| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) areanot exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast as required complete all as specified and asdirected. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) areaexceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast as required complete all as specified and asdirected. |
| 3 | Taking down steel rolling shutter of any description and area and removing from site complete all as specified and asdirected. |
| 4 | Supply and fixing factory made uPVC white colour casement (Open-able, double shutter glazed and wire guage) window/ventilator made of extruded profiles with wall thickness of 2.3mm (± 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 ± 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Including Hardware:[casement handle made of zinc alloyed (white powder coated), But Hinges of\"zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and including 5mm thick toughened glass and Wire cloth Stainless steel 304 Grade, natural finish, 0.63 mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 5 | Supply and fixing factory made uPVC white colour Three track three panels sliding window (area exceeding 1 Sqm and not exceeding 2 Sqm) with fly proof SS wire mesh (Two nos. glazed& one no. wire mesh panels), frame 90 x 42 mm & sash 31 x 57 mm both having wall thickness of 2.3 ± 0.2 mm and single/double glazing bead of appropriate dimension. Window comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality (as per approved sample), including 5mm thick toughened glass and Wire cloth Stainless steel 304 Grade, natural finish, 0.63 mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 6 | Note for uPVC Window/VentilatorNote :(i) The cost of glass, wire mesh, fasteners and all other connected accessories shall deemed to be included in the quoted unit rate. (ii) Net Opening will be measured for payment purpose. (iii) Cost for making good to cutting holes/dismantled portion during taking down old with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) uPVC frame, sash and mullion extruded profiles ± 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 7 | Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/Chowkhat (Single Rebated) of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 8 | Supply and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/ Chowkhat (Single Rebated) of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed.Note: (i) WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 9 | Supply and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/ Chowkhat (double Rebated) of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed.Note: (i) WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 10 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solidflush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020. |
| 11 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solidflush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020. |
| 12 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)glazed/gauge skelton door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with butt hinges with necessary full body threaded star headed counter sunk S.S screws including S&F wire cloth complete all as specified and as directed including supply and fixing following items:-(a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020.(e) Stainless Steel (304 Grade) (natural finish) wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm, fixing as per manufacture |
| 13 | Note for WPC/uPVC Frame/window/shutter(i) Test certificate of Manufacturer to be provided by contractor.(ii) Embossing with Barcode of Manufacturer engraved over each door Frame & shutter is mandatory. (iii) Cost for making good to cutting holes/dismantled portion during taking down old with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv)The cost of all other connected accessories, fixing material shall deemed to be included in the quoted unit rate. |
| 14 | Supply & fixing factory made steel window box type using ERW hollow \"P\" section and double angle frame, with side hung shutters (glazed shutter and fly proof shutter) complete including grill of 8mm sq bar fixed horizontally @ 100 mm C/C and fittings like hinges, tower bolt, stop leg, handle and including Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, fixing of lugs in PCC etc., width, height and design of window as directed by GE complete all as specified and as directed. |
| 15 | Supply & fixing factory made steel ventilator (fixed type glazed ventilator) box type using ERW hollow \"P\" section, fixing of lugs in PCC etc., width, height and design of ventilator as directed by GE complete all as specified and as directed. |
| 16 | Note for SteelWindow/Grills/VentsNote :- (i) Glass and painting shall be measured and paid separately under respective item of Sch (ii) The weight of steel window/ventilator with mongery and grill shall be physically ascertained through a board of officers convened by CWE and payment shall be made only after the actual weight at site. (iii) The weight shall be measured before fixing the glass.(iv) Cost for making good to cutting holes/dismantled portion during taking down old and fixing new hold fast /lugs with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 17 | Material and labour for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed.Note :- (i) Glass & wire mesh shall be measured and paid separately under respective item of Sch |
| 18 | Material and labour for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges, pivots, Aluminium mongery/fittings and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and as directed.Note :- (i) Glass and ACP sheet shall be measured and paid separately under respective item of Sch |
| 19 | Note for Aluminium Frame/Door/Window/Grill(i) The weight of Aluminium section/Frame or complete door/wndow with mongery and aluminium grill shall be physically ascertained through a board of officers convened by CWE and payment shall be made only after the actual weight at site.(ii) The weight shall be measured before fixing the glass/wiremesh. (iii) Cost for making good to cutting holes/dismantled portion during taking down old and fixing new hold fast with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 20 | Material and labour for steel rolling shutters push pull or manual type made out of 1.25 MM thick lath, with and including ball bearings, gear operated type with bevel gear box and crank handle as specified including top cover anchoring rod hasp and staple, guide channel, suitable shutter lock Safety lever lock mild steel with 4 levers with double key, hold fast,erected in position as directed including two coats of synthetic enamel paint over a coat of red oxide primer both sides on exposed surfaces and making good the disturbed surface as per existing complete all as specified and as directed. |
| 21 | Supply & fixing 4mm thick sheet glass ordinary quality in squares / retangular in any size of each pane and fixed complete all as specified and as directed. |
| 22 | Supply & fixing 4mm thick figured glass pin head type in squares / retangular not exceeding 0.5sqm in each pane and fixed complete all as specified and as directed. |
| 23 | Supply & fixing 5mm thick sheet glass ordinary quality in squares / retangular in any size of each pane as in aluminium doors, window, partitions and similar work including cutting to shape complete all as specified and as directed. |
| 24 | Supply & fixing aluminium composite panel sheet 4mm thick (ACP sheet), skin thickness 0.5mm, durable PVDF (Polyvinylidene Fluoride) coating for weather resistance, PE (Polyethylene) core, with Fire Retardant (FR) or A2 grade cores, and compliance with standards like IS 17682, complete all as specified and as directed. |
| 25 | Supply & fixing Hydraulic Door Closer Pelmet Arm & PVD (Physical vapor deposition) Cover Door Closer (overhead door closers),With a wide 130-degree opening and an adjustable closing speed, Load Capacity 85kg, door opening 800 to 1200mm, Commercial-grade aluminium alloy, Weather-proof and rust-resistant complete all as specified and as directed. |
| 26 | Supply & fixing Floor door stopper of stainless steell (304 grade) body and tongue, anodised, with hard drawn steel spring, complete all as specified and as directed. |
| 27 | Hacking out old broken glass (any thickness, size, quality or description) from metal or any frame including punching or drilling out old glazing pins/beadings and Supply & fixing new 4mm thick sheet glass ordinary quality in squares / retangular not exceeding 0.5sqm in each pane and fixed in any type of doors/windows/ventilators with and including fixing material as per existing or as directed complete all as specified and as directed. |
| 28 | Supply and fixing stainless steel pipe 25mm bore (as a curtain rod), wall thickness of pipe not less than 1mm and grade SS 202, fixed in position with fixing accessories like Brackets, finial and side holder of same manufacturer including taking down old existing curtain rod any type complete all as specified and as directed.Note : (i) Brackets, finial and side holder shall be measured and paid separately for supply only but the cost for fixing the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.(ii) Cost for screws, rawl plugs as required for fixing shall also shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 29 | Supply only stainless steel 202 grade brackets for fixing of 25mm bore curtain rods complete all as specified. |
| 30 | Supply only stainless steel 202 grade finials for fixing of 25mm bore curtain rods complete all as specified. |
| 31 | Supply only stainless steel 202 grade side holder for fixing of 25mm bore curtain rods complete all as specified. |
| 32 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 33 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position and includingdisposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 34 | Dismantling of floor hearth or wall tilling/terrazzo including cement mortar bedding layer but not backing including prepared the surface clean to receive further treatment including removing rubbish material from building and thrown in low lying empty area at any distance upto 2.5 KM as direccted from the site complete all as specified and as directed. |
| 35 | Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Material and labour for 15mm thick Wearproof topping metallic floor hardener mixed with cement thoroughly to an even colour in dry state in the proportion recommended by the manufacturer.This mixture shall be mixed with crushed granite/ basalt/trap (6mm and down) in the proportion 1:2 by volume (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and as directed.Note : (i) Metalic hardnershall be measured and paid for separately under appropriate item of BOQ as supplying only. |
| 37 | Supply only Metallic floor hardener of approved size and quality complete all as specified and as directed. |
| 38 | Supply and fixing of heavy-duty Linoleum flooring sheets of thickness 3.2–3.3 mm, in any approved colour, manufactured from up to 98% natural and sustainable raw materials, comprising solidified linseed oil, pine resin, cork dust, wood flour and mineral fillers, backed with hessian/canvas fabric, conforming to EN ISO 24011 and EN ISO 10874 or equivalent standards, The material shall be fire retardant, having reaction to fire Class Bfl-s1 as per EN 13501-1 and slip resistance minimum R9 as per DIN 51130 / EN 13893. The flooring shall be laid over prepared floor surface using approved manufacturer-recommended adhesive, including stretching, cutting, jointing, rolling, sealing of joints, finishing, and all incidental works, complete in all respects as specified and as directed. |
| 39 | Material and labour for 15 mm thick bedding layer (screed bed for tiles) in cement mortar (1:4) in grey cement including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg, and finish the surface even and fair/rough to receive the tile complete all as specified and as directed.Note :- (i) Liquid Water Proof Compound shall be measured and paid separately as supply only under respective item of BOQ.(ii) The labour element of mixing of Liquid Water Proof Compound is included in this item. |
| 40 | Material and labour for 10 mm thick bedding layer (screed bed for tiles) in cement mortar (1:4) in grey cement including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg, and finish the surface even and fair/rough to receive the tile complete all as specified and as directed.Note :- (i) Liquid Water Proof Compound shall be measured and paid separately as supply only under respective item of BOQ.(ii) The labour element of mixing of Liquid Water Proof Compound is included in this item. |
| 41 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 42 | Material and labour for providing glazed ceramic coloured tiles (approved any shade in any pattern of light & dark/highlighters tiles etc as approved) area of each tile exceeding 0.06 Sqm and not exceeding 0.18Sqm having thickness 7-8 mm thick, Premium quality having water absorption should be between 10% to 20%, straight edge, stain free, glossy finish, laid as on vertical surfaces such as in skirting/dado etc,, set and jointed using type-2 adhesive (thin bed) confirming to IS-15477:2019, fixed the tile using spacer 3mm or as per manufacturer’s instruction and joint filled with epoxy grout matching with the colour of tiles including necessary cutting as per site requirement, complete all as specified and as directed.Note: Screed bed shall be measured and paid separately under respective item of BOQ |
| 43 | Material and labour for providing Double charge vitrified coloured tiles (approved light shade), area of each tile exceeding 0.42 Sqm but not exceeding 1.00 Sqm, having thickness not less than 8mm, premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floors and skirting, set and jointed using type-2 adhesive (thin bed) confirming to IS-15477:2019, fixed the tile using spacer 3mm or as per manufacturer’s instruction and joint filled with epoxy grout matching with the colour of tiles including necessary cutting as per site requirement, complete all as specified and as directed.Note: Screed bed shall be measured and paid separately under respective item of BOQ |
| 44 | Material and labour for providing Anti-skid vitrified tiles, matte finish, coloured tiles (approved shade), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, having thickness not less than 7mm, premium quality having water absorption should be between 3% to 6%, straight edge, stain free, glossy finish, laid as in floors, set and jointed using type-2 adhesive (thin bed) confirming to IS-15477:2019, fixed the tile using spacer 3mm or as per manufacturer’s instruction and joint filled with epoxy grout matching with the colour of tiles including necessary cutting as per site requirement, complete all as specified and as directed.Note: Screed bed shall be measured and paid separately under respective item of BOQ |
| 45 | Material and labour 18-20mm thick Granite (approved shade like dark black, mahroom etc ), machine cut, duly factory grinding and polishing (table rubbed and polished) as in cooking platform, in steps, jambs, pillars, window-cills, for counter sunkor table top wash basin, vanities counter, as in skirting and like or where directed,set &jointed in and including neat cement slurry @ 3.00 Kg/ Per Sqm and pointing in white cement mixing with pigment to match with shade of granite, including cutting as required including cleaning and extra polishing if required complete all as specified and as directed.Note : (i) Single piece should be used in steps/cills/jambs/shelves/ equal to width of slab, including accomodate the hole for gas pipe/mixer valve (where required) and chamfering/rounding the outer edges, nothing extra shall be paid on this account(ii) Screed bed shall be measured and paid separately under respective item of BOQ |
| 46 | Material and labour for machine cut18-20mm thick (minimum), Kota stone slab (size of slab not less than 550x500mm for flooring including 75mm wide white marble strips (border) all-around of room/verandah, set &jointed in and including neat cement slurry @ 3.00 Kg/ Per Sqm and pointing in white cement mixing with pigment to match with shade of slab, including rubbing /grinding andpolishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed.Note : (i)Screed bed as required shall be measured and paid separately under respective item of BOQ |
| 47 | Material and labour for machine cut 15-18mm thick, Kota stone slab as in skirting, dado and on pillar, set &jointed in and including neat cement slurry @ 3.00 Kg/ Per Sqm and pointing in white cement mixing with pigment to match with shade of slab, including machine cutting to make it square or rectangular as per site complete all as specified and as directed.Note : (i)Screed bed if required shall be measured and paid separately under respective item of BOQ |
| 48 | Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in foundation filling and mass concrete, in post hole, bed block, as in surface channels& similar work etc including form work complete all as specified and as directed. |
| 49 | Material and labour for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, hard standing, path etc, laid in suitable panels not exceeding 3.00 m length finished even and smooth without using extra cement, 10mm Joints filledwithbituminous sealing compound of grade ‘A’/bitumen mastic filler/sealant complete all as specified and as directed. |
| 50 | Material and labour for hard core of broken stone or boulders of gauge exceeding 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 51 | Material and labour for 100mm thickcement concrete ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 52 | Material and labour for 75mm thickcement concrete ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 53 | Material and labour for PCC ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 54 | Material and labour for 25mm thick PCC in cement mortar (1:2:4) type B0 using 12.5mm graded stone aggregate as in sub base, the surface finished fair/rough complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material and labour for 100mm thick cement concrete 1:2:4, Type-B-1 , using 20 mm graded stone aggregates as in sub base of pavement, hardstanding and finishing surfaces of concrete topping even and fair (without using extra cement) complete all as specified and as directed. |
| 56 | Material & Labour for 40 mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4), type B-0, including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg,complete all as specified and as directed.NOTE: WPC will be measured and paid for separately under respective item of Schedule \"A\" |
| 57 | Material and labour for Cement concrete work as in pavement/hard-standing over prepare sub base, flexural strength 40 kg/per square centimetre in field using 20mm nominal size graded crushed stone aggregate, any thickness of concrete, with provision of panels size as directedand surface finished even & smooth including necessary form work complete all as specified and as directed.Note:- (i) Contraction joints, dummy joints shall be measured and paid separately under respective item. |
| 58 | Supply and fixing Aluminium dividing strips, 90mm wide, 1.5mm thick, inserted in position, conform to design complete all as specified and as directed. |
| 59 | Supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block/ interlocking tile of M-35 grade, prepolished & preglazed, with approved colour, design & pattern (laid in required colour & pattern as directed) as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 60 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in surface channels, benching/coping of manholes/drains, coping, mud stops, packing sides/around of interlocking tiles, bed block, thrust block, for embedded posts & similar work etc including weatherings, slightly rounded or chamfered angles and including necessary form work as required etc. complete all as specified and as directed. |
| 61 | Supply and laying at or near ground level factory made kerb stone of M-20 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 62 | Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar ncluding removing from the site complete all as specified and as directed. |
| 63 | Demolition/taking out any type roof treatment, any thickness,like mud phuska/brick coba, APP membraneetc from roofs,including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof and surrounding/parapit wall etc, including cleaning of surface of loose dust, and dirt and cement slurry etc. by means of wire brush, dust removing brush and scraper etc. and washing with water and preparing the roof surface to receive further treatmentincluding removing rubbish material from building and thrown in low lying empty area at any distance upto 5 KM as direccted complete all as specified and as directed.Note :- Only Plan area of roof will be measured for payment.Cost for removing/cutting uprooting grass, vegetations etc from area for surrounding/parapit wall etc shall deemed to be included in unit rate quoted, nothing extra shall be admissible on this account. |
| 64 | Material and labour for repair of surface with GP-2 (General Purpose Grout) or repair mortar upto 15mm thick as per site condition/ manufacturer’s instruction and including cracks shall be repaired with cement admixed with polymer as per manufacturer’s instructions complete all as specified and as directed.Make of material : Sika /Fosroc / Pidilite / Asian Paints / MBTCC (BASF) / I-CanNano or Techno commercial equivalent make approved by CWE in writing from make mentioned in Appx \"B\"/ E-in-C\"s Br approved list. |
| 65 | M and L for cleaning surface of any loose dust, dirt or slurry by means of wire brush, dust removing brush etc. after preparation of surface treated with PU epoxy primer to seal the pores and enhance the adhesive of the coating, after primer applying single component waterproofing liquid membrane based on pure, polyurethane resin cold applied with spray, applied PU membrane shall be UV resistant with SRI (Sun Reflective Index) of 98 with an elongation of 650% +50 and tensile strength not less than 2Mpa. No leakage upto five bars of water pressure. Shore hardness >70 shall be 2.00mm (overall) DFT (Dry film thickness), In two or more layers (each layer minimum 750 micron) or as per manufacturer’s instructions so as to achieve thickness not less than 2.00mm DFT complete all as specified and as directed.Make of material : Sika /Fosroc / Pidilite / Asian Paints / MBTCC (BASF) / I-CanNano or Techno commercial equivalent make approved by CWE in writing from make mentioned in Appx \"B\"/ E-in-C\"s Br approved list.Note: - (i) Payment will be made after providing warranty certificate for 10 years from the company. (ii)The thickness of the PU membrane shall be checked with cut and seal method and the third-party test to be carried out from NABL approved lab. The sample size for check should be 50x50mm randomly at any location and kept in record. |
| 66 | Carefully chipping, removing existing loose/ damaged concrete with plaster from Columns/Beams, Ceiling, Chajja, Fascia, Fins, Drops and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operateddiamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower and including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed. |
| 67 | Cleaning all existing reinforcement bars in Columns/Beams, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, complete all as specified and as directed.Note :- Mode of measurement: per sqm of breaking area of concrete only.Make: Sika- Rustoff 100/Fosroc- Reebaklens RR/ Pidilite Dr Fixit Rust Remover / Asian Paints Apcorep Rust Rem / MBTCC / I-CanNano or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 68 | Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min0.4 kg/Sqm approx) in Columns/Beams, Ceiling, Chajja, Fascia, Fins, Drops and similar items, The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and as directed.Note :- Mode of measurement: per sqm of application area of concrete.Make: Sika- Friazinc R/Fosroc- Nitozinc Primer/ Pidilite Dr Fixit Zinc Rich Primer / Asian Paints Apcorep Rust coat RB / MBTCC/ I-CanNano or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 69 | Apply SBRbasedbondingagenttotheentireconcretesurfacepriortobuildingupofconcretewith Polymer modified mortar or any other treatment , (consumptionQty as permanufacturer’s instructionsbut min 0.4 kg/Sqm approx) including cleaning the surface to remove dirt, dust or anyotherimpuritiesonthesurface of Columns/Beams, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and as directed.Make: Sika - SikaDur 32 LP / Fosroc - Nitobond SBR (EP)/ Pidilite Dr Fixit Super Latex (EP) / MBTCC/ I-CanNano or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 70 | Material and Labour forRebuilding the section of structural damaged RCC/PCC elements of column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength>= 50 N/Sqmm (28 days) according to ASTM C 109, flexural strength >= 5N/Sqmm (7 days) according to ASTM C-293-79 complete all as specified and as directed. Make: Sika / Fosroc /Pidilite Dr Fixit / MBTCC (BASF) / I-CanNano or Techno commercial equivalent make approved by CWE in writing from make mentioned in Appx \"B\"/ E-in-C\"s Br approved list.Note:- Mode of measurement : per sqm of breaking area of concrete only. |
| 71 | Material and Labour forRebuilding the section of structural damaged RCC/PCC elements of column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed repair to spalling concrete to its original size and shape in additional layers of 10 mm uniform thickness for subsequent layers by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength>= 50 N/Sqmm (28 days) according to ASTM C 109, flexural strength >= 5N/Sqmm (7 days) according to ASTM C-293-79 complete all as specified and as directed. Make: Sika / Fosroc /Pidilite Dr Fixit / MBTCC (BASF) / I-CanNano or Techno commercial equivalent make approved by CWE in writing from make mentioned in Appx \"B\"/ E-in-C\"s Br approved list. |
| 72 | Supply & fixing of 15mm nominal dia CPVC pipes SDR 11 conform to requirement of IS 15778 including all fittings Plain/brass threaded CPVC SDR 11 (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 73 | Supply & fixing of 20mm nominal dia CPVC pipes SDR 11 conform to requirement of IS 15778 including all fittings Plain/brass threaded CPVC SDR 11 (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 74 | NOTE FOR CPVC/GI PIPES : (i)Pipes inside the buildings shall be fixed concealed and outside the buildings shall be fixed on the surface along wall with clamps/brackets keeping 100mm away from wall. (ii) Bracket, clamp, nut bolt, fastener, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (iii) Where concealed pipe laying in new location (other than taking out old pipe location) then cutting chases in wall shall be measured & paid separately under relevant item of BOQ. |
| 75 | Material and labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing, cutting not exc 10 cm girth in brick wall and making good, complete all as specified and as directed. |
| 76 | Supply & fixing Rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996, any colour white colour or as directed, of capacity 1000 litres, hoisted and fixed in position including making inlet and out let connection complete all as specified and as directed. |
| 77 | Supply and fixing CPVC globe or gate valve (ISI marked), heavy duty, plain both ends suitable for 15mm bore pipes and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 78 | Supply and fixing CPVC globe or gate valve (ISI marked), heavy duty, plain both ends suitable for 20mm bore pipes and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 79 | Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed. |
| 80 | Supply and fixing Bib taps,CP,long body with wall flange screwed for 15mm bore brass ferrule and fixed in position complete all as specified and as directed.Make : Jaquar Cat No. VGP-81037 or equivalent from Cera (Valentina Single Lever Series) or equivalent from Hindware (Fluid Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 81 | Supply and fixing pillar tap, CP, Long Neck, screwed for 15mm bore brass ferrule/PVC connection and fixed in position complete all as specified and as directed.Make : Jaquar Cat No. VGP-81001 or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 82 | Supply and fixing Angular Stop Cock with wall flange, CP, screwed down, screwed for 15mm bore brass ferrule or for union and fixed in position complete all as specified and as directed.Make : JaquarCat No. VGP-81053 or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 83 | Supply and fixing Stop valves, fancy type, CP with long shank and cup ( concealed type ), exposed part kit with wall flange and regular body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete all as specified and as directed.Make : Jaquar(Cat No. VGP-81083K (Vintage Prime) & ALD 083) or equivalent from Cera (Valentina Single Lever Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 84 | Supply and fixing Chromium plated overhead shower 100mm dia with shower arm of 450mm long 20mm dia round shape with 90º bend for wall mounted shower with flange of same make and incl all necessary accessories as recommended by manufacturer for fixing complete in all respect all as specified.Make : Jaquar (Shower-OHS-1989, Shower Arm-SHA-479L450) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 85 | Supply & fixing single towel rail 600mm long stainless steel, complete all as specified and as directed.Make : Jaquar Cat No. CAN-GBP1111S M or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 86 | Supply and fixing soap dish, stainless steel of suitable size to accommodate soap any type, complete all as specified and as directed. |
| 87 | Supply and fixing any size as directed bevelled edge mirror of selected quality 6-6.3mm thick glass mounted on PVC sheet, rounding off edges of glass, and shall be fixed at wall with CP studs, complete all as specified and as directed. |
| 88 | Supply and fixing PVC connection 15 mm size of length 450 mm with PTMT nuts of approved qualitycomplete all as specified and as directed. |
| 89 | Supply and fixing vitreous china premium/1st quality wash basin (under counter), white/ivory/off white, size 410x310x220mm including S&F all accessories as recommended by manufacturer like packing, union andincl 32mm brass CP waste coupling and waste pipe complete fixed in position in all respect as per manufacturer\"s instructions complete all as specified and as directed.Note: Slab shall be measured and paid separately |
| 90 | Supply & fixingvitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed. |
| 91 | Supply & fixing vitreous China squatting pan \"Orissa\" pattern white of size 580mmx440mm white with integral foot rests, excluding flushing cistern, flush pipe above floor but including uPVC \"P\" or \"S\" trap setsuitable bore and including setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete complete all as specified and as directed. |
| 92 | Supply and fixing 10 litres capacityPVCvalveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handleincluding brackets and 32mm dia PVC flush pipe complete all as specified and as directed. |
| 93 | Supply & fixing 110mm bore uPVC pipesgrade \"B\"single socketedin any length with rubber ring joints, fixed along walls keeping 100mm away from wall,joints fixed with pipe joint lubricant including uPVC fittings/ Fixture like bend/tees of any radious/junction (double T/Y, socket)equal or unequal (fittings with or without access door as per requirements and as directed), reducer any type, vent cowls etc., complete all as specified and as directed.Note:- (i) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (ii) The testing for leakage of pipe shall be done before completion as directed by AGE. (iii) The separate pipes shall be provided for Sewage and drain system in all floors, No combination should be done. |
| 94 | Supply & fixing 75mm bore uPVC pipesgrade \"B\"single socketedin any length with rubber ring joints, fixed along walls keeping 100mm away from wall,joints fixed with pipe joint lubricant including uPVC fittings/ Fixture like bend/tees of any radious/junction (double T/socket)equal or unequal (fittings with or without access door as per requirements and as directed), reducer any type, vent cowls etc., complete all as specified and as directed.Note:- (i) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (ii) The testing for leakage of pipe shall be done before completion as directed by AGE. (iii) The separate pipes shall be provided for Sewage and drain system in all floors, No combination should be done. |
| 95 | Supply & fixing 50mm bore uPVC pipesgrade \"B\"single socketedin any length with rubber ring joints, fixed along walls keeping 100mm away from wall or fixed as a spout/over flow pipe of tank,joints fixed with pipe joint lubricant including uPVC fittings/ Fixture like bend/tees, vent cowls etc., complete all as specified and as directed.Note:- (i) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (ii) The testing for leakage of pipe shall be done before completion as directed by AGE. (iii) The separate pipes shall be provided for Sewage and drain system in all floors, No combination should be done. |
| 96 | Supply & fixing Bracket, Stack clamp, nut bolt, fastner, slotted channel etc suitable for uPVC pipe of any dia 110/75/50mm and for CPVC pipe of any dia all made out of Galvanised iron material with hot dip zinc aluminium flake coated, size and shape of bracket and clamp as directed so that pipe keeping 100mm away from wall complete all as specified and as directed.Note :- The weight of Bracket, Stack clamp, nut bolt, fastner, slotted channel etc shall be physically ascertained through a board of officers convened by CWE and payment shall be made only after the actual weight at site. |
| 97 | Supply & fixing uPVCfloor trap 110mm bore long neck with stainless steel grating including jointing with pipe joint lubricant, including PCC work complete all as specified and as directed. |
| 98 | Supply & fixing uPVCfloor trap 75mm bore long neck with stainless steel grating including jointing with pipe joint lubricant, including PCC work complete all as specified and as directed. |
| 99 | Supply & fixing PVC (SWR) gully trap 125 X 110 mm, type b, setting and jointing with solvent cementcomplete all as specified and as directed. |
| 100 | Taking down cement plaster from brickwalls/soffits of roof projections & chajjas /ceilings etc. including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 101 | Material and labour for plastering 15mm thick with ready mix cement plaster material on external surface of Brick walls/chajja/fins or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 102 | Material and labour for plastering 10mm thick with ready mix cement plaster material on internal surface of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 103 | Material and labour for plastering 5mm thick with ready mix cement plaster material on concrete surfaces of ceiling, finished fair and evencomplete all as specified and as directed. |
| 104 | Material and labour for plastering 10mm thick with ready mix cement plaster material on concrete surfaces of ceiling, finished fair and evencomplete all as specified and as directed. |
| 105 | Dismantling of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description, stacking serviceable brick for re use if directed and balance removing rubbish from the site complete all as specified and as directed. |
| 106 | Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 107 | Material and labour for brick work with Fly Ash bricks (old size ), straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. |
| 108 | Material and labour for brick workin half brick thick wall with sub class \"B\" burnt clay bricks (old size ), straight or curved on plan to any ra`dius built in cement mortar (1:4) complete all as specified and as directed. |
| 109 | Material and labour for brick work using old serviceable bricks obtained from dismantled item shall be reused after cleaning old cement mortar, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 110 | Demolition of cement concrete reinforced of any description such as roof slab, slab, beam, staircase, landing chajja, kitchen chimney, OHT staging, fins, shelves, etc, including reinforcement cut as required to facilitate demolition and prepare the surface to casting/jointing newincluding removing rubbish material from building and thrown in low lying empty area at any distance upto 5Km from the site as directed complete all as specified and as directed. |
| 111 | Material and labour for Flush pointing to brick wall as in cement motar (1:4), complete all as specified and as directed. |
| 112 | Material and labour for reinforced cement concrete M-25 (Nominal mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in cup board shelves and the like complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ. |
| 113 | Material and labour for reinforced cement concrete M-25 (Nominal mix) using 20mm graded stone aggregate as in chajjas, fascias, fins and like complete all as specified and as directed by Engineer-in-Charge.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ. |
| 114 | Material & Labour for Precast RCC (1:2:4) type B1 using 20 mm graded stone aggregate as in manhole cover, set in CM (1:4) including necessary form work complete all as specified and as directed (Reinforcement and MS handle shall be measured and paid separately under appropriate item of this Sch). |
| 115 | Material and labour for reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels any span and the like complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ. |
| 116 | Material and labour for mild steel TMT bars,grade Fe 500D/550D, 10mm dia & over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 117 | Material and labour for mild steel TMT bars, grade Fe 500D/550D, 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose) |
| 118 | Form work toflat sides and soffits offloor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas, fascias, fins etc and similar worksrough finished flat surfaces complete all as specified and as directed. |
| 119 | Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed. |
| 120 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and removing from site complete all as specified and asdirected by Engineer-in- charge. |
| 121 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings and removing from site complete all as specified and asdirected |
| 122 | Dismantling iron or mild steel work of any description like framed truss (structural work), framed work in shed and similar work etc complete all as specified and as directed. |
| 123 | Dismantling steel work of any description like cooler stand, grills, grating, walk ways, railings, frame work of water tanks, framed work of motor pump, doors, gates and similar work etc but excluding framed truss etc. complete all as specified and as directed. |
| 124 | Dismantling of boarding any description (wooden/PVC/gypsum board etc), fixed in any position, wall, ceiling boards, cup board, cabinet, false ceiling etc (particle, fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 125 | Dismantling of unframed timber scantlings 40 sq. cm and over in section, in any position and removing from site complete all as specified and asdirected |
| 126 | Dismantling of Gl frame work (snap grid framed work) any type and removing from site complete all as specified and asdirected |
| 127 | S&F Gl frame work (snap grid framed work, Size of grid 605 x 605mm) for ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including hangers 6 mm dia. GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long at any height and position complete all as specified and as directed. |
| 128 | S&F 6-7mm thick PVC board both side PVC profile sheet, suitable for roof ceiling snap grid framed work, shape, colour and design as approved by GE complete all as specified and as directed. |
| 129 | S&F 12mm thick non asbestos fibre cement designer building boards, suitable for roof ceiling snap grid framed work, fixed or laid/ inserted to GI framework with screws complete all as specified and as directed. |
| 130 | Material and labour for pre-painted hot-dip aluminium–zinc alloy metallic coated corrugated steel sheets (profiled) of any approved pattern, 0.50 mm thick, conforming to IS 15965:2012, coating class AZ150, durability class 3, atmospheric classification category C3, in an approved colour, having a minimum yield strength of 550 MPa. The sheets shall be fixed as roof covering using self-drilling screws with washers, including all end and side laps. The item includes all necessary scaffolding and safety measures at any floor level, complete, all as specified and as directed. |
| 131 | Material and labour for pre-painted hot-dip aluminium–zinc alloy metallic coated plain steel sheets (profiled), 0.50 mm thick, conforming to IS 15965:2012, coating class AZ150, durability class 3, atmospheric classification category C3, in an approved colour, having a minimum yield strength of 550 MPa. The sheets shall be fixed as ridge covering over corrugated roofing sheets to be cut, bent and fixed using self-drilling screws with washers, including all necessary laps, overlaps. The item includes all necessary scaffolding and safety measures at any floor level, complete, all as specified and as directed. |
| 132 | Supply and fixing Fibre Reinforced Plastic (FRP) plain sheet green clour 2.5 to 3mm thick, Smooth/Matte finish , having high mechanical strength and tensile strength, excellent fire and heat resistance, any size as per site requirement, fixed with and including suitable size rivets or MS nut bolt in any position such as view cutter, wall cladding, decorative fencing etc;,complete all as specified and as directed.Note :- Iron Frame Structure shall be measured and paid separately under appropriate item of BOQ |
| 133 | Material and labour for mild steel tubular poles/post,framed/truss, purlins, rafter work etc made by using hollow square/rectangular/round pipe, Grade St-240, ERW or induction butt welded tubes conforming to the latest relevant Indian Standards (IS), such as IS 1239 (Part 1) or IS 4923 for structural use, including fabrication, assembly, installation, and finishing,including special shaped washers, bending and welding etc, complete all as specified and as directed. |
| 134 | Material and labour for mild steel tubular framed work, as view cutter fence frame etc made by using hollow square/rectangular/round pipe, Grade St-240, ERW or induction butt welded tubes conforming to the latest relevant Indian Standards (IS), such as IS 1239 (Part 1) or IS 4923 for structural use, including fabrication, assembly, installation, and finishing,bending and welding etc, complete all as specified and as directed. |
| 135 | Material and labour for MS work heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, Plates square cut or notched (ordinary and counter sunk) etc.forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W(Gde-E-250) quality-B complete all as specified and as directed. |
| 136 | Supply and fixing Mild steel bolts exceeding 12mm dia and not exceeding 20mm dia of neck, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed. |
| 137 | Material and labour for mild steel work using FI as wind ties for roof including securing bolts conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 138 | Material and labour for mild steel Framed work such as in doors or gates, grills, guard bars, ladder, railing, cloth drying provision, gratings, cooler stand, frame work of water tanks and similar work etc. made by using rolled mild steel Joist, channel, angle, or tee sections, or other section with gusset plates, rails, braces, round bars etc., complete, cut to shape, bending and welding, riveting etc, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including fabrication as directed, including hold fast, locking arrangement, sliding door bolt, stopper etc conforming to Fe-410-W (Gde E-250) quality A, complete all as specified and as directed. |
| 139 | Material and labourfor Mild steel, 1.60mm thick plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as requiredcomplete all as specified and as directed. |
| 140 | Material and labour for preparation ofnew steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st quality) of approved tint/colour over a coat of red oxide primer with using paint brush complete all as specified and as directed. |
| 141 | Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete all as specified and as directed. |
| 142 | Material and labour for complete removal of existing treatment of any type/description (any layer) from external/internal wall/ceiling surfaces, soffits/chajja/roof projection surfaces etc., by scraping steel patti or Mechanical sander/grinder machine having suction vaccum Bag (Smart periodical methodology), complete all as specified and as directed. |
| 143 | Material and labour for preparation of new plastered surfaces, surface after complete removal, applying acrylic putty on internal surfaces of walls/ceiling/soffits etc (thickness vary from 1.5 to 2 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using readymade putty, including sanding with wall sander after filling the putty in first coat/second coat to make surface smooth and ready for receiving interior painting complete all as specified and as directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.Make of acrylic Putty: - Berger / Asian / Nerolac |
| 144 | Material and labour for applying 02 coats of interior acrylic emulsion paint of approved tint/shade (Company Depot Tinted) @ 12 sq.m/litre/2 coats to wall surfaces (new or old prepared internal surface after complete removal and applying putty) over and including a coat of interior primer @ 11 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller brush complete all as specified and as directed.Note ;- Complete removal and putty shall be measured and paid separately under respective item of BOQ.Brand and Make of interior acrylic emulsion paint: - Easy Clean Matt of Berger / Apcolite Advanced of Asian / Impression Ultra Fresh of NerolacBrand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 145 | Material and labour for applying 02 coats of exterior acrylic emulsion paint of approved tint/shade (CompanyDepot Tinted) @ 6 sq.m/litre/2 coats to external walls / Soffits of Chajjas / Roof Projections / Cantilevers / Balcony etc. (new or old prepared external surface after complete removal) over and including a coat of exterior primer @ 11 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using airless spray gun complete all as specified and as directed.Note ;- Complete removal shall be measured and paid separately under respective item of BOQ.Brand and Make of exterior acrylic emulsion paint: - Weather Anti Dust of Berger / Apex Ultima of Asian / Excel Mica Marble of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 146 | Material and labour for applying 02 coats of interior acrylic emulsion paint of white shade (Company Depot Tinted) @ 7.50 sq.m/litre/2 coats to ceiling surfaces (new or old prepared internal surface after complete removal and applying putty) over and including a coat of interior primer @ 10.50 sq.m/litre/1 coat (primer shall be same make asacrylic emulsion paint), paint and primer applying by using paint roller brush complete all as specified and as directed.Note ;- Complete removal and putty shall be measured and paid separately under respective item of BOQ.Brand and Make of interior acrylic emulsion paint: - Bison Acrylic Emulsion of Berger / Tractor Emulsion of Asian / Beaty Smooth of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 147 | Material and labour for Preparation of existing internal verticle treated surfaces by remove / scraping down allloose treatment etc with using broom / paint brush / sand papering or by any other mean including sanding with wall sander (as per requirement) to make surface smooth including applyingputty where required for filling to nail holes/light hair cracks etc., after preparing the surface applying 01 coat of interior acrylic emulsion paint of approved tint/shade as per existing (Company Depot Tinted) @ 20 sq.m/litre/per coat to wall surfaces over and including a coat of interior primer @ 13 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller brush complete all as specified and as directed.Brand and Make of interior acrylic emulsion paint: - Easy Clean Matt of Berger / Apcolite Advanced of Asian / Impression Ultra Fresh of NerolacBrand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 148 | Material and labour for Preparation of existing treated surfaces by remove / scraping down allloose treatment etc with using broom / paint brush / sand papering or by any other mean including applyingwall putty where required for filling to nail holes/light hair cracks etc., after preparing the surface applying 01 coat of exterior acrylic emulsion paint of approved tint/shade as per existing (Company Depot Tinted) @ 11.50 sq.m/litre/per coat to external walls / Soffits of Chajjas / Roof Projections / Cantilevers / Balcony etc. over and including a coat of exterior primer @ 15 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using airless spray gun complete all as specified and as directed.Brand and Make of exterior acrylic emulsion paint: - Weather Coat Glow of Berger / Apex Weatherproof of Asian / Excel of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 149 | Material and labour for Preparation of existing internal ceiling treated surfaces by remove / scraping down allloose treatment etc with using broom / paint brush / sand papering or by any other mean including sanding with wall sander (as per requirement) to make surface smooth including applyingputty where required for filling to nail holes/light hair cracks etc., after preparing the surface applying 01 coat of interior acrylic emulsion paint of approved tint/shade as per existing (Company Depot Tinted) @ 18 sq.m/litre/per coat to ceiling surfaces over and including a coat of interior primer @ 13 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller brush complete all as specified and as directed.Brand and Make of interior acrylic emulsion paint: - Bison Acrylic Emulsion of Berger / Tractor Emulsion of Asian / Beaty Smooth of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 150 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed |
| 151 | Surface dressing not exceeding 15cm deep in soft/ loose soilincluding cutting of grass, roots, bushes if any and removing from site all grass, roots and extra soil if any complete all as specified and as directed. |
| 152 | Excavation in trenches (Manual), not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations of shafts, wells, cess pits, manholes, pipe line, cable trenches etc., not exceeding 10 Sqm on plan and getting out in any type of soft including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 153 | Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces complete all as specified and as directed. |
| 154 | Labour for earth filling, spreading and levelling in layers n exc. 25 cm thick (each layer) consolidating the surface with Durmat/hand roller, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge including levelling, well ramming including watering as required and consolidation complete all as specified and as directed. (a) Earth obtained from excavation shall be used and nothing extra on account of lead shall be paid. |
| 155 | Material and labour for supplying approved earth from outside MOD land (irrespective of any lead) and stacking where directed for forming embankments and compacting the earth complete all as specified and as directed.Note :- (i) Only consolidated thickness of earth will be measured and paid.(ii) Qty of earthwork shall be decided by BOO convened by CWE at the time of execution of work (where stacking) as per taking initial and final level/taking measurement after compacting the earth and after standard deduction minimum 15%. (iii) Cost for rough excavation, loading, unloading, transportation, taking levels etc shall deemed to be included in the unit rate quoted , nothing extra shall be paid on this account. |
| 156 | Forming Embankments incl raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering, ramming/rolling and finishing to required size, shape and slope,consolidating the surface with Durmat/hand roller or any other means, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge complete all as specified and as directed. |
| 157 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 158 | Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 159 | Supply & fixing 110mm bore uPVC pipes grade \"B\"single socketedin any length, fixed as weep holes in toe wall, complete all as specified and as directed. |
| 160 | Dismantling/demolition of complete existing black top surface in any area exceeding 400 Sqm and depth exceeding 40mm but not exceeding 60mm (average depth 50mm) as per requirement in single pass with suitable cold milling machine fitted with loading convey or for loading the milled material directly on the trucks and stacking where directed complete all as specified and as directed.Note :- Stacked/milled material removing from site to any lead at contractor site (out side MOD land) after completion of road work or as directed by GE being contractor property (as per credit Sch) cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 161 | Material & labour for Preparing existing surfaces of WMM by brushing with wire brushes for removing caked mud etc. sweeping with brooms & finally fanning the cleaned surfaces with air pressure to remove allloose dirt etc. & after preparing applying evenly a prime coat of cationic bitumen emulsion SS1 conforming to IS: 8887 @ 7-10 kg/10 Sqm on surfaces of WMM as specified in Table 500-3 of MORTH specifications for road and bridge works 2013, using mechanical sprayer, complete all as specified and as directed. |
| 162 | Material & labour for providing and laying Dense bituminous macadam of compacted thickness in any range from 50mm to 75mm as per site requirement, using paving bitumen binder of grade VG-30 @ and binder content of 4.5 % by weight of total mix with mixing of aggregates and VG-30 bitumen in electronic operated 100-120 TPH batch type Hot mix plant, transporting the hot mix from HMP to work site by tippers and laying with hydrostatic sensor paver, rolle d and compacted to required gradient and camber with smooth wheeled, vibratory and tandem roller, complete all as per clause 505 MORTH (5th revision) specification and as directed.Note :- (i) The contractor shall quote the rate against item considering 4.5 % VG-30 bitumen content, Job mix formula as per clause No. 505.3.3 of MORTH ( 5th revision) for BM shall be worked out from any Govt Lab/Govt Engg college/CTL for obtaining optimum binder content (OBC) by the contractor and same shall be submit for approval of Accepting Officer through GE before execution. The cost thereof shall be deemed to be included in quoted unit rate. Any variation in binder content on minus side shall be adjusted @ 50/kg of binder and NO adjustment shall be made on plus side.(ii) The BM shall be covered with top layer/wearing course within a maximum of 48 hours. If there is to be any delay by the contractor, course shall be covered by seal coat to the requirement of clause 512 of MORTH (5th revision) before opening to the traffic. The seal coat in such cases shall be considered incidental to the work and shall not be paid for separately.(iii) The contractor shall intimate the planned date of incorporation of mix in advance to GE. Premix will be approved in writing by Rep of Accepting Officer at plant site before incorpoation of the same in the work.(iv) Paver shall not be compulsory in case of patch work using BM.(v)Payment shall be made after conducting bitumen extraction test after every laying every 500 units and cost is deemed to be included in the quoted rates. For any variation in bitumen contents the re-testing to be got done by contractor at without any extra cost.(vi) Repair to pot holes shall be carried out as directed by Engineer-in-charge under this item and not measured separately, cost is deemed to be included in the quoted rates. |
| 163 | Material & labour for Preparing of existing black top and DBM surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms & finally fanning the cleaned surfaces with air pressure to remove allloose dirt etc.& after preparing applying evenly a tack coat of cationic bitumen emulsion (RS-1) conforming to IS: 8887 @ 3 to 3.5 kg/10 sqm on DBM/bituminous surfaces as specified in Table 500-5 of MORTH specifications for road and bridge works 2013, using mechanical sprayer, complete all as specified and as directed. |
| 164 | Material & labour for laying Premix bituminous concrete 30mm consolidated thickness with 5.4% paving bitumen binder of grade VG-30, content by weight of total mix and crushed aggregates of grading 2 with mixing of aggregates and VG-30 bitumen in electronic operated 100-120 TPH batch type Hot mix plant, transporting the hot mix from HMP to work site by tippers and laying with hydrostatic sensor paver, rolled and compacted to required gradient and camber with smooth wheeled, vibratory and tandem roller, complete all as per clause 507 MORTH (5th revision) specification and as directed.Note :- (i) The contractor shall quote the rate against item considering 5.4% VG-30 bitumen content, Job mix formula as per clause No. 505.3.3 of MORTH ( 5th revision) for BC shall be worked out from any Govt Lab/Govt Engg college/CTL for obtaining optimum binder content (OBC) by the contractor and same shall be submit for approval of Accepting Officer through GE before execution. The cost thereof shall be deemed to be included in quoted unit rate. Any variation in binder content on minus side shall be adjusted @ Rs 50/kg of binder and NO adjustment shall be made on plus side.(ii) Cost of filler i.e. cement (OPC) is deemed to be included in quoted unit rate.(iii) After spreading of mix as as per clause 507.4.7 MORTH (5th revision) entire surface during the operation shall be rolled with road roller 8-10 tonne (smooth wheeled) followed with vibratory road roller of 8-10 tonne static weight , followed by finished rolling 6 to 8 tonne smooth wheel tendom roller as per clause No 507.4.8 MORTH (5th revision) and cost of the same is deemed to be included in quoted rates.(iv) The contractor shall intimate the planned date of incorporation of mix in advance to GE. Premix will be approved in writing by Rep of Accepting Officer at plant site before incorpoation of the same in the work.(v)Payment shall be made after conducting bitumen extraction test after every laying every 500 units and cost is deemed to be included in the quoted rates. For any variation in bitumen contents the re-testing to be got done by contractor at without any extra cost.(vi) Top of road surface shall be broomed on next day after completion of rolling and cost of the same is deemed to be included in quoted rates. |
| 165 | Material and labour for preparing bituminous new surfaces of road and marking thermo plastic reflective paint 2mm thick as in centre lines, side lines, stop lines, dashes, arrows etc. and the like (in any colour as directed like white, golden, yellow, orange black etc.) on road surface to be carried out mechanically with hot application of material (painting material @ 5kg/Sqm and glass beads @ 250gm/Sqm conforming to MORTH clause No 803-4) complete all as specified and as directed. |
| 166 | Supply and fixing two way (dual direction) reflective road stud ABS body confirming to IRC 67-1977 having capacity 40 tonne (cat eye) of size 100mmx 100mm x 18.5 mm,with amber/red/yellow reflective panels and fixing on road surface by applying approximately 100 gm Epoxy mixture and placing the cat eye without applying exessive pressure and fixed with zinc plated steel nail of size 8mm dia 120mm long at the centre of cat eye complete all as specified and as directed.Note :- Make shall be approved by Accepting Officer before placement of order |
| 167 | Supply and fixing convex mirror of 1000 mm dia made from long life poly carbonate with strong impact resistant and shatter proof fitted with a sun shield or protective hood of colour as approved by GE, provided with 75mm dia mild steel pipe (suitable length as directed) duly painted with synthetic enamel paint of approved colour over a coat of red oxide primer, including embedding in PCC (1:2:4, type B1) block of size 450x450x600mmincluding necessary earthwork complete all as specified and as directed.Note :- Make shall be approved by Accepting Officer before placement of order |
| 168 | Supply and laying DWCPE (SN8) for non-pressure underground drainage and Sewerage drain pipe 150mm nominal dia, Type B, confirming to 16098 (Part 2):2013 (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) including all accessories/fittings/jointing ring, jointing and testing, pipe laid in trenches directly on compacted earth, complete all as specified and as directed. |
| 169 | Taking down carefully existing point wiring any type (light/fan/sockets/bell/power point) complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including rusted/broken concealed conduit, junction and sunken boxes etccomplete all as specified and as directed. |
| 170 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green etc colour wires as per colour coding i.e for phase, netural, earth wire etc) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincludingmedium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and 1.6-1.63mm thick sheet) including inner and outer plate, cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall (as required and to making proper for fixing new pipe, disturbed cutting during taking down old pipe) and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. (ii) Where ever it is not feasible to cable drawn through existing PVC conduit in roof slab (for ceiling fan point only) due to blocked, casing capping or pipe shall be provided on surface of RCC including fixing arrangement without any extra cost, cost for the same shall deemed to be included in the quoted unit rate. |
| 171 | All as per above Srl item No. 170 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 172 | Material and labour for concealed Point wiring for one socket out let 5/6 Amps point controlled by one switch (on independent board with independent circuit using red, black and green etc colour wires as per colour coding i.e for phase, netural, earth wire etc) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincluding medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and 1.6-1.63mm thick sheet) including inner and outer plates, cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket etc, including cutting chases in wall (as required and to making proper for fixing new pipe, disturbed cutting during taking down old pipe) and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. |
| 173 | Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch/AC starter switch (on independent board with independent circuit using red, black and green etc colour wires as per colour coding i.e for phase, netural, earth wire etc) complete with 4 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincludingmedium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size,with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and 1.6-1.63mm thick sheet) including inner and outer plates, cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket etc, including cutting chases in wall (as required and to making proper for fixing new pipe, disturbed cutting during taking down old pipe) and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket, AC starter switch shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. |
| 174 | Taking down carefully existing point wiring any type (light/fan/sockets/bell/power point etc) complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including rusted/broken surface conduit/casing capping, junction and sunken boxes etc complete all as specified and as directed. |
| 175 | Material and labour for surface Point wiring (open surface of metal /brick wall/ceiling /along MS pipe etc) for one light point/fan point controlled by one switch (using red, black and green etc colour wires as per colour coding i.e for phase, netural, earth wire etc) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincluding medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 25 mm nominal size,with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and 1.6-1.63mm thick sheet) including inner and outer plates (cover plate white colour, any module as per requirements suitable for fixing the modular switches/ socket / regulator etc, including making good disturbed surfaces of walls/ceiling/floors etc. as per existing complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. (ii) PVC conduit and junction box shall be provided on open surface of metal /brick wall/ceiling /along MS pipe / under false ceiling etc and sunken terminal box concealed in wall or on surface flush fixed, all fixed with clips/clip clamps/PVC clamp /MS clamps /nut bolt /screws as directed or as per site requirement. The rate of these elements shall be deemed to be included in the unit rate quoted nothing shall be paid extra on this account. |
| 176 | All as per above Srl item No. 175 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 177 | Material and labour for surface Point wiring (open surface of metal /brick wall/ceiling /along MS pipe etc) for one socket out let 5/6 Amps point controlled by one switch (on independent board with independent circuit using red, black and green etc colour wires as per colour coding i.e for phase, netural, earth wire etc) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincluding medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size,with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and 1.6-1.63mm thick sheet) including inner and outer plates (cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket etc, including making good disturbed surfaces of walls/ceiling/floors etc. as per existing complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. (ii) PVC conduit and junction box shall be provided on open surface of metal /brick wall/ceiling /along MS pipe / under false ceiling etc and sunken terminal box concealed in wall or on surface flush fixed, all fixed with clips/clip clamps/PVC clamp /MS clamps /nut bolt /screws as directed or as per site requirement. The rate of these elements shall be deemed to be included in the unit rate quoted nothing shall be paid extra on this account. |
| 178 | Material and labour for surface Point wiring (open surface of metal /brick wall/ceiling /along MS pipe etc) for one socket out let 15/16 Amps point controlled by one switch (on independent board with independent circuit using red, black and green etc colour wires as per colour coding i.e for phase, netural, earth wire etc) complete with 4 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 4Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincluding medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size,with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and 1.6-1.63mm thick sheet) including inner and outer plates (cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket etc, including making good disturbed surfaces of walls/ceiling/floors etc. as per existing complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. (ii) PVC conduit and junction box shall be provided on open surface of metal /brick wall/ceiling /along MS pipe / under false ceiling etc and sunken terminal box concealed in wall or on surface flush fixed, all fixed with clips/clip clamps/PVC clamp /MS clamps /nut bolt /screws as directed or as per site requirement. The rate of these elements shall be deemed to be included in the unit rate quoted nothing shall be paid extra on this account. |
| 179 | Supply only modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed. |
| 180 | Supply only modular switch 16Amps, single pole, one way (1 module) complete all as specified and as directed. |
| 181 | Supply only modular Socket outlet multipurpose type 3 pin, 6 Amp, flush type (2 module) complete all as specified and as directed. |
| 182 | Supply only modular Socket outlet multipurpose type 3 pin, 16 Amp, flush type (2 module) complete all as specified and as directed. |
| 183 | Supply and fixing modular stepped type (1-4/5), electronic Fan regulator, 100-120 watt,250 volts, (2 module) suitable for other than BLDC fan complete all as specified and as directed. |
| 184 | Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, topline series, 240 volts, 5/6 Amp, complete all as specified and as directed. |
| 185 | Supply and fixing lamp holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 6Amps, complete all as specified and as directed. |
| 186 | Supply and fixing LED retrofit lamp, minimum 3 star rated 9/10W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications(a) Lumen system efficacy of lamp should be minimum 90 Lumen per watt.(b) Input Voltage range : 140 to 270 volts(c) Temp operating range : Minus 10°C to Plus 45°C(d) Power factor : Minimum 0.95(e) CRI: Morethan80 |
| 187 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 4 Way, 415V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 188 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way, 240V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 189 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way, 240V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 190 | Supply and fixing (concealed in wall or as directed) single pole and neutral, modular typeenclosure with a two pin and earth plug and socket, shall be of IP-54 protection class, complete with one single pole MCB of capacity 25 Amps, 240 volts, AC supply including taking down unserviceable old any type complete all as specified and as directed. |
| 191 | Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB/panel complete all as specified and as directed. |
| 192 | Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 to 63 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB/panel complete all as specified and as directed. |
| 193 | Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB complete all as specified and as directed. |
| 194 | Taking down existing LED tubelight, bed side lamp, ceiling light, panel light, bulk head light etc of any size complete all as specified and as directed. |
| 195 | Taking down existing LED out door security/street light fitting with GI bracket & clamps/Flood light including clamps of any size complete all as specified and as directed. |
| 196 | Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20/22Watt, appx 4 feet long, housing environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K(l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 197 | Supply and fixingLED light fitting 1 x 8/10Watt, appx 2 feet long LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95(e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap.(h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV.(l) CCT : Minimum 6000K(m) CRI : Minimum 80(n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 198 | Supply and fixing recessed type LED sensor based ceiling light fitting with wide light window for maximised glare free output, suitable for ceiling cutout 595x595mm modular grid/POP ceiling finishes complete fitting with driver and high brightness LED 34/35/36 Watt flat panel of size 600x600mm, including electric connection with using suitable flexible copper conductor cable from ceiling rose to light fitting, complete fitting and all accessories with following specifications and all as directed:-(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt.(b) Input Voltage range : 140 to 270 volts(c) Temp operating range : Minus 10°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Max10%.(f) IP rating : IP20.(g) CCT : 6500K(h) CRI : Morethan 80 (j) CRCA pre coated housing.(k) LED Driver of the make as of the luminaire.(l) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 3 kV.(n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 199 | Supply and fixing energy efficient LED wide angle flood light fittings of 150 W capacity with driver, Epoxy powder coated pressure die cast aluminium alloy housing and front cover clear toughned glass, including electric connection with suitable copper cable and including fixing arrangement with suitable nut bolts or any hanging hook etc, complete fitting and all accessories with following specifications and all as directed by Engr-in-Charge :-(a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: More than 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) |
| 200 | Supply and fixing energy efficient LED sensor based security light fitting of 45 W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5 Sqmm, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket along wall including painting to bracket, MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) (q) with integrated day/night sensors |
| 201 | Taking down carefully existing sub main wiring any run any size including rusted/broken concealed conduit, junction boxes etcand making good disturbed surface of walls/floors etc complete all as specified and as directed. |
| 202 | Material and labour for concealed sub main wiring (Three run i.e. 1 x phase and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 6 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 25mm dia (medium quality ISI marked), on independent circuit from panel/DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, complete all as specified and as directed.Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 203 | Disconnectingelectric connection and taking down carefully ceiling fan, exhaust fan, Geyser complete with accessories and deposited to E/M store yard complete all as specified and as directed. |
| 204 | Supply and hanging /fixing ceiling fan 1200 mm sweep color white AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding, single phase, 26-30W, Temperature rise 40 degree maximum with remote and remote holder (remote holder fixed on wall where directed), 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed.Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 205 | Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in opening in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed.Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 206 | Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body of capacity 25 litre with 2kw heating element, BEE approved 5 Star rating, 230 V, single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as having indicating light, safety valve, thermostat, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable and making connections with and including 15 amp top plug, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.(b) Serial Number of geyserissued by Engr-In-Charge and GE Office name shall also be written on geyser with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 207 | Material and labour for Cutting openings, through brick walls built in cement mortar at ground/first/second floor for exhaust fan 250/300/450mm sweep including making good with cement mortar (1:4) complete all as specified and directed. |
| 208 | Material and labour for Earthing complete with galvanised Galvanized steel pipe electrode, 40mm nominal bore, medium grade, 10 metres length buried directly and preferably vertically in ground with top edge not less than 1.25 metres below normal ground level, connected with earthing lead of 4mm dia galvanized earth wire by means of GI bolts/nuts/washers and protected by 15mm bore GI light grade pipe from earth pipe electrode to test point upto 7.5mtr including all as shown in electrical plate No. 2 ofSSR 2009 (Part-I). Earth GI pipe shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, including taking out/dismantling old unserviceable earthing system any type complete all as specified and as directed.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto 7.5 mtr from top of earth electrode shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 209 | Taking out old unserviceable LT XLPE/PVC cable of any size from trenches/wall/roof/road/pipe/pole including taking out oflayer of protection cover any type and removingfrom the site complete all as specified and as directed by Engineer-in-Charge.(Excavation, earth work, shall be measured and paid separately under appropriate item of BOQ). |
| 210 | Supply and laying XLPE LT Cable of size 16 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed. Note :- (i) Excavation, earth work, cutting of road/boring under road and protection pipe shall be measured & paid separately under appropriate item of this Schedule/BOQ.) |
| 211 | Supply and laying XLPE LT Cable of size 16 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed. Note :- (i) Excavation, earth work, cutting of road/boring under road and protection pipe shall be measured & paid separately under appropriate item of this Schedule/BOQ.) |
| 212 | Supply and laying XLPE LT Cable of size 25 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed. Note :- (i) Excavation, earth work, cutting of road/boring under road and protection pipe shall be measured & paid separately under appropriate item of this Schedule/BOQ.) |
| 213 | Supply and laying double wall corrugated pipe (DWC) non metalic, Resistance to compression -type 450, resistance to impact -normal, resistance to bending - pliable , resistance to external influence- ingress protection IP67, resistance against corrosion - without protection, resistance to flame propagation-Non flame propagation, Nominal outside diameter 50mm, minimum inside diameter 37mm confirming to IS 16205 (Part-24) -2017 complete all as specified and as directed. |
| 214 | Material and labour for boring of holes (trenchless horizontel hole) under road pavement, hard standing or any other situation by using trenchless boring machine/mechanically or by manual manpower suitable for for accommodate/inserting pipe upto 100mm bore in the drilled holes, including excavation, returning filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed.Note ; (i)Only length of the road/hard standing/Pavement will be measured for payment and cost for excavation, returning filling and making good at both side of bore shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.(ii) Pipe shall be measured and paid separately) |
| 215 | Supply and fixing GI tubing light grade of size 40 mm bore, ISI marked, fixed along steel poles/along PCC pole / along walls for cable protection including fittings like elbow, tee, socket, clamp with nut bolts etc) complete all as specified and as directed. |
| 216 | Taking down carefully existing surface type Flame proof Point wiring any type (light/exhaust fan point, any no of point controled by one switch) including rusted/broken conduit complete with all accessories junction box, Flexible conduit, inspection elbow, MCB/Switch etccomplete all as specified and as directed. |
| 217 | Material and labour for surface type Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 2.5 Sqmm(nominal cross section area)FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including flame proof rigid stove enamelled black ERW conduit suitable nominal size as required at site dia but not less than 25 mm nominal size, with all flame proof fittings and accessories i.e. flame proof joint, pipe bend, union, reducer, nipple, pipe hook, Screws, GI saddles, clamps, connectors etc, for light points including making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed.Note :- (i) One light point circuit of 03 lights controled by one MCB or Switch (ii) FLP junction box, Flexible conduit, inspection elbow and MCB/Switch shall be measured and paid separately under appropriate item of BOQ). |
| 218 | Material and labour for surface type Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 2.5 Sqmm(nominal cross section area)FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including flame proof rigid stove enamelled black ERW conduit suitable nominal size as required at site dia but not less than 25 mm nominal size, with all flame proof fittings and accessories i.e. flame proof joint, pipe bend, union, reducer, nipple, pipe hook, Screws, GI saddles, clamps, connectors etc, for light points including making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed.Note :- (i) One light point circuit of 04 lights controled by one MCB or Switch (ii) FLP junction box, Flexible conduit, inspection elbow and MCB/Switch shall be measured and paid separately under appropriate item of BOQ). |
| 219 | Material and labour for surface type Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 2.5 Sqmm(nominal cross section area)FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including flame proof rigid stove enamelled black ERW conduit suitable nominal size as required at site dia but not less than 25 mm nominal size, with all flame proof fittings and accessories i.e. flame proof joint, pipe bend, union, reducer, nipple, pipe hook, Screws, GI saddles, clamps, connectors etc, for light points including making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed.Note :- (i) One light point circuit of 05 lights controled by one MCB or Switch (ii) FLP junction box, Flexible conduit, inspection elbow and MCB/Switch shall be measured and paid separately under appropriate item of BOQ). |
| 220 | Supply and fixing ON/OFFSwitch flame proof rotary type with termination box in LM6, 16A, double pole 250V complete all as specified and as directed. |
| 221 | Supply and fixing Flameproof junction box LM6 protection, 4 way including FLP plug as required and accessories suitable for ERW pipe as per existing size in wiring complete all as specified and as directed |
| 222 | Supply and fixing Flameproof flexible metalic hose conduit pipe of size 20mm x 300mm long, heavy duty complete all as specified and as directed. |
| 223 | Supply and fixing Flameproof inspection elbow protection suitable for ERW pipe as per existing size in wiring complete all as specified and as directed |
| 224 | Supply and fixing in replacement CMRI certified flameproof 15 Watt LED bulk head luminaire recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2, die cast aluminium housing with heat resistant toughened glass/dome glass, external reflector, pre coated electronic type luminaire with inbuilt electronic driver, internally pre-wired, complete with all other accessories andincluding making electric connection connecting with twin core twisted flexible copper conductor cable and connector block, tobe fixed flush to wall surface complete all as specified and as directed. |
| 225 | Supply and fixing in replacement CMRI certified flameproof 40 Watt LED bulk head luminaire recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2, die cast aluminium housing with heat resistant toughened glass/dome glass, external reflector, pre coated electronic type luminaire with inbuilt electronic driver, internally pre-wired, complete with all other accessories andincluding making electric connection connecting with twin core twisted flexible copper conductor cable and connector block, tobe fixed flush to wall surface complete all as specified and as directed. |
| 226 | Supply and fixing in replacementCMRI certified flame proof DB die cast aluminium alloy (LM-6) Gas group of IIA, IIB and IIC, SPN 8 way, 240 Volts, operated externally spring type knob complete with cable entry to suitable incomming/out going cable with cable glands suitable for hazardous area and confirming to IS-2147/62, neoprene gasket, pre-wired, DB tobe fixed flush to wall surface, including flame proof MCB as under complete all as specified and as directed. (a) MCB single pole & neutral 32 Amps, 10 KA rupturing capacity, curve \"B\" - 01 No (Incoming)(b) MCB single pole 6 Amps, 10 KA, curve \"B\"- 06 Nos (Outgoing) |
| 227 | Supply and fixing Earth continuity conductor or main earthing lead 4mm dia galvanised iron wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed. |
| 228 | Taking down carefully existing Aluminium strip of any size from roof surface/along wall surface as earth grid and down conductor of lightening protection (from any height of building and in any position) including fixing accessories like base insulator, saddles, clamps, fixing screws, nut bolts etc. complete all as specified and as directed. |
| 229 | Labour only for re-fixing Aluminium strip of any size (old serviceable strip shall be reused obtained from taking down items) but with and including new ceramic/porcelain vitreous insulator (at not more than 100cm c/c) for base of suitable size and saddles and fixing screws, nut bolts with washer etc. for fixing the strip on roof surface/along wall surface as earth grid and down conductor of lightening protection system (above ground upto any height of building and in any position) complete all as specified and as directed. |
| 230 | Taking down carefully existing copper strip of any size from roof surface/along wall surface as earth grid and down conductor of lightening protection (from any height of building and in any position) including fixing accessories like base insulator, saddles, clamps, fixing screws, nut bolts etc. complete all as specified and as directed. |
| 231 | Labour only for re-fixing copper strip of any size (old serviceable strip shall be reused obtained from taking down items) but with and including new ceramic/porcelain vitreous insulator (at not more than 100cm c/c) for base of suitable size and saddles and fixing screws, nut bolts with washer etc. for fixing the strip on roof surface/along wall surface as earth grid and down conductor of lightening protection system (above ground upto any height of building and in any position) complete all as specified and as directed. |
| 232 | Supply and fixing Aluminium strip 25 x 3 mmwith and including ceramic/porcelain vitreous insulator (at not more than 100cm c/c) for base of suitable size and saddles and fixing screws, nut bolts with washer etc. for fixing the strip on roof surface/along wall surface as earth grid and down conductor of lightening protection system (above ground upto any height of building and in any position) complete all as specified and as directed. |
| 233 | Supply and fixing copper strip 20 x 3.15 mmwith and including ceramic/porcelain vitreous insulator (at not more than 100cm c/c) for base of suitable size and saddles and fixing screws, nut bolts with washer etc. for fixing the strip on roof surface/along wall surface as earth grid and down conductor of lightening protection system (above ground upto any height of building and in any position) complete all as specified and as directed. |
| 234 | Taking out and dismantling Air termination, single pointed, aluminium rod fixed/embedded in PCC in any position at any height of building including cleaning the surface complete all as specified and as directed. |
| 235 | Supply and fixing Air termination, single pointed, copper rod 12mm dia and 300mm long at roof surface at any height complete all as specified and as directed.Note :- PCC block for fixing shall be measured and paid separately under appropriate item of BOQ) |
| 236 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in bed block for embedded the termination rod (lightening protection system) & similar work etc at roof surface at any height including necessary form work complete all as specified and as directed. |
| 237 | Supply and fixing in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 4 Nos, 8mm dia 25mm long hex head screw, fixed on wall surface including making connections of down earth conductors and earthing stripsincluding taking down old any typecomplete all as specified and as directed. |
| 238 | Material and labour for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including copper earthing strip 25x3.15mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto 7.5 mtr length, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I)including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and copper earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 239 | Net CONTRACT SUM will be worked out in General Summary after deduction of ‘CREDIT SCHEDULE’ amount inserted by MES. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail