| 1 | Demolition of Mud in roofs, any thickness including plastering and leeping,(whether full thickness removed etc complete all as specified. |
| 2 | Demolition Bricks (laid flat or on edge) or brick tiles in laid beddedin any mortar on floors, channels,kerbs, aprons, etc. (each layer) complete all as specified. |
| 3 | M&L for 40 mm thick PCC (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in roof padding, sub base of floor copingcomplete all as specified and directed. |
| 4 | M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified.Notes : WPC shall be measured and paid seperately. |
| 5 | M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm followed by a tack coat @ 1.2 kg per sqm using 85/25 grade industrial hot blow bitumen over it laid with APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm as per manufacturer\"s instructions complete all as specified. |
| 6 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 7 | M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed. |
| 8 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4)for laying floor finishescomplete all as specified and as directed. |
| 9 | M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machinepressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments complete all as specified. |
| 10 | M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in CM 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto doublestorey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified. |
| 11 | M&L for mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified. |
| 12 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified. |
| 13 | M&Lfor 5 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling includingfinishingsurface even and smooth without using extra cement. |
| 14 | M&L for 10 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls includingfinishingsurface even and smooth without using extra cement |
| 15 | M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified. |
| 16 | M&L for preparation ofnewly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified. |
| 17 | M&L for preparation ofnewly plastered or unplastered/undecorated surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified |
| 18 | M&L for preparation ofnewly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified |
| 19 | S&F in repair false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \"Armstrong\"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceillingcomplete all as per manufacturer’s instructions and as directed. |
| 20 | Taking downchowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified. |
| 21 | All as per item No.20 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified. |
| 22 | Taking down chowkhats or frames not exc. 1.5 sq. m each complete all as specified. |
| 23 | All as per item No.22 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified. |
| 24 | Taking down shutter of any description exc 1 Sqmand n exc 2 Sqm and removing from site. |
| 25 | Taking down shutter of any description exc 1 Sqmand n exc 2 Sqm but refixing in same opening complete all as specified. |
| 26 | S&F forPressed steel frames 125X60mm (made out of 1.25 mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified. |
| 27 | S&F forPressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified. |
| 28 | S&F factory made 35 mm thickflush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified. |
| 29 | S&F factory made 35mm thick 2nd class hardwood plain framed, panneled shutters with lock rail and pannel of 9 mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rails and stiles as per IS-1003 (Part-1) Kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 30 | S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified. |
| 31 | S&F solidPVC door frame of size 50 mm X47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing. |
| 32 | S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheetfor top rail, lock railand bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing as specified. |
| 33 | S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified. |
| 34 | S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified. |
| 35 | S&F 150 mm size extruded aluminium alloy handles fabricatedtype anodised and fixed. |
| 36 | S&F 250 mm long aluminium alloyanodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed. |
| 37 | M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 38 | M&L for prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paintcomplete all as specified |
| 39 | Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified. |
| 40 | S&F powder coated anodized aluminum frame for partition, doors, windows ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 41 | S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium anodized handles suitable size 2 Nos in each door,100 mm longaluminum anodized hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified. |
| 42 | S&F powder coated Anodised aluminium window and ventilator shutters side hung type without sash bar, aluminium sections weighing 0.55 kg/m including necessary joining, cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as hinges type B-21 100 mm long (2 Nos) suitable handle 1 No complete all as specified. |
| 43 | Repairs to Aluminium Doors including taking down the shutter n. exc 2.00 Sqm each for repairs including replacement of defective parts of frame/shutters ie cleats, angle, screw, clips, gasket, rubber beadings, channels etc and refixing in the same opening complete all as specified and directed. (Note : certain builders hardware such as door closer, floor spring, door stopper, tower bolts, sliding bolt and handle, mortice lock and glass if replaced will be paid separetely in respective items) |
| 44 | S&Ffor 5.50 mm thick sheet glass ordinary quality and glazingeach pane fixed with neoprenerubber gasket in aluminium frame work complete all as specified. |
| 45 | S&F sheet glass 4mm thick ordinary quality and glazing each fixed with neoprenerubber gasket in aluminium frame work complete all as specified. |
| 46 | S&F 9 mm thick prelaminated particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified. |
| 47 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixingapproved anodised aluminium standard section around theopening, all complete as per requirement and direction of Engineer in-charge. |
| 48 | S&FStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified. |
| 49 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified. |
| 50 | S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified. |
| 51 | S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified. |
| 52 | S&F as in repair 150 mm double actiondoor spring hinges, brass, with phosphor bronze wire spring, bright polished complete all as specified. |
| 53 | S&F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified. |
| 54 | S&F in repair 150 mm (Overall length of cover plate) Floor door stopper of brass body and tongue with hard drawn steel spring, fixed in floor complete all as specified. |
| 55 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed. |
| 56 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified. |
| 57 | Dismantling mild steel work of any description not otherwise provided for complete all as specified. |
| 58 | S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified. |
| 59 | S&F framed work such as grills gratings, etc with ends of bar shouldered and/or revited or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters, walk ways, railings framework of water tanka and similar works confirming to Fe 290 Gde E-165 complete all as specified |
| 60 | S&F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified. |
| 61 | S&F steel work as in tubular, rafters, purlins, posts and similar work(round/sqare/rectangular shape of pipes as approved by Engr-in-charge ) trusses of semi circle/ curved shape up to height 6 mtrincluding postspecial shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 garde St-240 complete all as specified. |
| 62 | Taking up or down15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. |
| 63 | Taking up or down20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. |
| 64 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthin brick wall etc complete all as specified. |
| 65 | M&L for 15 mm bore steel water tubing medium grade (ISI marked) galvanised with and including all tube fittings (ISI marked) concealed or fixed to wall, ceiling or laid in floors complete all as specified. |
| 66 | M&L for 20 mm bore steel water tubing medium grade (ISI marked) galvanised with and including all tube fittings (ISI marked) concealed or fixed to wall, ceiling or laid in floors complete all as specified. |
| 67 | S&F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 68 | S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified. |
| 69 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore. |
| 70 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore. |
| 71 | S&F in repair PVC (SWR) bends any radius 110mm bore. |
| 72 | S&F in repair PVC (SWR) bends any radius 75mm bore. |
| 73 | S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified. |
| 74 | S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified. |
| 75 | S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall. |
| 76 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 77 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin sub base of flooring etc complete all as specified. |
| 78 | M&Lfor Providing 100 mm thickPCC (cement concrete) 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates)as in hardstanding/ ramp/pathetc Spike rolling to surfaces or making impressions of expandedmetal,whilst the concrete is greenComplete all as specified and directed |
| 79 | M&L Forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade \"A\". Complete all as speicified and as directed |
| 80 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping , kerb, benching, gola and similar items all as specified and as directed |
| 81 | M&L for Sand filling in floors including levelling, watering and consolidation, complete all as specified and directed |
| 82 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and No pigment with designed pattern, complete all as specified and directed |
| 83 | M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6for laying floor finishescomplete all as specified. |
| 84 | M&L chequered cement concrete coloured tiles 30cmx30 cmx25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified. |
| 85 | Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified. |
| 86 | Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified. |
| 87 | Supply only intergral water proofing compound ISI Marked complete all as specified. |