| Sl. No. | Item Description |
| 1 | Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth, for foundation, etc and getting out in soft/loose soil |
| 2 | Excavating trenches, not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete |
| 3 | M&L for Hard core with broken stone of gauge n.exc. 63mm deposited spread and levelled in layers n.exc.15cm thick |
| 4 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations |
| 5 | M&L PCC 1:4:8 type D2 as in sub base as directed & specified by Engr in Charge |
| 6 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in in CM 1:4 |
| 7 | M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6. |
| 8 | Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point |
| 9 | Returning , filling in, incl spreading leveling, watering and well ramming in layers n.exc 25cm in soil |
| 10 | Excavating in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface from soft/loose soil complete all as specified and directed by Engineer - in- charge. |
| 11 | M&L for PCC in foundations, filling and mass concrete type C2 (1:3:6) (using 40 mm graded stone aggregate comlete all as specified and directed) |
| 12 | M&L for M-25 (20 mm graded aggregates) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer in Charge |
| 13 | M&L for M-25 (20 mm graded aggregates) as in walls Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; includingattached pilasters and buttresses complete all as specified and as directed by Engineer in Charge |
| 14 | M&L for M-25 (20 mm graded aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge |
| 15 | Use and waste of flat fair finished surfaces of formwork Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter |
| 16 | M & L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping complete all as specified and as directed by Engineer-in-Charge |
| 17 | M&L for mild steel deformed TMT bars of 6 to 8 mm dia cutlength bent to shape required incl cranking bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less thatn 0.9mm dia or securing with clips.s complete all as specifed and directed. |
| 18 | M&L 10mm thick cement plasters in CM 1:6 on concrete or brick wall surfaces finished even & smooth with out using extra cement |
| 19 | M&L for 15 mm rendering in two layers with 10 mm withCM 1:6 & 5 mm thick with CM (1:4) with using water proffing compoundon fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified |
| 20 | M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for preparation of newly decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down and stopping of distempered surface, filling of cracks etc and applying two coats of oil bound distemper over a 1 mm thick puttyover a coat of pirmer complete all as specified & directed by Engineer-in-Charge. |
| 22 | M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint over a coat of primer of approved shade/tint and filling cement based putty in cracks complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F roof trusses (framed), trussed, purlines, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance places, cleats etc grade Fe-401-W (Gde-E-250) quality \"A\" complete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etcgrade Fe-401-W (Gde-E-250) quality \"A\" complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F Hand rails, half round or othersteel section or core for wooden hand-rail straight portion, drilled andcountersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.)including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L preparation of new steel surfaces over 10cm in width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 27 | S&F pre-painted galvanium aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mps as in roof covering / cladding to wall, fixed withself tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275all as specified and directed. |
| 29 | M&L for 25mm thick (1:2:4) Type-B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre. |
| 30 | M&L for non- skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.11 sqm but not exc 0.18 sqm and including 15 mm thick bedding to tiles in cement mortar 1:4, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match. |
| 31 | M&Lglazed ceramic coloured, designer & pattern (dark & light shade combination) tilesin450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:3and d complete all as specified and directed. |
| 32 | M&L non skid coloured designer ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with Epoxy to match with and including 15mm thick screed bed in CM (1:6) compete all as specified and directed. |
| 33 | S&F 15 mm bore GI tubing tubes \"medium grade\" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. |
| 34 | S&F 20 mm bore GI tubing tubes \"medium grade\" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. |
| 35 | S&F PVC (SWR) 75 mm dia of outlet nahani trap/floor trap with grating including jointing with solvent cement |
| 36 | S &F salt glazedstone ware gully traps squre of size 150 x 150 mm including setting & jointing to drains in CM (1 ; 2) including eartwork, concrete in beds, surrounds, kerbs ettc and CI grating etc complete fixed in repairs, all as directed by Engr - In- Charge. |
| 37 | S&F 75 mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 38 | S&F 110 mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 39 | Supply and fixing 75 mm bore PVC (SWR) bends any radius with access door complete all as specified. |
| 40 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal |
| 41 | Supply and fixing 110 mm bore PVC (SWR) bends any radius with access door complete all as specified. |
| 42 | S&F 110mm dia PVC (SWR) junction single (Single Tee )equal or unequal |
| 43 | S&F 650 x 400 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers and fixed to wall with wood plugs complete all as specified |
| 44 | S&F vitreous china wash down water closet pan, \"Pedestal\" coloured , including fixing bolts etc including PVC seat cover white flat bottom including MS, CP or aluminium anodised hinges devices including PVC low levelflushing cistern 10 ltr capacity with all internal fitting, inlet, outlet pipe connections etc. completeall as specified and directed. |
| 45 | S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with andincluding 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. |
| 46 | PVC connections 15mm size with PTMT nuts of length 450mm |
| 47 | S&F rotational moulded polythylene water storage tanks (cylindrical vertical with colsed top) hoisted and fixed in postion all as spd and directed of 1000 ltrs capacity. |
| 48 | S&F Brass chromium plated tubular towel rail 20 mm dia D type 60 cm long between flanges. |
| 49 | S&F gun metal globe or gate valves with iron wheel head, screwed boh ends foriron pipe and fixedof 20mm dia on stone, concrete, block, slab or wall in repairs of ISI marked |
| 50 | S&F 15 mm diachromium plated fancy type angle cock with wall flange consealed typeof equivalent make specified here in after complete all as specified and directed. |
| 51 | S&F Waste coupling of PTMT(half or full threaded) .(Minimum weight 32mm-45gms/40mm-60 gms) |
| 52 | S&F PVC waste pipe 32 mm dia for urinal or wash basin etc complete |
| 53 | S&F Bib taps, castcopper alloy withcrutch or butterfly handle, screweddown, screwed foriron pipe or forbrass ferrule andfixed |
| 54 | S&F 10 Itrs PVC (White) valve less cyphonic action type, flushing cistern low level with inlet ball valve float, handle. aluminium brackets for bottom support fixing with gutties embeded in wall with drilling machine etc complete all as specified and as directed by Engr-in-Charge.Make -Prayag-501 or Equavalent aprroved by GE[Make-Cera/HISL(Sleek)/Parryware(Slimline)] |
| 55 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) |
| 56 | S&F Vitrous china wash hand basin, white, flat back of size 550 x 400 mm white excluding taps,and plug and porcelain stopper but including bracket, cutting for and pinning the ends of brackets, PTMT waste coupling of 32 mm dia (half or full threaded )(Min wt 45 gms /40 mm -60 gms) & waste pipe as suitable complete all as specified and directed. |
| 57 | S&F Pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe 15 mm |
| 58 | Supply and fixing Fiber Glass Reinforced plastic (FRP)Door Frames of cross section 90 mm x 45 mm havingsingle rebate of 32 mm x 15 mm to receive shutter of 30mmthickness.The minte shall be moulded with fireresistant grade unsaturated polyester resin and choppedmat. Door frame laminate shall be 2mm thick and shallbe filled with uitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 59 | Supply and fixing to existing door frames 30 mm thickGlass Fibre Reinforced Plastic (FRP) panelled doorshutter of required colour and approved brand andmanufacture, made h fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks ofeasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames,omplete as specified by the manufacturerand as per directions of Engineer- in-charge. |
| 60 | S&F Mild steel medium weight cold rolled butt hinges 75 mm long,all as specified & directed. |
| 61 | S&F aluminium anodised barrel tower bolts ofextrudedsection 150 mm long complete all as specified. |
| 62 | S&F factory made single extruded WPC(Wood polymer compsite)solid door window/ceosetory windows& othr frames/chowkats of size 65x125mm comprising of virgin PVC polymer of K value 58-60(suspension grade calciumcarbonate and natural fibers (wood powder/rise husk0 and non toxic additives (maximum toxicity index of 12 for 100gms fabricated with miterd joints after applying with PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750kg/cum,screw withdrawl strength of 2200N (face) & 1100N (edge) ,minimum comp ressive strength of 58 n/mm2 ,modules of elasticity 900n/mm2 and ressisistance to spread of flame of class A category with property of being termite/borrer proof ,water /moisture proof and fire retirdent and fixed in position with MS hold fast /Lugs/SS dash fasteners of required dia and length complete all as spd and direction of engr-in-charge. |
| 63 | M&L FORFactory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S Sscrews shall be paid separately) |
| 64 | S&F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive glass, gauge etc (withsash bars) edges but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers as specified in SSR Part-I Section 8 Clause 8.24(a), fitted to chowkats complete all as directed. |
| 65 | S&F mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed |
| 66 | S&F 125 mm Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed |
| 67 | S&F 150mm long aluminium handle cast type anodised complete all as specified and directed. |
| 68 | S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete |
| 69 | S&F aluminium anodised barrel tower bolts ofextrudedsection 150 mm long complete all as specified. |
| 70 | S&F factory made mild steel windows (Box Type ) with side hung shutters including glazing bars to receive glass, dovetailed or weldedwith and including necessary welding, reveting, tower bolt, hanlde, holdfast, hinges and steel peg stay as per Drg No.CEJZ/TD-2013/01 sheet (1/3, 2/3, 3/3). The rates include for painting with 50 micron thickness of poweder coated painting over a shop coat of zinc chromate primer with approved colour complete all as specified and directed. |
| 71 | S&F steel window box type with side hung shutters Factor made including box type hinges with steel handle and steel peg stay complete w/o glazing bars dovetailed or welded including necessary welding, riveting, tower bolt, handle, holdfast, hinges and steel peg stay. The rates include for painting with 50 micron thickness of poweder coated painting over a shop coat of zinc chromate primer with approved colour complete all as specified and directed. |
| 72 | S&F steel ventilator with top hung shutter of glazed & gauged including hinges,steel peg stay complete with glazing bars including one shop coat of redoxide primer complete all as specified and directed. |
| 73 | M&L Framed work such as grills, gratings, gates etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, hand rails, cupboards frame and similar work con- forming to Fe.290.Gde-E-165 with and including necessary cutting and weldingcomplete all as specified and directed. |
| 74 | S&F Sheet glass 4.00mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 75 | S&F 4 mm thick figured glass fixed with and including necessary rubber gasket and aluminium beading all as directed |
| 76 | S&F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples |
| 77 | M&L for preparation of new steel or iron surfaces of any description, over 10 cm width or girthand applying two coats of synthetic enamel paintcomplete all as specified and directed. |
| 78 | Fixing only chain link fencing including linew ires, any mesh, size and type to any typeof standards, rails, straining bolts, etc. including provission of binding wire |
| 79 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and as directed by Engineer in charge |
| 80 | M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips confirming to Fe-410-W (Gde E-250) quality A or Fe-290 (Gde E-165) complete all as specified and as directed. |
| 81 | M&L for preparation of new or previously untreated surfaces of steel not exc 10 cm in width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 82 | S&F, GI powder caoted snap grid of sizes 605 mm x 605 mm frame work for false ceiling with main tee 32x24x1mm thick, cross tee 26x24x1mm thick and wall angle 24x24x1mm thick, flange covered with PVC thin sheet including gypsum board 7-9 mm thick, duly finished surface (thin PVC layer on gypsum board as per manufacturer instructions) size 600mm x 600mm and the same to be placed in snap grid as in false ceiling and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 83 | M&L inclding preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or gith with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge |
| 84 | M&L for reinforced concrete NP2 pipe of 150mm dia laid in trenches and jointed incl crading complete all as specified and as directed by Engineer-in-Charge |
| 85 | M&L for concreate bed to drain peipe 200 mm dia incl packing under and hunching against the sides or pipe after they are laid and teste din PCC (1:3:6) type C2 for following size of pipe |
| 86 | M&Lfor PCC (1:2:4) type B1 (using 20m graded stone aggregate) in coping , kneelers, apex stones bed plates, rounded or chamfered on edge all as specified and directed by Engr-in-charge |
| 87 | M&L for PCC (1:2:4) tye B2 (using 12.5mmgraded stone aggregate) in surface channel & draining. |
| 88 | M&L forcement concrete slab in cement concreteM 25 ( Design Mix ) type B-1 (using 20mm graded stone aggregate)in manhole covers, drain covers, shelves etc with plain faces etc complete as directed |
| 89 | M&L for rendering 10mm thick on fair faces of brick work in CM (1:4) finished even and smooth using extra cement |
| 90 | Removing of excavated material (soil) to a distance exceeding 250Mtrbut not exc 500m and deposited where directed at a level not exceeding 1.5m above the starting point |
| 91 | M&L for cutting into existing manholes for connectng new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate)smooth finished and reforming benching as required for 200 mm bore pipe complete all as specified and as directed. |
| 92 | Extra for forming fair finished drain or channel 30cminner girth in cement concrete using extra cement incl form moulds mitred, stoped end etc. |
| 93 | Surface excn n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil. |
| 94 | Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point |
| 95 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 96 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including backing coat in 10mm thick CM (1:3) to receive Kota Stone complete all as specified and directed. |
| 97 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM1:6 complete all as specified and as directed by Engineer-in-Charge |
| 98 | M&L for 5 mm thick cement plaster on ceillingCM 1:3.even and smooth. |
| 99 | Sand filling above floors including watering complete all as specified and as directed by Engineer-in-Charge |
| 100 | M&L machine pressed precast cement concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment jointed in neat cement slurry and pointed in cement mixed with pigment to match the shade of paver block complete all as specified and directed by Engineer-in-Charge. |
| 101 | M&L for 75mm PCC 1:3:6 type C1 (using 20mm graded aggregate) in plinth protection,floors and pavings. |
| 102 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 103 | M&L for complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and including filling cracks or holes with white cement putty/POP and applying two coats ofweather proofpaint over a coat of primer of same make of approved shade/tint over two coat of wall care putty @ each layer 1mm thick all as specified & as directed. |
| 104 | M&L for preparing old plastered or unplastered surfaces of ceiling includingcrack and small hole filled by wall care putty/POP and applying one coats of white wash on old decorated surfacecomplete all as specified and directed. |
| 105 | M&L for complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and including filling cracks or holes with white cement putty/POP and applying two coats of oil emulsion distemper (OBD) over a coat of primer of same make of approved shade/tint over two coat of wall care putty @ each layer 1mm thick all as specified & as directed. |
| 106 | S&F vitreous china (flat back) counter type wash basin of size550 x 400 mm over granite slab of size 1.2m x 0.6m x 18mm thick, PVC Connection, waste coupling etc all as specified and directed by Engineer-in-Charge |
| 107 | S&F in repairs vitreous china squatting pan water closet ‘orrisa’ pan size 580x440mm incl. Integral foot rest including cement concrete bedding etc complete all as specified. |
| 108 | S&F stainless steel soap dish fixed to wall as directed. |
| 109 | S&F stop valve cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15 mm bore or union and fixed |
| 110 | S&F SS grating doom 100mm dia of PTMT (Minimum weight 25gms) over floor trap in white / grey cement to Match with existing floor complete all as specified. |
| 111 | S& F PVC (SWR) 110mm junction double, (double T), equal or unequal |
| 112 | M&L PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement |
| 113 | S&Fballvalves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of20 mm ( min wt 210gm) |
| 114 | S&F extruded aluminum alloy handles 150mm size fabricated type anodized all as specified. |
| 115 | S&F floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring, fixed in floor(overall length of cover plate 150mm). |
| 116 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 117 | S&F 5.50 mm thick reflectedglassof selected qualityfixed to aluminumframing in square incudingrubber beading and packing complete all as specified and directed by Eng - in - Charge and approved by the GE. |
| 118 | S&F solid PVC door frame of size 50mmx 47mmmade out of 5mm plain colour PVC sheet reinforced with MS square tube as per specification and drawing. |
| 119 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. Tubes for top & bottom rails, MS frame shall be covered with heat moulded lain colour PVC Ç\"channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame wedded/sealed to the stiles, & rails with suitable PVC sheet beading and jointed together with solvent cement, suppling and fixing in the frame at site as per secification & drawing. |
| 120 | S&F SSButt hinges, medium weight , cold rolled mild steel, and fixed 100 mm |
| 121 | S&F 200 mm long Aluminium anodised barrel tower bolt of extruded section |
| 122 | S & F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 200mm |
| 123 | S & F in repair brass chromium plated shower rose 125mm size with swivel joint suitable for fixing with 15mm bore pipe ncluding shower arm 15mm bore size with bend of 45 degree with flange |
| 124 | M&L for brickwork with flyash bricks, straight or curved on plan to any radius in half brickthick walls built in CM (1:4) complete all as specified and as directed by Engineer-in-Charge |
| 125 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etcincluding modular press steel with cover plate and frame, complete, all as specified & directed. |
| 126 | All as per item No. 125.00 (here-in-before)but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board. |
| 127 | All as per item No. 125.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. |
| 128 | AllaspersrlitemNo.125.00(here-in-before) but for 15 Amp socket out let by using 2.50 sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent boardincluding provn of2.50 Sqmm unsheathed, multi strandedcopper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed. |
| 129 | S&Fmodular type switch , flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed. |
| 130 | S&F modular typeswitch piano flush type, single pole, one way, 15 Amp, 230 Volts. |
| 131 | S&F modulartype socket outletmultipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed. |
| 132 | S&F modulartype socket outletmultipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 133 | S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminalswith back plate etc complete all as specified and directed. |
| 134 | S&F LED light fitting 1x40W, regal batten for LED including ultra bright glass LED Tubelight , Aluminium Housing with very high efficacy, single / double side connection all as specified and directed. |
| 135 | S&F in reapir of street light LED light fitting 20 watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. |
| 136 | S&F in repair of MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA complete all as specified and directed. |
| 137 | S&F in repair of MCB SPN, 240 volts, 40 Amps to 63 Amp breaking capacity 10KA complete all as specified and directed. |
| 138 | S&F in repair of MCB TPN, 240 volts, 100 Amp breaking capacity 10KA complete all as specified and directed. |
| 139 | S&F in repair of sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 140 | S&F in repair of sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 141 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I) including taking out old existing earthing complete all as directed. |
| 142 | S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 volts grade drawing through and incl concealed conduit 25mm dia medium duty incl acessories such as Tee, Bend elbow etc ISI marked with and incl PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly incl cutting chasing of wall, if required andmaking good disturnbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed by Engineer in charge incl taking down old unsv sub main wiring. Note Two lengths of 6 sqmm cable one length of 6 sqmm cable and one length of PVC Conduit will be measured as one length |
| 143 | Supplying, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 50 sqmm 4 core all as specified and directed.(Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc complete all as specified and directed by Engr-in- Charge. |
| 144 | Supplying, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 6 sqmm 3 core all as specified and directed.(Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc complete all as specified and directed by Engr-in- Charge. |
| 145 | M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. |
| 146 | M&L for sand cushioning 230mm thick withdry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thick after laying of cable) andpunned down to 180mm after laying of cablein trenches for protection of cable etc complete all as specified and directed. |
| 147 | Supply and fix electric water heater,storage type steel body with copperinner tank and heating element upto2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc |
| 148 | Supply and fix steel tubular swaged poles type type 410 SP-55 (11.0 metres long)complete with CI base plate and finial including junction box foundation and coping |
| 149 | Supply and fixing LED street light fitting 90 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete. |
| 150 | Supply, laying, jointing and testing galvanized iron tubes 50mm bore medium grade with all fittings with all fittings, tee, socket, union, reducer socket, flange and socket confirming to IS-1239, laid in trenches or alongwall or roofs and in floors etc complete all as specified |
| 151 | Supply, laying, jointing and testing galvanized iron tubes 40mm bore medium grade with all fittings with all fittings, tee, socket, union, reducer socket, flange and socket confirming to IS-1239, laid in trenches or alongwall or roofs and in floors etc complete all as specified |
| 152 | Supply, laying, jointing and testing galvanized iron tubes 25mm bore medium grade with all fittings with all fittings, tee, socket, union, reducer socket, flange and socket confirming to IS-1239, laid in trenches or alongwall or roofs and in floors etc complete all as specified. |
| 153 | Supply, laying, jointing and testing galvanized iron tubes 20mm bore medium grade with all fittings with all fittings, tee, socket, union, reducer socket, flange and socket confirming to IS-1239, laid in trenches or alongwall or roofs and in floors etc complete all as specified. |
| 154 | Supply and fix gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20mm bore fixed in repair/replacement complete. |
| 155 | Supply and fix gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 40mm bore fixed in repair/replacement complete. |
| 156 | Supply and fix gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 50mm bore fixed in repair/replacement complete. |
| 157 | M&L construction of brick masonry 40 & 50mm gate valve pit of size 450mm x 450mm x 600mm (internal dimensions of chamber) depth to be reckoned from the top of PCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 x 40 x 6mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus spoil to a distance not exceeding 50mtr 15 cm thick PCC 1:4:8 type D-2 in PCC foundation projected by 15cm all round from the outher face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified. |
| 158 | Cutting of 80mm bore existing CI/DI pipe for taking up of damaged/leakage portion or reducing to required length before laying insertion of branch T etc complete all as specified and directed (both cut shall be measured as one job) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail