| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. |
| 2 | Taking down old U/S main switches, Sheet metal enclosures DB including MCCBs, MCBs etc including making good to the disturbed surface of wall all as directed. |
| 3 | Taking down old unsv T/L of any size and capacity all as directed. |
| 4 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 5 | M&L for Point wiring with 1.5 Sqmm (nominal area) PVC (FRLSH) insulated sheathed copper stranded conductor cable run in and including on surface of wall/ celling/ floor ,PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable sizeincluding 1.5 Sqmm PVC (FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets, fan regulators etc for one light/ fan/ call bell point controlled by one 1- way switch, complete all as specified & as directed by Engineer-in-Charge. |
| 6 | All as per item No 5 above but for One 5 Amps socket point on same board / below board with other switches. |
| 7 | All as per item No 5 above but for One 5 Amps switch socket on independent board. |
| 8 | M&L for Point wiring with 1.5 Sqmm (nominal area) PVC(FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable sizeincluding 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. |
| 9 | One light point controlled by one, one way 6 Amp modular switch. |
| 10 | One fan/ exhaust fan point controlled by one, one way 6 Amp modular switch. |
| 11 | One 5 pin 5/ 6 Amps socket outlet point on the same board. |
| 12 | One 5 pin 5/ 6 Amps socket outlet point on the independent board. |
| 13 | One bell point controlled by one, one way 6 Amp modular switch. |
| 14 | All as per item No 8 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated cable 1100 Volt grade ISI-694 markedfor 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly. |
| 15 | Supply and fix modular switch 1 way 6A, 1 Module |
| 16 | Supply and fix modular switch 1 way 16A, 1 Module with indicator lamp |
| 17 | Supply and fix modular socket 6A, 2/3 pin combined 2 Module |
| 18 | Supply and fix modular socket 6A/16A-2/3 pin combined 2 Module |
| 19 | Supply and fix modular fan regulators2 module 120W . |
| 20 | S & F sub main wiring with PVC insulated unsheated FRLSH cable 1100 Volt grade, with multi stranded copper conducter drawing in and including rigid PVC conduit of size not less than 25mm dia in concealed / surface as required at site including one run PVC insulated unsheated cable with multi stranded copper conducter colour code as a earth continuity and connected upto DB including taking down old unsvv submain wiring of following sizes complete all as specified and directed.Make of wire: Havells/ Polycab/ RR KableMake of conduit: Finolex/ Polycab/ AKG Note: (1) Two/ four run of single core PVC cable with one run of earth conducter & condiut shall be measured as one unit. (2)The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. |
| 21 | 2 x 10 Sqmm + 1 x 10 Sqmm |
| 22 | 2 x 6 Sqmm + 1 x 6 Sqmm |
| 23 | 2 x 4 Sqmm + 1 x 4 Sqmm |
| 24 | 4 x 16 Sqmm + 1 x 10 Sqmm |
| 25 | 2 x 2.5 Sqmm + 1 x 2.5 Sqmm |
| 26 | 2 x 1.5 Sqmm + 1 x 1.5 Sqmm |
| 27 | S&F fitting/fixture in repairs including taking down old unsv fitting/fixture of following specification:- |
| 28 | Supply and fix in repair Modular switchone way 6 Amp,1 Module. |
| 29 | Supply and fix in repair Modular switchone way 16 Amp, 1 Module. |
| 30 | Supply and fix in repair Switch piano flush type single pole one way 16 Amp. |
| 31 | Supply and fix in repair Bell push flush type 5 Amps. |
| 32 | Supply and fix in repair Modular bell push 6 Amp,1 Module. |
| 33 | Supply and fix in repair Modular Fan regulator electronic step type 230 V, 2 Module. |
| 34 | Supply and fix in repair Fan regulator electronic step flush type 230 V, 120W. |
| 35 | Supply and fix in repair Ding DongAC 230 Volts single pole. |
| 36 | Supply and fix in repair Socket out let 2 in 1, 5 pin 5 Amps flush type. |
| 37 | Supply and fix in repair Socket out let 2 in 1, 3 pin 5 and 15 Amps flush type. |
| 38 | Supply and fix in repair Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type. |
| 39 | Supply and fix in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type. |
| 40 | Supply and fix in repair Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module. |
| 41 | Supply and fix in repair Modular Socket outlet 6 Amps 2/3 pin combined 2 module. |
| 42 | Supply and fix in repair Lamp holder PVC/polycarbonate insulated body with back plate suitable for batten fittings. |
| 43 | Supply and fix in repair Lamp holder PVC/ polycarbonate insulated body with cord grip cap suitable for pendent fittings. |
| 44 | Supply and fix in repair Ceiling rose surface type, PVC/ Polycarbonate isloted body size50 x 28 mm three terminals. |
| 45 | S & F LED tube;ight batten fitting 20/22 Watt of aluminium housing suitable for fixing on walls/ceiling, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge.Make: BRIGHT LINEA of Crompton/LUMILINE PLUS NEO of Havells/ Essential SmartBright Batten of Phillips |
| 46 | S & F Flood light fitting 50 Watt made up of pressure die cast aluminium housing with toughend glass with SMD LEDs and with IP66 protection.System efficacy 120 Lm/W. suitable for walls, warm/natural/cool white as per requirement at site comlete all as specified and directed by Engr-In-Charge. Make: ROVER of Crompton/JETA QUANTO PLUS of Havells/Uniflood of Phillips. |
| 47 | S&F LED tubelight batten fitting 10/12 Watt made of aluminium housing suitable for fixing on walls/ceoling including connections, warm/ natural/ cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make:Trim Linea Neu of Crompton/ SmartBright of Philips/ ENDURA LINEAR NEO of Havells. |
| 48 | Supplying, fixing &testing LED 36 Watts, 2\" x2\" POLARIS NIO I - IIrecessed ceiling light fitting, warm/ natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.Make- POLARIS NIO I-II of Crompton/ VENUS NEO 2 x 2 of Havells/ SmartGlow of Philips as approved. |
| 49 | Supplying, fixing & testing LED 34/ 36 Watts,2\" x 2\" POLARIS NIO- III surface mounted ceiling light fitting, warm/ natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.Make- POLARIS NIO III LCTLSNE- 36 - FO- CDL Crompton/ PLUTO PANEL (SURFACE) of Havells or equipment in Philips as approved. |
| 50 | Suppling, fixing & testing LED 15/ 18 WattPEARL NIOS IS A surface mounted LED Panel in round/ square ceiling light fitting, warm/ natural/ cool white as per requirement at site made of aluminium housing high translucent frosted plastic diffuser with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- PEARL NIO- S of Crompton/ INTERGA NXT SURFACE ROUND/ SQUARE of Havells/ Sleek Surface Downlight of Philips as approved. |
| 51 | Supplying, fixing & testing LED 15/18 Watt QUARTZ NEO (R) is a slim LEDdownlighter for recess and surface mounted round ceiling light fitting, warm/ natural/ cool white as per requirement at site made of aluminium with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make PEARL ULTIMA of Crompton/INTEGRA HE of Havells/GreenPerform Sleek of Phillips as approved. |
| 52 | Supplying, fixing & testing LED 10/12 Watt recess mounted round ceiling light fitting, warm/ natural/ cool white as per requirement at site made of aluminium with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make QUARTZ NEO (R) of Crompton/INTEGRA HE of Havells/GreenPerform Sleek of Phillips as approved. |
| 53 | Supplying, fixing & testing LED 5/6 Watt recess mounted round ceiling light fitting, warm/ natural/ cool white as per requirement at site made of aluminium with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make QUARTZ NEO (R) of Crompton/INTEGRA HE of Havells/GreenPerform Sleek of Phillips as approved. |
| 54 | S& F VTPN Distribution board empoxy powder coated fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with fully insulated 250 Amps copper Bus Bar for each phase and 02 neutral shrouded bar, 2 earth bar and cable tie for cable management with reversible door for IP- 43 IK- 09, 415 volt including provision of 160/ 200 Amp MCCB FP as incomer and SP MCBs or TP MCBs as per site requirement ( or any combination of SP/ TP MCBs) outgoing of following capacity. |
| 55 | 4 WAY VTPN DB ( FP MCCB + 12 MCBs).Make : 507745 of Legrand or equivalent in L & T/ Siemens. |
| 56 | 8 WAY VTPN DB TP & N DB( FP MCCB+24 MCBs) Make: 507747 of Legrand or equivalent in L&T/ Siemens. |
| 57 | S & F in repair MCB DB complying with IEC 61439- 1 & 3., sheet metal enclosures double door including 01 x 40 to 63 Amp SPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 100A.240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DBshall be supplied with all insulted N.Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity. |
| 58 | 4 way SPN DB. |
| 59 | 8 way SPN DB. |
| 60 | 12 way SPN DB. |
| 61 | 16 way SPN DB. |
| 62 | S&F in repair MCCB 4 pole 415 volts with rupturing capacity 36 KA with thermal-magnetic release and adjustable overload setting complete all as specified and directed of following capacity.Make :- Legrand/L&T/Siemens/Indo aAsian. |
| 63 | 125 Amps. |
| 64 | 160 Amps. |
| 65 | 100 Amps |
| 66 | S & F in repairs MCB SP complying to IS/IEC 60898, 240 volts \"B\" Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A. The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault.The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed of follwing capacity: |
| 67 | MCB SP 6 to 32 Amp.240 volts |
| 68 | MCB SPN 40 to 63 Amps 240 volts |
| 69 | S&F in repairs MCB TPN/FP 40 to 100 Amp as per requirement complying to IS/IEC 60898, 240 volts \"B\" Curve 10 KA with energy limiting class 3. The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed. |
| 70 | S&F in repair white modular cover plate with frame of following module complete including taking down old unsv modular cover plate with frame all as directed. |
| 71 | 3Module |
| 72 | 6Module |
| 73 | 12Module |
| 74 | S & F in repair modular metal flush of following module complete taking down old unsv modular metal flush box with frame all as directed |
| 75 | 3Module |
| 76 | 6Module |
| 77 | 12Module |
| 78 | Supply and fix in repair PVC Casing Caping of size 25 x16mm inclusive of all tees,bend elbow and fixing acessories including taking down old unsv pvc casing caping all as specified and directed. |
| 79 | Supply and fix in repair Exhaust fan 250 mm sweep, 1200 RPM, made up of Sturdy Engineering Plastic complete voltage 230 Volts 50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make: BAJAJ/ HAVELLS/ CROMPTON |
| 80 | Supply and fix in repair Exhaust fan 300 mm sweep, 1200 RPM, made up of Sturdy Engineering Plastic complete voltage 230 Volts 50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make:BAJAJ/ HAVELLS/ Crompton. |
| 81 | S & F in repair Esteem 400mm sweepWall mounted fan doublestring 1350 RPM high speed and 65 CMM Air Delivery strudy base and thermal overload protection wateg 65W, 230 Volts,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, etc including taking down old unsv wall mounted fan complete all as specified and directed.Make: BAJAJ/HAVELLS/Crompton |
| 82 | Supply and fix in repair LED inverter bulb 9 watt retrofit type works on AC Normal mode and DC supply in inverter mode with inbuilt battery back up of up to 4 hours, high efficiency high lumens output including taking down old unsv led bulb complete all as specified and directed.Make: Philips/Crompton/Havells |
| 83 | S&F in repair pressed steel sunken terminal boxes 1.6 mm thick, 60 mm including brass screws and cup washer including suitable size of hylam shett cut as per the the requirement at site of following size for mounting switch, socket fan regulator etc including taking down existing the existing unsericable sunken terminal boxes complete all as directed |
| 84 | 125 x 125 mm |
| 85 | 200 x 125 mm |
| 86 | 250 x 300 mm |
| 87 | S&F WALLWASHER led Light fitting 6H,7W 3000K 230volts as per requirement at site made of aluminium housing high translucent frosted plastic diffuser with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.Make- \"Brilant\" of Havells/Philips/Crompton as approved. |
| 88 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 89 | S & F in repair metal finished bed side lamp grey in colour 4 Watt connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to wall including taking down existing fitting complete all as specified and directed.Make: CAT NO 31437 OF Philips/CAT NO; LHEXCIPPN1K004 OF Havells /CROMPTON |
| 90 | Supply and fix in repair LED Up Down twin glow 20W + 20W light fitting of lumens 2000 lumens wall mounted, high pressure die cast alluminium, fully diffused, polycarbonated diffuser, system efficacy 100L/W complete all as specified and directed. |
| 91 | S&F in Muziris LED picturelight (Bronze) 12 W model provides a warm white light with Bronze aluminum finesh a color temperatur 3000k(warm white. lumen output 420 lm. life time up to25000 hours. and integrated led power 220-240 V IP 20 and dimension : 465x205x100 mm. adjustability flexible neck foradjusting beam.complete all as specified & directed by Engineer - in- Charge. |
| 92 | S & F REO modular AC MCB box protected socket PVC Plastic base three- Module including 25 Amps Plug top and MCB 25 Amps Fixed in repair complete all as specified and directed |
| 93 | S&F modular switch socket combination box 16 Amp, 6 pin, 3 module(2 hole complete with suitable connection with 2x2.5 sqmm and 1x1.5 sqmm single core cable length upto 01 mtr complete all as specified and directed by Engr-In-Charge. |
| 94 | Supply and fix electric water heater, shock - resistant & rust- proof engineering thermoplastic body efficien long - life copper heating element (3 Kw) capacity 3 litre, Neon indicators for power on & heating function & tank design is suitable to withstand 6.5 bar pressure suitable for high- rise buildings & complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed by Engr-in-Charge. |