| Sl. No. | Item Description |
| 1 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified & directed by Engr-in-Charge. |
| 2 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed. |
| 4 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc laid, beded and pointed in any mortar including removing the dismantled material complete all as specified and as directed. |
| 5 | M&L for Granite slab 18-20mm thick approved shade as in cooking platform, window cill and the likes, machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types andover screed bed 20 mm thick CM1:6 cement concrete complete all as specified & directed. |
| 6 | M&L 16-18mm thick green marble(table rubbed and polished) , skirting jambs, pillars, window cills, cooking platform, staircase treads and the likes; laid over with andincluding 10mm thick rendering inCM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed. |
| 7 | Taking down Chowkatts or frameswith shutters ( without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq m each & removing to store complete all as specified & directed. |
| 8 | Taking down Chowkatts or frameswith shutters (without taking off shutters from the frame n. exc 1.5 sq. m each & removing to store complete all as specified & directed. |
| 9 | S&F 1.25mm thick Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified & directed. |
| 10 | S&F 1.25mm thick Pressed steel frames 165 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified & directed. |
| 11 | M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. |
| 12 | S&F factory made solid PVC Moulded door shutter 28 to 30mm thick (Stiles) with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on front face& 2 mmplain colour PVC sheet on back face, supplying and fixing in frame at site complete all as specified & directed. |
| 13 | S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed. |
| 14 | S&F 35 mm thick 2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by Engr-in-Charge. |
| 15 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed tinned tacks or GI wire stampe or nails and screws fixed in repair complete all as specified & directed. |
| 16 | M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified& directed. |
| 17 | S&F Butt hinges 100mm long medium weight, stainless steel complete all as specified & directed by Engr-in-Charge. |
| 18 | S&F 150mm \"D\" type Aluminium handles, type, anodised complete all as specified & directed by Engr-in-Charge. |
| 19 | S&F exctruted aluminum alloy with galavanisied mild steel hing pin Butt hinges 100mm long complete all as specified & directed. |
| 20 | S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixedcomplete all as specified & directed by Engr-in-Charge. |
| 21 | S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified & directed by Engr-in-Charge. |
| 22 | S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor complete all as specified and directed. |
| 23 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified & directed. |
| 24 | Demolition of cement concrete (un-reinforced) in ground floor and paving. exc. 15 cm thickness(below or above ground level.) & removal of rubbish material complete all as specified & directed. |
| 25 | M&L for PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate), 25mm thick, as in floor complete all as specified & directed by Engr-in-Charge. |
| 26 | M&L 75 mm thick PCC(1:3:6) type C1 (using 20mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified & directed by Engr-in-Charge. |
| 27 | M&L Glazed ceramic coloured tiles in vertical surface450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified & directed by Engr-in-Charge. |
| 28 | M&L for Coloured joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed of cement mortar 1:6 complete all as specified & directed. |
| 29 | M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredmatch over 15mm thick screed bed in CM 1:6 complete all as specified & directed. |
| 30 | M&L Vetrified Ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in vertical surfaces as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over incl 10mm thick rendering in CM 1:4 complete all as specified & directed. |
| 31 | S & F mild steel cupboard shutter with frame, Godrej pattern made out of 22 guage mild steel sheet including chromium plated MS handle with proper locking arrangement (brass mortice lock vertical type size 65mm 4 lever with escutcheon plates & two keys) with & including two coats of spray painting with synthetic enamel paint of approved tint over a coat of red oxide primer including fixing with 6 Nos 12 mm dia bolt 150mm long grouted in brick wall/concrete including making good the disturbed surface asoriginal complete all as specified and as directed.Note :-The measurement shall be taken of front elevation and not girthwise. |
| 32 | S&Fanodised aluminium powder coated (Mimimum thickness of powder coating 50 micron) frame for doors, windows, ventilators, with one or more rebates including joining cleat for fixing etc complete all as specified & directed. |
