| 1 | Removing existing door or windows with frame and shutters andmaking good etc. to the existing surface. |
| 2 | Dismantling steel work in built up sections in angles, tees, flats and channels of rolling shutters, grills, gates, fencing, hoardings, including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 3 | Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 4 | Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix from Engineer-in-charge and fly ash conforming tograde I of IS 3812 (Part-1) only be used as part replacement ofOPC as per IS 456 and uniform blending with cement is to beensured in accordance with clauses 5.2 and 5.2.1 of IS: 456-2000 in the items of ready mixed concrete and manufactured in fully automatic batching plant and transported to site of workin transit mixer for all leads, having continuous agitated mixer,manufactured as per mix design of specified grade for plaincement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, including the cost ofcentering, shuttering and finishing, including cost of curing,admixtures in recommended proportions as per IS : 9103 toaccelerate/ retard setting of concrete, improve workabilitywithout impairing strength and durability as per direction of theEngineer - in - charge.All works upto plinth level.M-20 grade plain cement concrete (cement contentconsidered @ 260 kg/cum). |
| 5 | Providing and laying in position plain cement concrete ofspecified grade cement with trap/granite/quartzite/gneiss metalmixing in concrete mixer including bailing out water,compacting, finishing surface, curing and including the cost ofcentering and shuttering at all level :Nominal Mix of 1:1.5:3 (1 cement OPC: 1.5 coarse sand : 3graded stone aggregate 20 mm nominal size) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 and above in superstructure above plinth level upto floor five level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Providing and applying 12 mm thick internal plaster in cement mortar 1:3 with neeru finish at all heights and locations in one coat for masonry (except stone masonry) and concrete surfaces including racking out joints, hacking of concretsurface, watering, finishing, curing, scaffolding etc. complete.(Kharsaliya sand, Packing Sand) |
| 8 | METAL FRAMED SUSPENDED CEILING (SEAMLESS)- MAIN SYSTEM, METAI_ FRAM :D SUSPENDED CEILING COMPRISES OF G I PERIMETER CHANNEL HAVING 0 55MM THICKNESS. Two UNEQUAL FLANGES OF 20 AND 30MM AND WEBor 27MM IS FIXED TO SURROUNDING WALLS / PARTITION USING NYLON SLEEVES AND SCREWS AT 450MM CENTERS THEN INTERMEDIATE CHANNEL (0 91MM THICK) HAVING TWO EQUAL FLANGES OF 15 MM EACH AND A WEB OF 45MM IS SUSPENDED FROM THE SOFFIT AT 1220 MM CENTER WITH CEILING ANGLE OF WIDTH25MM X 10 MM X 0 55 MM THICK. FIXED TO SOFFIT AT 1220 MM CENTRE WITH G I CLEAT AND STEEL EXPANSION FASTENERS CEILING SECTION OF 0 55 MM THICKNESSHAVING KNURLED WEB OF 50 .5 MM AND FLANGES OF 26 MM EACH WITH LIPS OF 10. 5 MM ARE THEN FIXED TO THE INTERMEDIAI E CHANNEL WITH CONMECTING CLIPS ACROSS TO THE INTERMEDIA CHANNEL Al 457 MM CENTERS8MM THICK SQUARE/TAPERED EDGE HILUX BOARDS OR EQUIVALENT ARE THEN SCREW FIXED ACROSS THE CEILING SECTIONS WITH 25 MMLONG, SEI F DRILLING & TAPPING SCREWS HAVING PHILLIPS HEAD WITHUNDER HEAD CUTTER FOR FIRST AND SECOND LAYER RESPECTIVELY AT 200MM CENTERS JOINTING AND FINISHING THE JOINTS OF THE FACE BOARDS ARE FINISHED WITH SPECIALL FORMULATED JOINTING COMPOUND AND 48MM WIDE FIBRE TAPE PROVIDE SEAMLESS FINISH CEMENT PRIMER (OIL BASED) TO BE PROVIDED ON ENTIRE SURFACE BEFORE PUTTY/ PAINTINGNOIE GI PERIMETER CHANNEL AND SUPPORTING MATERIALS ARE TO BE PROVIDED TOMAKE ANY OPENING FOR LIGHT FITTINGS, DIFFUSERS ETC AND SHOULD BE SUPPORTED PROPERLY TO MAINTAIN THE INTEGRITY OF THE CEILING AND SHOULD BE CHARGED EXTRA |
| 9 | Providing and laying 600 x 600 x 8 mm thk. vitrified tiles as specified below conforming to I.S.15622-2006 with water absorption less than 0.08% for flooring of an approved, quality, make and pattern/design for flooring including cement mortar bedding of 25 mm thick in 1:4 proportion, cutting, levelling, jointing, filling the joints by neat cement slurry or approved colour grout, curing, finishing etc complete as directed by Engineer In Charge. Light coloured antiskid / matt vitrified tiles. |
| 10 | Providing and fixing flush door (Without frame) shutter 30mm thick solid core,commercial grade tick wood beading around shutter and brass chrome plated aldroup 200mm tadi,200mm tower bolt,100mm 4 nos heavy duty hinges 150mm handles 2 nos. painting shutter with enamel paint in two coats over primer coat (only shutter actual measurement shall be paid) |
| 11 | Providing and fixing aluminium work for doors, windows ,ventilators and Shutters of doors,windows,partition with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS :733 and IS 1285, fixing with dash fasteners of required dia and size,including necessary filing up the gaps at junctions i.e. at top ,bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth ,rust free, straight, nitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass /stainless steel screws . all complete as per architectural drawings and the directions of Engineer in charge ( Glazing panelling and dash fasteners to be paid separately.): For fixed portion Anodise aluminium (anodised transparent or dyed to required shade according to IS 1868, Minimum anodic coating of grade AC 15) |
| 12 | Providing and fixing glazing in aluminium door ,window ,ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. completed as per the architectural drawings and the directions of engineer in charge. ( Cost of aluminium snap beading shall be paid in basic item): with float glass panes of 4.0mm thickness (weight not less than 10 kg /Sqm) |
| 13 | Providing and fixing polished natural stone tiles as specified below of approved quality, pattern andcolour for sill and jambs including preparing the surface and levelling in the desired line, cementmortar 1:3 bedding or backing, cement float, machine cutting, levelling, jointing, smooth cement plastering along the sides to match the existing surface in cement mortar 1:3, filling the joints with neat cementor pigment mixed with cement, finishing, curing etc complete as directed by Engineer In Charge.25 to 30mm thk. Kadappa stone for width upto 300mm |
| 14 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap(make as per MCGM specification) |
| 15 | Providing and fixing in position steel bars reinforcement of various diameters for R.C.C. pile, pile caps, footings,raft,retaining wall, shear wall, lift wall, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies,coping, fins, arches, etc. as per detailed designs, drawings and bar bending schedules, including straightening, cutting, bending, hooking the bars, binding with wires or tack welding, supporting as required etc. all complete at all levels. Thermo-Mechanically Treated steel bars. (Fe 500 D) Confirming to IS 1786:2008 (Item is including M.S. Scaffolding if required . No separate payment for Scaffolding.) |
| 16 | Providing and applying 20 mm thick external sand faced cement plaster by using ready-mix mortarupto 10m fromground level and at all locations in two coats .(first coat of 12mm with Waterproofing compound as per manufacturer specification and second coat is 8mm thick) for masonry (except stone masonry) and concrete surfaces including racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc. complete.(Item is including M.S. Scaffolding if required . No separate payment for Scaffolding.) |
| 17 | Providing and fixing in position uPVC/SWR (Soil/Waste/Rain) pipe of type-B 110 mm dia. in any position including all fittingsand accessories, making joints / connections water tight withsolvent cement, scaffolding if necessary and making good thedamages if any (excluding excavation and refilling the trenches) etc. complete as specified and directed.(All fittings and accessories like clamps,etc. should be of same brand. Noseparate payment shall be made for fittings and accessories). |
| 18 | Providing & fixing in position with PVC clamp, high pressure uPVC solvent cement weld plumbing pipe for distribution of potable water confirming to ASTM specifications including threading,coupling,solvent cement for joining pipe fittings, schedule 40 grade nominal bore pipes.20mm dia (Pipe Brands: Supreme Aqua Gold, Prince, Kisan, Jain, Kasta, Krishijal, Finolex, Zenith, Premium, Astron.) including fittings Bend,tee,union etc. |
| 19 | Providing & fixing in position with PVC clamp, high pressure uPVC solvent cement weld plumbing pipe for distribution of potable water confirming to ASTM specifications including threading,coupling,solvent cement for joining pipe fittings, schedule 40 grade nominal bore pipes.25mm dia (Pipe Brands: Supreme Aqua Gold, Prince, Kisan, Jain, Kasta, Krishijal, Finolex, Zenith, Premium, Astron.) including fittings Bend,tee,union etc. |
| 20 | Providing & Fixing 100mm diameter Nahani trap Jali in steel finish with necessary fixing required to make the item well functional. |
| 21 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 22 | Providing and applying first single coat of approved primer and two coats of acrylic distemper (oil bound distemper) of an approved make and colour as per manufacturers specifications to any surface, at all height and locations as directed including scaffolding, cleaning and preparing surfacesfor painting with broom by any approved means, etc. complete as directed by Engineer-in-charge.(Item is including M.S. Scaffolding if required . No separate payment for Scaffolding.) |
| 23 | Providing and applying first single coat of approved primer and two coats of synthetic enamel paint/flat oil paint of anapproved make and colour as per manufacturers specifications to surfaces specified below, at all height and locations as directed including scaffolding, cleaning and preparing surfaces for painting by any approved means etc. complete as directed by Engineer-in-charge. For steelwork/Wood Work.(Item is including M.S. Scaffolding if required . No separate payment for Scaffolding.) |
| 24 | Detailing, fabricating and fixing at desired locationusing hot rolled sections and MS Plates of grade Fe 250 as perspecifications and approved fabrication drawings (which are tobe prepared by Contractor and got approved from Engineer),transporting to site and erecting structural steel members for all heights & at all levels including provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary fixtures and operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. (The qty. for this item shall be measured for gusset plates, base plates, bolts in M.T.).(Item is including M.S. Scaffolding if required . No separate payment for Scaffolding.)(Material supply by RCF) |
| 25 | Refixing existing material after sorting and cleaning, removed from the existing structure as discribed in Item no. R3-CS-RW-10 using 8m dia polymer coated iron L or J hook bolts, galvanized iron & bituminous washers, or self drilling fastners and EPDM washers, galvanized iron clamps, nuts and bolts including sealing the existing holes with suitablematerial etc. complete and as directed. (Net Area covered by sheeting will be measured. Overlaps will not be paid separately)(Material supply by RCF) |