| 1 | Cleaning of jungle DSR 2.31 |
| 2 | Excavation in foundation in ordinary soil (Loam clay, or sand ) including lift upto 1.5 m & lift up to 30.0 Mtr & including all to proper completion of work as per D.S.R 2.8.1 |
| 3 | Earth work in cutting /Filiing in ordinary Soil lead 30 m and lift 1.50 m including all as per S.I.253+231(A) |
| 4 | Filling available excavated earth in trenches, plinth sides of foundation etc in layers not exceeding 20 cm in depth , consolidating each deposited layer by ramming and watering lead upto 50m and for all lift as per D.S.R 2.25 |
| 5 | Concrete 1:4:8 cement, coarse sand and 40mm nominal size brick ballast as per S.I.275 |
| 6 | Providing and laying R.C.C in 1:1.5:3 in cement coarse sand and grit all work upto plinth level excluding cost of centering, shuttering, and reinforcement as per D.S.R. 5.1.2 |
| 7 | Centering and shuttering including strutting, propping removal in foundation and footing of column DSR 5.9.1 |
| 8 | Providing and laying R.C.C in 1:1.5:3 in cement coarse sand and grit in wall columns, struts and posts above plinth level excluding cost of centering, shuttering, and reinforcement as per D.S.R. 5.2.2 |
| 9 | Centering and shuttering including removal in columns , pillars, posts abutment DSR 5.9.6 |
| 10 | Providing and laying R.C.C in 1:1.5:3 in cement coarse sand and grit in wall slabs, beams, chajja, shelves, lintel , sill bands above plinth level excluding cost of centering, shuttering, and reinforcement as per D.S.R. 5.3 |
| 11 | Centering and shuttering including removal in lintels, beams, plinth beams , girders cantilever DSR 5.9.5 |
| 12 | Centering and shuttering including strutting, propping removal in roofs, ssuspended floors, balconies DSR 5.9.3 |
| 13 | Brick work in 1:6 cement and coarse sand above 2.25 F.M. mortar in foundation and plinth including supply of all materials,labour and t&p etc required for proper completion of the work. as perD.S.R. 6.1.2 |
| 14 | Mild steel work in R.C.C. including cutting and bebnding and all upto plinth level and above Plinth level as per D.S.R.5.22..1 |
| 15 | Structural steel work in built up section frames, trusses etc as per D.S.R 10.2 |
| 16 | First class brick work in 1:6 cement and coarse sand above 2.25 F.M. mortar in superstructure as perD.S.R. 6.4.2 |
| 17 | 12 mm thick plaster 1:6 cement fine sand as per D.S.R 13.1.2 |
| 18 | 12 mm thick plaster 1:6 cement fine sand as per D.S.R 13.1.2 |
| 19 | Providing and laying vitrified tiles 600x600mm as per D.S.R 11.41.2 |
| 20 | 12mm thick plaster 1:6 cement fine sand with floating coat as per D.S.R.13.7.2 |
| 21 | Providing and fixing 35mm thick flush door shutter as per D.S.R9.21.1 |
| 22 | Providing and fixing 25mm thick flush door shutter as per D.S.R9.21.3 |
| 23 | Painting over steel work with deluxe multi surface paint as per D.S.R.13.48.1 |
| 24 | Distempering with first quality acrylic distemper (ready mix ) over new work two or more coat as per D.S.R 13.41.1 |
| 25 | Finishing walls with Premium Acrylic Smooth exterior paint as per D.S.R 13.46.1 |
| 26 | Providing and applying white cement based putty of average thickness 1mm as per D.S. R no. 13.80 |
| 27 | Providing and Fixing 110 mm P.V.C Rain water Pipe UP PWD SOR |
| 28 | Internal Electrification-Wiring point for Light point, fan point,exhaust fan point, call bell point with 1.5 sqmm FRLS PVC insulated copper conductor in single core in surface /recessed medium class PVC conduit, with Modul;ar type switch including all as per DSR 1.10.1 Group A |
| 29 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in Recess , including providing and fixing 3 pin 5/6A modular socket and 5/6 A modular switch connections etc as required as per DSR 1.31 |
| 30 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in Recess,including providing and fixing 3 pin 15/16A modular socket and 5/6 A modular switch connections etc as required as per DSR 1.32 |
| 31 | Wiring for Circuit/Submain Wiring along with earth wire along with following size FRLS PVC insulated copper conductor in single core in surface /recessed medium class PVC conduit as required as per DSR 1.14.2 2x2.5sqmm +1x2.50sqmm earth wire) |
| 32 | Wiring for Circuit/Submain Wiring along with earth wire along with following size FRLS PVC insulated copper conductor in single core in surface /recessed medium class PVC conduit as required as per DSR 1.14. 3 2x4sqmm +1x4sqmm earth wire) |
| 33 | Supply and fixing 5A to 32 A rating 240/415V , 10KA \"C\" curve MCB including all as per DSR 2.10.1 single Pole |
| 34 | Supply and fixing Following way SPN sheet steel MCB distribution board ,240V , on surface /recess complete as per D.S.R. 2.3.3 12 Way Double door |
| 35 | Supply and fixing following rating double pole ,240V isolator in existing MCB Distribution Board including all as per DSR 2.12.2 63A |
| 36 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACas per D.S.R 19.1 |
| 37 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. S.I.1413 CAT (AA) |
| 38 | Supply and Fixing of L.E.D. Street light Fitting having die cast aluminium body suitable for 15Watts to 25 Watts including all as per S.I. 1419 Please Enable Macros to View BoQ information |