| 33 | S&Faluminium powder coated (Mimimum thickness of powder coating 50 micron) window and ventilator shutters, side hung typewithout sash bars, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws,anodised aluminium fitting such as peg stays 150 mm long (01 Nos),hinges type B-1 100 mm long (2 nos) suitable handle (1 no) complete all as specified complete all as specified & directed. |
| 34 | S&F Sheet glass, ordinary quality, in squaresexc 0.5 sq. m each pane 5.5 mm in thickness complete all as specified & directed. |
| 35 | Taking down cement plaster any description on brick or stone any description complete all as specified& directed by Engr-in-Charge. |
| 36 | M&L Rendring 10mm thick in CM 1:6 onbrick work or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement complete all as specified & directed. |
| 37 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete wall surfacesfair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proof compound paid seperatly) complete all as specified & directed. |
| 38 | M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified & directed. |
| 39 | Supply only Integral waterproofing compound complete all as specified & directed. |
| 40 | Material and labour for preprationover new surfaceandapplying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance exterior paint emulsion of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm complete all as specified & directed. |
| 41 | Material and labour for complete removal of existing treatmentfrom stone wall /plastered wall andapplying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance,exterioremulsion paintof required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm over 1mm thickwall care putty over prepared surface to achieve the surface even and smooth for paintingcomplete all as specified and as directed. |
| 42 | M&L for preparing newly plastered surfaces and applying two coats of Oil bound distemper over a coat of alkali resistant primer on walls including 1mm thick wall putty complete all as specified and directed. |
| 43 | M & L for complete removing of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salt, trading oil greasy spots etc on old decorated surfaces of wall and applying two coats of oil bound distemper of approved shade/tint over a coat of primer over and inclucluding 1 mm thick Birla white wall care putty. complete all as specified and as directed. |
| 44 | M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified & directed. |
| 45 | Material and labour preparation of newly plastered/unplasteredsurfaces of ceilings & applying three coats of white wash complete all as specified & directed. |
| 46 | M & L for brooming down old decorated surfaces of walls, plastered or unplastered including cornices, plasters etc and applying one coats of white wash complete all as specified and as directed by Engr- in - Charge. |
| 47 | All as per description of serial item No.47 here-in-above but on ceiling surfaces complete all as specified & directed. |
| 48 | Taking up or down 15mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge. |
| 49 | Taking up or down 20mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge. |
| 50 | S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floorcomplete all as specified & directed by Engr-in-Charge. |
| 51 | S&F 20mm GI tubing Medium grade fix to wall/floorcomplete all as specified & directed by Engr-in-Charge. |
| 52 | Dismantling water tanks of capacity exc 250ltr but not exc 500ltr and removing from site complete all as specified & directed by Engr-in-Charge. |
| 53 | S&F Rotational moulded polyethylene water storage tanksof 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engr-in-Charge. |
| 54 | S&F ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 15 mm diacomplete all as specified & directed by Engr-in-Charge. |
| 55 | Dismantling of 100 mm bore PVC(SWR) drain pipe alongwith fittings and accessoriesjointed in cement mortar and taking out from walls, floors or fromtrenches, if required complete all as specified and directed. |
| 56 | S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified & directed by Engr-in-Charge. |
| 57 | S&F PVC (SWR) bends any radius 110 mm borecomplete all as specified & directed by Engr-in-Charge. |
| 58 | S&F PVC (SWR) vent cowl 110mmcomplete all as specified & directed by Engr-in-Charge. |
| 59 | S&F PVC (SWR),110mmjunction single, (Single T) equal or unequalcomplete all as specified & directed by Engr-in-Charge. |
| 60 | Dismantling of 75mm bore PVC(SWR) drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or fromtrenches, if required complete all as specified and directed. |
| 61 | S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed. |
| 62 | S&F PVC (SWR) bends 75mm dia any radius complete all as specified & directed. |
| 63 | S&F PVC (SWR) junction single(Single T) equal or unequal 75mm dia complete all as specified & directed. |
| 64 | S&F in repair Grating doom 100 mm dia of chromium plated (Minimum weight 25 gms) fixed with cementcomplete all as specified & directed by Engr-in-Charge. |
| 65 | S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed by Engr-in-Charge. |
| 66 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cementcomplete all as specified & directed by Engr-in-Charge. |
| 67 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 68 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, cooler stands (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC 1:2:4 type B-0 to match the existing floor complete all as specified & directed. |
| 69 | M&L for flat iron as in hold fast, hooks, cleats welded to angle iron door/window frames etc complete all as specified and directed. |
| 70 | Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 71 | Cutting holes in brick/stone walls n. exc. Half brick built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and directed |
| 72 | S&F in repairsstainless steel rod of 25 mm inner dia (in lengths as directed)including decorative finial at both ends and pair of stainless steel brackets fixed at both ends with rawl plug & steel screws on walls/beam,all as specified & as directed. |
| 73 | Demolition of Roofs, floors (other than ground floors), beams staircases, landing, chajjas, & similar suspended work Cement concrete (reinforced) complete all as specified and directed. |
| 74 | M&LRCC (nominal mix) type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified & directed. |
| 75 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 76 | S&F in repair PVC connection pipe, 15mm dia & 600mm long with adopter and washer at both end complete all as specified & directed by Engr-in-Charge. |
| 77 | S&F in repair fancy type bib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed bore in dia 15mm complete all as specified & directed by Engr-in-Charge. |
| 78 | S&F in repair white vitreous china wash hand basin \"Flat back\" of size 450x300mm fixed on and including new brackets CP waste coupling and PVC Waste pipe complete all as directed by the Engr-in-charge. |
| 79 | S&F in repair concealed stop wall /angle valves,fancy type, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm diacomplete all as specified & directed by Engr-in-Charge. |
| 80 | S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed. |
| 81 | S&F PVC waste pipeof 32mm bore of suitable length for WHB/Urinal/sink complete all as specified and directed. |
| 82 | S&F Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 83 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 84 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 3330mm x 160mm complete all as specified and directed. |
| 85 | S&Fin repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified& directed by Engr-in-Charge. |
| 86 | S&F in repairs, vitreous China squatting pan, \"Orissa\" pattern, size 580 x 440 mm, white with integral foot rest and \"P\" or \"S\" trap, including provision of Cement concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing surface all as specified and directed. |
| 87 | S&F in repairs PVC low level flushing cistern 10 litrs capacity (white ISI marked) with inlet ball valve,float and handle, syphonic action type including brackets and flush pipe of polythelene of low or high density of PVC 32mm dia for LLFC make Dolfine/Commander Champion, fixed in repairs, complete all as specified & directed. |
| 88 | S&F in repairs fancy type centre Hole Basin Mixer without popup waste system but including plain waste 32mm size with aerator complete cast copper alloy, chromium plated, screwed down high pressure, with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore complete all as specified & directed. |
| 89 | S&F in repair brass chromium plated shower rose 125mm size with swivel joint type including fixing to steel pipe of 15mm bore or union complete all as specified & directed. |
| 90 | S&Fin repairTubular towel rail, 20mm dia, D type, 60cm long between flanges of Brass chromium plated complete all as directed by the Engr-in-charge. |
| 91 | S&F for Stainless steel plate rack 1mm thick of size 900mm x 900mm x 250mm includingfixed with rawl plug and screws on walls complete all as specified and directed by Engr-in-Charge. |
| 92 | S&F in repairs Mirror cabinet PVC frame of size 400 x 500 mm fixed to wall with rawl plug & stainless steel suitable size screws complete all as specified & directed. |
| 93 | Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of)etcin all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge. |
| 94 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding,laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted inmin slope 1:30 over roof complete all as specified & directed by Engr-in-Charge. |
| 95 | M&L screed laid 15mm thick in CM 1:4with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified& directed by Engr-in-Charge. |
| 96 | M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. mincluding cleaning surfacesover bituminious primer complete all as specified & directed by Engr-in-Charge. |
| 97 | M&LAPP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven reinforcement/mat (center core) with thermal insulation laid by toarch application method with overlaps 100mm on length side and 100mm on the width side as per manufacture,s instructions with fabric (wt not less than 150 gms/sqm) on primed surface including two coat of refelective silver aluminium paint over APP membrane complete all as specified & directed. |
| 98 | M&L 75 mm thick PCC(1:4:8) type D2 (using 40mm graded stone aggregate ) as in sub base complete all as specified& directed by Engr-in-Charge. |
| 99 | M&L for 25mm thick Sand cushioning under floors complete all as specified and directed |
| 100 | S&F for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and no pigment laid over sand cushing complete all as specified & directed.Note :- Sand cushioning will measured and paid seperately. |
| 101 | M&L PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified& directed by Engr-in-Charge. |
| 102 | M&L Plain cement concrete 1:3:6 type C-1 (using 12.5 mm graded stone aggregate) set in cement mortar 1:4 as in kerb blocks with plain fair faces including chamfered weathering throating etc complete all as specified& directed by Engr-in-Charge. |
| 103 | Precast RCC (1:2:4) type B-1 in manhole/soack well/septic tanks slabs/covers etc including necessary form work complete set in cement mortar 1:6 complete. |
| 104 | M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders;coller stand ,framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 or E-165 complete all as specified & directed. |
| 105 | M&L for Rough cast plaster on exterior walls applying the under coat of cement and sand mortar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even .The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified & directed. |
| 106 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified & as directed. |
| 107 | S & F for Pipe Supporting Clamping - Single Pipe of dia 4\" (110 mm) down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt R/M System running vertically with wall distance 3\": Pipe Support Clamping made of 1. Profile Bracket having Wall Distance 3\" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted \"C\" Channel with ribs to be used of size 10\" made of Low Carbon Hot Roll Gauge Corrected (HRGC) steel (IS 1079 DD) are Hot Dip Galvanzied+ Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated.Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns).Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 3\" - 2 Nos. 2. Continuous Slotted C Channel of Size 10\" - 1 No.; 3. U Bolt R/M for 4\" (110 mm) CI or PVC Pipe Dia. - 1 No.; and 4. Justi Khilla 2 1/2\" Zn coated - 4 nos.Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the Technical Drawing No. : CE Jaipur Zone - Jaipur; TD/2022/102.Make: Shaivi or equivalent as approved by GE. |
| 108 | S & F for Pipe Supporting Clamping - Single Pipe of dia 3\" (75 mm) down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt R/M System running vertically with wall distance 3\": Pipe Support Clamping made of 1. Profile Bracket having Wall Distance 3\" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted \"C\" Channel with ribs to be used of size 10\" made of Low Carbon Hot Roll Gauge Corrected (HRGC) steel (IS 1079 DD) are Hot Dip Galvanzied+ Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated.Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 3\" - 2 Nos. 2. Continuous Slotted C Channel of Size 10\" - 1 No.; 3. U Bolt R/M for 3\" (75 mm) CI or PVC Pipe Dia. - 1 No.; and 4. Justi Khilla 2 1/2\" Zn coated - 4 nos.Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the Technical Drawing No. : CE Jaipur Zone - Jaipur; TD/2022/102. Make: Shaivi or equivalent as approved by GE. |
| 109 | S & F for Pipe Supporting Clamping - Single Pipe of dia 3/4\" (20 mm) down take pipeline fixing done with Clamping System consists of Mono Bracket + U Bolt R/M system running vertically with wall distance 3\": Pipe Support Clamping made of 1. Mono Bracket for 3/4\" (20 mm) pipe having Wall Distance 3\" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD); material size 48 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns).Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material GradQty. for one unit: 1. Mono Bracket for 3/4\" pipe, Wall distance 3\" - 1 Nos. 2. U Bolt R/M for 3/4\" (20 mm) GI / UPVC/ CPVC pipe Dia. - 1 nos and 3. Justi Khilla 2 1/2\" - 2 nos.Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the Technical Drawing no. : CE Jaipur Zone - Jaipur; TD/2022/102.Make : Shaivi or equivalent as approved by GE. |
| 110 | Treatment for sunken portion is as follows:-M&L for water proofing treatment in sunken floors as described hereunder:-1) Demelotion of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed.2) PCC (1:2:4) type B0, covered filling in sunken portion 75mm thickness shall be provided at the junctions of RCC slab and adjoining walls.3) Sunken floor and sides upto finished floor level shall be plastered with 15mm thick plaster in CM 1:4 wixed with WPC@ 3% by weight of cement.4) Applying bitumen primer of sunken floor & side surfaces TANKMASTIC of M/s STP Ltd @ 0.40 ltr/Sqm.5) Sunken portion shall be filled with lean concrete (1:5:10), Type E-2 using 40mm aggregate after carring out of satisfactory testing of CIpipes/Joints & Slab/walls by filling water 72 hrs. The sunken portion of Nahani trap/floor trap and pipes, joints shall be emmbeded in PCC (1:3:6) blocks6) GI Spout pipe 32mm dia and 450mm long cross cutted ends shall be inserted at the time of repair to Sunken portion as directed.Note:- i) In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical& tested again. This process of grouting and testing shall be repeated till leakage/seapage/dampness is elimaneted ii) Horizontal flat area only measured.iii) Above aspets are deemed to be included in quoted rate. |
| 111 | Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately),and making good disturbed surfaces of walls, floors etc to match with existing surfaces. |
| 112 | M&L for concealed Point wiring for One Light point controlled by one, one way switch with two single core PVC insulate, unsheathed multistranded copper conductorcable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floorincluding PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with modular sheet top cover of required module with frame for mounting switches, sockets etc complete all as specified. Note -(a) Quoted rates shall be deemed to include the cost of Cutting Chases in Stone/Brick wall and making good to the disturbed surfaces including plastering andpaintingto match with the existing colour. (b) The rates Quoted by the contractor shall be deemed to include the cost of modular cover plates of required module with frame, cost of Sheet Metal Box and no additional payment shall be made on account of the same. |
| 113 | All as per srl item No 112.00 but for One ceiling/exhaust fan/Fresh Air Fan point controlled by one switch and regulator |
| 114 | All as per srl item No 112.00 but for One 3 pinswitch socket outlet, 5 Ampon the same board with other switches. |
| 115 | All as per srl item No 112.00 but for One 3 pin 5 amps switch socket outlet pointon independent board. |
| 116 | All as per srl item No 112.00 but for One bell/buzzer point controlled by one bell push. |
| 117 | All as per srl item No 112.00 but for Two way point controlled by two way switch. |
| 118 | All as per srl item No 112.00 but for wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for 15 amps power point. |
| 119 | All as per srl item No 112.00 but for wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 2.5 sq.mm for 15 amps power point. |
| 120 | Supply and fixing Modular switch, one way 6 Amp, 1 module, piano type, 230/250 volts grade on top covers (catered in point wiring above). |
| 121 | All as per srl item No 120.00 but forModular switch, two way 6 Amp, 1 module |
| 122 | All as per srl item No 120.00 but forModular switch, one way 16 Amp, 1 module |
| 123 | All as per srl item No 120.00 but for Modular bell push 6 Amp, 1 module |
| 124 | Supply and fix Modular socket outlet 2in1, 3pin 5A, 2 module multipurpose use, flush mounting type, 230/250 Volts grade on Top covers (catered in point wiring above). |
| 125 | All as per srl item No 124.00 but for Modular socket outlet 2in1, 3 pin 15 Amps flush type |
| 126 | Supply and fix LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffisure duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd <10 and PF>0.95 complete all as specified and directed make - Crompton Cat Part CIS-305-40-57-SL-DP-NWH, Philips Cat part BN308C LED20S-6500 L120 PSU WH, Havells Cat Part Stella 20 Watt Galmtube LHEWAJPGPV1D020 |
| 127 | Supply and fix lamp holder insulated body with back plate for angle/batten fitting with LEDof 09 watt complete all as specified and as directed. |
| 128 | Supply and Fixing 20 watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours.Make : - Havells/Philips/Bajaj |
| 129 | Supply and fix wall mounted decorative lamp holder aesthetically designed with elegant frosted glass casing in durable metallic housing inbuilt with bulb holder two pin or Screwed type includinginsulated body with back plate for angle/batten fitting complete all as specified and as directed. Make/Model : Havells : Floretine WL1LSE27SSLHFOAJD1TZ1I060/Phillips Nerobless/Bajaj/Crompton |
| 130 | Supply and Fixing 12 watt capacity emergency LED inverter bulb B-22 with tri colour control (Cool White/Warm White/Natural White) with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours.Make : - Havells/Philips/Bajaj |
| 131 | Supply and fixing in replacement LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :-(a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 132 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-In-Charge |
| 133 | Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps. |
| 134 | Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbarflush/surface mounting double door including wooden board. |
| 135 | Supply and fix Vertical MC DB distribution box 3 phase TPN 4 ways double doorincluding MCCB 125 Amp 16 KA as incommer with bus bar rating 200 Amps vertical type dust and vermin proof complete all as specified and as directed. |
