| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | Taking down chowkats with shutter exc 1.5 but n exc4sqm each and removing from site of work complete all as specified and directed. |
| 3 | Taking down door / window/ cupboard chowkhats / ventilator with shutters ( without taking off shutters from the frame ) not exc 1.5 sqm each and removing from site of work complete all as specified and directed. |
| 4 | Dismantlingof wall and ceiling board any thickness including cover fillets complete all as specified and directed. |
| 5 | Dismantling framed work of timber scantling 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 6 | Demolition cement concrete (unreinforced ) in ground floors and pavings n exc 15cm thickness ( below or above ground level ) complete all as specified and directed. |
| 7 | Excavating in trenches, n exc 1.5 mwide and n exc 1.5 m in depth for fdn etc or for shafts, wells,, cesspits, manholes, pier holes etc. n exc 10 sq m on plan and n exc 1.5 m in depthc and getting out in hard/dense soil complete all as specified and directed. |
| 8 | M&L for 100 mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundations,filling and mass concrete complete all as specified and directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with any type of soilcomplete all as specified and directed. |
| 10 | Removing excavated soil n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 11 | M&L forRCC M-25 design mix (using 20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 12 | M&L RCC M 25 design mix ( using 20mm graded stone aggragate)for roofbeam, cantilevers, bressummers lintel over 1.5 mtr span etc complete all as specified and directed. |
| 13 | M&L for RCC M 25 (Design Mix) ( 20mm graded stone aggragate)for chajjas etc complete all as specified and directed. |
| 14 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | M&L for TMT bars 5mm dia and over and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | M & L for Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat fair finished surfaces complete all as specified and directed. |
| 17 | M & L for Use and waste for Formwork to chullah hoods, chajjas, troughs and similar items including edges similar works forfair finished surfaces of concrete in flat complete all as specified and directed. |
| 18 | M & L for Use and waste for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports over hang etc and similar works for fair finished surfaces of concrete in flat complete all as specified and directed. |
| 19 | M&L for Damp proof course (DPC) Using In cement concrete 1:2:4, type B-0 of 40mm thick to horizontal or vertical surfaces including necessary formwork completed all as spicifed and as directed. |
| 20 | M&L for plastering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement in interal surfaces complete all as specified and directed. |
| 21 | M&L for plastering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 22 | Supply only liquid water proofing compoundcomplete all as specified and directed. |
| 23 | M & L for Hardcore using Broken bricks of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface completed all as specified and directed. |
| 24 | M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded aggregate as in floor finishing the surface even and rough for receiving floor finishes complete all as specified and directed. |
| 25 | M&L for Non-skid joint free ceramic coloured tiles7mm to 8mmthickarea of each tile exceeding 0.18 but not exceeding 0.38sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including 15mm screed bed or bedding layer in CM 1:6 for laying floor finishes all as specified and directed. |
| 26 | M&L for Glazed ceramic tiles vertical surface 350x250x7mm/ 450x350x7mm thick set in 1:4 and jointed in neat cement slurry and pointed in white or colour cement .complete all as specified and directed. |
| 27 | M&L for finishing of wall with exterior weather coatpaint with Silicone additives of required shade : (Two or more coats applied @ 1.43 Ltr/10 Sqm over and includingpriming coat of exterior primer applied @ 2.20 Kg/10 sqm ). all as specified and directed. |
| 28 | S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws as specified and directed. |
| 29 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 30 | S & F for 0.63 mm thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and directed. |
| 31 | S & F for Gl frame work for suspended false ceiling GI exposed ceiling suspension system of grid size 605 mm X 605 mm with seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. lat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 32 | S&F for false ceiling of Everest designer boards of size 595mm x 595mmx4mm thick fixed on GI snap grid, complete all as specified and directed. |
| 33 | S&F Solid PVC door frame(chowkat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etccomplete all as spd and directed. |
| 34 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour of PVC sheet for top rail lock rail and bottom rail, on either side & gap insert for top rail bottom rail panelling of plain colour PVC sheets to be fitted in MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppying and fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 35 | M&L for Precast reinforced cement concrete type B0, 1:2:4 (12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated,including arrangement for fixing of hinges and fixtures as required for back filling in pressed steel door frame etc, completed all as specified and directed, |
| 36 | S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 37 | S&F 150 mm Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 38 | S&F 250 mmAluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixed complete all as specified and directed. |
| 39 | S&F 200 mmAluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixed complete all as specified and directed. |
| 40 | S&F 100 mm Butt hinges, stainless steel fixed complete all as specified and directed. |
| 41 | M&L for 100mm thick cement concrete 1:4:8 Type D-2 (40mm Graded aggregate) in floor complete all as specified and directed. |
| 42 | Dismantling floor ,hearth or wall tiling incl cement mortar beding (but not backing) removing serviceabletile to store and rubbish off the premises complete all as specified and directed. |
| 43 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt, flushing cistern and flush pipe) and seat coverincluding making goodcomplete all as specifed and directed. |
| 44 | S&F in repair for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 45 | S&F in repair for PVC valveless, syphonic action type, flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets and including flushing pipe 32 mm dia of bore, high density polyethylene pipes of pressure rating 6 kgf/sqcm complete all as specified and directed |
| 46 | S&F in repair Vitreous china wash hand basin oval shape fixed on granite top white flat back including brackets and 32 mm dia bore wastefittings brass chromium plated for glazed ware basin etc with long screwed shank and fly nut, flange and bedded in red lead cement and other end fixed inclwaste pipe of reqd lenth complete all as specifed and as directed by Engr-in Charge and approved by GE. |
| 47 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed |
| 48 | S&F in repair toilet paper holder of brass CP including screwed and fixed complete all as specifed and directed. |
| 49 | S&F in repair 15 mm dia of bore two way angle cock /stop cock fanct type chromimun plated cast copper alloy, screwed down high pressure with cruntch or butterfly handle screwed both ends for iron pipe of 15 mm bore pipe completed all as spicifed and directed . |
| 50 | S&F in repair for 15mm bore dia of CP mixture for mixing hot & cold water and fixed complete all as specified and directed. |
| 51 | S&F in repair for only 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified and directed. |
| 52 | S&F in repairbib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed down, fancy type chromium platedscrewed for iron pipe or for brass ferrule and fixed of 15mm bore size complete all as specified.. |
| 53 | S&F in repair 15mmbore dia fancy type pillar taps cast copper alloy with capston head chromium plated screwed down high pressure with or with out littred hot or cold with long screwed shanks and flynuts screwed for iron pipe complete all as specifed and as directed. |
| 54 | Taking up or down 15 mm bore steel tubing and connection incl cleaning for refixing or removal to store complete all as specified and directed. |
| 55 | Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store complete all as specified and directed. |
| 56 | Refixing old steel tubing of size 15mmand connections in new or old position (Walls, ceiling,floors, etc.)complete all as specified and directed. |
| 57 | Refixing old steel tubing of size 20 mmand connections in new or old position (Walls, ceiling,floors, etc.)complete all as specified and directed. |
| 58 | S&F 15 mm GI tubing \"Medium grade\" with all fiting and fixedto wall or celing or laid in floorcomplete all as specified and directed. |
| 59 | S&F 20 mm GI tubing \"Medium grade\" with all fiting and fixedto wall or celing or laid in floorcomplete all as specified and directed. |
| 60 | M&L in repair 75 mm dia PVC (SWR) floor trap Plain with gratting including joint with solvent cement.complete all as specified and directed. |
| 61 | S&F in repairs of vitreous China soap dish Size 160x160x90mm fixed with chromium plated brass screws.complete all as specified and directed. |
| 62 | S&F for PVC (SWR) pipes 110 mm dia single socket in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 63 | S&F for PVC (SWR) pipes 75 mm dia single socket in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 64 | M&L for 110 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 65 | M&L for 75 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 66 | S&F in repair of 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixedcomplete all as per specified and as directed. |
| 67 | S&F in repair of 20mm dia Gun-metal, globeor gate valves,with iron wheel head, screwedboth ends for iron pipe and fixed complete all as per specified and as directed. |
| 68 | Dismantling of water tanks exc 250 ltr and n.exc 500 ltr capacity and removing to store complete all as specified and directed. |
| 69 | S&F rotational moulded polyethylene water storage tank (cylindriacal vertical with closed top) hoisted and fixed in position all as specified in SSR part-I of capacity 500ltrs including 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball and nipple screwed for iron pipe and fixed complete all as specified and directed. |
| 70 | S&F in repair for 15mm dia concealed stop valves, cast copper alloy, screwwd down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unious and fixed but fancy typechromium plated with long shank and cup (concealed type) complete all as specified and directed. |
| 71 | S&F in repair for CP towel railof 20 mm dia with hook 600 mm long complete all as specifed and directed. |
| 72 | S&F in repair brass chromium plated shower roses of 125mm size with or without swivel joints, any size, including fixing to steel pipe or union completed all as spicifed and as directed. |
| 73 | M&L for AACblock masonary ( size 600 X 200 X200 mm) straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 74 | M&L for prearation of new plaster surface one coat Chalk whiting, and applying two coat of distemper oil emulsion over one coat of 1 mm thick wall care putty on internal wall surfaces.all as specified and directed. |
| 75 | S&F for Pressed steel frames for doors with one or more rebates ( Size of frame 125 X 60 mm) including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified and directed. |
| 76 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides completed all as spicified and directed. |
| 77 | S&F 35 mm thick 2nd class Hardwood glazed and skeleton shutters, open rebated and prepared to receive glass gauze etc divided into square with plain, chamfered or rounded mitred and rebated sash bars any numbers edges of framing plain, chamfered or rounded fitted with cut mitred beads for securing glass etc, the size of members of shutters shall be as specified in SSR part I, section 8, clause 8.24 ( a) complete all as specified and directed. |
| 78 | S&F for Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture1.40mm and fixed withstainless steel wire staples completed all as specified and directed, |
| 79 | S&F for Floor door stopper (140 mm ) of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor complete all as specified and directed. |
| 80 | S&F for Aluminum (Die cast) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width andof weight between 36 to 60 kg and fixed mplete all as specified and directed. |
| 81 | S&F 125 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 82 | Preparing new wooden surfaces of any description ,not otherwise, described, over 10 cm width or girth two coat of synthetic enamel ( ordinary tint ) over a one coat of pink primer completed all as spicifed and as directed. |
| 83 | Preparing new steel surfaces of any description ,not otherwise, described, over 10 cm width or girth synthetic enamel ( ordinary tint ) (two coat) over one coat over Red oxid primer completed all as spicifed and as directed. |
| 84 | M&L for light shade Vitrified Ceramic tiles 10 mmthick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to matchincluding 15mm screed bed or bedding layer in CM 1:6 for laying floor finishes all as specified and directed. |
| 85 | M&L for light shade Vitrified Ceramic tiles 10 mmthick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed inneat cement slurry and pointed in white or coloured cement to matchincluding 10 mm screed bed or bedding layer in CM 1:4 for laying floor finishes all as specified and directed |
| 86 | S&F in repairs curtains rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.complete all as specified and directed. |
| 87 | M&L for old steel surface one coat of syenthetic ensmrel paint of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 88 | M&L for Chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed and in need cement slurry in floor with grey cement and pigment and including over screed bed or bedding layer ofmortar20 mm thick laying floor finished in cement mortor 1:6complete all as specified anddirected. |
| 89 | M & L for 20 mm thick Granite (of any type) over 20 mm thick screed bed (1:4), work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cemen tmortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 90 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchincluding including 10mm thick rendering in CM 1:4 as in backing coat for tiles complete all as specified and directed. |
| 91 | M&L for Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified anddirected. |
| 92 | S & F for Framed work fixed in valley gutter including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 .using Fe 410 -W (GdeE- 250) quality-A , 20 mm thick hot rolled square steel bar.to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeall as specified anddirected. |
| 93 | S&F powder coated aluminium frame for doors,windows and ventilator with one or more rebates including joining cleat for fixing etc (Minium thickness of powder coating 50 micron ) Complete all as specified and as directed. |
| 94 | S&F powder coated aluminium frame for doors,windows and ventilator shutters of any colour, aluminium section weighing 0.55 kg/m including necessary joining cleats , glazing clips, rubber packing, handles 02 Nos in each door , hinges, powder coated aluminiumsnap beading screw etc. Complete all as specified and as directed by Engr-in-Charge (Thickness of powder coating not less than 50 micron) |
| 95 | S&F aluminium grill with bulb height 4.5mm square shape fixed on frame including necessary fixing arrangentlike U clip, flat aluminium secxtion maching with window & dia of grill . Complete all as specified and as directeed . |
| 96 | S&F for 3 mm thick Sheet glass,ordinary quality and glazing with oil putty insquare n exc 0.5sq. m in each pane complete all as specified and directed. |
| 97 | S&F for 4.8 mm thick Sheet glass,ordinary quality and glazing with oil putty insquare n exc 0.5sq. m in each pane complete all as specified and directed. |
| 98 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.complete all as specified and directed. |
| 99 | M & L for 75 mm Thick Cement concrete type C- 2,1:3:6 (40mm graded aggregate) as in plinth protection complete all as specified and directed. |
| 100 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bulbs etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 101 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross-sectional area, single core PVC insulated (FRLS), unsheathed multistrandedcopper conductor cable 1100 Volts gradedrawn through and includingrigid non-metallic PVC concealed conduit 25mm dia medium grade and accessories ISI marked and including chases Cutting and making good surfaces, suitable modular pressed steel terminal boxes 1.6mm thick (recessed) for fixing of switches, sockets etc including 1.5 Sqmm nominal cross sectional area, single core PVC insulated (FRLS), unsheathed multistranded copper conductor cable earth continuity wire to common earth and connected to earth dolly for one light / fan/ Security light/ 5Amps Indp Socket / Bell point controlled by one switch complete all as specified and directed |
| 102 | For one light point/fan point controled by one way switch |
| 103 | One 5 Amp S/Socket point on independent board |
| 104 | All as per Item No. 101 above but One 3 pin socket outlet 5 amps on same board controlled by one switch with 1.5 sqmm size cable |
| 105 | All as per Item No. 101 above but one 3 pin socket outlet, 15 amps / AC Metal Clad, controlled by one switch on independent board with 4 sqmm size cable for Phase, neutral and earth. |
| 106 | S&F Modular Switch 5/6 Amps, 1module 1 Way complete all as specified and as directed. |
| 107 | S&F Modular Switch 15/16 Amps, 1 Module 1 Way complete all as specified and as directed. |
| 108 | S&F Modular Socket 5/6 Amps, 2 Module 2 and 3 pin complete all as specified and as directed. |
| 109 | S&F Modular Socket 15/16 Amps, 2 Module 2/3 pin complete all as specified and as directed. |
| 110 | S&F3 Module Cover Plate with frame and Metal Flush Box complete all as specified and as directed. |
| 111 | S&F 8 Module Cover Plate with frame and Metal Flush complete all as specified and as directed. |
| 112 | S&F12 Module Cover Plate with frame and Metal Flush complete all as specified and as directed. |
| 113 | S&F Ceiling rose, 3 phase /PVC/ polycarbonate, isolated body complete all as specified and as directed |
| 114 | S&F in repair LED lights fitting 1x 20W, 4 Feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 115 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete |
| 116 | S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 117 | S&F in repair LED Bldg. Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete |
| 118 | S&F in repairs street light brackets made of 25 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to wall with suitable size of M.S. flat iron clamps, M.S nut & bolt with cup washers, painting to MS material with anti corrisive paint complete all as specified and as directed. |
| 119 | Supply & fixexhaust fans AC single phase 230/ 240 V, steel body with louvers of size 300 mm sweep. |
| 120 | S&F in repair SPN DB Double door 2 way with tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed. |
| 121 | S&F in repair SPN DB Double door 4 way with 200 Amp bus bar tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed. |
| 122 | S&F in repair SPN DB Double door 8 way with tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed. |
| 123 | S&F in repair MCB Two Pole 32 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 124 | S&F in repair MCB Single Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 125 | M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 4 mmGI earth wire as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..(Note : 1.If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.) |
| 126 | S&F in replacement submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 1.5 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitalbe size ISI marked Medium grade, fixed on/through wall, ceiling including 1.5 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed. (For MDB to SBD) |
| 127 | All as per Item No 126 above but 4 Sqmm |
| 128 | All as per Item No 126 above but 6 Sqmm |