| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Demolishing brick work in cement mortar manually/ by mechanical means including disposal of unserviceable material with in 50 m. lead as per direction of Engineer-in-charge. In lime mortar. |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq. metres and below. |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size |
| 6 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Fixing with adjustable lugs with split end tail to each jamb |
| 7 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes |
| 8 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) Second class teak wood , 35 mm thick shutters, |
| 9 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. size 300x16mm |
| 10 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. Size200x10mm |
| 11 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. Size 125mm |
| 12 | Providing and fixing 2nd class teak wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer-in-charge |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform |
| 15 | R.c.c. work in beam , suspended floor , roofs having slope up to 15* landing ,balconies , shelves chhajjas , lintals , bands , plan window sills stair case and spiral staircases above plinth level up to floor v level , excluding the cost of centerring , shuttering , finishing and rainforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone III) deried from natural sourses :3 graded stone aggregad 20mm nominal size derived from natural sourses |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 17 | 12 mm Cement Plaster of Mix: 1:4 ( 1 Cement: 4 Course sand) |
| 18 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 19 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two Coats. |
| 20 | Finishing external wall with Two or more coats of Premium Acrylic smooth exterior paint with silicone additives of required shade over and including priming coat of exterior primer to give an even shade after throughly brushing the surface including curing and cost all materials. |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 22 | Provoding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). DSR 11.47.2 2021 Size of Tile 600x600 mm |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 26 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 27 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ,15 mm nominal bore |
| 28 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 29 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 30 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm dia |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.25 mm dia |
| 33 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):25 mm nominal bore |
| 34 | Providing and fixing white vitreous china water closet scautting pan (indian type) along with \"\"S\"\" or \"\"P\"\" trap including dismantling of old WC seat and \"\"S\"\" or \"\"P\"\" trap at site complete with all operations including all necessary materials ,labour and disposal of dismantled material i/c malba ,all complete as per the direction of engineer-in charge. urisa pattern W.C panof size 580x440 mm |
| 35 | looking mirror with polish of 600x450 mm size with bevelled as per pwd sor ch 22 item 14 |
| 36 | Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank , IS:12701 marked with cover and suteble locking arrangement and making nacessary holes for inlet, outlet and over flow pipe but without fittings and base support for tank |
| 37 | P/f p.v.c. low lelel flushing cistern with manualy controled device (handle) lever conforming to IS: 7231,with all fittings and fixtures complete 10 ltr. Capicity , white . |
| 38 | C.P. brass towel ring jaqur essco ,sera hindware as per pwd sor ch 22 item 23 |
| 39 | C.P. brass soap dish jaqur essco ,sera hindware as per pwd sor ch 22 item 24 |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 41 | P/F. pvc band for rain water drainage etc. dia 100. mm of aproved make as per direction of engineer in charge as per pwd sor ch-no. 1 item no. 17.33 |
| 42 | c.p. brass shower havy quality jaquar essco, sera ,hind ware 100 mm dia as per pwd sor ch 21 item55 |
| 43 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Rate as per DSR (E&M)ch 1 (1.1) |
| 45 | Wiring for light /power plug with 4x4 sq. mm FRLC PVC insulated copper conductor single core cable in surface / recessed steel conduit alongwith 2 Nos 4 sq. mm FRLC PVC insulated copper conductor single core cable for loop earthing as required. |
| 46 | wiring for circuit/ submain wiring alongwith earth wire with the following size FRLC PVC insulated copper conductor single core cable in surface / recessed steel conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq, mm earth wire |
| 47 | wiring for circuit/ submain wiring alongwith earth wire with the following size FRLC PVC insulated copper conductor single core cable in surface / recessed steel conduit as required.2 x 2.5 sq. mm + 1 x 2.5 sq, mm earth wire |
| 48 | wiring for circuit/ submain wiring alongwith earth wire with the following size FRLC PVC insulated copper conductor single core cable in surface / recessed steel conduit as required.2 x 4 sq. mm + 1 x 4 sq, mm earth wire |
| 49 | wiring for circuit/ submain wiring alongwith earth wire with the following size FRLC PVC insulated copper conductor single core cable in surface / recessed steel conduit as required.2 x 6 sq. mm + 1 x 6 sq, mm earth wire |
| 50 | Providing and Fixing following capacity TP&N disconnector fuse swtich unit inside the existing pannel board with ISI mark HRC fuses including drilling hole incubicle panel, making connection etc. as required.32 A TP&N 32 A TP&N |
| 51 | Providing and Fixing following capacity TP&N disconnector fuse swtich unit inside the existing pannel board with ISI mark HRC fuses including drilling hole incubicle panel, making connection etc. as required.32 A TP&N 63 A TP&N |
| 52 | Providing and Fixing following capacity TP&N disconnector fuse swtich unit inside the existing pannel board with ISI mark HRC fuses including drilling hole incubicle panel, making connection etc. as required.32 A TP&N 100 A TP&N |
| 53 | Providing and Fixing following rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubicle pannel board including drilling hole in cubicle panel, making connection etc. as required. 100 A 16 KA, TPMCCB |
| 54 | Supplying and fixing following way, single pole and nutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, nutral bar, earthing bar, din bar, interconnection, powder painted including earthing etc. as required.( but without MCB/ RCC/,Isolator) 8 way double door |
| 55 | Earthing with copper earth plate 600 mm x 600 mm x 3mm thick including accessories, and provinding masonry encloser with cover plate having locking arrangement and watering pipev of 2.7 mtr long etc.with charcoal/ coke and salt as required. |
| 56 | S/F of LED tube light fitting suitable for 1x20 watt complete including LED tube light fitting etc. complete in all respect of Philips/ Bajaj/ NEXT. or Crompton make as per P.W.D. Electrical schedule item No. 453 cat AA(Seg) |
| 57 | Supply, Installation, Testing and Commissioning of 1200 mm sweep. BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulaton: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019). THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz. single phase AC Supply, earthing etc. complete as required. |
| 58 | Providing and fixing kitchen sink stanless steel ISI 304 (18/8) with c.i. brackets ,cp. Brass chain with rubber plug, 40 mm cp. Brass waste complete , including painting the fittings and brackets ,cutting and making good the walls wherever requried . (510X1040)mm bowl depth 250 mm |
| 59 | Supply and Laying of local river sand as Filter Material |
| 60 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge.16.91.2 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 61 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, Including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid |
| 62 | Supplying and fixing Main Steel Gate of 4.00x2.00 (2x2.00X2.00 M) & Side Steel Gate of 1.50x2.00 (1x1.50X2.00 M) on Square Pipe frame 40x40x5mm Filling With 70x2 mm Square Pipe with one coat of red oxide primer & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.(all work Done as par direction of Engineer-in- charge) including cost of all material, Labour T&P etc . |
| 63 | Taking out roots of trees of above 0.15m and 0.30m. Dia by manual as per idsor ch iv item c 2 |
| 64 | Cleaning thick jungle and uprooting behaya & disposel beyond 100 mts.as per idsor ch iv item 7b |
| 65 | Earth Work by power transport for a lead of upto 1 km including excavation ,loading, unloading, royalty, manual compactio and dressing i/c all lift rates shall be applicable for lead beyond 630 mtr and upto 1 km. As per IDSOR CH.- V Item no. 25 |
| 66 | Providing & fixing 5KW off grid Solar System I/C all Cost of material , labour T&P etc. All work Done As per U.P Neda Norms. |
| 67 | Pannel description:-Supply and fixing and steam cured prestressed concreate of grade M25 or richer mix (pretensioned with 4 nos. 4mm hts wire) slab of size 2100mmx300mmx50m with provision for hole (if required ) for fixing of angle at the top and fixing the same at proper position in between the two pillers .at the toe and the fixing the same at proper position in between the two pillers . Piller desscription :- S/F in position of steam cured prestressed concreate of grade or richer mix (pretensiond with 7 no 4 mm hts wire) piller of cross (6x6) and both edges grooves (2\"x2\") for holding precost slabs / pannel . hight of wall 8 feet , it wil be 6 feet above the ground and 2 feet bellow ground level ante rust concertina wire (ZAL:- Aluminium and powdder coted ) concertina wire fencing of material G.I. or ZAL wire dia 2.60mm , coil dia 400 mm with 2500 GSM zink coating with blade profile BTO-22 and CBT -6 i/c ssupporting angle arrangement per fixing of concertina wire. As per Letter 10459/ Sixth/TS/E-1-2 Dated 27/12/2021 (boundry wall) |
| 68 | pcc 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources under interlocking block |
| 69 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Please Enable Macros to View BoQ information |