| 1 | Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified. |
| 2 | M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement, complete all as specified. |
| 3 | M&L for 10 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls includingfinishingsurface even and smooth without using extra cement , complete all as specified |
| 4 | M&Lfor 5 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling includingfinishingsurface even and smooth without using extra cement.complete all as specified |
| 5 | M&L for rough cast plaster on brick walls consisting under coat of cement and cement and sand mortar 1:3 not less than 10 mm thick and while it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed of size 6 mm with coarsesand and cement in the ratio 1:1:1 shall be applied and finish even including necessary grooving complete all as specified and directed |
| 6 | M&L for preparation ofnewly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified. |
| 7 | M&L for preparation ofnewly plastered or unplastered/undecorated surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified |
| 8 | M&L Preparing of new surface of wall and applying twocoatsofexterior emulsion paint over a coat primer on walls complete all as specified and directed by Engineer-in-charge. complete all as specified and as directed by Engineer-in-Charge . |
| 9 | Preparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of oil bound distemper, complete all as specified and directed by the Engineer-in-Charge. |
| 10 | M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with puttyand applying one coat of distemper oil emulsion on ceiling complete . |
| 11 | M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling of holes and cracks with with suitable material like cement or plaster of paris etcand thereafter applying two coat of oil bound distemper on walls.Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. |
| 12 | All as per item No.11 here-in-before but on surfaces of ceiling. |
| 13 | Material and labour for preparation of old painted surfaces of steel of any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as directed.Make of Paint : Asian(Apcolite)/ Nerolac (Goodlass)/ Berger paints/ICI Dulux |
| 14 | Material and labour for preparation of old painted surfaces of wood and wood basedof any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as directed. Make of Paint : Asian(Apcolite)/ Nerolac (Goodlass)/ Berger paints/ICI Dulux |
| 15 | M&L for preparation of old treated plastered or unplastered surfaces of walls/ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with puttyand applying one coat of wheather proofing exterior acrylic emulsion paint on walls complete . Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. |
| 16 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over priming coat premium quality on wall/ceiling surface including applying 2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. |
| 17 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, etc completed all as specified. |
| 18 | Demolition of stone slabs and tiles of any description or thickness in floors , aprons etc , laid bedded and pointed in any mortar , et complete all as spd and directed |
| 19 | M & L for 25mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed. |
| 20 | M&L Coloured Glazed ceramic tiles in vertical surface 450X300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchincluding Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat. |
| 21 | M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortarfor laying floor finishes in CM 1:6 |
| 22 | M&L 7 mm to 8 mmthickJoint less light ceramic tiles Ditto but in Dado/Skirting including Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat. complete all as specified and directed by Engineer-in-Charge. |
| 23 | M & L for light shade , Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 20 mm thick Screed bed or bedding layer of mortarfor laying floor finishes in CM 1:6 etc completed all as specified. |
| 24 | M&L 9mm to 10mmthickJoint less vitrified tiles Ditto but in Dado/Skirting including Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat. of10 mm thick cement rendering in CM 1: 4 complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortarfor laying floor finishes in CM 1:6 |
| 26 | M&L formachine cut kota stone slab flooring 20-25 mm thick over screed bed or bedding layer 20 mm thickin CM1:6, and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing & polishing complete. |
| 27 | M&LKota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 13014 including backing coat 10mm thick in CM 1:4 . |
| 28 | M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including 20mm thick screed bed in CM (1:6) for laying of Granite slab&pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 29 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge |
| 30 | Taking down, Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame),etc complete all as spd and directed. |
| 31 | Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and removing from site all as specified. |
| 32 | S & F for flush shutters , solid core construction , with block board core and plywood face panels , commercial type on both sides , thickness 30 mm , etc complete all as spd and directed |
| 33 | S & F 30 mm, Ist class soft wood factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all as spd and directed. |
| 34 | S&F100 mm size butt hinges, medium weight, cold rolled, mild steel complete all as specified and as directed by Engineer-in-Charge. |
| 35 | 150 mm long aluminium anodized barrel tower boltsof extruded section complete . |
| 36 | 125 mm size, aluminium anodized handles, cast type complete all as specified and directed by Engineer-In-Charge. |
| 37 | 300 mm long MS sliding door bolt, plate type with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete |
| 38 | S & F 300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed by engineer incharge |
| 39 | S & F floor door stopperof aluminium alloy body 140 mm cover plate and tounge , anodized with hard drawnsteel spring fixed in repairs |
| 40 | Preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat ofpink primer complete all as specified and directed by Engineer-In-Charge. |
| 41 | Taking down 20 mm dia GI steel tubing and connection, including cleaning for refixing or removal, completed all as specified and directed. |
| 42 | Taking down 15 mm dia GI steel tubing and connection, including cleaning for refixing or removal, completed all as specified and directed. |
| 43 | S&F GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors 15mm bore complete all as specified and directed. |
| 44 | M & L tubes 20 mm bore dia, medium grade, galvanised, with allfitting and fixed complete to walls and ceilings or laid in floos,complete all as specified and directed. |
| 45 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as directed by EIC. |
| 46 | M&L for brick work with sub class ‘B’ bricks straight or curvedon plan exc 6m mean radius builtin cement mortar 1:6 |
| 47 | Supply and fixing IN REPAIR Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including makingconnections and fixed in position complete in all respect complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F in repair kitchen plate rack stainless steel 1 mm thick of size 60cmx75cm complete fixed to brick/concrete wall, with screw including rawl plugcomplete all as specified and as directed |
| 49 | Dismantling water tanks exc 500 & n exc 1000 and removing to store,etc completed all as spd and directed. |
| 50 | S&F 500 ltrsrotational moulded polyethylene water storage tanks (cylindrical verical with closed top) hoisted and fixed in position including ball valve of 20 mm dia complete all as specifed and directed. |
| 51 | S & F for Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed,Bore dia of pipe in 20 mm, etc complete all as specifed and directed. |
| 52 | S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed by Engr in Charge. |
| 53 | S&F 1000 ltrsrotational moulded polyethylene water storage tanks (cylindrical verical with closed top) hoisted and fixed in positioncomplete all as specifed and directed. |
| 54 | Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified. |
| 55 | M & L for 75 mm thick, Cement concrete type D-2, 1:4:8 (40mm graded aggregate), etc completed all as specified. |
| 56 | Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including necessary formwork completeall as specified. |
| 57 | Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved, design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand. |
| 58 | M&L for 75mm thick cement concrete1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer 50mm thick finished even and smooth without using extra cement. |
| 59 | Chequered cement concrete tiles 30cm x 30cm x 25mm thick in floors / path set,jointed & pointed in neat cement slurry using grey cement and no pigment laid over and including 15mm thick screed bed in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified. |
| 60 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approveddesign & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand. |
| 61 | S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 62 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sectionsweighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 63 | S&F Powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 64 | S&Ffor 4.8/5.0 mm thick sheet glass ordinary quality and glazingeach pane n exc 0.50 Sqm fixed with neoprenerubber gasket in aluminium frame work complete all as specified. |
| 65 | S & F IN REPAIR Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staple. |
| 66 | Dismantling Asbestos cement sheets (corrugated ,semi corrugated etc) in roof coverings incl ridges etc complete. |
| 67 | M&L for Pre-painted galvatume aluminum zinc coating GI based corrugatedsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsallas specified and as directed. |
| 68 | Dismantling boarding of any description , fixed in any posititon with nails , complete all as specified and directed |
| 69 | S&F 18 mm thick 100 % solid WPC (Wood polymer composit) plain board( minimum density 650 kg/cum ) fixed with screws , solvent cement/adhesive to make kitchen cabinet sides , top & bottom shelves inside the cabinets . Complete all as specified and directed .Note:- Material testing certificate (MTC) and authentication of the product shall be mandatory to the manufacturing company |
| 70 | S&F 18 mm thick 100 % solid WPC (Wood polymer composit) plain board( minimum density 650 kg/cum ) of one side prelam/ rigidlam and the other side balancing laminate colour to make the kitchen cabinet shutter/ drawer front shutter . Complete all as specified and directed .Note:- Material testing certificate (MTC) and authentication of the product shall be mandatory to the manufacturing company |
| 71 | S&F 12 mm thick 100 % solid WPC (Wood polymer composit) plain board( minimum density 650 kg/cum ) fixed with screws , solvent cement/adhesive to make kitchen cabinet back and pull out drawer sides . Complete all as specified and directed .Note:- Material testing certificate (MTC) and authentication of the product shall be mandatory to the manufacturing company |
| 72 | S&F 20 mm wide and 1 mm thick PVC edge beading of PVC pasted on edges with suitable adhesive Complete all as specified |
| 73 | Supply & fixing of auto closing hinges openable at 0 degree for kitchen cabinet shutters make; (Hettich,Ebco,prime) |
| 74 | S&F for stainless steel handles 100 mm size for kitchen cabinet / cupboard shutters. Complene |
| 75 | Sheet glass of ordinary quantity 3mm thick and glazing with oil putty in squaresnot exc 1.00 Sqmin each pane including hacking out the glass. complete all as specified and directed by Engineer-In-Charge. |
| 76 | Material and labour for roof treatment as follows:- (a) Applying one coat of SBR latex based bond coat using Latex Plus of Berger or equivalent after mixing with water and cement in ratio of 1:4:7 to improve the bonding between residual and PU coat. Allow to dry bond coat for 4-6 hours before applying PU coat and surface to be cleaned before applying PU coat (b) Applying two coats of single component, cold applied, water based polyurethane modified acrylic dispersion with highly elastic and UV resistant water proofing treatment to the roof with HS PU Roofkoat of Berger or Equivalent at 0.6 kg/per Sqm for each coat without dilutionconfirming to ASTM D 6083-97a (Standard Specification for Liquid Applied Acrylic Coating used In Roofing)Each coat should allow to dry 4-6 hours and sandwiching 40gsm Geo-textile between two coats. Spread 40gsm Geo textile over 1st coat when coat is wet conditionThe component shall have a density of 1.25 to 1.3kg/per Litre, having tensile strentgh of 1.5N/mm2, having elongation of 350% with solid content not less than 60% in 2 coats . SRI value should be more than 100. the quoted rate shallinclude surface prepartion,repair the crack in mother slab by chasing with cutting machine and fill the same with polymerized mortar in CM 1:4 admixed with latex agent of reputed manufacture, making coving at Junction, bore packing, treatment of construction joints completely as per manufacurer\"s specification and direction of the Engineer In Charge.Make: Berger or EquivalentNOTE:- The above treatment shall be got carried out by the authorised applicator of the manufacturer approved by the GE |