| 136 | Supply and fix MCB single pole 240 volt 6-32 amps 10 KA, complete all as specified and as directed. |
| 137 | Supply and fix MCB SPN 240 volt 32 amp 10KA complete all as specified and as directed. |
| 138 | S&F sub main wiring on and includingpassing through PVC conduit in concealed (including cutting chasis in stone/brick wall) 1100 Volts grade with PVC flexible cable copper conductor cablefire resistant low smoke and halogen (FRLSH) unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductorunsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing U/S sub main wiring. (Note:Two runs of cable with one run of earth wire and one run of PVC Coundit shouldmeasured as one length) |
| 139 | Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level connected to GIwire 4mm dia by means of bolts, nuts, check nuts and washers completeincluding earthing pit, Chemical compound, GI wire 4mm dia up to 7.5 m, 20 mm dia medium grade GI watering pipe, G.I. protection pipe 40mm diaeath pit in PCC 1:2:4 type B-1 using 20 mm graded stone agggragate RCC pit cover including earth work complete all as shown electrical palte No-3 of SSR-2009 (Part-I) NOTE:-The unit rate shall include for excavation & earth work in any type of soil/strata, PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @150mm C/C both way, funnel with watering pipe 20 mm dia medium grade, 15mm dia light grade GI pipe up to 7.5 mtr long, wiremesh complete all as specified and directed. |
| 140 | S&F Modular Type AC Box with socket 3 in 1 32 Amps Capacity and complete with 01 single pole 32 Amps 240volts, MCB complete incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified as directed by Engr-in-Charge. |
| 141 | Supply and fixing in replacement energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting with old bracket any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) |
| 142 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed.Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 143 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil. |
| 144 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil. |
| 145 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified. |
| 146 | M/L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS)laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed. |
| 147 | M&L for dry sand and punning for cushioning to under ground cable all as directed.Note :- For the purpose of payment only punned thickness shall be measured. |
| 148 | M/L for GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including clamps complete of 40 mm bore |
| 149 | Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance,for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following :- Distribution Panels under Stair Cases of JCO Blocks- 6 Qtrs(a) MCCB 4 pole 415 Volt, 200 Amps ,Adjustable thermal and magnetic release rupture capacity 36 KA - 01 No (incoming).(b) MCB 4 pole 415 Volt, 40 Amps SPN, Adjustable thermal and magnetic release rupture capacity 36 KA-8 Nos (Outgoing). The Compartment should be suitably spacious with 08 Nos of partitions of Size 450 mm x 300 mm Each for mounting of Smart Energy Meters along with these MCB\"s[c] Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No[d] Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No[e] Aluminium strip bus bars with colour code PVC insulation 300 Amps capacity - 01 Set[f] Indicators RYB - 01 Set[g] Earthing terminals and cable glands.(h) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.[j] Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door. |
| 150 | Supply and fixing in repair 25 mm bore of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittingslaid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviciable pipe complete all as specified and directed.Note :-Excavation and Earth work will be measured and paid separately |
| 151 | All as per srl item No 150.00 but for 15 mm bore |
| 152 | Disconnecting form elect connection andtaking down carefully the existingCeiling fan/Exhaust fan/Geyserof any capacity, any make,any size and depositing the same Ceiling fan/Exhaust fan/Geyser inAGE E/M store yard all as specified and directed by the Engineer-in-Charge.Refixing the same Ceiling fan/Exhaust fan/Geyser carefully including necessary repair work for making functional the same and making electric connections complete all as specified and as directed. Note : Rates quoted by the contractor shall be deemed to include the cost of minor repair work of Ceiling Fan, Exhaust Fan and Geyser like replacement of Capacitor, bearing, fan rod etc in case of Ceiling Fan/Exhaust Fan if found unserviceable and replacement of thermostatein case of Geyser etc. |
| 153 | Disconnecting form elect connection andtaking down carefully the existingelectric energy meter of any capacity, any make,any size and depositing the same electric energy meter inAGE E/M store yard all as specified and directed by the Engineer-in-Charge.Refixing the same inside the LT Panel Box with Meter Compartments carefully incl necessary electric connections complete all as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail