| 1 | SCHEDULE \"A\" SECTION-I(BUILDINGS/STRUCTURE WORKS) |
| 2 | Construction of block of ‘SINGLE ACCN FOR 03 JCOs WITH SCOOTER & Car Parking (D/S)’ complete all as specified and shown on drawings. |
| 3 | SCHEDULE ‘A’ SECTION-II (PART-I) (INTERNAL WATER SUPPLY WORKS) |
| 4 | Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Section-II (Part-I). |
| 5 | SCHEDULE ‘A’ SECTION-II (PART-II) (INTERNAL WATER SUPPLY WORKS) |
| 6 | Supply & fixing 15mm bore Angle stop valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & as directed. |
| 7 | S&F wall mixer,telephonic type, brass, chromium plated,fancy type, with capstan head handles with lettered \"hot\" and \"cold\", screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection,complete all as specified as directed. |
| 8 | S&F Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered \"Hot\" & \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, complete all as specified as directed. |
| 9 | S&F brass chromium plated Hand Shower (Health Faucet) with 8mm dia & 1.20m long stainless steel braided flexible tube and wall hook suitable for fixing to supply pipe of 15mm bore complete all as specified and as directed. |
| 10 | Subtotal {Total of Schedule \"A\" Section-II (Part-II)} |
| 11 | SCHEDULE ‘A’ SECTION-III (PART-I) (INTERNAL ELECTRIFICATION WORKS) |
| 12 | Lump sum price worked out by the Contractor for “Internal Electrification Works” as listed in Schedule ‘A’ Section-III (Part-I). |
| 13 | SCHEDULE ‘A’ SECTION-III (PART-II) (INTERNAL ELECTRIFICATION WORKS) |
| 14 | Material & labour for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium grade, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etcall as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.Note : (i) Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.(ii) The quoted rates of this item shall be deemed for include for modular metal flush boxes of requisite module as approved by GE. |
| 15 | All as per serial item No. 14.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified & as directed. |
| 16 | All as per serial item No. 14.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified & as directed. |
| 17 | All as per serial item No. 14.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified & as directed. |
| 18 | Supply and fixing LED light fitting retro fit type with high out put diffuser 4 feet long, 18/20 watt, 230 Volt, 50 Hz, with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 19 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 Volts, 50 Hz, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 20 | Supply and fixing of LED inverter batten tube light fitting, 1x18 Watt, 230 Volts, aluminium body with opal diffuser, IP20 and inbuilt battery back-up (ISI marked) including all accessories and including connecting up with 3 core twisted flexible copper cable with suitable size & length upto light point/ ceiling rose, complete all as specified and as directed. |
| 21 | Supply and fixing LED batten PC with motion sensor tube light fitting 20 watt, 230 Volt, 50 Hz with opal diffuser, IP20 and inbuilt motion sensor based auto dimmeing/brightness option (ISI marked) and connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 22 | Supply and fixing invertor bulb LED lamp B-22 capacity 10 watt with opal diffuser, IP20 and inbuilt battery back up (ISI marked) complete all as specified & as directed. |
| 23 | Supply and fixing Bulb LED lamp B-22 capacity 9 watt with opal diffuser, IP20 cool white (ISI marked) complete all as specified & as directed. |
| 24 | Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, system luminous efficacy of minimum 100 lumens per watt and a minimum system lumen output of not less than 3500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/ polycarbonate/ toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed. |
| 25 | NOTES FOR LED LIGHT FITTINGS :(i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13.(ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80.(iii) Contractor has to furnish a on site replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :-(a) Manufacturing defects.(b) Failure due to mechanical and electrical impact.(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. |
| 26 | Supply and fixing wall/pole mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 0.60m long, bent to shape of 120 degree angle end welded at required, fixed to wall/pole with & including mild steel clamps (02 Nos) made out of flat iron 40x6mm with nuts, bolts & washers, complete necessary fixing arrangement on pole complete all as specified and as directed. |
| 27 | Supply and fixing sheet metal enclosure, distribution board, double door type, suitable for fixing MCCBs, VTPN with 200 Amps rated copper bus bar, vertical load line, 4 way, 415 Volts, suitable for MCBs fitted, flushed in wall, fixed, complete all as specified and as directed.Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 28 | Supply and fixing MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volts, 16 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 29 | Supply and fixing MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 30 | Supply and fixing MCCB, 4 Pole, 100 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, fixed Thermal - Magnetic, complete all as specified and as directed. |
| 31 | M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI markedcables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete all as specified & as directed.Notes :-(i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 32 | Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed.Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates. |
| 33 | Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1 Sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed. |
| 34 | Material and labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4mm dia (upto the test point / cross arms earth lead upto 7.5 meter length from top of earth plate) by means of GI bolts/nuts/washers, protected by 15mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20mm bore GI medium grade pipe for watering and including funnel, wire mesh, Pit cover & frame including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part-I. Notes :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes GI pipe and earth lead upto 7.5 meter length from top of earth plate. |
| 35 | Supply, installation & testing electric Geyser (water storage type) of capacity 25 litre, vertical mounting type, glass lined inner tank, rust proof outer body, 2 KW heating element, suitable for 230V Single Phase 50 Hz AC supply, BEE 5 Star rating, energy efficient, 8 Kg/sqcm pressure withstanding capacity, Class I, ISI marked, with & including Thermostat with Thermal Cutout, heating indicator, Multi functional valve (acts as pressure release valve, non-return valve, expansion valve and vacuum release valve), PVC connection pieces, fixed all as per manufacturer’s instructions, fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 12mm dia 200mm long with nuts & washers) into the wall grouted properly to hold the geyser complete all as specified & as directed. |
| 36 | Subtotal {Total of Schedule \"A\" Section-III (Part-II)} |
| 37 | SCHEDULE \"A\" SECTION-IV (PART-I) (ROAD/PATH AND CULVERT WORKS) |
| 38 | Lump sum price worked out by the Contractor for “Road/ Path and Culvert Works” as listed in Schedule ‘A’ Section-IV (Part-I). |
| 39 | SCHEDULE \"A\" SECTION-IV (PART-II) (ROAD/PATH AND CULVERT WORKS) |
| 40 | M&L for factory made precast cement concrete solid block 1:2:4 type B1, using 20mm graded crushed stone aggregate as in kerb stone of size 300x150x150mm and the like setting in cement and sand mortar (1:4) complete all as specified and directed. |
| 41 | Subtotal {Total of Schedule \"A\" Section-IV (Part-II)} |
| 42 | SCHEDULE \"A\" SECTION-V (Part-I) (SEWAGE DISPOSAL WORKS) |
| 43 | Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Section-V. |
| 44 | SCHEDULE \"A\" SECTION-V (Part-II) (SEWAGE DISPOSAL WORKS) |
| 45 | M&L for Double Wall Corrugated Pipe (DWCPE) pipe 150mm bore of SN-8 grade, laid in trenches, complete with necessary fittings, laid and jointed on concrete bed complete pipe laid all as per IS 16098 : 2013 below ground at required depth including all jointing fixtures carriage, barricading, lighting arrangement, cutting of any type of road etc including testing complete all as specified & as directed. |
| 46 | Subtotal {Total of Schedule \"A\" Section-V (Part-II)} |
| 47 | SCHEDULE \"A\" SECTION-VI (Part-I) (EXTERNAL WATER SUPPLY WORKS) |
| 48 | Lump sum price worked out by the Contractor for “External Water Supply Works” as listed in Schedule ‘A’ Section-VI (Part-I). |
| 49 | SCHEDULE \"A\" SECTION-VI (Part-II) (EXTERNAL WATER SUPPLY WORKS) |
| 50 | M&L for drilling and tapping cast iron water mains (in position) for branch connection of the internal dia 80/100mm GI/DI pipe complete all as specified and as directed. |
| 51 | Subtotal {Total of Schedule \"A\" Section-VI (Part-II)} |
| 52 | SCHEDULE \"A\" SECTION-VII (EXTERNAL ELECTRIC SUPPLY WORKS) |
| 53 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 120 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed.Note:- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 54 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed.Note:- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 55 | Material & labour for river sand cushioning using clean local Tibba fine sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed. Note :- Punned thickness shall be considered for payment purpose. |
| 56 | M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed. |
| 57 | Material & labour for Galvanized iron tubing, 50mm bore medium grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of electric cable complete all as specified & as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 58 | Material & labour for Galvanized iron tubing, 80mm bore medium grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of electric cable complete all as specified & as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 59 | M&L for Boring of holes under road, pavement, hard standing, etc by trench less technology using ultra sounding technique and necessary machine without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed. |
| 60 | M&L for earthing to equipments etc with & including galvanised mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed.Note : Upto 7.5m length of pipe 40mm bore and GI strip shall be deemed to be included in unit rate quoted by tenderer. |
| 61 | Supply and fixing, installation, testing and commissioning of LT bus bar feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, factory made powder coated as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50 Hz, 433 volts, 300 Amps rating capacity RYBN insulated with sleeved insulation complete, PCC platform made out of 1:2:4 type B1 and pedestal of 30cm height from GL with suitable nut, bolts, washers etc. all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed LT Panel made by CPRI approved manufacturer conforming to IS 8623-1993. Note : The lay out drawing of the panel shall be got approved from GE before panel fabrication and shall be fabricated from CPRI approved manufacture.(a) Incomer : MCCB 4 Pole 200 Amps with breaking capacity 30 kA adjustable type with extended terminals - 01 No.(b) Three phasewire copper bus bar 300 Amps rating capacity RYBN insulated with sleeved insulation complete.(c) Digital Ammeter with CT - 03 Nos.(d) Digital volt meter - 01 No.(e) LED RYB indicator lamps - 01 Set. |
| 62 | Subtotal (Total of Schedule \"A\" Section-VII) |
| 63 | SCHEDULE \"A\" SECTION-VIII (EXCAVATION AND EARTH WORK) |
| 64 | Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-VIII. |