| 1 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, in any type of hard dense soil, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, in any type of soft/desintegrated rock, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M&L for plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate, as in foundation filling and mass concrete, complete all as specified and asdirected by Engineer-in-Charge. |
| 4 | M&L walling of random rubble stonemasonry ,uncoursed,cwell bonded, bedded and solidly hearted,built in cement mortar 1:4,complete all as specified. |
| 5 | M&L for raised pointing to random or polygonal rubble ,uncoursed or brought upto courses in CM 1:4 , complete all as specified. |
| 6 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified. |
| 7 | M&L for plain cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | M&L for TMT steel bars10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for rendering 15 mm thick, on fair faces of brick or concrete surfacesin cement mortar 1:6and finishing the surfaceeven and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for rendering 15 mm thick, on fair faces of brick or concrete surfacesin cement mortar 1:4 by using water proofing compound as per manufacturer instruction and surfaces finishedeven and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge. Note:- WPC will be measured and paid separately. |
| 11 | M&L forhardcore of broken stone or boulders of gauge n exc.63 mm ,deposited,spread and levelled in layers n xec. 15cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L for 100 mm thick cement concrete 1:4:8 type D2 (by using 40mm graded stone aggregate)as in sub base of floors etccomplete all as specified and directed. |
| 13 | M&L for non skid ceramic coloured tiles Ist quality7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.11 sqm, but not exceeding 0.18 sqm as in floors etc. set and jointedin neatcementslurry and pointed in white or coloured cement to match the shade of tiles, laid over and including15mm thick screed bed or bedding layer in cement mortar1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by Engr-In-Chargeand contractor shall not have any claim whatsoever on this account. |
| 14 | M&L for Glazed ceramic tiles, coloured, of size350mm x 250mm/450 mm x 350mm, thickness not less than 7mm as in vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tile, fixed over and including 10mm thick rendering (bedding layer) on brick/concrete surface in cement mortor 1:4, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by Engr-In-Chargeand contractor shall not have any claim whatsoever on this account. |
| 15 | M&L for preparing newly plastered surfaces and applying 2 coats of Oil Bound Distemperover 1 mm thick wall care putty on walls complete all as specified and directed. |
| 16 | M&L for prepration new plastered surface and applyingAcrylic smooth exterior paint of required shade(two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm) complete all as specified and as directed by Engineer-in-Charge. |
| 17 | S&F 500 litre capacity rotational moulded polyethylene water storage tank(cylindrical vertical with closed top) three layers hoisted and fixed in position including 20 mm bore of dia float valves complete all as specified. |
| 18 | S&F 20mm bore dia of pipe gun metal,globe or gate valves, with iron wheel head, screwd both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 19 | S&F GI tubing medium grade including all fittings fixed in floor/ walls/ ceilling etc 20mm dia bore complete all as specified and as directed by Engineer-in-Charge. |
| 20 | S&F GI tubing medium grade including all fittings fixed in floor /walls / ceilling etc, 15mm dia bore complete all as specified and as directed by Engineer-in-Charge. |
| 21 | S&F Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc complete all as specified and directed by the Engineer-in-Charge. |
| 22 | S&F 10 lit capacity PVC low level flushing cistern 10 litre capacity with 32 mm bore polythene flush pipe of sufficient lengthincluding internal fitting (valveless syphonic ) etc complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F Vitreous China wash basin, white, flat back, size 550x400mm and S&F brackets including cutting for and pinning in ends of brackets or erecting stand including waste pipe , 32mm Waste fittings, brass, chromium plated for glazed basins, with long screwed shanks and fly-nuts, flange end bedded in red lead cementcomplete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F PVC connections 15 mm size with PTMT nuts of length 450 mm , complete all as specified . |
| 26 | S&Fbib taps cast copper alloy with butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore all as specified complete all as specified and as directed by Engineer-in-Charge. |
| 27 | S&F 15mm bore dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 28 | S&F asChromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge. |
| 29 | S&F aluminium anodised tubular towel rail 20mm dia 600mm long including necessary aluminium brackets complete all as specified and as directed by Engineer-in-Charge. |
| 30 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 31 | S&F 40 mmHDPE pipes of pressure rating 6 kgf/cm2 laid in trenches/fixed to walls ,ceilings or in floors complete all as specified and as directed by Engineer-in-Charge. |
| 32 | S&F asPVC (SWR) floor trap plain of 75mm outet Dia with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-Charge. |
| 33 | S&F grating square 150mm size of PTMT and fixed with white cement complete all as specified and as directed by Engineer-in-Charge. |
| 34 | S&F PVC(SWR) GULLY trap 125/110mm ,setting and joining with cement solvent complete all as specified and as directed by Engineer-in-Charge. |
| 35 | S&F 75 mm PVC (SWR)pipes single socketed , in any length with rubber ring joints,laid intrenches or floors,and fixed as in repairs complete all as specified and as directed by Engineer-in-Charge. |
| 36 | S&F 110MM bore PVC(SWR) pipes single socketed , in any length with rubber ring joints,laid intrenches or floors,and fixed as in repairs complete all as specified and as directed by Engineer-in-Charge. |
| 37 | S&F 75MM bore PVC(SWR) pipes single socketed , in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge. |
| 38 | S&F 110MM bore PVC(SWR) pipes single socketed , in any length with rubber ring joint fixed to wallscomplete all as specified and as directed by Engineer-in-Charge. |
| 39 | S&F75mm PVC (SWR) Single T (Equal or unequal) provided with access door to pipe complete all as specified and as directed by Engineer-in-Charge. |
| 40 | S&F110mm PVC (SWR) Single T (Equal or unequal) provided with access door to pipe complete all as specified and as directed by Engineer-in-Charge. |
| 41 | S&F 75 mm bore of dia PVC (SWR) vent cowl complete all as specified and as directed by Engineer-in-Charge. |
| 42 | S&F 110 mm bore of dia PVC (SWR) vent cowl complete all as specified and as directed by Engineer-in-Charge. |
| 43 | S&F 75 mm bore of pipe stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stay to wall or roof complete all as specified and as directed by Engineer-in-Charge. |
| 44 | S&F 100 mm bore of pipe stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stay to wall or roofcomplete all as specified and as directed by Engineer-in-Charge. |
| 45 | S&F forpowder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sectionscomplete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F Anodised aluminium grill(anodised transperent or dyed to required shade according to IS:1868 with minimum anodic of grade AC 15) of approved design/pattern,with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws@200mm centre to centre,including cutting the grill to prper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening , all complete all as specified. complete all as specified and as directed by Engineer-in-Charge. |
| 47 | S&FStainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 48 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification, complete all as specified |
| 49 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification, complete all as specified. |
| 50 | S&F 100mm sizeButt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 |
| 51 | S&F 100 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F 100 mm extruded aluminium alloy handles fabricated type anodized complete all as specified and as directed by Engineer-in-Charge. |
| 53 | M&L for 150 mm dia reinforced concrete pipes, class NP-2, laid and jonted complete with collars laid in trenches and jointed as specified and directed by Engr-in-Charge. |
| 54 | M&L concrete bed of cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate)as in bed to drain pipes including forming cradle after they are laid and tested for 150mm bore RCC pipe complete all as specified and as directed by Engineer-in-Charge. |
| 55 | M&L for providing precast cement concrete 1:2:4 type B1(20mm graded stone aggregate) in apex stones,etc including chamfers, weatherings throating etc and setting in mortar 1:4 (for manholes etc.), complete all as specified and directed. |
| 56 | M&L for providing cutting into existing manholes for connecting new drains, making good to pipe and rendering,cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching required complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified. |
| 58 | M&L for cement concrete in foundations, filling and mass concrete 1:2:4 type B2 (using 40mm graded stone aggregate)complete all as specified complete all as specified and as directed by Engineer-in-Charge. |
| 59 | S&F rolled sections as in main & cross beams , columns/vertical posts, rafters, purlins where connected to common rafters and running rails & any other places with angles cleats or other connected plates, brackets, wind ties etc confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified. |
| 60 | S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attahment,confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified. |
| 61 | S&F Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 62 | M&L preparation of new Steel surface synthetic enamel paint of two coats in any description, over 10 cm in width or girth, not otherwise described, over a coat of Red oxide, zinc chrome, specified and directed. |
| 63 | Returning ,filling in soft/loose soil.hard/dense soil including spreading .levelling , watering and well ramming in layers not exc 25 cmcomplete all as specified and as directed by Engineer-in-Charge. |
| 64 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing outside MoD land complete all as specified and as directed by Engineer-in-Charge. |
| 65 | Taking down cement plaster, of any description on brick or stone or cement concrete walls/ceiling including raking out joints, hacking for key, scrubbing down with water, complete all as specified and as directed by Engineer-in-Charge. |
| 66 | Supply only liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge. |
| 67 | M&L for complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over 1 mm thick wall care putty on walls complete all as specified. |
| 68 | M&L for preparation of old wall surfaces and fiinishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)and upto ht of 15m from GLcomplete all as specified. complete all as specified and as directed by Engineer-in-Charge. |
| 69 | S&FMild steel rag or lewis bolts,screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised,n exc15cm longcomplete all as specified and as directed by Engineer-in-Charge. |
| 70 | S&FVitreous China wash down water closet pan (pedestal pattern), including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified. |
| 71 | S&Fhealth faucet (ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25meter long flexible tube and ABS wall hook including making connectíons and fixed in position complete in all respect as specified. |
| 72 | S&F PVC 75mm (SWR) bends of any radius, complete all as specified with access door complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Cutting holes (superficial area n.exc 150 Sqcm) into or through brick walls built, in cement mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required. |
| 74 | Dismantelling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-In-Charge. |
| 75 | Supply and fix false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 of equivalent load carrying capacity with mid span deffection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm X 600mm. Additional cross less of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally from a grip of 600mm X 600mm. Grip of modular size 600mm X 600mm shall be supported by 3mm dia GI wire from purlins/soffit with and fixed complete all as specified and as directed. |
| 76 | S&F for ceiling boards made of mineral fiber tiles of size600x600x15mm in size, fixed in snap grid false ceiling frame work of approved colour, type complete fixed in position all as specified and directedcomplete all as specified and as directed by Engineer-in-Charge.Make : Armstrong Optra RH95/ FG Classic. |
| 77 | Taking down chowkats or frames with shutters ( without taking off shutters from the frame) exc 1.5 Sqm but n exc 4 sq. m each, complete all as specified. |
| 78 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mmsuitable for double door shutter comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as specified.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 79 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 80 | S&F PVC factory made wire gauged shutter with wire gauge warpped on an additional square 8mm MS solid tube and this tube shall be welded to MS tube. The wires gauge shall be stretched to tighten firmly, PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm wigth stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail all as per specification and drawing given in SSR Part II, Schdule of rates 2010 and directed but as in four panels in lieu of two panels. Note : The wire mesh shall be measured separately. |
| 81 | S&F 150mm long aluminium anodized barrel tower bolts of extruded section. complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S&F 150mm extruded aluminium alloy handles fabricated type anodizedcomplete all as specified and as directed by Engineer-in-Charge. |
| 83 | S&F 250mm length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified. |
| 85 | S&F as in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions |
| 86 | S&F for ordinary sheet glass 3mm thick and glazing with oil putty/beddings in square n exc 0.5 sq, in each panes, complete all as specified. |
| 87 | M&L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks complete all as specified. |
| 88 | M&L for Forming jambs, etc. in CM 1:6to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete all as specified. |
| 89 | Dismentling floor hearth or wall tilling including cement mortar bedding ( but not backing) complete all as specified and as directed by Engineer-in-Charge. |
| 90 | M&L coloured non-skid ceramic tiles 7-8mm thick rectified glossy (square/rectangular) areaof each tiles exceeding 0.11 sqmbut not exceeding 0.18 sqm in skirting etc , set and jointed in neat cement slurry and pointed in whiteor coloured cement to match over 15mm thick rendering in CM (1:4),completeall as specified and directed. |
| 91 | S & F Prelaminated particle board 18mm, interior grade, prelaminated both side with decorative choice lamination fixed to aluminium frame as directed by Engr -in - Charge. |
| 92 | S&FStainless steelsinks with draining board made out of1mm thick sheet for kitchenwith plugs, washers and waste pipe, cast iron cantiliver bracketsand connecting union to pipe overall size 915mmx460mmx with bowl size 410mmx330mmx160mmwith plugs, washers and wastes: including bedding in cement mortar on to dwarf walls, or inculding fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each as directed by Engr -in - Charge. |
| 93 | M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in-Charge. |
| 94 | M&L Granite slab work 18 to 20mm thick in floors steps, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade over & including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 95 | Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose\"s lamp holder from existing batten PVCconduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed . |
| 96 | M & Lforpoint wiring complete for light/ fan on independent /combine boardwith cable 1.5 sqmm (Nominal area) FRLSHPVC insulated multistranded unsheathed copper conductor,drawn in and includingPVC casing & caping , hooks , elbows, juction covers and junction boxes , aftercutting in walland sinking\"s for modular metal flush boxes suitable lengthand Min 1.6 mmthickness, Min 51 mm depthfor mounting, switches, sockets,fan regulatorwith modular cover plate with frame and making the gooddisturbed surfaces of wallin CM 1:3 with white wash or existing colour including provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switchand connected to commonearth dolly, complete all as specified anddirected. |
| 97 | All as per Srl item No -96 here in before but for onesocket outlet 5/6 amp on independent board complete all as specified and directed . |
| 98 | All as per Srl item No -96 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed. |
| 99 | All as per Srl item No. 96 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed . |
| 100 | S & F in replacement modular switch5/6 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed . |
| 101 | S & F in replacement modular switch15/16 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed. |
| 102 | S & F in replacement modularsocket2/3 pin, type 5/6 Amps 5 in 1flush type including modular cover plate and metal flush box with frame complete all as specified and directed . |
| 103 | S & F in replacement modularsocket2/3 Pin, 6/16 Amps flush type including modular cover plate with frame and metal flush boxcomplete all as specified and directed. |
| 104 | S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete including modular cover plate with frame and metal flush box complete all as specified and directed . |
| 105 | S & F ceiling rose surface bakelitethree terminals complete all as specified and directed . |
| 106 | Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light/ recess mount fitting of any sizeand refixingthe same to respective location after carrying outcleaning all the components of fittings, including replacement of nuts, bolts and connection withflexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connectorcomplete all as specified and directed. |
| 107 | S & F in replacement LED Tubelight fitting with aliminium housing andintegrated electronic driver,20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector complete all as specified and directed. |
| 108 | Supply and fixing LED street light fitting 35 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 109 | S&F in replacementLED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.all as specified and directed. |
| 110 | S & Fin replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LEDall as specified and directed. |
| 111 | S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified. |
| 112 | S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed. |
| 113 | S&F LED lamp 9W for angle holder complete all as specified and directed. |
| 114 | S & F in replacement for Sub Mainwiring with two single core 4 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts gradedrawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 4 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note : PVC cable and PVC casing caping shall be ISI marked) Note :- Two length of 4 Sqmm cable and one length of 4 Sqmm earth cable along with PVC casing caping will be measured as one running length |
| 115 | S & F in replacement for Sub Mainwiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts gradedrawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note : PVC cable and PVC casing caping shall be ISI marked)Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing caping will be measured as one running length |
| 116 | S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof , IP42 and above suitable for incorporation MCBs and isolators etcincluding taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed . |
| 117 | S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etcincluding taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed . |
| 118 | S & Fin replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply40 to 100 Amps,triple pole and neutral (TPN) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 119 | S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 120 | S & Fin replacementMCB ‘B’ series type suitable for 240 volts,10 KA,AC supply6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 121 | Disconnectingelectric connection and taking down carefully serviceable ceiling fans, exhaust fan, wall fan and keep in safe custudy. After the building repair work or as directed refixing /hanging the ceiling fan including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified. |
| 122 | S&F Heavy duty metal body exahust fan of 300mmsweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc. |
| 123 | S&Fexahust fan of 300mmsweep made of sturdy Engineering plastic ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc. |
| 124 | S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweepwithout regulator having Min air delivery 210 CFM with service value 6.00 BEE5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable sizecomplete all as specified and directed. |
| 125 | S&F wall mounting fans for 230 volts single phase400 mm sweep compl;ete all as specified and directed. |
| 126 | Supply and fixindustrial socket metal clad plug and socket with MCBs single pole 20 Amp complteall as specified and directed. |
| 127 | M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor.complete all as specified and directed . |
| 128 | M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size, Add if necessarily done in position without taking down. |
| 129 | S & F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed . |
| 130 | S & F inswitch piano flush type 5/6 Amps single pole one way complete all as specified and directed |
| 131 | S & F inswitch piano flush type 15/16 Amps single pole one way complete all as specified and directed |
| 132 | S & F inSocket outlet 5 pin 5 Amps flush type complete all as specified and directed |
| 133 | S & F inSocket outlet 2 in1, 3pin,5and15 amp flush type complete all as specified and directed |
| 134 | Supply and spreading in trenches cleardry sand for cable protection and punning down gently by hand all as specified. |
| 135 | Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches as specified and as directed. |
| 136 | Supply and lay jointing and testing and commissioning of 16 Sqmm x 2 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed. |
| 137 | To carry outEnergy Audit at Air force station Madh Island to all Electrical distribution transformers, water pumps, all type of air conditioners, Lightings, Fans / Blowers by deploying necessary tools & plant, technicians , transportation etc all as described here under :- |
| 138 | (a) Electrical distribution & Transformers :- Examination of distribution system to arrive at approximate power consumption break-up of the facility with following scope of work:-(i) Analysis of invoices (bills) for last 12 months duration to arrive at any energy cost saving.(ii)Opportunity for electricity average incremental cost of energy.(iii)Analysis of transformer loading pattern to evaluate any energy saving opportunity.(iv)Measurement of power parameters (KW, KVAr, Power factor).(v)Measurement of larger motor (greater than 11 KW rating) for instantaneous parameters like KW, voltage, ampere & power factor.Total No of substations = 09 NosTotal No of DG Sets = 06 Nos |
| 139 | (b) Water Pumps :-Pump operational efficiency evaluation based on measurement of flow, total headdeveloped & power drawn. (Subject to provision to install our pressure gauge) Identification of energy saving opportunities in terms of control system, operational strategies etc.Total No of Pump house = 03 Nos |
| 140 | (c) Split, Cassette, duct able, VRF A/C :-(i)Measurement of cooling energy generated (TR) based on actual operating condition electric energy consumption to evaluate the specific energy consumption for A/C.(ii) Identification of energy saving opportunities in Split A/C on sample basis (one in each category to be evaluated). |
| 141 | (d) Lighting:-(i)Measurement of average lux levels in certain common areas, comparison with respect to relevantstandards as per ISENA, IS etc.(ii) Identification of energy saving opportunities in lighting. |
| 142 | (e) Fans & Blowers:- (i) Performance evaluation of fans in terms of static efficiency, Suction, and discharge side pressure mapping (subject to availability of ports), air flow rate. (ii) pressure mapping (subject to availability of ports), air flow rate.(iii) Identification of energy saving opportunities based on performance, control etc. |
| 143 | Note :-(a)The following Terms and Reference are also included in the Energy audit -(i)To carry out the audit of power supply and earthing infrastructure (EP&LA) . (ii) To optimize use of electrical infrstructure by studying the HT/LT distribution network and suggest improvements.(iii) To ensure safety and security of electrical and earthing infrastructure in order to avoid fire hazards and electrical accidents. (iv) To achieve enegy efficiency by setting targets for redudction of energy consumption and carry out of energy saving devices.(v)To verift serviceability state of electrical infrastructure.(vi) To monitor CMD(Contract Maximum Demand ) and RMD (Recorded maximum Demand).(vii)To carry out rationalization of transformer in the Stn. (viii)To balance load of DG sets in the Stn.(ix) To check the power factor and suggest improvements. (x) To suggest measure to improve so as to minimize the maintenance and tarrif of the Stn. (xi) To list out defect/ deficiency. (xii)To submit the Findings and Recommendations.NOTE:- (b)The follwong data will be catered in test report - (i)Summary of energy conservation measures.(ii) Description of energy saving projects.(iii) Cost benefit analysis, vendor, or OEM details.(iv) Small briefing session of the report to the management to explain the report and way forward discussion pertaining to recommendation implementation and any constraint resolution from plant management. (v) Entire exercise will be done by Buerau of Energy Efficiency Accreditted Energy Auditor having industry experience of 20+ years. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail