| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified all as specified and directed. |
| 3 | S & F prepainted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof, fixed with self tapping screws complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not other wise provided for. |
| 5 | M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde- E- 250) quality- A. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles to store and rubbish off the premises. |
| 7 | M&L for Vitrified Ceramic tiles (Dark shade/ Double charged/ Ultra charged) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured, laid over and including 15mm thick screed bed or bedding layer in cement mortar1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 8 | M&L for Vitrified Ceramic tiles (Dark shade/ Double charged/ Ultra charged) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 10mm thick cement plaster in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 9 | Demolition of brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for Brick work with sub class `B\" bricks straight or curved on plan exceeding 6 metremean radiusbuilt in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge. |
| 11 | Taking down cement plastering on stone wall/brick wall etc including racking out of joints hacking for key scrubbing down with water etc. |
| 12 | M&L 15mm thick rendering on fair faces of wall in CM 1:6 onbrick/concrete surfaceand finishing the surface even and smooth with out using extra cement. |
| 13 | M&L 15mm thick rendering on fair faces of wall in CM 1:4 onbrick/concrete surfaceand finishing the surface even and smooth with out using extra cement. |
| 14 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over 3mm thick wall care putty, complete all as specified. |
| 15 | M&L for preparing new plastered surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces complete all as specified and directed. |
| 16 | M&L for preparation of old painted surfaces after complete removal of existing treatment and applying two coat of oil bound distemper over 3mm thick wall care putty, complete all as specified. |
| 17 | Taking down chowkats or frames with shutters (without taking off shutter from the frame) of any description alongwith fittings n.exc 1.5sqm each. |
| 18 | Taking down chowkats or frames with shutters (without taking off shutter from the frame) of any description alongwith fittings exc 1.5sqm n.exc 4 sqm each. |
| 19 | S&F Anodised aluminium frame (powder coated minimum thickness of powder coating 50 micron) for doors, windows, partition wall with one or more rebates including joining cleat for fixing, rubber packing, anodised aluminium snap on beading for fixing glass panes in frame etc complete all as specified and directed. |
| 20 | S&F Anodised aluminium(powder coated minimum thickness of powder coating 50 micron) door shutters, powder coated of any colour aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, anodised aluminum snap beading screws etc. frame will be fixed to wall ,complete all as specified and directed by the Engineer-in-Charge. |
| 21 | S&F 4mm thick , plain sheet glass, selected quality and glazing with oil putty in squares exc 0.5 sqm in each pane complete |
| 22 | S&F aluminium alloy anodised sliding door bolts 250 mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified. |
| 23 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long all as specified |
| 24 | S&F Butt hinges, medium weight cold rolled 100mm size ISI marked all as specified. |
| 25 | S&F Extruded aluminium alloy handles fabricated type anodised 150mm size all as specified |
| 26 | S&F brass mortice lock, vertical type 4 levers,, size 100 mm,complete all as specified and directed by the Engineer-in-Charge. |
| 27 | S&F door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed, complete all as specifiedand as directed by the Engineer-in-Charge. |
| 28 | S&F in repairs harrison rail/curtain rails, mild steel chromium plated with fixing brackets, stops, rollers etc., complete all as specfied and directed. |
| 29 | M & L for applying two coat of synthetic enamelled paint over one coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 CM girth or width all as directed by the Engineer in charge |
| 30 | Dismantling boarding/ false ceiling of any description, fixed in any position with nails,complete all as specified and directed by the Engineer-in-Charge. |
| 31 | S&F GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approx 900 mm centre to centre with GI cleat and steel expansion fasterner with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acress the intermediate channel at 457mm centre to cnetre including hangers 6mm dia.GI (upto 1200mm length) adjusting level fixed tp roof slabs by means of ceiling cleats made out ofGI flat 40 x 3mm size 60mm ling and expansion hold fasterner 12.5mm dia 40mm long including 8mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/ Aluminium frame work, complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F 2nd class soft wood boarding, 15mm thick, as in wall panelling, plain one side and edges tongued and grooved or rebated, fixed with nails in any situation over 12 mm thick plyboard runner including french polishing on surface of any description width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coat upto satification of Engr-In-Charge. |
| 33 | Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents, regulators, socket, lamp holders brackets,bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and also making good distrubed surfaces of wall,floors etc, complete all as specifiedand directed by the Engineer-in-Charge. |
| 34 | M&L for point wiring using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) wiring with FRLSH cable PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and including not less than 2mm thick PVC conduit with all accessories and earth continuity connected to common earth duly accommodate modular box surface/ flush type with modular white cover plate with frame for mounting fittings such as switches, sockets, fan regulators etc complete all as specifiedand directed by the Engineer-in-Charge for the following:- |
| 35 | One light /fan/bell point controlled by one No, one way 5 Amps switch. complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | One multi pin socket outlet,5/6 Amp, controlled by one No. one way switch on same board, complete all as specified and as directed by the Engineer-in-Charge. |
| 37 | One multi pin socket outlet,5/6 Amp, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | All as per serial item No 34 here-in-before ,but for one socketout let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts(ISI MARKED) including PVC insulated and unsheathedelectric cable 1100 volts, 2.5 sqmm copper stranded conductor as continuous earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | S & F modular switch piano button flush type, single pole one way 6 amps complete all as specified as directed. |
| 40 | S & F modular socket 6A, 2/3 pin combined 2 module complete all as specified as directed. |
| 41 | S & F modular switch piano button flush type, single pole one way 16 amps complete all as specified as directed. |
| 42 | S & Fmodular socket 6A/16A, 2/3 pin combined 2 module complete all as specified as directed. |
| 43 | S&F ceiling rose surface bakelite 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge. |
| 44 | S&F Fan step modular regulator, 1 module, complete all as specified and directed. |
| 45 | S & F White cover plate with frame, 4 module, complete all as specified. |
| 46 | S & F White cover plate with frame, 8 module, complete all as specified. |
| 47 | S & F Metal flush box 4 module, complete all as specified. |
| 48 | S & F Metal flush box 8 module, complete all as specified. |
| 49 | S&F LEDLights fitting 20 watt, 220V, AC Decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 50 | S&F in repair 36 watt LED light fittings 2\" x 2\" ultra modern designed architectural LED luminaire which provides sot light and glare free symmetrical illumination suitable for armstrong/ grid ceiling, mounting ceiling light fittings, flushed to ceiling complete all as specified and directed including taking down old unserviceable of any size and type. |
| 51 | Taking down ceiling fan, sealing cable end, dismantling blades, removing fan and blades and hanging the same after cleaning including connecting up alongwith provision of cable from ceiling rose or connector to fan. |
| 52 | Supply and fixing sheet metal enclosure for MCB\"s, double door SPN 230 volts, 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors, walls etc including taking down the old unserviceable DBs, complete all as directed. |
| 53 | S&F MCB SPN, 40-63 Amps, 240 volts, 10 kA rupturing capacity, \"C\" curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge. |
| 54 | S&F MCB SP, 6 -32 Amps, 240 volts, 10 kA rupturing capacity, \"C\" curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge. |
| 55 | M&L for Sub main wiring with two single core FRLS, PVC insulated, stranded and unsheathed copper conductor cable of size 10 sqmm and drawing through and including non metallic PVC conduit concealed in wall including earth continuity conductor of size 10 Sqmm PVC insulated unsheathed copper conductor (multi-stranded) and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer in charge. |
| 56 | Note:-An amount of Rs. Rs 40,449.00 on account of credit schdule for Sch \"A\" Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. |