Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-01-2026 | CORRIGENDUM TO BOQ | BOQ | 19-01-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling posts or struts any type including taking out embedded portion in concrete/RCC and making good disturbed surfaces, complete all as specified and as directed |
| 2 | Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distancen. exc. 25m and making good surfaces, complete all as specified and directed. |
| 3 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, shafts, wells cess pits, manholes, pier holes, laying of cables etc. and n.exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 4 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 5 | Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 6 | Surface dressing not exceeding 15cm deep in soft/loose soil, complete all as specified and directed. |
| 7 | M & L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 8 | M & L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) for foundation, filling, DPC, mass concrete, making good to disturbed surfaces, complete all as specified and directed. |
| 9 | M&L for brickwork with fly ash bricks, old size, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed. |
| 10 | Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions and similar works, rough finished surfaces of concrete, complete all as specified and directed. |
| 11 | M & L PCC (1:2:4) type B-0 (using 20mm graded crushed stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed |
| 12 | M&L for 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 13 | M&L for 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 14 | M&L for 15mm thick rendering in CM (1:4) on other than fair faces of brick work or concrete surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and directed. |
| 16 | M & L for rolled mild steel hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 17 | M&L for mild steel screw bolt s(machine made) dia of neck 5 to 10mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or squarenut, n. exc. 5cm long, complete all as specified and directed. |
| 18 | M & L for mild steel TMT bars 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 19 | M & L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 20 | Supply only chain link MS galvanisd fencing, of size 50 x 50mm x 3.15mm, complete all as specified and directed. |
| 21 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed. |
| 22 | S & F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 23 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide, zinc crome primer, complete all as specified and directed. |
| 24 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of black japan paint (1st grade quality) over a coat of red oxide, zinc crome primer, complete all as specified and directed. |
| 25 | M&L for preparation of new steel or iron surfaces of any description n. exc. 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide, zinc crome primer, complete all as specified and directed. |
| 26 | M & L for 100mm thick PCC (1:3:6) typeC-2 (using 40mm graded crushed stone aggregate) as in sub base, floors & pavings etc. finished even and fair without using extra cement, complete all as specified and directed. |
| 27 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 28 | M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregrate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed. |
| 29 | M&L for MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410W Gde E-250 quality A, complete all as specified and directed. |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 31 | M&L for glazed ceramic coloured tiles of size 350 x 250 x7mm / 450 x 300 x7 to 8mm thick each as in skirting or dado on vertical surfaces of wall, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM (1:4), complete all as specified and directed. |
| 32 | Taking down cement plaster on brick/concrete surfaces of any description in any position incl racking out joints, hacking for key, scrubbing down with water etc and removing rubish off the premises, complete all as specified and directed. |
| 33 | M&L for preparing newly plastered surfaces of walls etc and applying two coats of distemper oil emulsion over a coat of chalk whitening primer, complete all asspecified and directed. |
| 34 | M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with water proofing compound on top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately as \"supply only\") |
| 35 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed. |
| 36 | M&L for preparation of newly plastered surfaces on wall and applying three coats of white wash, complete all as specified and directed. |
| 37 | Demolition of reinforced cement concrete (RCC water tank or similar type of RCC structure) of any description and in any position, not otherwise specifically provided for, complete all as specified and directed.(Note:-Reinforcement cut as required to facilitate demolition.) |
| 38 | M&L for RCC (Nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregrate) as in columns, pillars, piers, posts and struts etc, complete all as specified and directed |
| 39 | M&L for RCC (Nominal mix) (1:2:4) type B0 (using 12.5mm graded crushed stone aggregrate) as beams, cantilevers, lintels upto 1.5m span etc, complete all as specified and directed |
| 40 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) foundation and plinth beams and similar work, vertical or to batter, rough finished surfaces of concrete flat, complete all as specified and directed. |
| 41 | M&L for granite (of any type) tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, on floors, over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 42 | Dismantling structural steel work including doors, window, gates but excluding framed truss etc., complete all as specified and directed. |
| 43 | S & F powder coated (minimum thickness of powder coating 15 micron) aluminium anodised door comprising of frame of size 101.60mm x 44.6mm x 2.4mm thick push/pull type glazed door shutter having top and bottom section of size 83 x 44.5 x 2.4mm and 100 x 44.5 x 2.4mm thick respectively, styles section of size 80 x 44.5 x 2.4mm thick and lock rail of size 100mm x 44.5mm x 2.4mm thick including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size including 5mm thick tinted sheet glass in both panel, hinges, mortice lock, stays & aluminium anodised handle of suitable size, etc, complete all as specified and directed. |
| 44 | S&F 1.25mm thick steel rolling shutters, without ball bearing including top cover, anchoring rod, hasp and staple, erected in position as indicated, push pull or manual type, complete all as specified and directed. |
| 45 | S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. |
| 46 | S&F wall panelling with 9mm thick High Pressure Steam Cured Non Asbestos Fiber Cement heavy duty acoustic board (Density > 1450 Kg/m3. Modulus of Rupture(M.O.R)-24 MPa, Thermal Conductivity(K)- 0.0862 W/mk) confirming IS 14862:2000 & Type A Category III of ISO 8336 : 1993. (Reaction to fire-A2-S1-D0) tested as per EN13501 Part- & BS-476 Part 4, 5,6 & 7 and having noise absorption of 0.9 NRC as per ISO : 354, fixed on the supporting ‘W’ profile/ Alumunium tube or Iron tube with the help of full thretea flat head Screw (0.70mm thick having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm) placed @ 407/1220mm c/c vertically and perimeter channel (having one flange of 20mm and another flange of 30mm with thickness of 0.70mm and web of length 27mm) is fixed on the floor and the ceiling with the nylon sleeves @ 300mm c/c with expandable fasteners. Board to be fixed to the \"W’ profile with 35mm long self embedding type Fiber Cement Screws @ 300mm c/c. The boards be finished so as to have a uniform gap/groove or over lapping system. The groove should be filled up with PU sealant. Finally, both side of the boards including the edge should be primed with two coats of cement primer & exterior surface of the boards to be painted with PU paint of approved shade/make, complete all as specified and directed. |
| 47 | S & F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joint, fixed to wall with and including all necessary fixing arrangement, complete all as specified and directed. |
| 48 | S&F 110mm bore, PVC (SWR) bends, any radious, complete all as specified and directed. |
| 49 | S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, confirming to Fe 290 (Gde E-165), complete all as specified and as directed. |
| 50 | S&F pre painted galvalume aluminium zinc coating, GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 51 | S&F pre painted galvalume aluminium zinc coating, GI based plain steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 52 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. including brushing neat cement slurry with 3 kg of cement per Sqm, complete all as specified and directed. |
| 53 | M&L for forming jambs, etc. to openings (to foregoing item), with stone using cement mortar (1:4) including cutting, toothings and properly bonding into old work including facing and pointing (if necessary) to match existing work, complete all as specified and directed. |
| 54 | M&L for prepration of new wall surfaces and applying two coats of acrylic distemper over a coat of primer over and including a coat 1.5mm to 2mm thick wall care putty and prepration of putty surfaces even and smooth, complete all as specified and directed. |
| 55 | M&L for preparation new plastered surfaces of wall and applying two coats of 100% premium acrylic weather proof exterior emulsion paint, alkali & fungal resistance, approved coloure and shade (pattern deep green/camouflage), over and including a primming coat of exterior emulsion primer as per manufacturer\"s instructions, complete all as specified and directed. |
| 56 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 57 | S & F powder coated (minimum thickness of powder coating 15 micron) aluminium anodised door comprising of frame of size 101.60mm x 44.6mm x 2.4mm thick push/pull type glazed door shutter having top and bottom section of size 83 x 44.5 x 2.4mm and 100 x 44.5 x 2.4mm thick respectively, styles section of size 80 x 44.5 x 2.4mm thick and lock rail of size 100mm x 44.5mm x 2.4mm thick including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size including 5mm thick tinted sheet glass in both panel, hinges, mortice lock, stays & aluminium anodised handle of suitable size, etc complete all as specified and directed. |
| 58 | S&F powder coated (minimum thickness of powder coating 15 micron) aluminium anodised sliding window shutter frame comprising of 3 track sliding window made out of aluminium extruded section of bottom frame of weight not less than 1.175 Kg/RM, top and side frame of weight not less than 0.423 Kg/RM, top and bottom rail of shutter of weight not less than 0.336 Kg/RM, in two panel and shutter with and including 5mm thick selected quality tinted glass and third one with and including stainless steel wire mesh and overall aluminium decogrill of size 100 x 100 x 8mm as approved by GE with standard aluminium channel out side, with and including handles, cleat glazing clips, special auto lock, dry set rubber gasket, complete all as specified and directed. |
| 59 | S&F for 600 x 600mm GI frame work for seamless ceiling comprising of Gl perimeter channnel 0.55mm thick with two unequal flanges of 20 and 30mm and web of of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, hanger with 4-6mm dia GI (length as required) adjusting level fixed to roof slabs/truss by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expension hold fast evers 12.5mm dia 40mm long including providing 6mm thick non asbestos fibre cement building board fixed or laid/ inserted to GI framework with screws, for fixing 600mm x 600mm grid, complete all as specified and directed. |
| 60 | Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting, regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc, complete all as specified and directed. |
| 61 | M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including concealed, rigid PVC conduit (ISI marked) not less than 20mm dia, medium grade, including all conduit accessories with and including concealed modular box of suitable size for mounting modular switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting& making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed.Note: - (i) Rate quoted shall deemed to be included for cost of modular box (as per number of module of outer cover) and concealed in wall including cutting and sinking of boxes and making good tothe walls. (ii) Provision of blank plates as per site requirement shall deemed to be included in the unit quoted rate. |
| 62 | All as per item No 61.00 here-in before but for one 3 pin 5 Amps socket outlet on the independent board controlled by other swtich, complete all as specified and directed. |
| 63 | All as per item No 61.00 here-in before but for one 3 pin 5 Ampssocket outlet on same board controlled by other switch, complete all as specified and directed. |
| 64 | All as per ser item No. 61.00 here in above but for one 16 Amp 3/5 pin switch socket outlet independent point including PVC cable 4 Sqmm, FRLSH type, multistranded copper stranded conductor along with 4 Sqmm continious PVC insulated unsheathed multistranded copper conductor cable, FRLSH type, for as earth wire, complete all as specified and directed. |
| 65 | S&F switch, modular type, single pole, one way, 5/6 Amps, one module, 250 V AC, complete all as specified and directed. |
| 66 | S&F switch, modular type, single pole, one way, 15/16 Amps, one module, 250 V AC, complete all as specified and directed. |
| 67 | S&F socket outlet modular type, multipurpose, having provision for 2/3 pin, 5/6 Amp and 2 pin, two module, complete all as specified and directed. |
| 68 | S&F socket outlet modular type, multipurpose having provision for 3 pin, 15/16 Amp and 3 pin 5/6 Amp two module,complete all as specified and directed. |
| 69 | S&F modular cover plate with frame, 2 module, white, completes all as specified and directed. |
| 70 | S&F modular cover plate with frame, 3module, white, completes all as specified and directed. |
| 71 | S&F modular cover plate with frame, 4 module, white, completes all as specified and directed. |
| 72 | S&F wall mounted air circulator fan, heavy duty, 230 volt, 400mm sweep, 2050 RPM, with all fixing arrangement on wall and connecting with and including 3 core flexible copper cable of suitable size upto ceiling rose, complete all as specified and as directed. |
| 73 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old ceiling fan, any type and deposited to AGE E/M store yard, completes all as specified and directed. |
| 74 | S&F in replacement ceiling rose of size 65 x 50mm, surface bakelite,three terminal, completes all as specified and directed. |
| 75 | S&F LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V, AC, decorative type with driver, LED tube light of 10watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, completes all as specified and directed. |
| 76 | S&F LED lights fitting 1 x 20 W, 220V, AC, decorative boxtype with driver, holder including LED tube light/rod onnecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 77 | S&F MCB distribution board (DB), TPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 4 way, as per IEC 61439-3 with necessary lugs for incomming and outgong connections, fixed on wall,single pole andneutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any rating, complete all as specified and directed. |
| 78 | S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 8 way, as per IEC 61439-3 with necessary lugs for incomming and outgong connections, fixed on wall,single pole andneutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any rating, complete all as specified and directed. |
| 79 | S&F in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘B’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 80 | S&F in repair MCB Single Pole & Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 81 | S&F MCB 4 pole, 63 Amps, 10 KA, \"C\" curve, including connection and testing, complete all as specified and directed. |
| 82 | S&F sheet metal encloser with socket & plug top and neutral encloser with a two pin and earth plug and socket complete with one MCB double pole (DP) 20 Amp, complete all as specified and directed. |
| 83 | M&L for submain wiring, concealed, with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6 Sqmm drawn in and including heavy duty PVC conduit not less than 20mm size including 6 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old sub-main wiring of any size, complete all as specified and directed.Note:-(i) Three runs of cable and one run PVC conduit and its accessories shall be measured as one length of sub main.(ii) Cutting chases for conduit and sinking of boxes and making good to wall, floor etc. shall deemed to be included in the unit quoted rate. |
| 84 | M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3cm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanisedmeans of earth wire 4mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe medium grade of 15mm bore and watering pipe GI medium grade of 20mm bore and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC (1:3:6) type C-2 all as shown in electrical plate No-3 of SSR part-I (2009) connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion including demolition of old unserviceable earthing of any description, complete all as specified and directed.Note : (i) Proper earthing pit should be provided with pit cover.(ii) GI earth wire from earth pit to pole/panel/DB shall deemed to be included in the unit quoted rate. |
| 85 | S&F LED flood light 70 watt 230 V, AC outdoor type with thermal management in multiple optics, IP 66 protection, with impact and corrossion resistance complete with driver and lamp including fixing arrangement as per site requirement including PVC copper cable 2.5 Sqmm 3 core and connecting existing system, complete all as specified and directed. |
| 86 | Supply, installation, testing and commissioning of splittype Air conditioning units 1.5 TR indoor and outdoor complete with cordless remote control unit and with 5 star rated/ BLDC type compressor unit with non CFC refrigerant, auto swing, LED display, noise level not more than 42 dB function, comlete with all piping arrangement etc, complete all as specified and directed. Note:(i) Condensate drain pipe of best quality to be provided and fixed in suitable manner till ground level/max up to6.0 Mtr fixed on wall/floor/ceiling and unit quoted rate shall deemed to be included for the provision of same.(ii) The quoted rate also includes necessary fixing arragement for indoor and outdoor units and copper tubing upto 6.00 mtr length, brazing, welding including insulation, complete charging of refrigerator gas upto required level and filling the cavities on wall, setting of grill alignment. |
| 87 | S & F copper tube of size 1/2\", complete all as specified and directed. |
| 88 | S & F copper tube of size 1/4\", complete all as specified and directed. |
| 89 | S & F copper tube of size 5/8\", complete all as specified and directed. |
| 90 | S & F outdoor wall mounting fan blade suitable for split AC 1.5/2/3 TR, complete all as specified and directed. |
| 91 | S&F electronic voltage stabilizer of capacity 20 Amps for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 250 V, 50 Hz, with output voltage stabilized at 230 V with accuracy of ± 2.5%, with digital display automatic high and low cut out with wall mounting accessories, complete all as specified and directed. |
| 92 | S&F post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light, IP 65/66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 93 | S&F exhaust fan, steel body AC, single phase, 230V of size 450mm sweep with, blades, and frame and louversincluding cutting wall for fixing exahaust fan and making good the opening in CM (1:3) or PCC (1:2:4) type B1 as required at site, completes all as specified and directed. |
| 94 | S&F power unit suitable for load max up to 3.5 KWincluding sockets25Amps, and fourmodule box for mounting of power unit and power socket, complete as specified and directed. |
| 95 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia (outer) conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 96 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size16 sqmm 4 core, complete all as specified and directed. |
| 97 | Note: An amount of Rs.36,750.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 98 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail