| 1 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. |
| 2 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screwscomplete all as specified and as directed. |
| 3 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specifiedcomplete all as specified and as directed. Note:To be executed for provision of ridges and hips. |
| 4 | S & F false ceiling with exposed metal (PPGI) framework/Tee Grid providing and fixing of suspended Tee gird false ceiling using T Grid system- Powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x .3mm thick, cross tee 26mm x 24mm x .3mm thick and wall angle 24mm x 24mm x .40mm thick using 4mm thick non asbestos fibre cement board (Make :- Everest, type/pattern - Oceanic or equivalent of Armstong/Charminar) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high pressure system Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, conforming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part-3 & B. S -476 part 4,5,6,7 & 8 should be placed in Grid module for form after and including dismantling of existing false ceiling of any type complete all as specifiedand as directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 6 | S&F Rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-w (Gde-E250) quality Aall as specified and directed. |
| 7 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 8 | F&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded completed all as specified and directed. |
| 9 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 10 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 11 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed. |
| 12 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/paving, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed. |
| 13 | M & L for PCC 1:2:4,type B-1(using 20 mm graded crushed stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed. |
| 14 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 15 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in Roof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and as directed. |
| 16 | M&L for RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc. complete all as specified and as directed. |
| 17 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja,floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 18 | M & L for mild steelTMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 19 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 20 | M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 21 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound @ 100Mlper bag(50Kg) of cement or as per manufacture\"s instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as \"Supply only\". |
| 22 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 23 | M&L for preparation of newly plastered surfaces of wallsand applying one coat of alkali resistant primer over a coat of 3 mm thick (average) white cement putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distempercomplete all specified and as directed. |
| 24 | M&Lfor complete removal of existing finishes/treatment of wall and applying two coat ofoil bound distemper over one coat of primer including 3 mm thick(average) wall care putty complete all as specified and as directe. |
| 25 | M&L for preparation of newly plastered surfaces of wallsand applying two coat of antifungal emulsion exterior weather proof paint complete all specified and as directed |
| 26 | M&L for complete removal of existing finishes/treatment of wall and applying two coats of antifungal emulsion exterior weather proof paint complete all specified and as directed. |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed. |
| 28 | M & L for colouredjoint free non-skidceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc.over and including 15 mm thick screed bedin cement motar 1:6, setand jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles,complete all as specified and as directed. |
| 29 | M&L for coloured joint free non skid ceramictiles 7 to 8mm thick (square / rectangular) area of each tiles exc 0.11 sqm but not exceeding 0.18 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with colouredtilesover and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 30 | Taking down chowkats orframe with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed. |
| 31 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqmeach (without taking off shutters from frame) complete all as specified anddirected. |
| 32 | M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints complete all as specified and as directed. |
| 33 | M&L formild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 34 | M&L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 35 | S & F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 36 | S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etcwith plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified anddirected. |
| 37 | M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 38 | S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 39 | S&F 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 40 | S&F 150mmsize aluminium handles, cast type, anodised complete all as specified and as directed. |
| 41 | S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed. |
| 42 | S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 43 | S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 44 | S & F in Repairs, 25mm aluminium powder coated curtain rod including funnels etc complete all as specified and as directed. |
| 45 | S&F in repairs, anodised aluminium brackets for 25mm dia curtain rod complete all as specified and as directed. |
| 46 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 47 | M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in and including PVC conduitwith cable 1.5 Sqmm size 1100 volts grade conforming to IS:694 and terminate to flush box of required size suitable mounting modular switches and sockets including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire connected to earth and common earth dollydrawn in same concealed conduit for one light/fan/wall fan/exhaust fan/bellpoint controlled by one No, one way 5/6/10 Amp switch complete all as specified and as directed.Note: Cutting chases for concealed type point wiring including making good the same with plaster/putty and Modular boxes with cover plate is deemed to beincluded in quoted rate. |
| 48 | Allas per item serial No 47 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 49 | Allas per item serial No 47here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 50 | All as per item serial No 47 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 51 | Allas per item serial No 50here-in-before butfor One 6 pin 16/20 Amp switch socket outlet on same board with other switches. |
| 52 | S&F Modular switch 1 way 6A/10A, 1 module, single pole one way 240 volts complete all as specified and as directed. |
| 53 | S&F Modular switch 1 way 16A/20A, 1 modulesingle pole one way 240 volts complete all as specified and as directed. |
| 54 | S&F Modular type socket shuttered type, 6A/10A, 2/3 Pin combined 2 module,240V,ACISI Marked complete all as specified and as directed. |
| 55 | S&FModular socket shuttered type, 6/16A or 10/20Amp, 6 pin combined 2 module complete all as specified and as directed. |
| 56 | S & F red color lighting indication lamp 6 Amps, single pole,240volts, AC,50 Hz suitable for 1 module ISI Marked Complete all as specified and as directed. |
| 57 | S&F Modular stepped type electronic fan regulator, two module size, flush typecomplete all as specified and as directed. |
| 58 | S&F lamp holder, insulated, PVC / polycarbonate /bakelite body including 10W LED bulb complete all as specified and as directed. |
| 59 | S&F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 60 | S&F in repairs,decorative box type 20-watt light fitting, blue coloured end caps, pre-wired, and including providing PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling roseand including LED T-8 tubular lamp of 20 Watt extruded aluminium/PC body and PC diffuser complete with inbuilt LED driver complete all as specified and as directed. Make of light fitting: Crompton Model No.DMLN1LT8-16/Havells Model REGALBATTENT8UPTO1X22WSSBSWH/Bajaj Model No BLRB-DB 218 or equivalent make in PhilipsMake of LED Rod Crompton Model No.LT8-20-865-2 / Havells Code No.PHOTONULTRA1213T8SSTL20WLED865SPC/Bajaj Model No BLRB20CW LED or equivalent make in Philips |
| 61 | Taking down carefully by unscrewing, dismantling, and disconnecting all electric connection from SPN DB of 4 way in any height or a place to be kept in safe custody and refixing the same to its own position after cleaning dust particles and connections to be checked complete all as specified and as directed. |
| 62 | S&F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make :- Legrand Cat No 5076 11 orL&K Cat No DESPN008DDS or equivalent model in Siemens / Schneider/Havells. |
| 63 | S&FMCBs, SPN 40 to 63 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 64 | S&FMCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 65 | Taking down carefully ceiling fan 1200/1400 mm and exhaust fan of any make & capacityfrom any heightoverhauling of fan motor of any size and removing unserviceable grease, bearings, bushes, split pin, nuts and bolts and cleaning with petrol/kerosene applying new grease and reassembling complete including replacement of wornout spares with new like split pin, nut & bolts and material and labour for painting to ceiling fan complete body, blades & down rod etc of any sweep/make/model with two coat of synthetic enamel paint(Duco)by using electric spray machine similar to match with existing colour after preparation surfaceswith black paint complete and refixing the same to its original position and proper electric connection to be made and all as specified and directed. Note:- Painting work to be carried out after dismantling of ceiling fan |
| 66 | M&L for Sub main wiring with 2 runs of 4 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 67 | M&L for Sub main wiring with 2 runs of 6 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 68 | M&L for Sub main wiring with 2 runs of 10 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 10 Sqmm cable and 1 run of 10 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 69 | M & Lfor earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cm X 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including dismantling of old earthing complete all as specified and as directed. |
| 70 | S&F in repairs,LED building security luminaries 35 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. |
| 71 | S & F security lightbracket made out of GI pipe 32mm dia medium grade (bent to shape as directed ), 1.2 M long, fixed with MS flat iron clamps made out of 30 mm x 6 mmwith nuts, bolts, washers and other connected items of required size, suitable for steel tubular poles/wall and painting with one coat of aluminium paint over a coat of red oxide zinc chrome primer including taking down old bracket complete all as specified and as directed. |