| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | M&L for brick work with sub class \"B\" brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 4 | M&L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6 surface finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4 mixed with WPC @ 3% by weight of cement surface finished even and smooth without using extra cement complete all as specified and directed. (Upto the top of triple storey bldg)Note : WPC will be measured and paid separately |
| 6 | Supply only integral water proofing compound complete all as specified and directed. |
| 7 | M&L for 10 mm thick rendering on celing surface in cement mortar 1:3surface finished even and smooth complete all as specified and directed. |
| 8 | M&L for preparation of newly plastered surface of walls including corners and applying two coats (by roller) of distemper oil emulsion over and including applying of 1 mm thick wall care putty finish wall surface even & smooth complete all as specified and directed. |
| 9 | M&L for preparation of newly plastered surface of walls including corners to receive the coats as per manufacturer directions and applying two coats (by spray machine) of Smart Care Damp Proof Advanced of approved colour consist of fiber reinforced elastomeric liquid applied waterproofing membrane, formulated with select elastomeric and resilient acrylic polymers and reinforcing synthetic fiber which forms a thick, seamless, durable membrane upon curing and offers ultimate waterproofing complete all as specified and directed. Make:- Asian Paints Product Code 5457 or Berger Home Shield Dampstop Elasto or Nerolac Perma No Damp + or equivalent. |
| 10 | M&L for preparation of newly plastered surface of ceilings and applying two coats (by roller) of distemper oil emulsion on ceiling, off sets, pillar etc. over and including applying of 1-2 mm thick wall care putty finish wall surface even & smooth complete all as specified and directed. |
| 11 | M&L for complete removal of existing treatment of walls (old surface) including corners and applying two coats (by roller) of distemper oil emulsion over and including applying of 1 mm thick wall care putty finish wall surface even & smooth complete all as specified and directed. |
| 12 | M&L for preparation of old plastered surface of walls including corners to receive the coats as per manufacturer directions and applying two coats (by spray machine) of Smart Care Damp Proof Advanced of approved colour consist of fiber reinforced elastomeric liquid applied waterproofing membrane, formulated with select elastomeric and resilient acrylic polymers and reinforcing synthetic fiber which forms a thick, seamless, durable membrane upon curing and offers ultimate waterproofing including preparation of surfaces complete all as specified and directed. Make:- Asian Paints Product Code 5457 or Berger Home Shield Dampstop Elasto or Nerolac Perma No Damp + or equivalent. |
| 13 | M&L for complete removal of existing treatment of ceilings including corners and applying two coats (by roller) of distemper oil emulsion over and including applying of 1 mm thick wall care putty finish wall surface even & smooth complete all as specified and directed. |
| 14 | M&L for vitrified ceramic coloured tiles light shed of size 600x600x8-9mm thick, in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar (1:6) and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 15 | All as per item No 14 here in above but as in skirting fixed over and including 10 mm thick rendering in cement mortar 1:4,complete all as specified and directed. |
| 16 | M&L for glazed ceramic coloured tiles of size 300mm x 450mm x 6-7mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match fixed over and including 10mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 17 | M&L for non skid/mat finish ceramic coloured tiles of size 400x400x7-8mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15 mm thick screed bed in cement mortar (1:6) and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 18 | Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 19 | M&L for RCC (Nominal mix) 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 20 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. |
| 21 | S&F mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 22 | Dismantling of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 23 | M&L for 12-15 mm thick Granite, of any type, table rubbed and polished in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding complete all as specified and directed. |
| 24 | Taking down chowkhats or frames exc 1.5 sqm and n.exc 4 sqm each (without taking off shutters from the frame) and removing from the site complete all as specified and directed. |
| 25 | All as per ser Item No 24 above but n.exc 1.5 sqm each complete all as specified and directed. |
| 26 | S&F factory made 100% solid wood plastic composite (WPC) door frame 125x65mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed. |
| 27 | S&F factory made 100% solid wood plastic composite (WPC) door frame 100x65mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed |
| 28 | S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed |
| 29 | S&F 30mm thick WPC factory made 100% solid flush door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fireetardant and having screw holding capacity complete all as specified and directed. |
| 30 | S&F 30mm thick WPC factory made Glazed and skeleton shutter (conforming as per IS-4020) made from 100% lead free single extruded open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and directed. |
| 31 | S&F stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with nails complete all as specified and directed. |
| 32 | S&F stainless steel butt hinges medium weight 100 mm fixed with stainless steel screws complete all as specified and directed. |
| 33 | S&F stainless steel tower bolts 150 mm size fixed with stainless steel screws complete all as specified and directed. |
| 34 | S&F 150 mm size stainless steel handles fixed with stainless steel screws complete all as specified and directed. |
| 35 | Supply and fixing for stainless steel sliding door bolts of length 250 mm size and fixed with stainless steel screws complete all as specified and directed. |
| 36 | S&F floor door stopper of stainless steel double legged and tongue, 304 grade, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed. |
| 37 | S&F aluminium body door seal at bottom part of door to stop entry of insect inside the room complete all as specified and as directed. |
| 38 | S&F 300 mm long mild steel Helical door spring welded to steel frame or fixed to wooden door frame with screws including roller and roller plate etc complete all as specified and directed. |
| 39 | S&F powder coated Aluminium standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one nos stainless steel wire gauged shutter sliding type, 3 track numbers for sliding windows and glazed with glass 4mm thick & including glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum including locking system and provision of space for AC etc complete all as specified and directed by Engr-in-charge. Size of Track-Both Top & Bottom (Verticles sides):- 100 x 44 x 1 mmSize of Shutter Frame:- 25 x 12 x 1 mmNote: Iron grill with frame to be fixed with window (measured and paid separately) |
| 40 | S&F powder coated Aluminium partition (Fixed type) made out of aluminium powder coated section 44 x 44 x 1 mm including 4 mm thick glass/ACP Sheet complete with rubber packing/aluminum beading etc, complete all as specified and directed.Note: Iron grill with frame to be fixed with window (measured and paid separately) |
| 41 | S&F in repair 18mm thick PVC board one side prelaminated and other side plain white colour as in cup board shutters and frames, kitchen cabinet frontshutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive complete all as specified and directed. |
| 42 | S&F in repair 6mm thick PVC board both side plain white colour as in cub board selves etc fixed with screws, solvent cement/ adhesive complete all as specified and directed. |
| 43 | S&F continuous (PIANO) hinges, stainless steel, bright finish or electrogalvanised 30 mm width of flaps (when open)complete all as specified and directed. |
| 44 | S&F magnetic catcher and striking plate including letting in and fixed complete all as specified and directed. |
| 45 | S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets, decorative nobs at both ends complete all as speccified and directed. |
| 46 | S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing including taking up or down old tubing complete all as specified and directed. |
| 47 | S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing including taking up or down old tubing complete all as specified and directed. |
| 48 | M&L for cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good cutting not exc 10cm girth complete all as specified and directed. |
| 49 | S&F in repair vitreous china squatting pan, \"Orissa\" pattern, size 580x440mm white with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed. |
| 50 | S&F in repair 10 ltr capacity PVC low level flushing cistern valveless, syphonic action type, white, with inlet, ball valve, float and handle including brackets and fixed complete all as specified and directed. |
| 51 | S&F in repair vitreous china wash hand basin including brackets, white size 550x400mm including cutting for and pinning in ends of brackets, including waste coupling fitting, brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed. |
| 52 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on decorative type PVC frame and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 53 | S&F in repair 15 mm bore Pillar cocks chromium plated brass with capstain head screwed down high pressure complete all as specified and directed. |
| 54 | S&F in repair long body bib cock brass chromium plated 15mm dia with capastan head, screwed down high pressure complete all as specified and directed. |
| 55 | S&F in repair wall mixer/L bend mixer 15 mm dia, Brass chromium plated complete all as specified and directed. |
| 56 | S&F in repair 15mm dia brass chromium plated centre hole sink mixer with accessories in wash basin for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. |
| 57 | S&F in repair 15 mm dia angle cock/ angle valve/ stop valves/ conceled chromium plated with capstain head screwed down high pressure complete all as specified and directed. |
| 58 | S&F in repair CP brass shower rose 15mm dia and 100mm dia complete all as specified and directed. |
| 59 | S&F in repair PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed. |
| 60 | S&F in repair 20mm dia brass chromium plated tubular towel rails, \"D\" type, 60cm long between flanges, complete all as specified and directed. |
| 61 | S&F in repair CP Soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 62 | S&F in repair sink coupling 32mm dia PTMT half or full threaded complete all as specified and directed. |
| 63 | S&F in repair CP steel Grating round with steel frame 100mm dia all complete all as specified and directed. |
| 64 | S&F in repair 32mm bore heavy duty waste pipe not less than 60cm long for kitchen sink, WHB etc complete all as specified and directed. |
| 65 | S&F in repair glass corner shelf suitable size made of 5 mm thick toughened glass with CP railing complete all as specified and directed . |
| 66 | S&F in repair front glass shelf assembly consisting of 5 mm thick toughened glass with CP railing and brass brackets complete all as specified and directed. |
| 67 | S&F in repair stainless steel peg set of five with chromium plated back plate 304 grade, 40mm wide fixed with stainless steel screw complete all as specified and directed. |
| 68 | S&F in repair kitchen sink with drainage board ISI marked made of stainless steel sheet 1mm thick with plug, washers including bedding in cement mortar on to draft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 69 | S&F in repair wall mounted rectangular plate rack made out of stainless steel sheet 1mm thick of size 75 x 90 x 25cm complete all as specified anddirected. |
| 70 | Taking down CI/AC/PVC pipes incl fittings upto 110mm dia and removing from site complete all as specified and directed. |
| 71 | S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed. |
| 72 | S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed. |
| 73 | S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed. |
| 74 | S&F PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed. |
| 75 | S&F PVC (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed. |
| 76 | S&F PVC nahani trap of 75mm bore, with grating including jointing to waste pipe with solvent fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 77 | M&L for heavy duty anti skid ceramic coloured tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in stairs, floor etc, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 78 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed. |
| 79 | S&F rotational moulded polyethylene 500 Ltrs capacity white water storage tanks of weight not less than 18 kg (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including 15mm ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 15 mm dia including dismantling of old tank complete all as specified and directed. |
| 80 | S&F in repair Gun metal gate valve iron wheel head screwed both ends for iron pipe of 20 mm bore complete all as specified and directed. |
| 81 | Taking out & removing existing roof treatment of any description completely upto mother roof slab including racking out joints, hacking for key,sweeping clean and scrubbing down with water etc to remove dust etc,complete all as specified. |
| 82 | M&L for preparation of roof surface and treating of joints, filling of honey combs and providing 25mm thick PCC (1:2:4) type B-0 mixed with WPC @ 3% by weight of cement over roof surface complete all as specified and directed.Note : WPC will be measured and paid separately |
| 83 | M&L for Water proofing roof treatment with APP polymeric water proofing membranes of weight not less than 3Kg/sqm five layers with center core as 100 micron HMHPDE film sand witched between two layers of polymeric (Static polythene based) between laminated on both sides with 20 micron HMDPF film over a coat of hot blown bitumen with 85/25 grade @ 1.20 Kg/Sqm after priming the surface with bituminous emulsion@ 0.30 Litre/Sqm on plastered surface. Water proofing membrane should be laid with over laps 150 mm at ends and 75 mm for sides and shall be bounded uniformity by LPG torch flame over the polymeric water proofing membranes and applying semi hot blown bitumen 85/25 grade @ 1.20 Kg/ sqm dusted sand over the coat @0.5 Kg/Sqm and applying aluminium reflective paint over it as per manufacturers instructions complete all as specified and directed. |
| 84 | Dismantling of timber scantlings 40 sq cm and over in section in any position in unframed work complete all as specified and directed. |
| 85 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 86 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W (Gde E-250) quality-A complete all as specified and directed. |
| 87 | S&F Framed work such as grills, gratings, etc. or hand rails with ends of bars (angle, hollow section) shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 88 | M&L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed. |
| 89 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 90 | S&F prepainted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 91 | Demolition of cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 92 | M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm gradedcrusedstone agg) as in sub base complete all as specified and as directed. |
| 93 | M&L for coloured pre-polished rubber moulded chequred cement concrete coloured (red/yellow) tile 300mm x 300mm x 20-22mm thick with anti skid properties set, jointed and pointed in neat cement slurry as in floor with grey cement and pigmentlaid over and including 20 mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 94 | M&L for 18-20 mm thick Machine cutkota stone slab flooring in one colour laid over and including 20mm thick screed base in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed. |
| 95 | All as per item No. 94 here in above but as in skirting fixed over and including 10 mm thick rendering in cement mortar 1:4,complete all as specified and directed. |
| 96 | M&L for demolition of existing sunken portion (n.exc 2.0 Square metre) & taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish off the premises, cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00 Kilogram/Square metre and grouting with 25mm thick PCC 1:2:4, typeB-0 (using 12.5 mm graded stone aggregate) on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (b) Applying two coat of acrylic cementitious water proofing coating (Dr. FIXIT pidifin 2K manufactured by M/S Piditite Industries Ltd or equivalant) and followed by a overlay protective screed 15mm thick in CM(1:3) alongwith liquid water proofing compound approved make on top surfaces of sunken slab after preparation as mentioned above method of application for acrylic cementitious water proofing coating is followed as per manufacturers instructions complete all as specified and as directed.(Note:- The filling of the sunken portion to be done by using PCC 1:4:8 type D-2) |
| 97 | Taking out old damaged SGSW pipes from existing lines including necessary excavation in trenches and getting out in any type of soil alongwith supply, laying and jointing of new SGSW pipe type \"A\" 150mm dia in any length including packing under and haunching against the sides of pipes in PCC 1:4:8 type D-2 (using 40 mm graded aggregate) and returning, filling in disposal of surplus soil to a distance n.exc 50m, complete all as specified and directed. |
| 98 | Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 99 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 100 | Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed. |
| 101 | M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with suitable size hylum sheet , one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed. |
| 102 | One light/ ceiling fan/ Exhaust fan/bell point controlled by one-one way switch. |
| 103 | One lightpoint controlled by twoway switch. |
| 104 | One three pin 5 Amp socket on same board with other switches. |
| 105 | One three pin 5 Amp socket on independent board |
| 106 | All as per item No 101.00 above but wiring for one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm. |
| 107 | All as per item No 101.00 above but up to Sheet matel enclosure MCB DB with plug socket independent, with cable 4 Sq mm size, with earth continuity coductor of size 4 Sq mm. |
| 108 | S&F switch piano flush, button type 5/6 Amp SP 250 V AC complete all as specified & directed. |
| 109 | S&F switch piano flush button type 15/16 Amps SP 250 V AC complete all as specified & directed. |
| 110 | S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed. |
| 111 | S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified. |
| 112 | S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts complete all as specified and as directed. |
| 113 | S&F Bell switch paino flush button type 5 Ampcomplete all as specified. |
| 114 | S&F switch paino flush button type 5 Amp SP 2 way 250 V AC complete all as specified and as directed. |
| 115 | S&F Bell Multi Music type, 250 volts,single phase, complete all as specified and as directed. |
| 116 | S&F in replacement of sheet metal enclosure SPN with 3 pin earth metal plug and socket complete with one SPN MCB 20 Amps, 240 volts complete all as specified and directed. |
| 117 | S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 220 V AC complete all as specified and directed. |
| 118 | S&F lamp holder insulated body with back plate suitable for angle and batten fitting including LED bulb 9 watt complete all as specified and directed. |
| 119 | M&L for sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10Sqmm (nominal area) drawing in and including 25mm dia or higher, PVC concealed conduit heavy duty accessories and fittings and PVC insulated unsheathed FRLS cable copper conductor multistranded of size 10 Sqmm as earth wire upto common earth and connected to earth dolly including taking down old unserviceable wiring complete all as specified & directed. Note:03 runs of copper cable and 01 run of conduit will be measured as 01RM unit length. |
| 120 | S&F in replacement sheet metal enclosures 240 voltwith 200 Amp rated bus bar for double door 8 way DB,sIP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed. Note:MCBs will be measured and paid separately. |
| 121 | S&F in replacement sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed.Note: MCCB & MCBs will be measured and paid separately. |
| 122 | S&F MCB double pole 240 Volt 10 KA 40 Amp \"B\" series complete all as specified & directed. |
| 123 | S&F MCB single pole 240 volt 10 KA 5-32 Amp \"B\" series complete all as specified & directed. |
| 124 | S&F MCCB 415 Volt 16 KA, 4 pole, 125 Amp adjustable typeas incoming with fixing arrangement complete all as specified and directed. |
| 125 | S&F in replacementwall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. |
| 126 | S&F in replacement mirror light9/10 Watt LED tube light with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . |
| 127 | S&F in replacement of ceiling fan 1200mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc ,BLDC TYPE, 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed. (Note: Old unserviceable ceilingfan will be deposited in E/M store yard without any extra cost) |
| 128 | S&F exhaust fan, steel body AC single Phase, heavy duty, copper winding. 230V of size 300mm, 900 RPM, single phase, 230V AC with louver and making hole with fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cable from ceiling rose to connector complete all as specified & directed. |
| 129 | S&F Air ventilation fan made of sturdy Engineering plastic with louvers shutter, 250 mm sweep, 1200 RPM, single phase, 230V AC including necessary making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector complete all as specified & directed.Note: old unserviveable fan shall be deposite in E/M yard without any extra cost. |
| 130 | S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated, shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed. Note: old unserviceable Geyser will be deposited in E/ M store yard without any extra cost. |
| 131 | S & F Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one 240 Volts 20 amp single pole MCB complete all as specrified & directed. |
| 132 | S&F integral LED Bldg security light luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45wattwith efficiency100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, including bracket made of GI pipe 32mm dia light grade not less than 1.2m long and taking out old unserviceable street light complete all as specified and directed. |
| 133 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edgeof the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C-1, pre-cast RCC (1:2:4) type B-1, cover slab54 x 54 x 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009)complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy