/cool white4000K), 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & LED lamp suitable for POP/Gypsum/roof ceiling and connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surfaces to match with the existing surface including making of electrical connection with & including three core flexible copper conductor cable of suitable size with all accessories complete all as specified and directed by Engineer-in-Charge |
| 101 | S&F exhaust fan, steel body AC single phase, 230 Volt of size 300m sweep with blades and frame and louvers including cutting hole in wall, making of wooden frame with all arrangements for mounting of fan and making good the disturbed surfaces to match the existing surfaces complete all as specified and directed by Engineer-in-Charge |
| 102 | S&F electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and provision & connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance anti-scaling magnesium anode having adjustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minimum two year warranty on product & minimum three years on heating element complete all as specified and directed by Engineer-in-Charge. |
| 103 | M&L for sub main wiring with 4 Sqmm nominal cross sectional area, two single-core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, HFFR copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existingcomplete all as specified and directed by Engineer-in-Charge. |
| 104 | All as per Srlitem No. 103.00 here-in-before but sub main wiringwith 6 Sqmm nominal cross sectional area HFFR copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area FRLSH copper conductor cable. |
| 105 | All as per Srlitem No. 103.00 here-in-before but sub main wiringwith 10 Sqmm nominal cross sectional area HFFR copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area FRLSH copper conductor cable. |
| 106 | S&F Industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, 20 Amps, AC, 230 Volts \"C\" curve, 10 kA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed by Engineer-in-Charge. |
| 107 | S&F LED street light fitting 35 Watt 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. |
| 108 | M&L for street light bracket made out of GI pipe light grade 32 mm dia bore 1.20 m long, bent to shape and reduced to required size at top upto 1.00 m length by cutting, welding and well finishing including 2 Nos MS clamps of flat iron of size 25x5mm of suitable length with drilling hole, fixing with nuts, bolts & washters including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 109 | S&F sheet metal enclosure DB, TPN 4 way, double door, 415 Volts, AC, surface mounting with suitable busbar, neutral link & earth link suitable for MCB TP/TPN as incomer & MCB SP as outgoing complete all as specified and directed by Engineer-in-Charge. |
| 110 | S&F MCB SP 6 to 32 Amps rating, 240 Volt, \"C\" curve, 10 kA rupturing capacity including necessary connection in MCB DB using suitable copper lugs, testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 111 | All as per Srl item No. 110.00 above but MCB SPN 40 to 63 Amps |
| 112 | S&F MCB, TPN 63-100 Amps, \"C\" curve, 415 Volts, 10 kA rupturing capacity, including necessary connection in MCB DB using suitable copper lugs, testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 113 | S&F MCB SP 40 Amps rating, 240 Volt, \"B\" curve, 10 kA rupturing capacity including necessary connection in MCB DB using suitable copper lugs, testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 114 | S&F sheet metal enclosure for 8 way Distribution Boards (DB\"s), double door, single pole & neutral with 200 Amps rated bus bar, IP-20 protection suitable for fixing MCB\"s/Isolatorsand fixed in position complete all as specified and directed by Engineer-in-Charge. |
| 115 | Supply, Installation, testing and commissioning of 1200 mm sweep. BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 Nos blades, 30 cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut & bolts, washers, temperature rise ≈75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 Volts, 50 Hz, single phase AC supply, earthing etc complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete all as specified and directed by Engineer-in-Charge. |
| 116 | S&F desert cooler of steel body size 25\"x25\"x32\", made out of corrosion resistant, 18 SWG GI sheet duly powder coated paint with 500 mm sweep copper wound fan motor kit of not less than 180 Watt with metallic blade, ISI marked, 1400 RPM, 230 Volts, AC, having nominal air flow capacity 4000 Cum per hour (or nearest size), water tank capacity not less than 100 ltr, including plastic submersible pumps, electronic fan regulator with Piano type switch, cooler stand of suitable size as directed and fixing the desert cooler toexisting window including covering the remaining window portion with 6 mm thick plywood as required size at site complete all as specified and directed by Engineer-in-Charge. |
| 117 | Supply, installation, testing and commissioning of water cooler fully stainless steel, electric driven single phase having approx storage capacity 40 ltr and nominal cooling capacity 40 ltr complete all as specified and directed by Engineer-in-Charge. |
| 118 | Supply, installation, testing & commissioning of RO Plant 50 ltr/per hr, wall mounted, having capacity to treat the raw water having TDS 1200 ppm. The treated water should have TDS less than 60 ppm and hardness less than 10 ppm or as per WHO standards. The operating voltage to 230 Volt, AC + 10%, alongwith required capacity high pressure pump and solenoid valves, dry run protection of pump, automatic tank level control, inbuilt auto flush timer for periodic flushing of membranes, over voltage and over current protection with switch mode power supply system complete in all respects including installation fittings. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall conform to ANSI/NSF 61 Section 9. Contractor will submit requiredtest report post installation of RO plant and cost shall be inclusive of 01 day training to User Staff complete all as specified and directed by Engineer-in-Charge. |
| 119 | M&L for earthing with Galvanized Steel earth plate electrode of size 60cmx60cmx6mm thick, buried directly in ground vertically at a depth not less than 2.25 m below normal ground level (NGL) with top edge of earth plate at a depth not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of GI bolts, nuts, check nuts, washers and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 (using 40mm graded stone aggregate), including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m all as specified and shown in electrical plate No. 5 of SSR (Part-I) complete all as specified and directed by Engineer-in-Charge. |
| 120 | S&F garden light fitting 10 Watts, IP65 rated LED Bollard light including necessary brick/PCC work complete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply, laying and testing 35 Sqmm 3.5 core cable XLPE lnsulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes and all fixing & connecting accessories such as cable lugs, cable glands, nut, bolts, complete complete all as specified and directed by Engineer-in-Charge. |
| 122 | All as per Srl item No. 33.00 above but cable of size 10 Sqmm 2 core |
| 123 | M&L for well burnt old size sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed by Engineer-in-Charge. |
| 124 | Supply & laying 40mm dia bore GI tubing, light grade with all necessary fittings, laid in trenches/under road crossing/fixed on pole/wall of laid under flooring including suitable mild steel FI clamps of required size complete all as specified and directed by Engineer-in-Charge. |
| 125 | Supply & laying 40mm dia bore GI tubing, medium grade, ISI marked including all fittings, laid in trenches / fixed to walls or laid in floors includingmaking good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.Note: Excavation & earth work shall be measured and paid for separately. |
| 126 | All as per Srl item No. 125.00 above but GI tubing of 25mm dia bore |
| 127 | S&F 40mm dia bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 128 | S&&F 25mm dia bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or union and fixed complete all as specified and directed by Engineer-in-Charge. |
| 129 | Cutting the existing CI / GI water supply pipeline up to 200 mm dia for inserting suitable size GI Tee and socket of size upto 40mm dia for taking branch connection for Potable water including necessary excavation and making good the disturbed area complete all as specified and directed by Engineer-in-Charge. |
| 130 | Boring holes upto 80mm bore under road pavement by bocky manually in any type of soil complete all as specified and directed by Engineer-in-Charge. |
| 131 | S&F Air circulator fan 230 Volts, single phase, oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed by Engineer-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail