| 1 | EARTH WORK |
| 2 | Earth work in surface excavationnot exceeding 30 cm in depthbut exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge: |
| 3 | All kinds of soil |
| 4 | CEMENT CONCRETE (CAST IN SITU) |
| 5 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | REINFORCED CEMENT CONCRETE |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 11 | Foundations,footings,basesof columns,etc.formass concrete |
| 12 | CLADDING WORK |
| 13 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 14 | WOOD AND P. V. C. WORK |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202(PartI)non-decorative type,core of blockboardconstruction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 16 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 17 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Note :- Aluminum hinges shall not be used in wooden shutters, stainless steel hinges shall be preferred. |
| 18 | 100x75x4 mm |
| 19 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 20 | 250x16 mm |
| 21 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 22 | 200x10 mm |
| 23 | 150x10 mm |
| 24 | 100x10 mm |
| 25 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 26 | 125 mm |
| 27 | 100 mm |
| 28 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 29 | Twin rubber stopper |
| 30 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 31 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer- in-Charge. |
| 32 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. |
| 33 | 30 mm thick plain PVC door shutters |
| 34 | STEEL WORK |
| 35 | Providing and fixing T-iron frames for doors, windows and ventilators of mildsteel Tee-sections, jointsmitredandwelded,includingfixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 36 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 38 | Hot finished welded type tubes |
| 39 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 40 | 10 x 80 mm |
| 41 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: |
| 42 | 4.0 mm thick glass panes |
| 43 | FLOORING |
| 44 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 45 | Size of Tile 600x600 mm |
| 46 | ROOFING |
| 47 | Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : |
| 48 | 1.60 mm thick with zinc coating not less than 350 gm/m2 |
| 49 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 50 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 51 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 52 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 53 | Ridges plain (500- 600mm) |
| 54 | FINISHING |
| 55 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
| 56 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 57 | Two or more coats on new work |
| 58 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 59 | Old work (one or more coats) |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 61 | One or more coats on old work |
| 62 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 63 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 64 | REPAIRS TO BUILDING |
| 65 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 66 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 67 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 68 | Dismantling and Demolishing |
| 69 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 70 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 71 | Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 72 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 73 | Of area 3 sq. metres and below |
| 74 | Of area beyond 3 sq. metres |
| 75 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 76 | Of area 3 sq. metres and below |
| 77 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 78 | Of sectional area 40 square centimetres and above |
| 79 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 80 | Asbestos Cement sheet |
| 81 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 82 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 83 | SANITARY INSTALLATIONS |
| 84 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 85 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 86 | ProvidingandfixingP.V.C.lowlevelflushingcisternwithmanually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 87 | 10 litre capacity - White |
| 88 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : |
| 89 | White solid plastic seat with lid |
| 90 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 91 | Semi rigid pipe |
| 92 | 32 mm dia |
| 93 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 94 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 95 | WATER SUPPLY |
| 96 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 97 | 45 cm length |
| 98 | 15 mm nominal bore |
| 99 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 100 | 15 mm nominal bore |
| 101 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 102 | 15 mm nominal bore |
| 103 | ALUMINIUM WORK |
| 104 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 105 | For fixed portion |
| 106 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 107 | Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 108 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 109 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 110 | Pre-laminated particle board with decorative lamination on both sides |
| 111 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 112 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 113 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 114 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer- in-charge. |
| 115 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge |
| 116 | Powder coated minimum thickness 50 micron aluminium |
| 117 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 118 | WATER PROOFING |
| 119 | Providingand applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer- in-Charge. |
| 120 | Providing and fixing wood polymer composite (WPC) boads 18 mm thick in shelves including fixing with nuts/screws/washers and bolts etc. as per direction of Engineer-in-charge. |
| 121 | Extra for providing and fixing wind ties of 40x6mm flat aluminium section. |
| 122 | Providing and fixing in position facia or eaves board with 18 mm thick wooden plastic component (WPC)boads including fixing with nuts and bolts etc.complete. 30 cm wide |
| 123 | Providing and laying hollow cement block walling upto floor five level 200 mm thick consisting of hollow block of size 400x200x200 of mix 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 10mm nominal size) having a crushing strength of 3.5N/sqm at 28 days as per IS: 2185 (part-I) 1979 laid in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 124 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length ( hold fast lugs or dash fastener shall be paid for separately).a) Second class hard wood cat-II (A) |
| 125 | Providing wood work in frames of trusess, purlins, rafters, ties post fixed in position etc. complete, superior hard word cat-II (A) (Black Chuglam, Thingan, Toungpelnes, Pylnma, koko and Mahwa). |
| 126 | Prividing wood work in frames of false ceiling, partitions etc. sawn and put up in position:a) Superior hardwood cat-II (A) (Black chuglam, Thingam, Toungpeing, Pylnma, koko and Mahwa). |
| 127 | Providing and fixing 35mm thick glazed shutter for windows with kiln seasoned and chemiclly treated superor hard wood cat-II (B) using 10 kg/sqm 4mm thick glass and stainless steel butt hinges and screws including the cost of panelling as per the direction of Engineer-in-charge. |
| 128 | Providing and fixing 50 mm dia PVC pipe in weep holes, cutting placing in posistion as per directed by Engineer-in-Charge. |
| 129 | ELECTRICAL PORTION (B) |
| 130 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 131 | Group C |
| 132 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 133 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 134 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 135 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 136 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 137 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. |
| 138 | a) 5/6 Amps |
| 139 | b) 3pin 5/6 A Socket |
| 140 | c)15/16 A switch |
| 141 | d)6 pin 15/16 A socket outlet |
| 142 | Supplying and fixing brass batten/ angle holder including connections etc. as required |
| 143 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 144 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required |
| 145 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 146 | a) 6 way (4 + 18), Double door |
| 147 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 148 | a)Single pole |
| 149 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 150 | a) 63 A |
| 151 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 152 | Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated,copper conductor, single core cable including painting etc. as required. |
| 153 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required |
| 154 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required. |
| 155 | Upto 450 mm sweep |
| 156 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 157 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 158 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 159 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 160 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 161 | a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 162 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 163 | a) Upto 35 Sqmm |
| 164 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 165 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 166 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 167 | 20 mm |
| 168 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 169 | 3 x 1.5 Sq mm |
| 170 | Supplying and fixing of modular typesurface plastic box of8 module deep (nominal size) on surface with suitable size offront cover, inner plate, screw cap and blanking plate as suitable for providing modular 5 Amps. 6 pin sockets and switches. etc. as required. |
| 171 | Supplying and fixing of modular typesurface plastic box of3 module deep (nominal size) on surface with suitable size offront cover, inner plate, screw cap and blanking plate as suitable for providing modular 15 Amps. 6 pin sockets and switches. etc. as required. |
| 172 | Supplying of lighting fixture with 20W LED Lamp with extruded polycrbonate ready to use pack equivalent to Havells Cat code LHEXBLP7PN1W020 batten Light etc as reqd. |
| 173 | Supplying of A.C ceiling fan (1200mm) sweep without regulator Elegant white in colour with all accessories etc.as required make Bajaj/usha/Crompton/orient/havells or equivalent (Havells SKU Code No FHCPA2SWHT48-ISI Marked) |
| 174 | Supplying of wall mounted Exhaust fan (300mm Sweep) with all accessories Make Bajaj /Usha/Havells/orient Equivalent to Bajaj SKU code 70003 |
| 175 | Supplying,Installation,testing and commissiioning of ASHLOK make SEE brand safe earthing electrode type-19 50mm dia.Length 2 mtrs.(Short time current -52.6rmsfor 1 sec,peak-125.6) with backfillcompound including providing masonary enclosurre with cover plate having locking arrangement etc,as required. |
| 176 | Supplying of 16 Sqmm,4 Core PVC insulated and PVC insulated and PVC Sheathed /XLPE (Heavy Duty) Armoured 1.1 KV grade Aluminium Conductor cable conforming to IS:7098 (Part -1) |
| 177 | Supplying, Installation testing and commissioning of8 Way \"G\" frame DoubleDoor Panel with incoming 1 No.400A FP 36KA MCCB \" LS\" Frame , 8 No. 100A27 KA FP MCCB as outgoing,set of cable alley , 400A FP add on incoming changeover switch with enclosure , Pre-wiredDigital meter module with Voltmeter, Ammeter, Selector Switch, CT\"s Control fuse and indicating light etc. i/c connection complete and providing 1 No. 2mm thickClass A rubber floor mat of Size 1m x 2mas required |
| 178 | Supplying of 10 Watts LEB bulb equivalent to havells LED ADORE PLUS 10 W B22 CDL 2 STARLAMPCode No : LHLDDDEAIA5R010 complete or its equivalent to ISI standard. |
| 179 | Supplying and installation of Automatic switching on /off street lights using 24 Hour Analog Time Switch ,contactor changeover and 3 pole MCB in Sintex Box |
| 180 | Supplying of fabricated street light holder / bracket made up of 40 mm GI Pipe of medium grade 200mm long, welding it in angular shape with 4 mm thick MS Plate (200 x 200mm) in size at centre, drilling the plate for fixing of screws with wall, drilling the pipe for passing wires, painting it with one coat of metal primer and two coats of aluminium paint and installing it with street light on wall, testing and commissioning as directed fixing it with wall as required. |
| 181 | Supplying of 1X 50 W LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 similar to Havells Cat No. LHEXAYP7PN6K050 |
| 182 | Supplying and fixing of electric stroage water heater similar to Havells Product code GHWAHPSWH010, white Gray 10 liter capacity rated ower 2 KW HSN code 8516 along with its inlet and out connection pipe etc. as required. |
| 183 | Supplying and fixing of LED Gate light similar toBajaj Celesta LED post top made in cast aluminium spigot housing with decorative opal polycarbonate diffser and IP65 protection Product code 111538 Luminaire type BGCL 40 W LED WH white colour etc. as required. |