| 1 | M & L for taking down old unserviceable street light /flood light fittings of any wattage/ any height of pole/ walls/ any location for repairs/ replacement of burnt out accessories and rectifying the fault complete all as specified and as directed by Engineer-in-Charge.Notes- (i)Cost of repair and replacement with new fittings/accessories and T& P shall have deemed to be included with unit quoted rate.(ii) Drivers and surge protection units shall be measured and paid saperately at supply only rates under relavent item of schedules. |
| 2 | Fixing only street light fittings obtained after repairs/replacement carried out vide serial item No. 1 of any wattage, on poles/walls, any height comprising of LED Drivers, internally prewired, mounting on existing 40 mm /25 mm GI pipe or bracket arms with pole fixing attachments and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, testing complete all as specified and as directed by engineer-in-charge.Note- Cost of connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm from junction box to street light /flood light and required minor spares, T & P and testing shall also have deemed to be included with unit quoted rate. |
| 3 | Fixing only flood lights obtained after repairs/replacement carried out vide serial item No. 1 of any wattage, on poles/walls, any height comprising of LED Drivers, Surge protection units,other connected accessories, internally prewiredand connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, testing complete all as specified and as directed by engineer-in-charge.Note- Cost of connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm from junction box to flood light /flood light and required minor spares, T & P and testing shall also have deemed to be included with unit quoted rate. |
| 4 | Supply only LED Street light driver of 70/60 watt compatible with existing make complete all as specified and as directed. |
| 5 | Supply only LED Flood light driver of 90/120 watt compatible with existing make complete all as specified and as directed. |
| 6 | S&F surge protection device 10 KV compatible with existing makecomplete all as specified and as directed |
| 7 | S & F in repair Factory made PVC Junction Box of size 225 x 295 x 122 mm with openable shutter and locking arrangement, with terminals suitable for 35sq mm, 3.5 C, 1100Vcable, IP 66/69 rating, suitable for Pole mounting and fixed with clamps made out of 25 X 3mm flat iron with suitable nuts, bolts, gland lugs etc duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 8 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed. |
| 9 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed. |
| 10 | Removing excavated materialsto a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting pointcomplete all as specified and as directed |
| 11 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. |
| 12 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured) |
| 13 | Material and labour for cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 14 | Materials and labour for providing cement concrete Type C1 1:2:4 ( 20 mm graded aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating including necessary form work completeall as specified and as directed . |
| 15 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 sqmm 3.5 core laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down of unserviceable cable complete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule \"A\"/BoQ. |
| 16 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 3.5 core laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down of unserviceable cable complete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule \"A\"/BoQ. |
| 17 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.5 core laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down of unserviceable cable complete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule \"A\"/BoQ. |
| 18 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4 core laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down of unserviceable cable complete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule \"A\"/BoQ. |
| 19 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4 core laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down of unserviceable cable complete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule \"A\"/BoQ. |
| 20 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 2 core laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down of unserviceable cable complete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule \"A\"/BoQ. |
| 21 | Supply and fixing in repair LED Energy efficient & Long life Street Light Luminaire of 70 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 22 | Supply and fixing in repair LED Energy efficient & Long life Street Light Luminaire of 90 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 23 | Supply and fixing in repair LED Energy efficient & Long life Street Light Luminaire of 100 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 24 | Supply and fixing in repair LED Energy efficient & Long life Street Light Luminaire of 120 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 25 | Supply and fixing in repair LED Energy efficient & Long life Street Light Luminaire of 60 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 26 | S & F of Energy efficient & long life LED Flood Light fitting 300 watt, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver of 4 Kv including taking down existing light fittings of any descriptioncomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 27 | S & F of Energy efficient & long life LED Flood Light fitting 100 watt, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver of 4 Kv including taking down existing light fittings of any descriptioncomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 28 | S & F of Energy efficient & long life LED Flood Light fitting 120 watt, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver of 4 Kv including taking down existing light fittings of any descriptioncomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 29 | S & F of Energy efficient & long life LED Flood Light fitting 170 watt, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver of 4 Kv including taking down existing light fittings of any descriptioncomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 30 | S & F of Energy efficient & long life LED Flood Light fitting 210 watt, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver of 4 Kv including taking down existing light fittings of any descriptioncomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 31 | Supply and fixing in repair LED Energy efficient decorative Post Top Lantern of 25 watt, 5700 K, with Pressure Die Cast Aluminium Housing,with Opal Acrylic Diffuser, IP65 Protection, electronic driver, all accessories internally prewired and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 32 | Supply and fixing in repair LED Energy efficient decorative Post Top Lantern of 20 watt, 5700 K, with Pressure Die Cast Aluminium Housing,with Opal Acrylic Diffuser, IP65 Protection, electronic driver, all accessories internally prewired and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 33 | Supply & fix in repair of PVC insulated, PVC sheathed cablewith stranded copper conductor of size 1.5 sq mm , 3 core, 1100 Volts gradecomplete all as specified and directed by Engr - in - charge. |
| 34 | Supply and fixing in repairs Surface & wall mounted Energy efficientLED Mirror Tube Light Fitting, of 10 W, 6500 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 35 | S&F in repair of LED step light 7 watt for outdoor application with IP 65protection complete all as specified and as directed . |
| 36 | Supply and fix All in One solar LED street light 30 W with lumen capcity 150 Lum/W complete with minimum 48WP Mono-Crystalline Solar Panel, Battery of minimum -24Ah, 12.8V Lithium Ferro Phosphate battery, MPPT Solar Charger Controller capacity 12 V, 5 A, Inbuilt BMS technology,Material Housing – Aluminium Extruded LED, CCT - 5700 K, Dynamic Dimming function, Conforming to LM 79 for light,IP 65 standards, IEC 61215, 61730 -1&2 for Solar Panel and IEC 62133-2 :2017 for Lithium battery with necessary fittings incl supply, Autonomy-02 days with differential erection and fixing of 7 Meter high Hot Dip Galvanised (HDG) Octagonal Pole with Top Dia 70mm and bottom Dia 130 mm with pole shaft thickness of 3mm, base plate 200mmx200mmx12mm, hole dimention 24x32mm, with single arm bracket of length 1500mm with 4 number foundation bolts EN8 grade of size M20 x 600 mm long J typeas per OEM\"s directions etc, complete all as specified and as directed.Note: (i) The contractor shall furnish original bill certificate Purchase voucher, test certificate and warranty certificate of the street lightfrom manufacturer.(ii) Quoted rate inclusive of Replacement Warranty for the period of 2 Years for street light and 10 years for solar panel.(iii) Installation shall be done in the presence of OEM rep.(iv) Earth work and PCC works shall be measured and paid separately.(v) Anything missed out in the technical specifications but technically required for efficient working of the Street lights is deemed to be included in the quoted rate. |
| 37 | S &F in repair 9 W Decorative gate light made up of high grade unbreakable polycarbonate material complete all as specified and as directed. |
| 38 | Material and labour for GI tubing light grade 40 mm bore including all fittings, for mounting of post top lantern for a suitable height of 1.5 mtr for each fitting and for cable protection including GI socket at both end of pipe to avoid damages to the cable complete all as specified and as directed by Engineer-in-charge. |
| 39 | Material and labour for cross arm bracing, support, clamps and back plate fabrication from structural steel section including nuts., bolts, washers welding bending cold or hot drilling holes in any shape or size as indicated or directed by Engr-in-Charge and incltwo coats of aluminium paint over a coat of zinc chrome primer complete all as specifiedand directed. |
| 40 | Supply and fixing in repair of security light GI Bracket made out of 40 mm bore GI Tube, Medium Grade of size not exceeding 1.20 m in length and 0.3 Rm 32mm dia at one end for inserting of light fitting, bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of synthetic enamel paint over a coat of primer red oxide zinc chrome primer complete all as specified and as directed. |
| 41 | Clearing and cutting of the shrubs, vegetation grass, bushes, plants and saplings grown and surface dressing not exceeding 15 cm deep including removing the materials to a distance not exc 60 mtr complete all as specified and as directed by Engineer-in-Charge. |
| 42 | S & F in repair of Rigid non metallic heavy grade PVC conduit of dia 20 mm including of all Tee, bends, elbows, reducers, and fixing such as couplers lock nuts, saddles, pipe hooks etccomplete all as specified and as directed by Engineer-in-Charge. |
| 43 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proofLT feeder piller box of of size 1.3 x 1.00 x 0.5 mtr, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist ofaluminium bus bars of high conductivity of suitable size of 400 amps and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. |
| 44 | The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following: [a] MCCB, 125 Amps, 4 pole, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, B Curve – 1 Nos [Incoming][b] MCCB, 100 Amps, 4 pole, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, B Curve –02 Nos [Outgoing][c] MCB TPN 63 Amps 10KA - 02 Nos [Outgoing][d] Contractor 3 pole 32 amp -01 Nos [Outgoing][e]Toggle switch 6 amp-01 Nos[f] Timer(analog) with battery backup-01 Nos[g] Overload relay 5-8A- 01 Nos[h] Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 1 Nos [1 Set].[j] Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 1 Nos.[k] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set. |
| 45 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proofLT feeder piller box of of size 1x0.8X0.5 mtr, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist ofaluminium bus bars of high conductivity of suitable size of 400 amps and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. |
| 46 | The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following: [a] MCCB, 250 Amps, 4 pole, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, B Curve – 1 Nos [Incoming][b] Outgoing through bus bar[c] Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 1 Nos [1 Set].[d] Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 1 Nos.[e] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set. |
| 47 | Material and labour earthing complete with galvanised earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.50 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, GI strip of size 25x4mm to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanizediron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:1.5:3) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) and all as shown in Electrical Plate No. 3 of SSR (Part-1)of 2009 including taking down of unserviceable earthing complete all as specified and as directed.(Note:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |