| 1 | Clearing and removal of rubbish upto a distance of 30m outside the periphery of the area as per technical specification clause 201. |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping groundwithin 50 metres lead. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres leadin cement mortar as per direction of Engineer-in-charge. |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Km. from the site of work and including watering, dressing etc. Rate to include cost of all materials, labour and T&P etc. required for proper completion of the work. S.I. No. 255 |
| 6 | providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 7 | brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 8 | Prov and laying in position specified grade of reiforced cement concrete excluding the cast of centering,shuttering, finishing and reinforcement up to plinth level-1:1.5:3 concrete mixes |
| 9 | Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 10 | Steel reinforcement for RCC work including starightening, cutting, bending, placing in position and binding all complete upto plinth level-Thermo mechanically treated bar Fe500D or more. |
| 11 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. |
| 12 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on new work |
| 13 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. DSR-13.8 |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 15 | Supply and fixing of 10 cm. Internal dia A. C. down pipes complete with rose heads bends, and gratings and including supply of necessary M.S. clamp 25 cm. X 3mm. Fixed to walls, with and including supply of 15 cm. Long 6 mm. dia, nails all materials, labour and T&P etc. required for proper completion of the work and also including repair of plaster, pointing etc. if damaged during fixing of the pipes. S.I. No. 730 |
| 16 | Supply and fixing 6 mm. (1/4\") China white glazed tiles in flooring or in skirting or Dado laid with 1 : 3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials, labour and T & P etc. required of proper completion of the work. S.I. No. 628 |
| 17 | Providing and laying vitrified floor tile in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS:15622,of approved make in all colourd and shades,laid on 20mm thick cement mortar 1:4 jointing with grey cement slurry@ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete-Size of tile 600X600mm |
| 18 | 2.5 cm. (1\") thick 1:2:4 plain cement concrete floor with cement, approved coarse and 2 cm. Graded approved stone ballast laid in panels finished with 3 mm (1/8\") floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and including 8 cm. (3\") thick base concrete consisting of cement, local sand and brick ballast 4 cm. Gauge in the proportion of 1:4:8 and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish, including supply of all materials, labour, T & P etc. required for proper completion of the work. S.I. No. 601 |
| 19 | Providing and fixing false ceiling at all height, including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive), as per specifications and drawing, with 24 mm wide T-section exposed flanges having 0.33 mm thick web and 0.50 mm thick flanges of mild steel zinc coated and the ceiling system laid on hangers fixed with GI cleats and steel expansion fasteners, including 12 mm thick mineral fibre ceiling tiles of approved texture, design and shade, laid in grid, complete as per direction of Engineer-in-Charge.-8mm thick fully perforated calcium silicate board |
| 20 | providing and making wooden almirah with hardwood frame, plywood/board shutters, laminate finish, locking arrangement, complete as per direction of Engineer-in-Charge. |
| 21 | providing and making wooden side table with seasoned hardwood frame, plywood/board top, laminate finish, complete as per direction of Engineer-in-Charge. |
| 22 | supply and fixing of electric wiring with wall fan and light and switch board, complete as per direction of Engineer-in-Charge |
| 23 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate z section and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasterners of required dia and size, including necessary filling up the gaps at junctions. i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion:21.1.1.1 - Anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, minimum anodic coating of grade AC 15) |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubbers/ neoprene gasket etc. complete as per the architectural drawings and the direction of engineers incharge . (cost of aluminium snap beading shall be paid in basic items) : 21.3.2 with float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 25 | Providing and fixing 19 mm thick BWR grade plywood panelling with decorative laminated sheet on exposed side, fixed on wooden frame / aluminium framework, including necessary adhesive, nails, screws, edge beading and polishing of unexposed surface, complete as per direction of Engineer-in-Charge |
| 26 | supply and fixing A C 2 ton with stablizer |
| 27 | visitor chair |
| 28 | supply and fixing of water supply and all sanitary fitting , complete as per direction of Engineer-in-Charge Please Enable Macros to View BoQ information |