| 1 | Taking down chowkats with shutters (without taking off shutters from the frames) n.exc 1.5Sqm complete all as specified. |
| 2 | All as per item No 1 above but exc 1.5Sqmand n.exc 4 Sqm complete all as specified. |
| 3 | Taking down shutters of any descriptionexc 1 sqm and not exc. 2sqm each complete all as specified. . |
| 4 | S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including teak wood lipping complete all as specified. |
| 5 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm PLAIN COLOURED PVC sheet reinforced with MS square tube,to match complete all as specified. |
| 6 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain coloured PVC sheets and 5mm thick x 15mm wide PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of PLAIN COLOURED PVC sheetjoined together with solvent cement supplying & fixing in the frame at site as per specification and drawing complete all as specified. |
| 7 | S&F MS clamps and hold fast and similar small articles confirming to Fe-290 Gde-E-165 complete all as specified. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 9 | Supply and fix fabricated steel staircases (framed type) comprising stringers, treads, landings, balusters, handrails, doors, gates and all associated structural components, fabricated from Fe-410W (Grade E-250, Quality A) steel sections. The work includes providing and fixing cleats, brackets, gussets and all necessary fittings, including cutting, welding, drilling, bolting, aligning, erection and finishing, complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat) and removingrubbish off the MD premises |
| 11 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.and removing debris out side MD land. Note: The place of disposal shall be find out by the contractor. |
| 12 | Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and rubbish off the premises.Note: The place of disposal shall be find out by the contractor. |
| 13 | Material and labour for vitrified ceramic tiles 600 x 600 x 8 to 10 mm of light colour (matt finish/nano finish, double charged), polished/glazed area of each tile in floors set jointed and pointed in epoxy grout to match flooring with and including 20mm cement sand screed in cement mortar 1:6 complete. The joints shall be 2 mm thick and 2 mm thick spacer at every corner shall be used all as specified and directed. |
| 14 | Material and labour for glazed/ polished ceramic tiles in vertical surfaces 600 x 300 x 8 to 10 mm thick (glossy/nano finish, double charged), set and jointed using tile adhesive (3-6 mm thick) and pointed in epoxy grout to match shade of tile including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.Note: both the substrates should be cleaned, spread the adhesive on plastered surface andcomb with a notched trowel and place the tile. |
| 15 | S&F400mm X400mm X 7 to 8mm thick non skid ceramic tile any colour tile set jointed and pointed in coloured cement slurry in flooring with and including 20mm cement sand screed in cement mortar 1:6 completeall as directed |
| 16 | S&F glazed ceramic coloured tiles of size 300x450x 7mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match and including10mm thick backing coat in CM 1:4complete all as specified and as directed by Engineer In Charge |
| 17 | Supply and fix 2 mm thick coloured electrostatic conductive vinyl flooring having optimal and constant static-conductive properties, anti-fungal and anti-bacterial characteristics, laid on properly levelled floors using cementitious self-levelling compound and approved suitable adhesive. Work includes provision of copper strip earthing grid as required, laying over existing tiles where directed, cord welding of joints, and sealing of wall–floor junctions with approved sealing compound, complete all as specified and directed. Make: Armstrong / Favorite / Responsive or equivalent.” |
| 18 | M&L Machine cut mirror polished Kota stone slab flooring 22-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete andincluding20mm thick screed bed in CM(1:6)complete all as specified and as directed by Engineer In Charge |
| 19 | Ditto all as per item No 18 but in riser of steps, skirting, dado and pillar etc including 10mm thick backing coat in CM 1:4 complete as directed |
| 20 | M&L 40mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in flooring finished roughed to receive tiles. |
| 21 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of bricks work or concrete finished even and smooth without using extra cement. |
| 22 | Material and labour for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of acrylic (100 % antifungal interior grade) paint over a coat of primer etc.complete all as specified and directed. |
| 23 | S & F in repair for 8 mm thick gypsum pre-laminated tiles of size 600 mm × 600 mm for false ceiling, fixed on an aluminium anodized snap grid system of module size 605 mm × 605 mm. The system shall include aluminium anodized perimeter angle 20 mm × 20 mm × 1.2 mm fixed to the wall along the ceiling perimeter using nylon sleeves and screws at 610 mm c/c.The framework shall consist of:Main tees 31.75 mm × 31.75 mm × 1.60 mm,Cross tees 25.4 mm × 25.4 mm × 1.22 mm,Ceiling cleats / angle brackets 15 mm × 15 mm × 1.5 mm,all suspended using 6 mm dia. GI wire from the soffit at 1220 mm c/c (maximum suspension length 1200 mm), fixed to the roof slab with 10 mm dia. steel expansion fasteners.Complete all as specified and directed. |
| 24 | Supply and fixin repair plain ceiling system consisting of 600 mm x 600mm tiles (As per IS: 2095-1996: Part I) of pre coated galvanised aluminium in 0.7 mm thickness in required colour to be laid “on Armstrong/Hunter Duoglas grid systems/equivalent make as specified in Appx \"B\" of PS hereinafter with 15 mm wide T - section flanges in required colour having rotary stitching on the 1200 mm & 600 mm cross tees. The grid should be GI of make“Armstrong/Gyproc /equivalent make ”with 15mm wide T - section flanges in required colourshadehaving rotary stitching on all T sections i.e. the main runner, 1200 mm & 600 mm.Tees with a web height of 32 mm.Perimeter trim to be Armstrong/Gyproc/equivalent make as specified in Appx \"B\" of PS hereinafter, wall angles of size 19x19mm, secured to walls at 450 mm maximum centres including necessary fitting and 6 mm GI suspenders fixed to slab using steel fastener in ceiling all as specified and directed. |
| 25 | S & F in repairs 12mm thick plywood grade BWR fixed with screws including fixed with screws/teakwood beading or aluminium beadingto wooden or Aluminium frame worketc.complete all as specified and directed.((New aluminium sections shall be msrd and paid seperately) |
| 26 | S & F in repairs 18/ 19mm thick plywood grade BWR fixed with screws including fixing and polishing teakwood beading 4mm thick to exposed sides, as in cupboards, shutters etc including necessary fixing arrangements as directed by Engineer in Charge. |
| 27 | S&Faluminum anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts etc complete of size 300mm |
| 28 | S&Fin repair aluminum anodoised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts etc complete of size 300mm |
| 29 | M&L for preparation of new wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer all as specified and directed |
| 30 | S&FExtruded aluminium alloy handles, fabricated type., anodised in 150mm size all as specified and directed |
| 31 | S&Fin repair Extruded aluminium alloy handles, fabricated type., anodised in 150 mm sizeall as specified and directed |
| 32 | S&FSS butt hinges medium weight cold rolled stainless steel of size 100mm all as specified and directed |
| 33 | S&F in repairs SS butt hinges medium weight cold rolled stainless steel of size 100 mm all as specified and directed |
| 34 | S&Falumn anodized barrel tower bolt of extruded section & fixed of size 150mm all as specified and directed |
| 35 | S&Fin repair alumn anodized barrel tower bolt of extruded section & fixed of size 150mm all as specified and directed |
| 36 | Taking down old aluminium windows or partition at any description and in any position all as specified and directed |
| 37 | Supply & fixing in repairs powder coated aluminiumsections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such asglazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specifiedNote: - (i) Glass panes will be measured & paid separately. (ii)The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as requiredbut shall not be measured for arriving of weight.(iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.(v)The size of aluminium sections shall be as perHQ CE(N) MZ TD drawing No TD/2021/01 to 05 |
| 38 | S & F sheet glasses,plain4.80mm thickglazingall withaluminum beading, glazing pin etc, or with oil putty in squaren exc .5 sqm in each pane. |
| 39 | Ditto as per item no_38 but all as above but exc 0.5 sqm in each pane. |
| 40 | S&F aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminiumwire staples and beading /U sectionif requires complete all as specified and directed |
| 41 | Material and labour for preparation of old plastered surfaces of wall by washing and rubbing down and stopping of old surfaces and complete removal of existing treatment and applying two coats of acrylic (antifungal) paint interior grade over a coat of primer etc. complete all as specified and directed. |
| 42 | Material and labour for preparation of old plastered surfaces of ceiling by washing and rubbing down and stopping oldsurfaces/painted surfaces and complete removal of existing treatment and applying two coats of acrylic (antifungal) paint over a coat of primer etc.complete all as specified and directed. |
| 43 | Material and labour for preparation of steel and iron work of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint etc.complete all as specified and directed. |
| 44 | Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars, shaft walls, crumple edges and supports for water pipeline carefully including copings etc.and removing debris outside MD land complete all as specified.Note: the work to be carried out in roof of G+6 storey bldg |
| 45 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6)complete all as specified. |
| 46 | M&L brick work with sub class \"B\" old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 including duly reinforced with 10 mm dia MS round bars 2 nos horizontally after each 4 layer of bricks complete all as spd and directed |
| 47 | Taking down CI/PVC soil/waste/vent/rain water pipes laid in trenches or fixed to walls packed in pccincluding concealed rain water pipesincluding all fittings like shoes bends swan necks etc of any dia all as specified and directed. |
| 48 | Supply & Fixing 75mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 75mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 49 | Supply & Fixing 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 50 | M & L cutting holes using core cutter of dia 75 mm to 110 mminto or through cement concrete slab, chajja, parappet etc reinforced cut through of superficial area of appropriate bore including making good after inserting and setting pipe and sealing with epoxy grouting |
| 51 | S & F bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required and similar small articles conforming to Fe 290 Gde E165 for new or old pipes in shaft up to a height of 35 RM including scaffolding |
| 52 | M & L cutting holes in brickwork/ PCC/ RCC using core cutter and providing 40 mm diaPVC pipe as spout of required length and making good with water proofing treatment |
| 53 | S & F in repair 15 mm bore CP bib cock with wall flange, fixed to existing supply line with necessary fittings, complete as specified and directed. |
| 54 | S & F in repair PVC pipe 40 mm dia, concealed, fixed in any position and at any level, joined to drain pipe including connection to existing PVC waste pipe with elbow and tee, including cutting and jointing the existing drain line, complete as directed. |
| 55 | S & F in repair wash hand basin, vitreous china, white, flat-back type, size 630 × 450 mm, including CI brackets, 32 mm CP waste coupling, cutting and pinning in ends of brackets, and connecting supply pipes, waste and taps, complete as specified. |
| 56 | S & F in repair PVC connector 15 mm dia, any length, with CP brass nuts, connected to waste water line 450 mm long, complete as direc |
| 57 | S & F in repair a 15 mm dia CP brass pressmatic / self-closing type pillar tap, heavy-duty, water-saving design, suitable for wash basins and similar sanitary fixtures. The tap shall be cast brass, chromium plated (CP), with integrated self-closing mechanism, preset opening time, and smooth operation. |
| 58 | Supply and fixing/laying of CPVC Pipes SDR 11 and plain CPVC SDR 11 fittings of 16 mm dia including cutting pinning and connecting to supply line duly concealed ceiling /or laying in floor, complete all as specified. |
| 59 | S&F 15 mm bore stop valve cast copper alloy, chromium plated, fancy type with long shank screwed down high pressure concealed typescrewed both ends for ipipes or union complete all as specified. |
| 60 | Supply and fix in repair PVC waste pipe 32mm bore, 90cm long fixed with waste coupling including socket complete all as specified and directed. |
| 61 | Taking down shutters of any description exceeding 1 sqm and not exceeding 2 sqm, and refixing in the same opening after repairs, including replacement of damaged sections.Note: Replaced aluminium sections shall be measured and paid separately. |
| 62 | Taking down shutters of any description exceeding 2 sqm, and refixing in the same opening after repairs, including replacement of damaged sections.Note: Replaced aluminium sections shall be measured and paid separately. |
| 63 | S & F aluminium anodised sections of various sizes for frames and shutters of doors, windows, ventilators and partitions, with one or more rebates, including joining cleats, glazing clips, beading, rubber packing, screws, and all other required fittings including locking arrangements, complete as specified and directed by the Engineer-in-Charge.Notes:(i) Glazing / wire mesh shall be measured and paid separately.(ii) Item shall be paid as per weight of aluminium sections; however, the rate quoted shall be inclusive of neoprene beading, glazing pins, screws, handles, etc., which shall not be measured for arriving at weight. |
| 64 | S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including teak wood lipping |
| 65 | Supply and fix in repair 8 mm thick 600x600mm size gypsum pre laminated tiles on false ceiling (As per IS : 2095-1996: Part I) suitable for existing anodised aluminium frame of existing pattern and suitable for opening in the ceiling grid including 4 mm dia.G.I.wire suspended from the soffit at 1220 mm centres (upto 1200 mm length maximum) fixed to roof slabs by means of 12 mm diafancy type steel anchor fastner hook 80 mm long complete all as specified and directed |
| 66 | S&F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.make: hyper, hardwyn of model as per site requirement |
| 67 | S&Faluminum anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts etc complete of size 300mm |
| 68 | M & L0.9 mm decorative laminate type 1 of surface finish , colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instruction |
| 69 | Supply and fix in repair 12 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws/aluminium beadingto Aluminium frame worketc.complete all as specified and directed.((New aluminium sections shall be msrd and paid seperately) |
| 70 | Material and labour for cleaning and preparation of new wooden surfaces of any description, width or girth and applying two coats of french polish over a coat of wood filleron new work with two o more coats etc. complete all as specified and directed |
| 71 | S & F stainless steel handle, 100 mm long, complete all as specified and directed. |
| 72 | S & F stainless steel clip-on hinges, size 100 × 12 mm, flap-open type, complete with all fittings as specified and directed. |
| 73 | S & F stainless steel hasp and staple, 75 mm, complete all as specified and directed. |
| 74 | Fixing cupboard to plastered brick or concrete surfaces using necessary anchors, fasteners, nuts, bolts, etc., including all connected fittings, complete as specified and directed. |
| 75 | Hacking out old broken glass (any thickness size, quality or description) from wooden frames ,glass doors , Partition or glazedwith putty or fixed with beads |
| 76 | S & F sheet glass, opaque/frosted on one side, 4.80 to 5.00 mm thick, fixed with aluminium beading and glazing pins or with oil putty, in panes exceeding 0.5 sqm, complete as specified and directed. |
| 77 | Ditto— all as per Item 76.00 but in panes not exceeding 0.5 sqm each. |
| 78 | S & F aluminium anodised barrel tower bolt, extruded section, 100 mm size, fixed complete as specified and directed |
| 79 | S & F in repair aluminium anodised barrel tower bolt, extruded section, 100 mm size, fixed complete as specified and directed |
| 80 | S&F 140 mm overall length floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor all complete as specified and as directed by Engr-in-Charge. |
| 81 | S&F in repair 140 mm overall length floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor all complete as specified and as directed by Engr-in-Charge. |
| 82 | S & F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40mm and fixed with almn wire staples and rubber beading /U sectionif requires including taking down old windows and refixing in same position complete all as specified and directed |
| 83 | M&L for providing 25 mm thick soft rubber mat of approved colour with or without interlocking and fixed on existing floor using adhesive as recommended by manufacturer |
| 84 | S&F glass door assembly 12 mm thicktoughenedglassfor glass door,double shutter including SS pivot of floor door closer at top and bottom SS corner support SS handle 600 mm long fixed at both sides of both shutter andincluding all SS fittings and lock assemblyas required superior quality complete all as specified and directed by Engr-in-charge |
| 85 | Taking down aluminium sections and refixing in the same opening for fixing high density polymer extruded mesh including all necessary fitting fixtures etc(New aluminium sections shall be msrd and paid seperately) |
| 86 | S&F in repairs high density polymer extruded mesh coloured 2.0mm thick mesh and 32 mm average aperture for bird protection all as specified and directed |
| 87 | S & F in repair aluminium anodised DECO grill, type DG-104, fixed with necessary U / F / H channels, including taking down and refixing the window, complete all as specified and directed by the Engineer-in-Charge. |
| 88 | S&F 10 mm thicktoughenedglass as in partition, doors and similar works including cutting to shape drilling holes requiredcomplete all as specified and directed by Engr-in-charge |
| 89 | M&L for 10 mm thickinterlocking laminated wooden flooring on 2 mm thick foam sheets/adhesive as per manufacturer instruction of branded manufacturesincluding proper levellingof base shall be done before laying including filling holes withcement plaster in CM (1:3) to made for true level. including skirting complete all as specified and directed by Engr-in-charge.Note : The colour and pattern of tile should be approved by Engr-in-charge. |
| 90 | S&F in repairs solar control film 50 micron reflective type sticked to glass panes icluding cleaning the glass as per instructions of manufacturers |