Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge, with piano type switch, phenolic laminated sheet, suitable size M.S. Box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required |
| 2 | ..do..but 2 way light point with 2 nos. two way P.T. switch. |
| 3 | Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge with modular type switch, modular plate,suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | .....do.....but 2 way light point with 2 nos. two way modular switches. |
| 5 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch , phenolic laminated sheet, suitable size M.S. Box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required |
| 6 | Wiring for twin control light point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 mm². FRLS PVC insulated copper conductor single core cable etc. as required. |
| 7 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required. |
| 8 | Wiring for twin control light point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required. |
| 9 | Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable make and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in existing surface/ recessed steel/ PVC conduit including dismantling as required. |
| 10 | Rewiring for twin control light point with 1.5 mm² FRLS PVC insulated copper conductor single core cable and 1.5 mm² FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 11 | Supplying and fixing 1.5 mm thick metal box of 150 mm x75 mmx 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch , connection, painting etc. as required. (for light plug to be used in non residential buildings). |
| 12 | Supplying and fixing 1.5 mm thick metal box of 180 mm x 100 mmx 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 amps & 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as required.. |
| 13 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. |
| 14 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.. |
| 15 | Supplying and Wiring for circuit/ submain line with 2x1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge along with 1 no 1.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 16 | .....do..... but 2x2.5 mm² + 1x2.5 mm² earth wire |
| 17 | .....do..... but 2x4 mm² + 1x4 mm² earth wire |
| 18 | .....do.....but 2x6 mm² + 1x6 mm² earth wire |
| 19 | .....do..... but 2x10 mm² + 1x6 mm² earth wire |
| 20 | .....do..... but 2x16 mm² + 1x6 mm² earth wire |
| 21 | .....do..... but 4 X 4 mm² + 2 X 4 mm² earth wire |
| 22 | .....do..... but 4 X 6 mm² + 2 X 6 mm² earth wire |
| 23 | .....do..... but 4 X 10 mm² + 2 X 6 mm² earth wire |
| 24 | .....do..... but 4 X 16 mm² + 2 X 6 mm² earth wire |
| 25 | Supplying and Wiring for circuit/ submain line with 2 nos. 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit ISI along with 1 no. 1.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 26 | .....do..... but 2x2.5 mm² + 1x2.5 mm² earth wire |
| 27 | .....do..... but 2x4 mm² + 1x4 mm² earth wire |
| 28 | .....do.....but 2x6 mm² + 1x6 mm² earth wire |
| 29 | .....do.....but 2x10 mm² + 1x6 mm² earth wire |
| 30 | .....do.....but 2x16 mm² + 1x6 mm² earth wire |
| 31 | .....do.....but 4x4 mm² + 2x4 mm² earth wire |
| 32 | .....do.....but 4x6 mm² + 2x6 mm² earth wire |
| 33 | .....do.....but 4x10 mm² + 2x6mm² earth wire |
| 34 | .....do.....but 4x16 mm² + 2x6 mm² earth wire |
| 35 | Supplying and drawing 2 x 1.5 sq mm sizes of FRLS PVC insulated copper conductor, single core cable in the exisiting surface/ recessed steel/PVC conduit as required with connection complete. |
| 36 | .....do..... but 3 X 1.5 sq mm |
| 37 | .....do..... but 3 X 2.5 sq mm |
| 38 | .....do..... but 3 X 4 sq mm |
| 39 | .....do..... but 2 X 6 sq mm |
| 40 | .....do..... but 3 X 6 sq mm |
| 41 | .....do..... but 2 X 10 sq mm |
| 42 | .....do..... but 2 X 16 sq mm |
| 43 | .....do..... but 2 X 25 sq mm |
| 44 | .....do..... but 1 X 35 sq mm |
| 45 | .....do..... but 1 X 50 sq mm |
| 46 | Providing and fixing plain 16/0.20 mm(0.50 mm²) twin, circular flexible, FRLS PVC insulated, PVC sheathed copper cable direct on wall with PVC clips etc as required. |
| 47 | Supplying and fixing of 20 mm sizes of steel conduit ISI 16 gauge along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 48 | .....do..... but 25 mm size |
| 49 | .....do..... but 32 mm size |
| 50 | .....do..... but 40 mm size |
| 51 | S/F of G.I. Flexible pipe 32 MM size including suitable size of PVC saddle and others all accessories as required. |
| 52 | Supplying and fixing of 20 mm sizes of PVC conduit ISI along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 53 | .....do..... but 25 mm size |
| 54 | .....do..... but 32 mm size |
| 55 | S/F of steel wire rainforced flexible uPVC pipe 20 MM size including suitable size of PVC saddle and others all accessories as required. Makes : AKG/ BEC/ Prescision |
| 56 | .....do..... but 25 MM size |
| 57 | .....do..... but 30-32 MM size |
| 58 | S/F of PVC Batten/casing caping of 20X12 MM size including suitable size of PVC cover and others all accessories as required. |
| 59 | .....do..... but 25X12 MM size |
| 60 | .....do..... but 32X12 MM size |
| 61 | .....do..... but 50X16 MM size |
| 62 | .....do..... but 50X50 MM size |
| 63 | .....do..... but 75X50 MM size |
| 64 | .....do..... but 100X50 MM size |
| 65 | Supplying and fixing metal box of 75 mm x 75 mm x 60 mm deep sizes 1.5 mm thick sheet on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 66 | .....do..... but 100 mm x 100 mm x 60 mm deep |
| 67 | .....do..... but 180 mm x 100 mm x 60 mm deep |
| 68 | .....do..... but 200 mm x 150 mm x 60 mm deep |
| 69 | .....do..... but 200 mm x 250 mm x 60 mm deep |
| 70 | .....do..... but 200 mm x 300 mm x 60 mm deep |
| 71 | .....do..... but 250 mm x 300 mm x 60 mm deep |
| 72 | S/F of 5/6 Amp P.T. Switch on existing switch box including connection etc required. |
| 73 | .....do..... but 2-way 5/6 amp switch |
| 74 | .....do..... but 15/16 amp switch |
| 75 | .....do..... but 5 pin 5/6 amp socket outlet |
| 76 | .....do..... but 6 pin 15/16 amp socket outlet |
| 77 | .....do..... but Bell push |
| 78 | .....do..... but Batten/Angle holder |
| 79 | .....do..... but stepped type electronic fan regulator |
| 80 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 81 | Supplying and fixing 5/6 amps modular type switch on existing modular type plate & switch box including connections but excluding modular plate etc. as required. |
| 82 | .....do..... but 2-way 5/6 amp switch |
| 83 | .....do..... but 15/16 amp switch |
| 84 | .....do..... but 5 pin 5/6 amp socket outlet |
| 85 | .....do..... but 6 pin 15/16 amp socket outlet |
| 86 | .....do..... but Bell push |
| 87 | .....do..... but stepped type electronic fan regulator |
| 88 | .....do..... but modular blanking plate. |
| 89 | Supplying and fixing 1 or 2 module size/ modules, G.I. box along with modular base & cover plate for modular switches in recess etc as required. |
| 90 | .....do.....but 3 module |
| 91 | .....do.....but 4 module |
| 92 | .....do.....but 6 module |
| 93 | .....do.....but 8 module |
| 94 | .....do.....but 12 module |
| 95 | Supplying and fixing 1 or 2 module size/ modules, PVC box along with modular base & cover plate for modular switches in recess/surface etc as required. |
| 96 | .....do.....but 3 module |
| 97 | .....do.....but 4 module |
| 98 | .....do.....but 6 module |
| 99 | .....do.....but 8 module |
| 100 | .....do.....but 12 /16 module |
| 101 | Supplying and fixing 1 or 2 module Modular base & cover plate on existing modular metal boxes etc. as required. |
| 102 | .....do.....but 3 module |
| 103 | .....do.....but 4 module |
| 104 | .....do.....but 6 module |
| 105 | .....do.....but 8 module |
| 106 | .....do.....but 12/18 module |
| 107 | S/F of 2.8 to 3 mm thick phenolic laminated bakelite sheet including cutting as required with brass machine screw and cup washer complete. |
| 108 | S/F of 1.5 - 2.00 mm thick Stainless steel sheet including cutting as required with machine screw and cup washer complete. |
| 109 | Supplying and fixing call bell suitable for A.C. single phase, 230 volts, complete as required. |
| 110 | Providing and fixing 125 amp, 16 KA, rating and breaking capacity TP MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 111 | ...do- but 150 / 160 amp 35 KA |
| 112 | .....do..... but 250 amp 35 KA MCCB |
| 113 | .....do..... but 400 amp 35 KA MCCB |
| 114 | .....do..... but 630 amp 50 KA MCCB |
| 115 | Providing and fixing 125 amp, 36 KA, rating and breaking capacity 4P MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 116 | .....do..... but 250 amp 36 KA MCCB |
| 117 | .....do..... but 400 amp 50 KA MCCB |
| 118 | .....do..... but 630 amp 50 KA MCCB |
| 119 | Supplying and fixing of 8-way, double door prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 120 | .....do..... but 12-way, double door |
| 121 | .....do..... but 16 way, Double door |
| 122 | Supplying and fixing 4 way (4+12), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 123 | do... but 6 way (6 + 18), double door TPN DB |
| 124 | do... but 8 way (4 + 24), double door TPN DB |
| 125 | Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type, 415 volts, prewired, TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB\"s , detachable gland / knock out plate and superior make terminal connectors for all incommining and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link and ready for installation of 4 ways (4+12) double door (but with out MCB\"s and incommer MCCB) as required. |
| 126 | ..do.. but 8 way (4 + 24), double door VTPN DB |
| 127 | ..do..but12 way (4 + 36), double door VTPN DB |
| 128 | Removal / Fixing off size, SPN type sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with connection, repairing etc. including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 129 | Removal / Fixing off size, TPN type horizontal / Vertical, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with connection, repairing etc. including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 130 | Supplying and fixing Cable End Box (Loose Wire Box) suitable fortriple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 131 | Supplying and fixing 5 amps to 32 amps rating single pole, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 132 | Supplying and fixing of 16 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, Single Pole Modular circuit breaker suitable for inductive load in the existing Modular Box complete with connections, testing and commissioning etc as required. |
| 133 | .....do..... but 40 to 63 amp SP MCB |
| 134 | .....do..... but 5 to 32 amp DP MCB |
| 135 | .....do..... but 40 to 63 amp DP MCB |
| 136 | .....do..... but 5 to 32 amp TP MCB |
| 137 | .....do..... but 40 to 63 amp TP MCB |
| 138 | .....do..... but 5 to 32 amp 4P MCB |
| 139 | .....do..... but 40 to 63 amp 4P MCB |
| 140 | Supplying and fixing of 06-32 amps, Icn=6kA, rating, “C” curve, DC Single Pole miniature circuit breaker suitable for inductive and resistive load in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 141 | ..do.. but 40 to 63 amp Icn=6kA, rating, DC SP MCB |
| 142 | .....do..... but 06-32 amps, Icn=6kA, rating, DC DP MCB |
| 143 | .....do..... but 40 to 63 amp Icn=6kA, rating, DC DP MCB |
| 144 | Supplying and fixing 25 amps rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 145 | .....do.....but 40 amps DP RCCB |
| 146 | .....do.....but 63 amps DP RCCB |
| 147 | Supplying and fixing 40 amps rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 148 | .....do.....but 63 amps 4P RCCB |
| 149 | Supplying and fixing 2P / 4P MCB sheet steel enclosure on surface/ recess for 415 volts complete with suitable bus bar for neutral including connections, testing and commissioning etc. as required. |
| 150 | Supplying and fixing TP/4P MCCB sheet steel enclosure on surface/ recess for 415 volts MCCB upto 250Amps complete with suitable bus bar for neutral including connections, testing and commissioning etc. as required. |
| 151 | Supplying and fixing of 63A , 415V TPN Industrial type socket outlet (three phase+ Neutral + Earth), with 4 pole and earth, metal enclosed plug top along with 63 A \"C\" curve 4PMCB, in sheet steel enclosere on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 152 | SITC of Panel Mounted Earth Leakage Relay (ELR) 240-415VAC/DC, 1 C/O (Pre Alarm) +1 C/O (Fault) current setting range 30mAmp- 30Amp equivalent to L&T make & cat no. 17K726QF4N complete with making suitable size cut out including mounting acessories and all connections as required. |
| 153 | SITC of Din Rail Mounted Earth Leakage Relay 220-415VAC, Mannual/ Auto reset, current setting range 30mAmp- 30Amp equivalent to L&T make & cat no. 17G745GF2/ 17G745KF2, complete with mounting acessories and all connections as required. |
| 154 | Supply and fixing of SPN Automatic Changeover switches with Current Limiter (ACCL) 400V, 30A/9-30A capacity on board/DB\"s etc complete with connections in all respects. |
| 155 | Supply and fixing of TPN Automatic Changeover switches with Current Limiter (ACCL) 430V, Settable overvoltage and undervoltage protection, protection against single phasing, AC-1 EB/DG 32A/32A capacity etc complete with connections in all respects. Equivalent to : Make:L&T :Cat no.AUCL03032032. |
| 156 | Supply and fixing of TPN Automatic Changeover switches with Current Limiter (ACCL) 430V, Settable overvoltage and undervoltage protection, protection against single phasing, AC-1 EB/DG 63A/50A capacity etc complete with connections in all respects. Equivalent to : Make:L&T :Cat no.AUCL03063050. |
| 157 | SITC of Automatic Changeover switch TPN, 63 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 158 | SITC of Motorised Automatic Changeover/ATS switch 4 pole, 125 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 159 | SITC of Motorised Automatic Changeover/ATS switch 4 pole, 250 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 160 | SITC of Motorised Automatic Changeover/ATS switch 4 pole, 400 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 161 | SITC of Motorised Automatic Changeover/ATS switch 4 pole, 630 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 162 | SITC of 4 Pole Power Contactors, 400 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 163 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 164 | Supplying and fixing 30 amps, 240 volts, TPN industrial type, socket, with 4 pole and earth, metel enclosed plug top along with 30 amps \"C\" series, TP MCB, in sheet steel enclosure on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 165 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure/ HDPE FRP Chamber with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 166 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 Meter bellow ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 167 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure/ HDPE FRP Chamber with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 168 | Supplying and laying 25 mm X 5 mm copper strip on surface/recess as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm in cluding soldering as required) |
| 169 | Providing and fixing 25 mm x 5 mm copper strip at 0.50 meter below the ground as strip earth electrode, including connection/termination with brass nut, bolt, spring washer etc.as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) on surface or in recess for connection including soldering etc. as required. |
| 170 | Providing and fixing G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete including soldering, clamping, CC as required |
| 171 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 mm² size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 172 | .....do.....but above 35 mm² and upto 95 mm² |
| 173 | .....do.....but above 95 mm² and upto 185 mm² |
| 174 | ...do.....but above 185 mm² and upto 400 mm² |
| 175 | Laying/Removal of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size upto35 mm² direct in ground including excavation and refilling the trench etc as required. but excluding sand cushioning and protective covering. |
| 176 | ........do..... but 35 mm² to 95 mm² cable |
| 177 | ........do..... but 95 mm² to 185 mm² cable |
| 178 | ........do..... but 185 mm² to 400 mm² cable |
| 179 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 core 10 mm² (25mm) size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 180 | ..do...but for 4 core 16 mm²(28mm) PVC cable. |
| 181 | ..do...but for 4 core 25 mm²(28mm) PVC cable. |
| 182 | ..do..but for 3½ or 4 core 35 mm²(32mm) PVC cable. |
| 183 | ..do...but for 3 ½ or 4 core 50 mm²(35 mm) PVC cable |
| 184 | ..do...but for 3 ½ or 4 core 70 mm²(38 mm)PVC cable |
| 185 | ..do...but for 3 ½ or 4 core 95 mm²(45 mm) PVC cable |
| 186 | ..do...but for 3 ½ or 4 core 120 mm²(45 mm) PVC cable |
| 187 | ..do...but for 3 ½ or 4 core 150 mm²(50 mm) PVC cable |
| 188 | ..do...but for 3 ½ or 4 core 185 mm²(57 mm) PVC cable |
| 189 | ..do...but for 3 ½ or 4 core 240 mm²(62 mm) PVC cable |
| 190 | ..do...but for 3 ½ or 4 core 300 mm²(70 mm) PVC cable |
| 191 | ..do...but for 3 ½ or 4 core 400 mm²(70 mm) PVC cable |
| 192 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 4 core 16 mm² PVC cable size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 193 | .....do.....but for 4 core 25 mm² PVC cable. |
| 194 | .....do.....but for 4 or 3 ½ core 35 mm² PVC cable. |
| 195 | .....do.....but for 3 ½ or 4 core 50 mm² PVC cable |
| 196 | .....do.....but for 3 ½ or 4 core 70 mm² PVC cable |
| 197 | .....do.....but for 3 ½ or 4 core 95 mm² PVC cable |
| 198 | .....do.....but for 3 ½ or 4 core 120-185 mm² PVC cable |
| 199 | .....do.....but for 3 ½ or 4 core 240 mm² PVC cable |
| 200 | .....do.....but for 3 ½ or 4 core 300 mm² PVC cable |
| 201 | .....do.....but for 3 ½ or 4 core 400 mm² PVC cable |
| 202 | Making earth point with boring 18 Mt. deep with 80 mm dia G.I. pipe “B” class ISI. The top pipe 6 mt. length will be duly holed across the pipe at a distance of 15 cm apart in 4 rows. The each joint should be welded/ Brazing, 30 cm x 30 cm CI / HDPE FRP chamber masonary housing, with filling earthing compound powder inside GI pipe complete as per direction of site in charge complete. |
| 203 | Supply and fixing of Chemical earthing with GI heavy earthing pipe 75 to 90 mm dia, 3 mtrs length with GI Strip 40 mm X 6 mm from top to bottom inside the pipe and pipe prefilled with growth hygroscopic gel.The work shall be completed by boring dia -100 mm, with backfill Chemical compound (50 Kg). The each joint should be welded/ brazing, 30 cm x 30 cm CI / HDPE FRP chamber complete, The Earthing shall be completed in all respect and tested on site for guranteed result of earth resisitance less than 1 ohms. |
| 204 | Supply and fixing of Chemical earthing with Copper heavy earthing pipe 50 to 65 mm, length -3 mtrs pipe with Copper Strip 40mm X 6mm from top to bottom inside the pipe and pipe prefilled with growth hygroscopic gel.The work shall be completed by boring dia -100 mm, with backfill Chemical compound (50 Kg). The each joint should be welded/ brazing, 30 cm x 30 cm CI / HDPE FRP chamber complete, The Earthing shall be completed in all reepect and tested on site for guranteed result of earth resisitance less than 1 ohms. |
| 205 | SITC of M.S. Louver/ Flap/ Shutter for Exhaust Fan 12\" (300mm) size with all fixing material, nut bolt etc. and T&P. |
| 206 | SITC of M.S. Louver/ Flap/ Shutter for Exhaust Fan 15\" (380mm) size with all fixing material, nut bolt etc. and T&P. |
| 207 | SITC of M.S. Louver/ Flap/ Shutter for Exhaust Fan 18\" (450mm) size with all fixing material, nut bolt etc. and T&P. |
| 208 | SITC of Thermoplastic Cable Junction Box IP 65 Dimensions (LXBXH) 155 x 210 x 92 mm with metric knockouts for cable entry suitable for 10-16 sq.mm PVC sheathed armoured cable with 5 pole Terminal Set and one no. 5-32A SP MCB \"C\" Curved for cable connections fixed on support (DIN Rail) with provision of continuity of loop earthing between I/C & O/G cables as required, equivalent to Hensel Cat No.KF1616G (Make-Hensel / Siemens) |
| 209 | SITC of Thermoplastic polycarbonate IP65 in accordance with EN 60 529 (Dust proof, water proof & weatherproof) junction box size- (300X300X195) mm shock proof, rust proof, corrosion free with metric knockouts for cable entry suitable for min 25 sq.mm size PVC sheathed armoured cable with Terminal Sets for cable connections fixed on support (DIN Rail) with provision of neutral bus and continuity of loop earthing between I/C & O/G cables as required, equivalent to Hensel Cat no. HEN MI JB-2540-2023 Hensel. The box shall be fixed on pole with suitable D clamp(s) and nut bolts etc as required. |
| 210 | SITC of Thermoplastic polycarbonate IP65 in accordance with EN 60 529 (Dust proof, water proof & weaherproof) junction box size- (300X450X195) mm shock proof, rust proof, corrosion free with metric knockouts for cable entry suitable for min 25 sq.mm size PVC sheathed armoured cable with Terminal Sets for cable connections fixed on support (DIN Rail) with provision of neutral bus and continuity of loop earthing between I/C & O/G cables as required, equivalent to Hensel Cat no. HEN MI JB-2540-2023 Hensel). The box shall be fixed on pole with suitable D clamp(s) and nut bolts etc as required. |
| 211 | Disconnection, dismantalling & Shifting of old Electric panel / Feeder pillar. After dismantalling the panels to be sent to central / zonal store, as per direction of site incharge. |
| 212 | Supplying and fixing of Digital Ammeter equivalent to Make: Secure & Model DPM I310 in existing panel/DB complete with all connections, testing and commissioning etc as required. |
| 213 | Supplying and fixing of Digital Voltmeter equivalent to Make: Secure & Model DPM V310 in existing panel/DB complete with all connections, testing and commissioning etc as required. |
| 214 | Supplying and fixing of Digital Multifunction Meter equivalent to Make: Secure & Model Elite 102 in existing panel/DB complete with all connections, testing and commissioning etc as required. |
| 215 | SITC of 100/5- 600/5 CT burdan 15 VA, tap wound and ring type CL -1 complete with all connections including all mounting accessories in all respect. |
| 216 | SITC of LED Indicator 230V or more as required, AC/DC as required complete with all connections including all mounting accessories in all respect. |
| 217 | Removal / fixing of off size of perforated cable trays in convenient section, removel from joining with connectors, which suspended from the ceiling with M.S suspenders including bolt & nut suspenders etc as requried. complete in all respect. |
| 218 | Cleaning of Ceiling/Wall/ Pedestal/Cabin/ Exhaust/ Frseh Air Fan installed at several locations in different departments /residences /offices by using own ladder and T&P as required for proper completion of work. |
| 219 | Making hole for installation of exhaust fan of size upto 450 mm sweep by demolishing brick work manually/by mechanical means including disposal of malba within 50 meters lead and making good the wall by plastering etc. as required. |
| 220 | SITC of desert air- cooler strong air delivery (3400 CMH approx) with minimum three speed operation , fully collapsible louvres complete equivalent to orient snowbreeze slim 55, complete in all respect. |
| 221 | SITC of Pedestal fan 400 mm Sweep revolving type with speed regulator. |
| 222 | SITC of Wall mounting fan 400 mm Sweep revolving type with speed regulator. |
| 223 | SITC of 240 V, 150 MM sweep PVC body exhaust fan in existing opening and making good finish with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 224 | SITC of 240 V, 200 MM sweep PVC body exhaust fan in existing opening and making good finish with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 225 | SITC of 240 V, 250 MM sweep PVC body exhaust fan in existing opening and making good finish with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 226 | SITC of 240 V, 225-230 MM sweep, light duty metallic body exhaust fan in existing opening and making good finish the damage with plaster and all masonary work , connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 227 | SITC of 240 V, 300 MM sweep, light duty metallic body exhaust fan in existing opening and making good finish the damage with plaster and all masonary work , connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 228 | SITC of 240 V, 375-380 MM sweep, 900 RPM heavy duty exhaust fan in existing opening including making good finish the damage with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 229 | SITC of 240 V, 300 MM sweep, 900 RPM heavy duty exhaust fan in existing opening including making good finish the damage with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 230 | SITC of 240 V, 450 MM sweep, 900 RPM heavy duty exhaust fan in existing opening including making good finish the damage with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 231 | SITC of 240 V, 350/450 MM sweep, heavy duty metallic body exhaust fan motor in existing exhaust fan body, 900/1200 RPM single phase electrical exhaust fan, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. copper conductor, single core etc. |
| 232 | SITC of 240 V, 200/250/300 MM sweep, light duty PVC/MS body exhaust fan motor in existing exhaust fan body, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. copper conductor, single core etc. |
| 233 | SITC of 240 V, Desert Air cooler motor in existing water cooler body, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. copper conductor, single core etc. |
| 234 | SITC of 240 V, Desert Air cooler water pump motor in existing water cooler body, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. copper conductor, single core etc. |
| 235 | SITC of 240 V, 450 MM sweep, heavy duty air cerculator wall fan including making good finish the damage with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 236 | Supply, Installation, Testing and Commissioning of 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum), ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum≥ 5.1, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply earthing etc. complete as req |
| 237 | Do but 1200 mm service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 238 | Do but 1400 mm service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 239 | Providing and fixing G.I. pipes 15/16mm dia (Medium B class) complete with G.I. fittings including trenching and refilling etc. |
| 240 | Supplying and embedding 32 mm dia G.I. pipe (medium B class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required |
| 241 | Supplying and embedding 40 mm dia G.I. pipe (medium B class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required |
| 242 | Providing, laying and fixing B class medium ISI 50 mm dia G.I. pipe in ground complete with G.I. fittings including boring/ trenching (75 cm deep) and re-filling etc as required |
| 243 | .....do.....but G.I. Pipe 80 mm dia. |
| 244 | .....do.....but G.I. Pipe 100 mm dia. |
| 245 | Supplying and installing of 100 mm width X 50 mm depth X 1.6 mm thickness perforated painted with powder coating M.S. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 246 | .....do.....150 mm width X 50 mm depth X 1.6 mm thickness |
| 247 | .....do.....200 mm width X 50 mm depth X 1.6 mm thickness |
| 248 | .....do.....450 mm width X 50 mm depth X 2.0 mm thickness |
| 249 | Supplying and installing of 50 mm width X 25 mm depth X 0.6 mm thickness perforated painted with powder coating Metal/ GI raceway with bracket for fixing raceway 50x25 mm, coupler for joining raceway with proper nut bolts as per site requirement with proper connection etc as required. |
| 250 | SITC of LED light fitting 600mm length minimum 1000Lumen with mounting rail box / aluminium extruded Batten suitable for surface, wall and conduit mounting with acessories and prewired with both side end cap equivalent to Wipro Cat no. LL20-111-XXX-65NE3. Minimum five years warranty should be provided. |
| 251 | Supplying, installation, Testing & Commissioning of LED Batten light 18-22 watt (System lumen efficacy ≥120 <135 lm/Watt)surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 252 | SITC of LED light fitting BED Side Lamp with acessories and prewired equivalent to WIPRO Cat no. LJ14-020-XXX-40-OP Bedside Light 3-4W Cir. White. |
| 253 | SITC of Decorative lamp wall mounting, brushed nickle finish with opal glass diffuser suitable with 1x9W LED lamp & B22 base equivalant to Havells code no.LHFOAJE1TZ11060. complete in all respect. |
| 254 | SITC of Decorative lamp wall mounting, brushed nickle finish with opal glass diffuser suitable with 2x9W LED lamp & B22 base equivalant to Havells code no.LHFOAJE2TZ11060.complete in all respect. |
| 255 | SITC of suspended mounting LED Light fitting minimum lumen 3600 including driver equivalent to Havells cat no. DESTG250LP/S36WLED857SWH1130 with End Cap & Suspension kit as required complete all connections. |
| 256 | Supplying, Installation, Testing & Commissioning of LED Down lighter 5-7 watt(COB Type) (System lumen efficacy ≥120 lm/Watt ) Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 257 | Do but 12-15 watt as required complete in all respect. |
| 258 | Do but 22 watt as required complete in all respect. |
| 259 | SITC of LED surface spot light fitting, Energy saving, environmental friendly, long life, made up of aluminuim pressure die cast housing with toughened glass / polycarbonate cover, minimum 500 lumen output, equivalent to Havells Cat No. UNECOSURFDLS8WLED830S24WHT along with mounting brackets assembly. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 260 | SITC of LED wall surface Up-down light fitting, Energy saving, environmental friendly, IP 66, long life, made up of aluminuim pressure die cast housing with toughened glass / polycarbonate cover, minimum 25 watt output, IP66 protection, equivalent to Havells Cat No. CLIOWLS25WLED830PSYMTOTG along with mounting brackets assembly. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 261 | SITC of 2\"x2\" fully diffused recess/surface mounting LED luminaire with PIR Sensor, minimum 3600 lumen as light source, suitable for Armstrong/Grid Ceiling complete as required includung all connections equivalent to Havells no. VENUSNEOHE2X2R36WLED857PIRSENSOR. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 262 | Supplying, installation, Testing & Commissioning of LED Panel light ,18 watt, 2x2 ft., (System lumen efficacy >135 lm/Watt)light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 263 | Do but 36 watt LED Panel 2x2 feet as required complete in all respect. |
| 264 | Supplying, Installation, Testing & Commissioning of Street light LED fixture 36 Watt, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 ,P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 265 | Do but 50 watt LED street light as required complete in all respect. |
| 266 | Do but 72 watt LED street light as required complete in all respect. |
| 267 | Do but 100 watt LED street light as required complete in all respect. |
| 268 | SITC of LED Bollard light 5700k, IP65, 8-10 Watt equivalent to LED crompton Cat No. LBLSR-10-WW. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 269 | Supply and fixing of LED post top IP 65 latern spun aluminium landscape luminaire, symmetrical light distribution, clear/ opal acrylic diffuser, stainless steel hardware, 15 watt includung connections equivalent to Havells Cat No.RUBYMINPT15W LED757PSYMTOPC. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 270 | SITC of LED Bulkhead complete with connections as required equivalent to WIPRO Cat No. LW07-141-XXX-57-G1. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative.. |
| 271 | SITC of recess mounting LED strip including driver minimum 5 metre length equivalent to WIPRO cat no. LSD6-005-120-30-50 with Driver. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 272 | Supplying, Installation, Testing & Commissioning of Flood Light, 50 watt powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt)with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 273 | Do but 100 watt LED Flood light as required complete in all respect. |
| 274 | Do but 150 watt LED Flood light as required complete in all respect. |
| 275 | Do but 200 watt LED Flood light as required complete in all respect. |
| 276 | SITC of Sensor LED tube fitting equivalent to WIPRO Cat No. LL28-221-5N-65-XX* with built in motion sensor and necessary arrangement to reduce to 30% in case of no occupancy or motion but instantly go to full light i.e. 18-20 watt as soon as some motion observed, complete with connection as required. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 277 | SITC of 3.00 Metre HDG Octagonal Pole with Top Dia 70 mm, Bottom Dia 130 mm & Sheet Thickness 3 mm ,base plate 200 x 200 x 12 mm alongwith 0.5 Metre single arm bracket ,suitable for 70mm Top complete with suitable size of the foundation bolt etc. as required. |
| 278 | SITC of 6.00 Metre HDG Octagonal Pole with Top Dia 70 mm, Bottom Dia 130 mm & Sheet Thickness 3 mm, base plate 200 x 200 x 12 mm alongwith 0.5 Metre single arm bracket ,suitable for 70mm Top complete with suitable size of the foundation bolt etc. as required. |
| 279 | Supply and Fixing of M.S. tubular pole SP-5, 7.5 Meter length with suitable canopy and cross arm single/ double as required. The pole shall be grouted in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling as required. |
| 280 | Supply and Fixing of M.S. tubular pole SP-32, 9.0 Meter length with suitable canopy and cross arm single/ double as required. The pole shall be grouted in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling as required. |
| 281 | Installation / Dismantling of Geyser rating 25 -50Ltrs including cartage upto store /central store as per instruction of site-in-charge. |
| 282 | SITC of Water Heater(Geyser) rating of 25 ltrs 5 star complete with all connections. |
| 283 | SITC of Water Heater(Geyser) rating of 35 ltrs 5 star complete with all connections. |
| 284 | SITC of Water Heater(Geyser) rating of 50 ltrs 5 star complete with all connection |
| 285 | SITC of Instant Water Heater(Geyser) rating of 3 ltrs complete with all connection |
| 286 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar,bent to shape with hooked ends in R.C.C. slabs or beams during laying,including painting the exposed portion of loop, all as per standard design complete. |
| 287 | Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for properbonding, top lid shall be screwed into the cast iron / M.S. sheet box by means of 3.3 mm dia roundheaded screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape asper standard drawing. |
| 288 | Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 289 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 mm² FRLS PVC insulated, copper conductor, single core cable etc as required after removel the old if required. |
| 290 | Installation of exhaust fan up to 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc after removal the old, as required. |
| 291 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc directly on ceiling/ wall, including connection with 1.5 mm² FRLS PVC insulated, copper conductor, single core cable and earthing etc after removal the old, as required. |
| 292 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 293 | Providing and making steel pole collar with cement concrete (1 cement: 3 coarse sand: 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) |
| 294 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required. |
| 295 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 Meters. |
| 296 | Earth work in excavation in soft soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. |
| 297 | Providing Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 298 | 12 mm Cement Plaster of Mix 1:6 ( 1 Cement : 6 Fine Sand) |
| 299 | Demolishing brick work in mortar manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 Meters lead as per direction of Engineer-in-charge. |
| 300 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 Meters lead of area beyond 3 sq.meters |
| 301 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 Meters lead as per direction of Engineer - in- charge |
| 302 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade Two or more coats on new work |
| 303 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete |
| 304 | Re-lettering with black Japan paint of approved brand and manufacture. |
| 305 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 306 | Disposal of building rubbish / malba / similar unserviceable, dismantledor waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or asapproved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 307 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 308 | Spray Painting of double coat of Electric Panel/Feeder after removal of old layer of paint, rusting etc. and providing the red oxide paint over the surface uniformly if required before spray painting including etc.The work shall be completed in all respect including repair including repair by welding/Denting and black paint on base chanel and MS frame as required (Only painted surface shall be measured for payment). |
| 309 | Painting of electric pole and number making if required (8.5mtr. to 14 mtr. long pole) with 1 coat of aluminium paint over redoxide primer after proper cleaning of rusted surface as required complete in all respects. |
| 310 | Painting of electric pole and number making if required (8.5mtr. to 14 mtr. long pole) with 1 coat of aluminium paint after proper cleaning of rusted surface as required complete in all respects. |
| 311 | Painting of electric pole and number making if required (5 mtr. to 8 mtr. long pole) with 1 coat of aluminium paint over redoxide primer after proper cleaning of rusted surface as required complete in all respects. |
| 312 | Painting of electric pole and number making if required (5 mtr. to 8 mtr. long pole) with 1 coat of aluminium paint after proper cleaning of rusted surface as required complete in all respects. |
| 313 | Painting of electric pole and number making if required (2.4 mtr. to 4.5 mtr. long pole) with 1 coat of aluminium paint over redoxide primer after proper cleaning of rusted surface as required complete in all respects. |
| 314 | Painting of electric pole and number making if required (2.4 mtr. to 4.5 mtr. long pole) with 1 coat of aluminium paint after proper cleaning of rusted surface as required complete in all respects. |
| 315 | SITC of factory fabricated 1.6 mm CRCA sheet, metal clad, dust and vermin proof wall mounted single door MS Box as required with size 400 x 300 x 150 mm duly powder coated spray painted fitted with 220 volt, pluggable interface AC Relay with realy base, Push button (illuminated actuators preassembled with LED Holder with NO + NC elements, Red indicatior and Multitone High durability AC/DC Hooter etc as required for One lift Hooter controler. This box shall be detachable side with hinge and locking arrangement. |
| 316 | SITC of factory fabricated 1.6 mm CRCA sheet, metal clad, dust and vermin proof wall mounted single door MS Box as required with size 400 x 300 x 150 mm duly powder coated spray painted fitted with 220 volt, pluggable interface AC Relay with realy base, Push button (illuminated actuators preassembled with LED Holder with NO + NC elements, Red indicatior and Multitone High durability AC/DC Hooter etc as required for Two lifts Hooter controler. This box shall be detachable side with hinge and locking arrangement. |
| 317 | SITC of factory fabricated 1.6 mm CRCA sheet, metal clad, dust and vermin proof wall mounted single door MS Box as required with size 400 x 300 x 150 mm duly powder coated spray painted fitted with 220 volt, pluggable interface AC Relay with realy base, Push button (illuminated actuators preassembled with LED Holder with NO + NC elements, Red indicatior and Multitone High durability AC/DC Hooter etc as required for Three lifts Hooter controler. This box shall be detachable side with hinge and locking arrangement. |
| 318 | SITC of factory fabricated 1.6 mm CRCA sheet, metal clad, dust and vermin proof wall mounted single door MS Box as required with size 400 x 300 x 150 mm duly powder coated spray painted fitted with 220 volt, pluggable interface AC Relay with realy base, Push button (illuminated actuators preassembled with LED Holder with NO + NC elements, Red indicatior and Multitone High durability AC/DC Hooter etc as required for Four lifts Hooter controler. This box shall be detachable side with hinge and locking arrangement. |
| 319 | Supply and Laying of 2CX1.5 Sqmm Copper Armoured , XLPE insulated, armoured, PVC sheathed cable, 1100V grade, at a depth of 750mm below the ground level over a cushion of 75 mm thick sand, alround and protected with burnt bricks on side and top. On surface, the cable shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-In-Charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps. etc. The cable shall be laid by boring the road asa required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 320 | 3CX1.5 Sqmm Copper Armoured |
| 321 | 4CX1.5 Sqmm Copper Armoured |
| 322 | 6CX1.5 Sqmm Copper Armoured |
| 323 | 10CX1.5 Sqmm Copper Armoured |
| 324 | 3CX2.5 Sqmm Copper Armoured |
| 325 | 4CX4.0 Sqmm Copper Armoured |
| 326 | 4CX6.0 Sqmm Copper Armoured |
| 327 | 4CX10.0 Sqmm Copper Armoured |
| 328 | 4CX16.0 Sqmm Copper Armoured |
| 329 | 3CX10.0 Sqmm Aluminimum Armoured |
| 330 | 3.5CX25.0 Sqmm Aluminimum Armoured |
| 331 | 3.5CX50.0 Sqmm Aluminimum Armoured |
| 332 | 3.5CX70.0 Sqmm Aluminimum Armoured |
| 333 | 3.5CX120.0 Sqmm Aluminimum Armoured |
| 334 | 3.5CX185.0 Sqmm Aluminimum Armoured |
| 335 | 4CX10.0 Sqmm Aluminimum Armoured |
| 336 | 4CX16.0 Sqmm Aluminimum Armoured |
| 337 | 4CX25.0 Sqmm Aluminimum Armoured |
| 338 | 4CX35.0 Sqmm Aluminimum Armoured |
| 339 | 4CX50.0 Sqmm Aluminimum Armoured |
| 340 | 4CX70.0 Sqmm Aluminimum Armoured |
| 341 | 4CX95.0 Sqmm Aluminimum Armoured |
| 342 | 4CX120.0 Sqmm Aluminimum Armoured |
| 343 | 4CX150.0 Sqmm Aluminimum Armoured |
| 344 | 4CX185.0 Sqmm Aluminimum Armoured |
| 345 | 4CX240.0 Sqmm Aluminimum Armoured |
| 346 | 4CX300.0 Sqmm Aluminimum Armoured |
| 347 | 4CX400.0 Sqmm Aluminimum Armoured |
| 348 | 1CX630.0 Sqmm Aluminimum Armoured |
| 349 | 1CX800.0 Sqmm Aluminimum Armoured |
| 350 | 1CX1000.0 Sqmm Aluminimum Armoured |
| 351 | Supply and Laying of 2CX1.5 Sqmm Copper Un-armoured, XLPE insulated, Un-armoured/ armoured as required, PVC sheathed cable, 1100V grade, on existing Hume pipe/ masonary duct (Trench)/ cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc. |
| 352 | 3CX1.5 Sqmm Copper Un-Armoured |
| 353 | 4CX1.5 Sqmm Copper Un-Armoured |
| 354 | 2CX6.0 Sqmm Copper Un-Armoured |
| 355 | 4CX10.0 Sqmm Copper Un- Armoured |
| 356 | 4CX16.0 Sqmm Copper Un- Armoured |
| 357 | 4CX25.0 Sqmm Copper Un- Armoured |
| 358 | 4CX35.0 Sqmm Copper Un- Armoured |
| 359 | 2CX1.5 Sqmm Copper Armoured |
| 360 | 3CX1.5 Sqmm Copper Armoured |
| 361 | 4CX1.5 Sqmm Copper Armoured |
| 362 | 6CX1.5 Sqmm Copper Armoured |
| 363 | 10CX1.5 Sqmm Copper Armoured |
| 364 | 3CX2.5 Sqmm Copper Armoured |
| 365 | 4CX4.0 Sqmm Copper Armoured |
| 366 | 4CX6.0 Sqmm Copper Armoured |
| 367 | 4CX10.0 Sqmm Copper Armoured |
| 368 | 4CX16.0 Sqmm Copper Armoured |
| 369 | 3CX10.0 Sqmm Aluminimum Armoured |
| 370 | 3.5CX25.0 Sqmm Aluminimum Armoured |
| 371 | 3.5CX50.0 Sqmm Aluminimum Armoured |
| 372 | 3.5CX70.0 Sqmm Aluminimum Armoured |
| 373 | 3.5CX120.0 Sqmm Aluminimum Armoured |
| 374 | 3.5CX185.0 Sqmm Aluminimum Armoured |
| 375 | 4CX10.0 Sqmm Aluminimum Armoured |
| 376 | 4CX16.0 Sqmm Aluminimum Armoured |
| 377 | 4CX25.0 Sqmm Aluminimum Armoured |
| 378 | 4CX35.0 Sqmm Aluminimum Armoured |
| 379 | 4CX50.0 Sqmm Aluminimum Armoured |
| 380 | 4CX70.0 Sqmm Aluminimum Armoured |
| 381 | 4CX95.0 Sqmm Aluminimum Armoured |
| 382 | 4CX120.0 Sqmm Aluminimum Armoured |
| 383 | 4CX150.0 Sqmm Aluminimum Armoured |
| 384 | 4CX185.0 Sqmm Aluminimum Armoured |
| 385 | 4CX240.0 Sqmm Aluminimum Armoured |
| 386 | 4CX300.0 Sqmm Aluminimum Armoured |
| 387 | 4CX400.0 Sqmm Aluminimum Armoured |
| 388 | 1CX630.0 Sqmm Aluminimum Armoured |
| 389 | 1CX800.0 Sqmm Aluminimum Armoured |
| 390 | 1CX1000.0 Sqmm Aluminimum Armoured |
| 391 | Supply and Laying of 3CX185 Sqmm Aluminium armoured 11kV(UE) , XLPE insulated, armoured, PVC sheathed cable, 11kV(UE) grade, at a depth of 1000mm below the ground level over a cushion of 75 mm thick sand, alround and protected with burnt bricks on side and top. On surface, the cable shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-In-Charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps. etc. The cable shall be laid by boring the road asa required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 392 | 3CX300 Sqmm Aluminium armoured 11kV(UE) |
| 393 | Supply and laying of 3CX185 Sqmm Aluminium armoured 11kV(UE), XLPE insulated, armoured, PVC sheathed cable, 11kV (UE) grade, on existing Hume pipe/ masonary duct (Trench)/ cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc. |
| 394 | 3CX300 Sqmm Aluminium armoured 11kV(UE) |
| 395 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 150-200 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge. |
| 396 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 200-250 mm depth duly powder coated spray painted with suitable Busbar up to 250 Amp capacity as required and separate chamber for instruments (e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge. |
| 397 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 500A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 400 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 500Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 398 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 500A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 600 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 500Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 399 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 800A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 400 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 800 Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 400 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 800A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 600 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 800Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 401 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 1600A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 1000 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 1600 Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 402 | Supply and fixing of compound of chemical earthing for reduces grounding resistance, improves electrical conductivity and prevents corrosion & degradation . Each packet 25 kg. Complete in all respect. |
| 403 | Supplying and laying of 160 mm dia (OD-160 mm & ID-135 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 404 | Supplying and laying of 200 mm dia (OD-200 mm & ID-175 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail