| 1 | EARTH WORKS: |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All Kinds of Soil |
| 4 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. |
| 6 | CEMENT CONCRETE WORKS: |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 8 | 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 9 | 1:5:10 (1 Cement:5 coarse sand:10 graded stone aggregate: 40 mm nominal size). |
| 10 | Providing & laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarsesand: 4 graded stone aggregate 20 mm nominal size) |
| 11 | MISCELLANEOUS: |
| 12 | Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouded with fine sand including finishing the top smooth. |
| 13 | R.C.C.WORKS: |
| 14 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level |
| 15 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 17 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 18 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 19 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 20 | Thermo-Mechanically Treated bars |
| 21 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Above Plinth Level. |
| 22 | Thermo-Mechanically Treated bars |
| 23 | FORM WORKS: |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 25 | Foundations, footings, bases of columns, etc. for mass concrete |
| 26 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 27 | Suspended floors, roofs, andings, balconies and access platform with water proof ply 12 mm thick. |
| 28 | Columns, pillars, piers, abutments, posts and struts. |
| 29 | BRICK WORKS: |
| 30 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 31 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Half brick masonry 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 33 | Cement mortar 1: 3 ( 1 cement: 3 coarse sand ) |
| 34 | Extra for half brick masonry in superstructure, above Floor V level for every four floors or part thereof by mechanical means by lifting materials using mobile crane |
| 35 | Brick edging 7cm wide 11.4 cm deep to plinth protection with 1st class common burnt clay F.P.S. (non modular) bricks i/c grouting with cement mortar 1:4(1 cement:4 fine sand). |
| 36 | WOOD WORKS |
| 37 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought frameed & fixed in position with hold fast lugs or dash fastener shall be paid for separately: |
| 38 | Local best quality teakwood |
| 39 | Providnig and fixing panelled or panalled and glazed shutters for foors, windows and celestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all completely asd per direction of Engineer-in-charge. |
| 40 | Local best quality teakwood |
| 41 | 35mm thick shutters |
| 42 | Providing & fixing M.S. Grills of required pattern in frames of windows etc. With M.S. Flats, square or round bars etc. Including priming coat with approved steel primers all complete. |
| 43 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 44 | Providing & fixing 25 mm thickshutters for cup-board etc. i/c ISI marked black enamelled M.S. butthinges with necessary screws. |
| 45 | Panelled or panelled and Glazed shutters |
| 46 | Ist Class Teak |
| 47 | Providing & fixing bright finished bars 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Best make of approved quality) |
| 48 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : |
| 49 | 300x16x5mm |
| 50 | Providing & fixing bright finished brass Tower bolts (barrel type) with necessary screws etc. complete. |
| 51 | 250x10 mm |
| 52 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: |
| 53 | 125 mm |
| 54 | FLOORING: |
| 55 | Cement plaster skirting (upto 30cm height) with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement. |
| 56 | 18 mm thick |
| 57 | Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 58 | Double charge vitrified tile polished finish of size - Size of Tile 600 x 600 mm |
| 59 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS : 15622 (thickness to be specified by the manufacture of approved make in alt colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (I cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 60 | Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with |
| 61 | Makrana White second quality |
| 62 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shadecomplete |
| 63 | Marble tiles(polished) Raj Nagar |
| 64 | 8 mm thick |
| 65 | ALUMINIUM WINDOWS |
| 66 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions Of Engineer-incharge. (Glazing and panelling to be paid for separately): |
| 67 | For fixed portion. |
| 68 | Anodised aluminium (anodised transparent or dyed to required kg940.50 shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 69 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 70 | Anodised aluminium (anodised transparent or dyed to required kg Rss 1.03280 shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 71 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 72 | With float glass panes of 5.50 mm thickness |
| 73 | FINISHING: |
| 74 | 6 mm cement plaster of mix |
| 75 | 1:3(1 Cement:3 fine sand) |
| 76 | 12 mm cement plaster of mix 1:4 (1 cement:4 coarse sand). |
| 77 | (1 cement:4 coarse sand) |
| 78 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). |
| 79 | 1:4 (1 cement:4 coarse sand). |
| 80 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 81 | New work(two or more coats)over and including priming coat with cement primer |
| 82 | Finishing walls with textured exterior paint of required shade: |
| 83 | New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 84 | Applying priming coat:- |
| 85 | With ready mix pink or grey primer of approved brand and manufacture on wood work(hard and soft wood) |
| 86 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth |
| 87 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 88 | Two or more coats on new work |
| 89 | STEEL WORKS |
| 90 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffinge polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 91 | Providing Water Supply and Sanitary Installation. |
| 92 | EARTH WORKS: |
| 93 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 94 | All Kinds of Soil |
| 95 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 96 | CEMENT CONCRETE WORKS: |
| 97 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 98 | 1:3:6 ( 1 Cement.: 3 coarse sand 6 graded stone aggregate 40 mm nominal size) |
| 99 | 1:4:8 ( 1 Cement: 4 coarse sand 8 graded stone aggregate 40 mm nominal size) |
| 100 | FORM WORKS: |
| 101 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 102 | Foundations, footings, bases of columns, etc. for mass concrete |
| 103 | Suspended floors, roofs, landings, balconies and access |
| 104 | RCC WORKS: |
| 105 | Reinforced cement concrete work in beams, suspended floors, roofs having stope upto 15landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 106 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 107 | Thermo-Mechanically Treated bars |
| 108 | PRE-CAST: |
| 109 | Providing, hoisting and fixing upto floor five lovol procast reinforced comont concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the tike including tho cost 01 required contoring, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3graded stone aggregate 20mm nominal size). |
| 110 | BRICK WORKS: |
| 111 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: cum |
| 112 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 113 | Half brick masonry 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 114 | Cement mortar 1: 3 ( 1 cement: 3 coarse sand ) |
| 115 | Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay FP.S. (non modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) |
| 116 | FLOORING: |
| 117 | Cement concrete flooring 1:2:4 (I cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost Of nosing of steps etc. complete. |
| 118 | 40mm thick with 20mm nominal size stone aggregate. |
| 119 | Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (I cement : 3coarse sand) finished with a floating coat of neat cement |
| 120 | 18 mm thick |
| 121 | SANITARY INSTALLATION |
| 122 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap. 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handlo lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 123 | White Vitreous china Orissa pattern W.C. pan of size 580 x 440mm with integral type foot rests |
| 124 | Providing and fixing white vitreous china flat back or wall corner type lipped Iront urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with utomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete. including painting of fittings and brackets, cutting and making good the walls and floors wherever required |
| 125 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 126 | Providing and fixing white vitreous china pedestal for wash basin eaccompletely recessed at the back for the reception of pipes and fittings |
| 127 | Providing and fixing P.V.C. tor sink or wash basin including P.V.C. waste fittings complete. |
| 128 | Flexible pipe |
| 129 | 32 mm dia |
| 130 | Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: |
| 131 | Size: 600x450x200mm |
| 132 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete. |
| 133 | Providing and fixing PTMT liquid soap container 109 mm wide, 125each 195.80 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 134 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 135 | Providing and fixing PTMT urinal cock of approved quality and colour. |
| 136 | 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. |
| 137 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge |
| 138 | 75 mm dia |
| 139 | 110 mm dia |
| 140 | WATER SUPPLY: |
| 141 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work. including cutting chases and making good the wall etc. |
| 142 | 15 mm diameter |
| 143 | 20 mm diameter |
| 144 | 25 mm diameter |
| 145 | Providing and fixing G.l. pipes complete with G.l. fittings including trenching and refilling etc. External work |
| 146 | 32 mm diameter |
| 147 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 148 | 15 mm diameter |
| 149 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confcrming to 1S.8931. |
| 150 | 15 mm diameter |
| 151 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 152 | 25 mm diameter |
| 153 | Providing and fixing gun metal non-return valve of approved quality (screwed end) |
| 154 | 32 mm diameter |
| 155 | horizontal |
| 156 | ProvidingandfixingC.P.brass shower rose with15mm or 20mm |
| 157 | 100 mm diameter |
| 158 | Providing and placing on terrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 159 | Land Development. |
| 160 | Banking excavated earth in layers not exceeding 20 cm. in depth, breaking clods,watering. rolling each layer with Y2 tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum B tonnes and dressing up, inembankments for roads, flood banks, marginal banks, and guidebanks etc., lead upto 50 m and lift upto 1.5 m. |
| 161 | All Kinds of Soil |
| 162 | Providing and Installation of Internal Elrctification |
| 163 | SUB HEAD-1: WIRING IN STEEL CONDUIT |
| 164 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 165 | Group A |
| 166 | Group B |
| 167 | Group C |
| 168 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed steel conduit 2 way modular type switch modular plate suitable size G.I box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as reqd |
| 169 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 170 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 171 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 172 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 173 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 174 | Supplying and drawing following pair) 0.5 sq.mm FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as reqd |
| 175 | 1 pair |
| 176 | 2 pair |
| 177 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 178 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 179 | 5/6 A switch |
| 180 | 2 way 5/6 amps switch |
| 181 | 15/16 A switch |
| 182 | 3 pin 5/6 A socket outlet |
| 183 | 6 pin 15/16 A socket outlet |
| 184 | Telephone socket outlet |
| 185 | TV antenna socket outlet |
| 186 | S/F 25 amp Air-Conditioner power plug point i/c 4 modules metal box on surface or in recess 4 modules plate and cover in front 25 amp modular starter 25 amp modular socket outlet and 25 amp plug i/c connection as reqd |
| 187 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 188 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.. |
| 189 | 1 or 2 Module (75 mmX75 mm) |
| 190 | 4 Module (125 mmX75 mm) |
| 191 | 6 Module (200 mmX75 mm) |
| 192 | 8 Module (125 mmX125 mm) |
| 193 | 12 Module (200 mmX150 mm) |
| 194 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 195 | Supplying and fixing brass batten/ angle holder including connections etc. as required. |
| 196 | S/F bell push modular type complete as reqd |
| 197 | SUB HEAD-II : MCCB, MCB & DB’S |
| 198 | Providing and fixing (following rating and breaking capacity) MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 199 | 4 Pole MCCB 315 amp 35 KA |
| 200 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 201 | 8 way, Double door |
| 202 | 12 way, Double door |
| 203 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 204 | Single pole |
| 205 | Providing and fixing following rating RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc as reqd |
| 206 | 63 amps 2 pole RCCB 100mA/300mA |
| 207 | SUB HEAD-III: RISING MAIN AND BUS TRUNKING |
| 208 | Providing and fixing ( following capacity TP & N) disconnector fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuses including drilling holes in the cubicle panel board making connections as required. |
| 209 | 100 A TPN |
| 210 | 200 A, TPN |
| 211 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) as reqd |
| 212 | Extra for using salt and charcoal for GI or copper plate earth electrode as reqd |
| 213 | SUB HEAD V:- NON DSR ITEM (ANALYSED MARKET RATE) |
| 214 | Supplying , Installation, testing and commissioning of LED Lamp (havell,s /Bajaja/Phillips/Cromton). Including connection etc. as required. |
| 215 | With CFL 12/15 Watts Lamp. |
| 216 | Supplying, Erection, testing and commissioning of (pre-wired) wall bracket/ceiling fittings of all sizes and shapes containingCFL/LED/W GLS lamps per fitting, complete with all accessories including connection etc. as required(havell,s /Bajaja/Phillips/Cromton). |
| 217 | Ceiling fitting (Surface) with 12/15 watt LED Lamp. |
| 218 | Supplying, Instaling, testing and commissioning of (pre-wired) bulk head fitting with glass complete containingLED lamps per fitting, complete with all accessories including connection etc. as required(havell,s /Bajaja/Phillips/Cromton). |
| 219 | With 7 Watts LED Lamp. |
| 220 | Supplying, Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.(havell,s /Bajaja/Phillips/Cromton). |
| 221 | 1200 mm sweep |
| 222 | Supplying, Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 223 | 225mm sweep |
| 224 | S/F 1.5 tone capacity split type Air Conditioner (Diamond 3 Star.5G 29 G-SC 18 FD3 WJH) complete with Indo voltage stabilizer Automatic 4 KVA (140-280 for 1.5 ton) |