| 1 | Sch \"A\" Part-I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under col.5 signifies this fact only. |
| 2 | Construction of block of 08 Qtr for Single Nursing Officers double storey using reinforcement precast concrete technology complete without mumty (non accessible roof) all as shown on typical floor plan drawings and as specified. |
| 3 | Construction of block of 01 Qtr for single Nursing Officers with attached one car parking, 01 Car parking (Garage) usingreinforcement precast concrete technology complete with (non accessible roof) all as shown on drawings and as specified. |
| 4 | Construction of block of Car Garage (for 09 No Cars) using reinforcement precast concrete technology complete all as shown on drawings and as specified. |
| 5 | Construction of block of Car Garage (for 07 No Cars) using reinforcement precast concrete technology complete all as shown on drawings and as specified. |
| 6 | TotalAmount of Sch \"A\" Part - II (Internal Water Supply Work) |
| 7 | TotalAmount of Sch \"A\" Part - III (Internal Electric Supply Work) |
| 8 | TotalAmount of Sch \"A\" Part - IV (Plumbing Work) |
| 9 | TotalAmount of Sch \"A\" Part - V (Area Drainage Work) |
| 10 | TotalAmount of Sch \"A\" Part - VI (Sewage Disposal Work) |
| 11 | TotalAmount of Sch \"A\" Part - VII (Road, Path and Culvert Work) |
| 12 | TotalAmount of Sch \"A\" Part -VIII (External Water Supply Work) |
| 13 | TotalAmount of Sch \"A\" Part - IX(External Electric Supply Work) |
| 14 | TotalAmount of Sch \"A\" Part - X (Compound Wall and GateWork) |
| 15 | Sch \"A\" Part - XI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under col.5 signifies this fact only. |
| 16 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- |
| 17 | One light/fan/bellpoint controlled by one switch |
| 18 | One 3/5 pin socket outlet, 5 Amp independent board |
| 19 | One socket outlet 3 Pin, 5 Amps on the same board |
| 20 | One two way point controlled by one two way switch |
| 21 | All as per Srl item No. 12 here-in-before but forpower point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor including earth wire with cable of size 2.5 sqmm. |
| 22 | Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 20mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly including taking down existing sub main wiring, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. |
| 23 | Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. |
| 24 | Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. |
| 25 | Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. |
| 26 | Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge. |
| 27 | Switch air break, gang operated, triple pole, mechanical operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers \"NAVTAL LOCK\" consisting of mild steel channel, operating rod 25mm dia, \"medium grade\" GI pipe; conforming to IS: 1018 for current rating 400 amps, 11000 volts grade, complete all as specified. |
| 28 | Supply, installation, testing and commissioning of step down, Transformer 11000/433 volts, 3 phase 50Hz, minimum 100 KVA, copper wound, outdoor type with off load tap changing arrangement of HT side to very secondary voltage upto± 7.5% in step of± 2.5% including suitable cable entry boxes both on HT and LT to receive 95 sqmm 3core XLPE cable on HT side complete in all respect with std. accessories and fitment confirming to IS-1180 Part-I of 2014 and level-3 as per IS-1180 latest ammendments Dyn-11 connection complete all as specified and directed. The salient features of transformer shall be as follows: a) Rating and diagram plates. b) Earthing terminals = 02 No.c) Lifting lugs.d) Thermometer pocket.e) Air release hole with plug.f) Winding /Oil temperature indicator. g) Conservation with oil level indicator.h) Castors with locking provision.j) Silica Gel breather completeNote:- Transformer must be as per Energy efficiency level-3 of IS:1180:2014 with amendment No.4. |
| 29 | Supply, installation, testing and commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15mm thick,IP-56 protection, outer and 1.6mm thick for inner door confirming to IS:8623 with angle iron (50x50x6)mm outer,floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire, 50Hz, AC, supply as per CPRI approved including provisionof digital ammeter 0-1000A, digital voltmeter 0-500 Volts, CT\"s to suitable ratio, indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 meter above ground level grouting etc; all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc; The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron. a) Aluminium bus bar, capacity 300 Amps, for Phase-R-Y-B-N-4 No.b) MCCB, TPN, 25 KA, 200 Amps- 1 No (Incoming).c) MCCB, FP, 16 KA, 63 Amps- 3 No (Outgoing).d) MCB, SPN, 10 KA, 32 Amps - 02 No.e) MCB, FP, 16 KA, 32 Amps - 1 No.f) Complete wiring of the panel board with FRLSH PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron. |
| 30 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. |
| 31 | Construction of PCC platform for transformer of size 3m x 2.5m and 1.5m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. |
| 32 | Construction of valve pit of size (60x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. |
| 33 | Cutting the existing MS/DI/CI branch line pipe line of 50mm dia, from header carefully by means of gas cutter, removing the rusted MS pipe lines, making provision for joining new MS/CI/DI pipes of same size by welding MS flanges of suitable size and making leake proof joint including all jointing materials like bolts,nuts and gaskets required at site complete all as specified and as directed. |
| 34 | Cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary excavation and earth work including repairing the same with pre mix bituminous carpet, complete all as specified and directed. |
| 35 | Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 80 litres and nominal cooling capacity of 40 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed. |
| 36 | Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. |
| 37 | Desert cooler electric driven (single phase) heavy duty motor, three speed having nominal air flow, air cooler, boasts energy efficiency and durability in its double ball bearing motor and alloy metal blade for long quiet operation. Its high technology cooling medium offers a natural breeze and the water level indicator for easy running ensures continuous use with castor wheels for easy mobility and inverter compability with following features:-i) Type-Desertii) Cooling Media-Honeycombiii) Number of Speeds -3.iv) Blower/Fan-Fanv) Water Tank Capacity - 150Lvi) Speed Control - Low, Medium, Highvii) Air Delivery -11000 cfmviii) Air Throw Distance-90 ftix) Motor Speed - 1350 RPMx) Air Deflection - 2 Waysxi) Blower/Fan Material - Metalxii) Oscillating Function, Water Level Indicator |
| 38 | Trial bore of 300mm dia upto 200m depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc., complete all as specified and directed. |
| 39 | 12.50mm graded crushed stone aggregate, complete all as directed by Engr-in-Charge. |
| 40 | 300mm thick, broken brick filling in floors or filter media laid in layers not exceeding 15cm thick spread, levelled and rammed including watering complete all as specified. |
| 41 | 300mm thick, fine aggregate (Sand) for filter media complete all as specified. |
| 42 | Perforated UPVC pipe of 150 mm bore complete all as specified.. |
| 43 | MCB, Single pole, 240 volt, 40 Amp, 10KA rating,\"B\" curve, complete all specified and directed. |