Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Bank protection work |
| 2 | Earthwork in cutting river bank etc. to the design section and grade and removing the spoils to a safe distance including cutting uprooting and removing trees upto 15cm dia, uprooting and removing roots and stumps etc., including excavating the earth boulder sausage of 1.00m dia, 50cm under river bed shape,size and grade etc. with all lead and lift, complete as directed. |
| 3 | Collection of hard broken stone of size 13 mm to 38 mm from blasted boulder free from dust and dirt and foreign materials including stacking at quarry site, complete as directed. |
| 4 | Collection of one man size 25 cm to 30 cm hard river boulder including stacking in measurable stacks of not more than 1.00 M height at quarry site and making payment of forest royalty etc, complete as directed. |
| 5 | Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed. (A) For normal road upto 25.0 Km (ii) With Contractor\"s Profit & GST |
| 6 | Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed.(B) For 1st KM of Quarry Road(ii) With Contractor\"s Profit & GST |
| 7 | Labour charge for spreading hard river gravel/broken stone of size 13mm to 38mm to the required thickness including ramming, dressing the seat before laying the materials as directed with lead up to 30m & lift upto 1.5m complete as directed. |
| 8 | Labour charge for pitching with one man size boulder including dressing and ramming the seat to proper size and slope, pitching etc. with local carriage of boulders from a distance of 60 M with lift upto 3 M, complete as directed. |
| 9 | Construction of 1.00 M square boulder sausage including supplying of materials with 25 cm to 30 cm size boulders collecting from a lead of 25 KM encased in 15 cm mesh of 8G hexagonal wire netting and filling the voids between the boulders with stone not exceeding 18 cm in size tied with 8G galvanized tying wire at 30 cm apart, laid in position as directed including necessary local carriage of materials, paying necessary forest royalty including providing 1 (one) no. of jati bamboo horizontal runner along the top of the sausage with vertical bhaluka bamboo post 1.20 M apart driven at least 0.60 M below ground and tying with sausage etc, all complete as directed.(ii) With river boulder |
| 10 | Construction of 6 Cusec RCC Main canal |
| 11 | Earthwork in excavation in irrigation canal to the design section and grade by depositing the spoils in the form of embankment in 15 cm layers on both banks as necessary including clearing light jungle, removing trees upto 15cm dia and uprooting roots ands tumps etc. from the seat of the embankment andcanal free from all vegetation including breaking clods not more than 10 mm cube, ramming, dressing and roughening the seat of the embankment with a lead upto 30M and lift upto 1.50 M, complete as directed . In ordinary soil |
| 12 | C.C work inproportion 1:3:6 infoundation /abutment / piers/wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing, dewatering with necessary timber shuttering, scaffolding etc. where necessary,complete as directed.(Shuttering,scaffolding cost will be paid separately). |
| 13 | Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. |
| 14 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.) (i) with 19 mm thick plyboard |
| 15 | RCC work inslab, abutment cap and above abutment, pier cap,pedestals,dirt walletc. inproportion 1:2:4 with hard broken stone aggregate of size 6mm to20 mm with proper reinforcement as per design including necessary curing, dewatering etc.complete as directed with necessary timber shuttering, scaffolding etc.where necessary, complete as directed. (Shuttering,scaffolding cost will be paid separately). |
| 16 | 12 mm cement plastering including clearing surface and curing, complete as directed. (1:3) |
| 17 | Construction of 3 Cusec RCC Main canal |
| 18 | Earthwork in excavation in irrigation canal to the design section and grade by depositing the spoils in the form of embankment in 15 cm layers on both banks as necessary including clearing light jungle, removing trees upto 15cm dia and uprooting roots ands tumps etc. from the seat of the embankment andcanal free from all vegetation including breaking clods not more than 10 mm cube, ramming, dressing and roughening the seat of the embankment with a lead upto 30M and lift upto 1.50 M, complete as directed . In ordinary soil |
| 19 | C.C work inproportion 1:3:6 infoundation /abutment / piers/wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing, dewatering with necessary timber shuttering, scaffolding etc. where necessary,complete as directed.(Shuttering,scaffolding cost will be paid separately). |
| 20 | Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. |
| 21 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.) (i) with 19 mm thick plyboard |
| 22 | RCC work inslab, abutment cap and above abutment, pier cap,pedestals,dirt walletc. inproportion 1:2:4 with hard broken stone aggregate of size 6mm to20 mm with proper reinforcement as per design including necessary curing, dewatering etc.complete as directed with necessary timber shuttering, scaffolding etc.where necessary, complete as directed. (Shuttering,scaffolding cost will be paid separately). |
| 23 | 12 mm cement plastering including clearing surface and curing, complete as directed. (1:3) |
| 24 | Construction of 2 cusec Brick lined water course |
| 25 | Earthwork in excavation in irrigation canal to the design section and grade by depositing the spoils in the form of embankment in 15 cm layers on both banks as necessary including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps etc. from the seat of the embankment and canal free from all vegetation including breaking clods not more than 10 mm cube, ramming, dressing and roughening the seat of the embankment with a lead upto 30 M and lift upto 1.50 M, complete as directed. (A) In ordinary Soil |
| 26 | River sand filling in plinth, canal bed, canal slopes, bases of structure, etc in layers not more than 150 mm thick including necessary carriage, watering etc, complete as directed as specified. |
| 27 | CC work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc. with hard broken stone aggregate of size 13 mm to 25 mm including curing, dewatering with timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately). |
| 28 | 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc, including racking out joints and curing etc, complete as directed.in proportion 1:3 |
| 29 | 12 mm cement plastering including clearing surface and curing, complete as directed.In proportion 1:3 |
| 30 | Construction of Supporting Pillar (For 9n nos) |
| 31 | Earth work in excavation of foundation of canal structures in all types of soil as per design and drawing dressing the foundation, shoring, etc. removing the surplus spoils by head load to a safe distance from the working place and depositing required spoils in uniform layers dressing, watering, breaking clods to not more than 10mm cube with compaction complete as directed at site (including bailing out stagnant water where necessary). |
| 32 | Soiling in foundation floor at all levels including filling interstices,ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing. |
| 33 | C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately). |
| 34 | R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately). |
| 35 | Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered). (C) Shuttering (Column) |
| 36 | Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. |
| 37 | 12 mm cement plastering including clearing surface and curing, complete as directed(ii) In proportion 1:4 |
| 38 | Construction of Intake Reservior |
| 39 | Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mentioned in the approved drawing and complete as directed and specified.(A) In ordinary soil |
| 40 | CC work in proportion 1:4:8 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately) |
| 41 | Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. |
| 42 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.)(i) With 19 mm thick plyboard |
| 43 | R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately). |
| 44 | 12 mm cement plastering including clearing surface and curing, complete as directed(ii) In proportion 1:4 |
| 45 | Construction of Division Box (for 2 nos) |
| 46 | Earthwork in excavation in foundation of canal structures in all types of soils as per design and drawing including dressing the foundation, shoring etc. removing the surplus spoils by head load to safe distance from the working place and depositing the required spoils in uniform layers, dressing, watering, breaking clods to not more than 10 mm cube with compensation, complete as directed at site. (Including bailing out stagnant rain water where necessary). (A) In all types of soil (except soil mixed with gravel and boulder)(i) For normal lead of 30 M and lift of 1.50 M |
| 47 | CC work in proportion 1:4:8 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately) |
| 48 | CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately). |
| 49 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.)(i) With 19 mm thick plyboard |
| 50 | 12 mm cement plastering including clearing surface and curing, complete as directed(ii) In proportion 1:4 |
| 51 | Construction of Cattle Crossing (for 3 nos) |
| 52 | Earthwork in excavation in foundation of canal structures in all types of soils as per design and drawing including dressing the foundation, shoring etc. removing the surplus spoils by head load to safe distance from the working place and depositing the required spoils in uniform layers, dressing, watering, breaking clods to not more than 10 mm cube with compensation, complete as directed at site. (Including bailing out stagnant rain water where necessary). (A) In all types of soil (except soil mixed with gravel and boulder)(i) For normal lead of 30 M and lift of 1.50 M |
| 53 | CC work in proportion 1:4:8 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately) |
| 54 | R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately). |
| 55 | Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. |
| 56 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.)(i) With 19 mm thick plyboard |
| 57 | 12 mm cement plastering including clearing surface and curing, complete as directed(ii) In proportion 1:4 |
| 58 | Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layers not exceeding 15 cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat of embankment and borrow pit area, breaking clods not more than 10 mm cube, ramming, ramming, watering, watering, dressing dressing and roughening roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M, complete as directed. (A) With ordinary Soil . |
| 59 | Construction of Outlet 0.15m dia (for 10 nos) |
| 60 | Earthwork in excavation in foundation of canal structures in all types of soils as per design and drawing including dressing the foundation, shoring etc. removing the surplus spoils by head load to safe distance from the working place and depositing the required spoils in uniform layers, dressing, watering, breaking clods to not more than 10 mm cube with compensation, complete as directed at site. (Including bailing out stagnant rain water where necessary). (A) In all types of soil (except soil mixed with gravel and boulder)(i) For normal lead of 30 M and lift of 1.50 M |
| 61 | CC work in proportion 1:4:8 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately) |
| 62 | CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately). |
| 63 | Supplying of Hume pipe from factory to work site with carriage and necessary collar etc. complete as directed.(0.15M dia, NP3). |
| 64 | Supplying of Coller from factory to work site with carriage and necessary collar etc. complete as directed.(0.15M dia, NP3). |
| 65 | Labour for fitting and fixing hume pipe in position with collars including joining the cement mortar in proportion 1:3 and curing, including carrying the same from godown to site and complete as directed. |
| 66 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.)(i) With 19 mm thick plyboard |
| 67 | 12 mm cement plastering including clearing surface and curing, complete as directed(ii) In proportion 1:4 |
| 68 | Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layers not exceeding 15 cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat of embankment and borrow pit area, breaking clods not more than 10 mm cube, ramming, ramming, watering, watering, dressing dressing and roughening roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M, complete as directed. (A) With ordinary Soil . |
| 69 | Cross drainage work- 0.60m dia (For 4 nos) |
| 70 | Earthwork in excavation in foundation of canal structures in all types of soils as per design and drawing including dressing the foundation, shoring etc. removing the surplus spoils by head load to safe distance from the working place and depositing the required spoils in uniform layers, dressing, watering, breaking clods to not more than 10 mm cube with compensation, complete as directed at site. (Including bailing out stagnant rain water where necessary). (A) In all types of soil (except soil mixed with gravel and boulder)(i) For normal lead of 30 M and lift of 1.50 M |
| 71 | CC work in proportion 1:4:8 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately) |
| 72 | CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc. with hard river shingles of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately). |
| 73 | Supplying of Hume pipe from factory to work site with carriage and necessary collar etc. complete as directed.(0.60M dia, NP2). |
| 74 | Supplying of Coller from factory to work site with carriage and necessary collar etc. complete as directed.(0.60M dia, NP2). |
| 75 | Labour for fitting and fixing hume pipe in position with collars including joining the cement mortar in proportion 1:3 and curing, including carrying the same from godown to site and complete as directed.(i) For 30 cm to 60 cm dia |
| 76 | Centering and shuttering including propping, nailing, bolting with earth oiling inside face etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to be taken on the face area timbered). (Abutment / Return Wall / Piers / Pedestal etc.)(i) With 19 mm thick plyboard |
| 77 | 12 mm cement plastering including clearing surface and curing, complete as directed(ii) In proportion 1:4 |
| 78 | Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layers not exceeding 15 cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat of embankment and borrow pit area, breaking clods not more than 10 mm cube, ramming, ramming, watering, watering, dressing dressing and roughening roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M, complete as directed. (A) With ordinary Soil . |
| 79 | Approach Road |
| 80 | Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed. |
| 81 | Collection and supply of sand and gravel (40% sand and 60% gravel) of size 13mm to 38mm from approved quarry including loading, unloading and stacking in measurable stacks at work site up to a height of 1.00m including payment of forest royality etc. |
| 82 | Labour charges for spreading hard river shingles / sand gravels to required thickness over approach subway etc. including ramming, dressing the seat before laying the materials lead upto 30.00 M and lift 1.50 M. Complete as directed. |
| 83 | Re-construction of PWD Road after laying of delivery pipes |
| 84 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :bituminous road |
| 85 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.28.1 All Kinds of soil |
| 86 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 87 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 88 | Supplying and stacking at site. 63 mm to 45 mm size stone aggregate |
| 89 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 90 | Surface dressing on new surface in two coats with bitumen of grade VG -10 of approved quality using 1.8 kg of bitumen per sqm with 1.5 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface for first coat and 1.1 kg. of bitumen per sqm with 1.00 cu. metre of stone chippings 11.2 mm nominal size per 100 sqm of road surface for second coat, including consolidation of each coat separately with road roller of 6 to 8 tonne capacity etc. complete |
| 91 | construction of Sign Board |
| 92 | Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed. |
| 93 | Construction of Pump House |
| 94 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All Kinds of soil |
| 95 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 96 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 97 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 98 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 99 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 100 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 101 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 102 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 103 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 104 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 105 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 106 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 107 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 108 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 109 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 110 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 111 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 112 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 113 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 114 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 115 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 116 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 117 | Construction of S.O Quarter- Building |
| 118 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 119 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.1 1:4 (1 cement : 4 coarse sand) |
| 120 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources) |
| 121 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level5.22.1 Mild steel and Medium Tensile steel bars |
| 122 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 123 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 124 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 125 | Brick work with common burnt clay machine moulded modular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 6.28.1 From ground level upto plinth level |
| 126 | Supplying and filling in plinth with sand under floors,icluiding watering, ramming, consolidating and dressing complete. |
| 127 | (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 128 | Lintels, beams, plith beams, girders, bressumers and cantilevers. |
| 129 | Coloumns, Pillars,Piers, Abutments, Posts and Struts. |
| 130 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 131 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 132 | 15 mm cement plaster on the rough side of single or half brick wall of mix 13.2.1 1:4 (1 cement: 4 fine sand) |
| 133 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 134 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm |
| 135 | Proviing and applying plaster of paris putty of 2 mm thickess over plasteres surface to prpare the surface even and smooth complete. |
| 136 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. |
| 137 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 138 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 139 | Float glass panes of nominal thickness 4 mm |
| 140 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :.250x10 mm |
| 141 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 142 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes |
| 143 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 144 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 145 | Precoated galvanised steel barge board (upto 300mm ) |
| 146 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 147 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 148 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) |
| 149 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 150 | Septik Tank |
| 151 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 152 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level5.22.1 Mild steel and Medium Tensile steel bars |
| 153 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 154 | (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for massconcrete |
| 155 | In Slab |
| 156 | In Beam, Lintel |
| 157 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) In Superstructure |
| 158 | Baffle wall |
| 159 | Brick work with common burnt clay machine moulded modular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 6.28.1 From ground level upto plinth level |
| 160 | SANITARY & WATER SUPPLY WORKS : |
| 161 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 162 | Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap |
| 163 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 164 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 165 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal dia Pipes |
| 166 | External Work40mm nominal dia pipes |
| 167 | External Work32 mm nominal dia Pipes |
| 168 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 169 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 170 | Providing and fixing soil, waste and vent pipes : 75 mm nominal dia Pipes |
| 171 | 100 mm nominal dia Pipes |
| 172 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 173 | Internal Electrification Works |
| 174 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 175 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with pianotype switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. For medium point upto 6.00m long |
| 176 | For long point upto 10.00m long |
| 177 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 178 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 179 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 180 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 181 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 182 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 183 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 184 | Mechanical partPUMPS, MOTORS, PIPES AND ACCESSORIES FOR SUCTION & DELIVERY, PRIMING SYSTEM |
| 185 | Centrifugal pump set with 60 / 70 LPS minimum discharge at 10.35 Mtrs Head, working efficiently at head range (7.62 – 13.71) Mtrs coupled with 20 HP induction motor. Pump, Motor, Starter should be of reputed brand and as per IS Specification.MOTOR : Conforming to IS : 325 - 19781. Make : MARATHON/ LUBI/ Kirloskar/ Crompton/ Havells2. Type / Model : Squirrel cage TEFC 3. HP : 20 HP4. RPM : 14505. Supply Voltage / Phase / Cycle : 415 V ± 10% 3 PH/ 50 Hz 6. Class of Motor Insulation : FPUMP :- Conforming to IS : 6595 Part – I1. Make : LUBI/ Kirloskar2. Type : Horizontal Axially Split Casing3. Model : LHC 125 -250/ UP-125/30 A4. Size ( Suction X Delivery ) : 150 mm x 125 mm5. Head Range :7.62 – 13.71 M6. Pump Input : 10.81 KW7. Efficiency at duty Point : 78 %STARTER SUITABLE TO RUN ABOVE PUMP SETS:1. Make : BCH/ Havells/ Equivalent2. Model : NASALLEM3. Type : FASD4. Relay Range : 13 – 21 ABASE FRAME : Best quality MS frame of required size and shape for complete pump set.COUPLING : Best quality coupling of required size suitable for the pump set |
| 186 | CI Foot Valve: Heavy Duty CI Foot Valve, Flange type, the holes of the flange should be drilled as per BSS No. 10, Part-1, Table-D. The materials of construction and all components of the Foot Valve should strictly conform to IS : 10805 - 1986 and having marked with manufacturer’s name and trade mark. Make: Kirloskar / Upadyaya / Zolato / Venus & Equivalent.ii) 150 mm dia |
| 187 | CIDF Reflex Valve: Heavy Duty CIDF Reflex Valve, swing check type, with by pass arrangement, horizontal operating. The holes of the flange to be as per BSS NO.-10, Part-I, Table D and the material, construction and all components should strictly conform to IS : 5312 (Part – I) - 2004 and having marked with manufacturer’s name and trade mark. Make: Kirloskar / Upadyaya / Zolato / Venus & Equivalent. iii) 125 mm dia |
| 188 | CIDF sluice valve: Heavy Duty CIDF sluice valve, inside screw, non raising, vertical spindle type with hand wheel operation, need for water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No.10, Part-I, Table-D. All materials, construction and components should strictly conform to IS : 14846 - 2000 and having marked with manufacturer’s name and trade mark Make: Kirloskar / Upadyaya / Zolato / Venus & Equivalent. iii) 125mm dia |
| 189 | 1 H.P Mono block pump set along with starter |
| 190 | Job ItemsInstallation of Centrifugal Pump set (Horizontal Split casing type, size: 150 mm(suction) x 125 mm dia. (delivery) of 60 LPS minimum discharge at 13.00 Mt head coupled with 3 ph, 415 V, 50 Hz, 1450 RPM squirrel cage induction motor of 20 HP complete set. The job includes necessary transportation of pump set to the site and installation of C.C. block foundation in proper position with accurate alignment by means of foundation nuts and bolts complete with all works. |
| 191 | Supply and installation of overhead tank alongwith stand:Fabrication and supply of M.S. tank of size 0.6m x 0.6m x 0.6m alongwith M.S. stand of 1.70m height comprising 4 Nos. columns fabricated from M.S. angle 1SA 5050 with 3 Nos. lateral bracing and frame fabricated from 1SA 4040 followed by erection of the same with necessary C.C. base foundation with necessary support and clamping including. |
| 192 | Cost of C.C. foundation block for overhead tank:The job consists of earthwork, soling in foundation, ramming cc work in proper proporation, work of ordinary timber planking, cement plastering etc. |
| 193 | Fabricated heavy duty G.I Pipe Confirming to IS 1239(Part-I)2004, with G.I Flange at both end (G.I Flange having 8 nos hole as per B.S.S Part-I table-D of size(for suction side)A. 150mm dia x 0.60 Mtr long |
| 194 | B.150mm dia x 0.90 Mtr long |
| 195 | C.150mm dia x 3.00 Mtr long |
| 196 | Fabricated M.S.D.F Pipe,5mm thick with 19mmm dia 12 nos hole in the flange of thickness 10mm for sizeA. 150mm dia x 0.30 Mtr long |
| 197 | B. 125mm dia x 0.60 Mtr long |
| 198 | C. 125mm dia x 0.90 Mtr long |
| 199 | D. 125mm dia x 3.00 Mtr long |
| 200 | Fabricated Heavy duty G.I bend confirming to IS-1239(part-I) 2004,with G.I Flange having 8 nos hole as per B.S.S -10 Part-I table-D of sizeA 12mm dia x45 |
| 201 | B 150mm dia x45 |
| 202 | Fitting, fixing and laying of G.I. Pipes with Accessories: Laying, fitting, fixing and connection of suction pipe line for each pump set with 150mm dia. G.I. pipes of different length, fabricated G.I. pipes with different length, fabricated bends, tapper including foot valve for suction side. Reflex valve, sluice valve for delivery side of each pump set with 125mm dia. G.I. pipes with different length, bends, fabricated G.I. pipes with different length as per drawing. The joints should be with the best quality pipe joining sets of required size comprises of 60mm thick black moulded rubber gasket, necessary nuts, bolts and washer. Every joint should be leak proof and should be completed in all respect from foot valve to the pump flange for suction side and from delivery flange is the water flow through at proper F.S.L for the delivery side. The pipes lines with accessories must be proper painting. |
| 203 | Providing, fitting , fixing and erection of pipe supports for each pipeline at on interval of 3.00 Mtr. (approx) made of M.S. channel (ISMC 75) 1.50 Mtr. height with angle bracing erected on CC block of size 0.45mX0.30mX0.60m below ground. |
| 204 | Starter Stand: Supply & Installation of MS Starter Stand made of MS Angle of size 50mmx50mmx5mm including of providence C.C Block Foundation for installation of starter stand along with the required cement concrete works etc. The work includes painting of the starter stand with 1(one) coat of red oxide metal primer to be followed by 2(Two) coats of anticorrosive smoke grey paint to be applied after air drying of each previous coat. |
| 205 | Installation of Earth Station including supply of Earth continuity conductor materials, erection, connection of Earth Station with G.I pipe of 40mm dia. x 2Mt long with reducing sockets, nuts & bolts etc as per I.E Rule, connecting the motor etc by 8 SWG G.I wire through perforated G.I pipe with 12mm dia. holes all over the body of G.I pipe of standard spacing pointed at bottom end. For earth continuity conductor required of salt, charcoal to be used in the earth station. |
| 206 | Installation, fitting, fixing of 1.0 HP mono block pump set (excluding cost of pump set), pipes and accessories for priming system at each point of a ELIS. The job consists of supply and fitting of items like flexible PVC pipe, GI pipe, GI Tee, GI Elbow, GI Nipple, GI Socket, Bronze valve, Foot valve, PVC insulated copper conductor etc and labour charges. |
| 207 | Miscellaneous Items : |
| 208 | Gland packing (12 mm dia) asbestos rope (B.Q.) |
| 209 | W.B. Grease (Best Quality) |
| 210 | M.S. Nuts & Bolts (Assorted Size) B.Q. |
| 211 | M.S. Washer (Assorted Size) B.Q. |
| 212 | Compressed leather (6 mm thick) |
| 213 | Halite sheet (1.5 mm to 4 mm thick) |
| 214 | Pipe jointing set complete with 6 mm thick moulded Rubber Gasket, M.S. Nuts & bolts with washer suitable for:- 125 mm dia flanged type |
| 215 | Pipe jointing set complete with 6 mm thick moulded Rubber Gasket, M.S. Nuts & bolts with washer suitable for:- 150 mm dia flanged type |
| 216 | Black moulded Rubber Gasket 6mm thick for 125 mm dia flanged type |
| 217 | Black moulded Rubber Gasket 6mm thick for 150 mm dia flanged type |
| 218 | G.I. Flange having 8 nos. of holes of sizes 125 mm dia as per B.S.S.-No-10 Part-I, table-D |
| 219 | G.I. Flange having 8 nos. of holes of sizes 150 mm dia as per B.S.S.-No-10 Part-I, table-D |
| 220 | Emery paper |
| 221 | Black/Red Electrical resistant rubber sheet, one side with chequred and other side is cloth finished tested up to 15 KVA as per ISS of ISI approved made size: 1.81M (L) x 0.90M (B) x 10mm (T) |
| 222 | Flexible wire of assorted size (Best quality) |
| 223 | Electrical partHT Line |
| 224 | ALIGNMENT OF HT LINEsurveying and finalising the suitable tapping point in existing nearby 11 kV line in consultation with APDCL and Departmental Officers, marking the alignment of the line considering Right of Way, Feasibility etc. as required and as directedA) For first 500 M |
| 225 | Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line. |
| 226 | Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed(C) POLE LENGTH 9.75 Metres(I) Refilling with Hard Soil(b) for less than 6 poles |
| 227 | Supplying and erection of GI Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed .Of Size 75mm × 40mm × 6mm × 2200 mm |
| 228 | Of Size 100mm × 50mm × 6mm × 2200 mm |
| 229 | 11 KV HT STAY SET (A) In Hard Soil with Boulder Rate per Set Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed . |
| 230 | CROSS BRACINGB Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of G I Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with G I Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed |
| 231 | INSULATORS11 kV PIN INSULATORPOLYMERICSupplying and Erection of 11 kV Polymeric Pin Insulator 5 kN on T Cross Arm/ Channel along with GI Pin, GI Nuts & Bolts including Drilling of Holes as directed |
| 232 | HARDWARE FITTINGSSupplying and Erection of Hardware Fittings (3u bolt) on existing MS / GI Channel Cross Arm with GI Nuts and Bolts for mounting 11 kV Disc Insulator 45 kN as directed |
| 233 | DISC INSULATOR(B) POLYMERICSupplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed |
| 234 | CONDUCTORSSupplying, Laying and Erection of Conductors of following size and specification for Overhead Line, binding to Insulators and Tensioning with Uniform Standard Sag including Jumpering connection as directedAAA CONDUCTORS AAA Raccoon Conductor - 7/3.81 mm |
| 235 | GI ANGLE CROSS ARMSupplying and erection of GI Angle Cross Arm on Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed of Size 50mm × 50mm × 6mm, 2200 mm long . |
| 236 | GUARDING AT ROAD CROSSING/ LINE CROSSING(B) Supplying and Erection of 8 SWG GI Guarding Wire on existing MS Angle Cross Arm with 5 Nos. of Longitudinal String and Cross Lacing 1.5 m at intervals of 50 cm including tensioning with proper sag as directed |
| 237 | 11 kV GANG OPERATED SWITCHSupplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed.B 400 Amps |
| 238 | 11 kV Drop Out(DO) Fuse UnitSupplying and Erection of 3-φ 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed.400 Amps |
| 239 | LIGHTNING ARRESTORSupplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed.9 kV, 10 kA with Polymer body |
| 240 | EARTH STATIONSUPPLY & ERECTION OF EARTH PIPE A. Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed |
| 241 | ERRECTION OF TRANSFORMERSupply including Erection of 4 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc,, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra )Capacity : 150 kVA, 11 kV/0.433 kV(Dyn), (as per CEA Guideline) (Cu-wound) with OLTC(A) Cost including Supply of Transformer |
| 242 | G I EARTH WIRESupply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed(A) with 6 SWG G I Wire |
| 243 | ANTI CLIMBING ARRANGEMENTSupply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed |
| 244 | LT FEEDER PANEL(G) Supplying including erection of powder coated LT Feeder Panel /Metering Panel for 63 kVA DTR of size (800mm × 1200mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 500 A FP MCCB, (50kA) making necessary connection through copper cable complete as directed.. |
| 245 | SUPPLY AND LAYING OF UNDER GROUND WITHOUT BRICK PROTECTION ( 3.5 Core Cable )F(i) Supply and Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 95 mm 2 × 3.5 Core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of trench of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5 cm + 7.5 cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed. |
| 246 | LAYING OF LT/HT POWER CABLES9.1 Supply and Laying in Air/ Open TrenchA Supply and Laying of Single Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/ pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed(A)(viii) Size of Cable : 95 Sq mm × 1 core(4 line) |
| 247 | SECURITY FENCING AROUND SUBSTATIONProviding Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed. |
| 248 | LTCT TRIVECTOR ELECTRONIC ENERGY METERErection & Commissioning LTCT Trivector electronic energy meter including making necessary payment to APDCL for CTs, meter security etc. as reqd and as directed. |
| 249 | TESTING & COMMISSIONING OF HT LINETesting and commissioning of the 11kV line including making payment for necessary Inspection Fee and obtaining charging approval from competent authority (Electrical Inspectorate) as directedupto 1 kM |
| 250 | DOCUMENTATIONLiaisoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till Commissioning of the HT Line/Substation, Preparation of all necessary documents like Agreement and Affidavit required for new Power Connection, obtaining No Objection Certificate from Forest Department where necessary complete all arrangement for charging the Installation as required and as directed |
| 251 | Load Security |
| 252 | L.T Control Panel |
| 253 | Main Panel Cabinet for 20 HP Pumpsets1.1.1(C) Main LT Panel Board Suitable for operation of 3 х 20 HP Pumpset Size :1600 mm(B)х 1200 mm(H)х 400 mm(D)Supplying, installation, testing & commissioning of indoor type floor mounted, cubicle type compartmental, dust and vermin proof (as per IP-54) main LT Control Panel Board of following capacity and of given size, made out of 16 SWG CR Sheet and 40mmх40mmх6mm angle having four nos. of legs 400 mm long at the bottom, with folded and welded construction having dismantling doors at the back, surface chemically treated and Siemen\"s grey powder coated, containing Al. strip busbar having minimum current density of 1.2 Amp/mm2 R-Y-B-N colour coded with heat shrinkable insulating sleeves containing all incoming and outgoing electrical accessories as specified, neatly installed and internally wired with best quality multi-strand, PVC insulated Single core unsheathed, HRFR copper wire (switch gears above 100Amp rating to be connected to busbar through Aluminium strip of suitable size) having cable incoming & outgoing provision at the bottom through gland plates complete including necessary excavation of trench and C C Work as directed.1.1.1(C) Main LT Panel Board Suitable for operation of 3 х 20 HP Pumpset Size :1600 mm(B)х 1200 mm(H)х 400 mm(D) |
| 254 | PIPE EARTH STATIONSupplying & Erection of Pipe Earth Station including supply of all materials with G I Pipe of following size perforated all over the body with 12 mm dia hole at standard spacing with necessary reducing socket, locking arrangement with hinge cover plate, funnel G I Nuts & Bolts etc. with necessary enclosure on the top including excavation and refilling as required and as directed.Earth Station with 50 mm dia × 4.5 Metre long G.I Pipe. |
| 255 | SUPPLY AND LAYING UNDER GROUND WITHOUT BRICK PROTECTION( 3 Core Cable)(A)35 Sq mm × 3 core(A)(i) Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed |
| 256 | LT CAPACITOR BANKSupplying fitting fixing of LT Power Capacitor 415 Volt AC 3 φ (SingleUnit) of following KVAR Rating and making connection with Busbar inthe existing Panel. The Capacitor is to be placed in existing Platform.6 kVAR Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail