| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. Group C. |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 3 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | Supplying and fixing following modular switch/socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required. |
| 5 | 15/16 A Switch |
| 6 | 6 pin 15/16 A Socket outlet |
| 7 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 8 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB /Isolator) |
| 9 | 8 way, double door |
| 10 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 11 | 4 way (4 + 12), Double door |
| 12 | Supplying and fixing of following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Single pole |
| 14 | Single Pole & neutral |
| 15 | Triple Pole & Neutral |
| 16 | Earthing with G.I. earth pipe 4.5 mtr long 40 mm dia including accessories ,and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal /cokeand salt etc as required. |
| 17 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required. |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm |
| 20 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm in the existing RCC/ HUME/ METAL / HDPE pipe as required. |
| 21 | Upto 35 sq. mm |
| 22 | Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE al conductor cable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle) |
| 23 | Upto 35 sq.mm |
| 24 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 25 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 26 | Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stoneaggregate 20 mm nominal size derived from natural sources |
| 27 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50metres lead as per direction of Engineer - in- charge. |
| 28 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 29 | Supplying of following size XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required. |
| 30 | 4 X 16 Sq.mm |
| 31 | 3 X 10Sq.mm |
| 32 | LED Streetlight fixture, powdercoatedpressure diecastaluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying,installation, Testing&Commissioning ofStreetlightLEDfixture powdercoated pressurediecastaluminiumbody withdriver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5KV L,N,EasperIEC61000-4-5, Driverefficiency >85%,THD< 10%asper IEC 61000-3-2,P. F.≥0.95,IP-66,IK-10,CRI>70, undervoltageandovervoltageprotection,EMI EMCAsper CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry)ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K/6500°K(Asper ANSIBin),SDCM (Standard Deviation Colour Matching) <5,Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standardcomplete inallrespecti/cexternal connectionswith1.5sq.mmFRLS/HFFR,PVC insulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt outputShape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heatsinkof aluminiumhousing such that LED junction temperature shall not rise above 90°C). |
| 33 | P/F of cable termination of PVC. box of size 15cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required. |
| 34 | LED Batten light (System lumen efficacy≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC140270 Volt,frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6500°K(AsperANSIBin),SDCM(Standard Deviation Colour Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete inallrespecti/c externalconnectionswith1.5 sq.mmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥120 <135lm/Watt output . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heatsink ofaluminiumhousing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast/Extruded aluminiumBody (Thickness > 1.20 mm) |
| 35 | Supplying, Installation, Testing and commissioining of 300mm dia sweep exhaust fan of approved Heavy duty or any other equivalent make with 1400 RPM speed along withall other accessoriesand fixing the fan on the existing wall including connection etc as required. |
| 36 | Credit items for old dismantled non functionalunserviceable 10/20Amps SP MCBAs in wherein basis and as is whereis basis |
| 37 | Credit items for old dismantled non functional 6- 32 Amps unserviceable SPN MCB As in wherein basis and as is whereis basis |
| 38 | Credit items for old dismantled non functional unserviceable 36/40 W Fl.Tube Light Fittings As in wherein basis and as is whereis basis |
| 39 | Credit items for old 6 way DB As in wherein basis and as is whereis basis |