| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. ( Havells/Polycab make wire, Havells/Anchor/Cona Make Switch,Polycab/AKG/ make Conduit) |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 1 x 1.5 sq. mm |
| 7 | 6 x 1.5 sq. mm |
| 8 | 3 x 4 sq. mm |
| 9 | 6 x 4 sq. Mm |
| 10 | Supplying and fixing of following sizes ofPVC conduit /casing caping/flexible pipe along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20/25/32 mm dia Make/AKG/POLYCAB/FINOLEX/Shrinath Make |
| 11 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.Make Anchor |
| 12 | 5/6 A switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | 15/16 A switch switch |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make Anchor Roma/Great White/Legrand |
| 17 | 5/6 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | 15/16 A switch switch |
| 20 | 6 pin 15/16 A socket outlet |
| 21 | Bell push |
| 22 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 23 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc as required. Make Make Anchor Roma/Great White/Legrand |
| 24 | 1/2 module |
| 25 | 3 module |
| 26 | 12 Module |
| 27 | Supplying and fixing following size/ modules, modular base & cover plate for modular switches in recess etc as required. Make Make Anchor Roma/Great White/Legrand |
| 28 | 1/2 module |
| 29 | 3 module |
| 30 | 12 Module |
| 31 | Supplying and fixing suitable size GI/pvc box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 32 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 33 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 34 | Supplying and fixing suitable size GI/pvc box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 35 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 AModular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 36 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 37 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 38 | 12 way Double door |
| 39 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 40 | Single pole |
| 41 | Double pole-32 amp |
| 42 | Supplying and fixing of 2X2 PANEL 36 W 6500 K, Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling. driver.cat ref.LHEBAEP7IW1W036 make Havells and its equivalent Crompton Philips etc. |
| 43 | Providing and fixing of full glow 4\" 18/20 Watt Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack Tubelighting fixtureceilling/Wall mounting,,complete with connection, testing etc. as reqd.Make Havells E-LITE LED PRIDE PLUS /Philips/Havells/wipro/bajaj |
| 44 | Providing installation testing and commissioning of ISI marked ceiling fans of 1200 mm sweep, capacitor type with double ball bearing complete with capacitor, 300 mm down rod, canopies,with 1.5 sqmm FR PVC indulsted, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required suitable for single phase, AC 230 Volt, 50Hz supply. Acceptable make- Orient SUMMERKING (XL Aluminium Blades) /crompton/Havells/Usha) |
| 45 | Supplying and fixing of 300 mm sweep,double ball bearing, semi comercial metal ,exhaust fan suitable for single phase, 50 Hz, 230 volts, 900 rpm AC supply in existing hole to suit the size including connections etc. as required. Make Crompton, Havells, Usha, Orient etc. |
| 46 | Supplying & fixing of 50 watt LED street light fitting Presssure Die Cast aluminium with IP66 protection, high efficient output emitter LED for better distribution. energy saving with less weight,envoirement friendlyon existing pole, including wiring with 3 x 1.5 Sqmm (from looping box to LED fitting), PVC insulated & PVC sheathed multi core, copper condoctor cable & making connection of LED flood light fitting etc, make HavellsCG/ Havells / Philips/Orient (Fittings will be warranted for 2 years from the date of installation neccessary certificate in this regard will be provided by the contractor through authorized dealer / stockist from whom it was procured). Including suitable sizes of brackets. |
| 47 | Repair & Rewinding of 05 HP, three phase, Monoblock / submersible motor pump set with suitable size of superior quality poly insulated copper wire of same class,same characteristics as original. After dismantling the old/ burnt copper wire and greasing,testing ( including deducting the cost of old scrapped materials) etc. as required. |
| 48 | Rewinding of 1200 mm ceiling fans motor ( Starting and running winding ) with all necessary materials . The motor is to be wound taking the no. of coil turns and pitch etc. as required as it was originally wound with required size of super enameled copper wire with \"E\" class insulating materilas and making connection etc. as required ( scrap material will be retained by the contractor |
| 49 | Rewinding of exhaust fan motor with all necessary materials . The motor is to be wound taking the no. of turns and pitchetc. As required as it was originally wound with required size of super enameled copper wire with \"E\" class insulation materilas and making connection etc. as required ( scrap material will be retained by the contractor ) i) 380/400mm sweep (Heavy duty) |
| 50 | Replacement of ball bearing including removing & reaffixing in ceiling fans & Exhaust fans an irrespective of size of fans with all accesseries . T&P cost of bearing as required . NBC/SKF make ( scrap material will be retained by the contractor ) |
| 51 | Providing and fixing of LED surface panel ( square/round) along with driver 15 watt 3000/4000/6500 K complete with connection testing as per reqrd. Make Havells/Philips/Crompton /Syska etc |
| 52 | Providing and fixing of heating element (heating rod) for 15/25/35 ltr capacity storage water heater including dismantling the old defective heating element including connection etc as required. |
| 53 | Providing and fixing of thermostat for 15/25/35 ltr capacity storage water heater including dismantling the old defective heating element including connection etc as required. |
| 54 | Providing and fixing of tindicator lights ( red or green) for 15/25/35 ltr capacity storage water heater including dismantling the old defective heating element including connection etc as required. |
| 55 | Supplying, installation of25 Ltrs capcity storage water heater including providing & fixing of connection pipes etc complete as required. Make Racold CDR DLX Havells /Vgaurd/CG/Bajaj/orient/usha/ AO Smith/jaguar as required as per direction of engg in charge. |