Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 2 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil : 50 meter beyond 1 m from cutting edge |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. layers not exceeding 20cm in depth, consolidation each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 4 | Supplying and filling in plinth with fine sand underfloors including, watering, ramming consolidating and dressing complete. |
| 5 | Supplying & stacking of hard stone (for stone pitching) 22.5cm thick at site. |
| 6 | Dry stone pitching (any thickness) excluding cost of stones.On Horizontal |
| 7 | Providing and laying in positioncement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 9 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 3 ( 1 cement : 3 fine sand) |
| 10 | Providing and laying in position machine batched and machine mixed and machine vibrateddesign mix cement concrete of specified grade for reinforced cement concrete workbut excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.M-25 grade reinforced cement concrete by using 330 Kg cement per cum of concrete.All works upto floor fivelevel. Crushed stone aggregate |
| 11 | Centering and shuttering including strutting , propping etc. and removal of formfor : Foundations, footings, bases of columns etc. for mass concrete |
| 12 | Centering and shuttering including strutting , propping etc. and removal of formfor :Columns, pillars, piers, abutments, posts and struts |
| 13 | Centering and shuttering including strutting , propping etc. and removal of formfor : Suspended floors, roofs, landings, balconies and access platform |
| 14 | Centering and shuttering including strutting , propping etc. and removal of formfor : Lintels, beams, plinth beams, girders, bressumers and centilevers. |
| 15 | Centering and shuttering including strutting , propping etc. and removal of formfor Edge of slabs and breaks in floors and walls.Under 20cms wide |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth or above level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 17 | Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in : Cement mortar 1:6 (1 cement :6 coarse sand) |
| 18 | Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in : Cement mortar 1:6 (1 cement :6 coarse sand) + Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 19 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) + Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 20 | Providing and layingvitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conformingto IS: 15622 of approved make in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with whitecement and matching pigments etc., complete. Size of tile 600mm x 600mm |
| 21 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement.Size of Tile 600mm x 600 mm |
| 22 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent |
| 23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.66.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 24 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity Counters, window sills, facias and similar locations, ofrequired size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels- Granite of any colour or shade 16 mm(Area of slab over 0.5 sqm) |
| 25 | Providing edge moulding to 16/18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 26 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 27 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 28 | Providing and fixing Laminated wooden flooring including finishing in iron screws Complete. Branded 12 mmthick |
| 29 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately Chaar Phool |
| 30 | Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS: 13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. 9mm thickness |
| 31 | Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. Second class kail wood |
| 32 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per directionEngineer-in-charge : Second class kail wood |
| 33 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete2nd class KAIL wood 50mm x12mm |
| 34 | Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. includingISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws, |
| 35 | Providing and fixing Second class kail wood 35mm thickpanelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with providing includingISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws, (Shutter area to be measured).excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 36 | Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked including top cover of 6mm commercial ply wood conforming to IS :303 BWR grade, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100mm x 40mmx40 mm on both inner side of pelmet and rawl plugs 75mm long etc. all complete |
| 37 | Providing and fixing wooden designeddoor shutter as perrequirementand instruction of Engineer in charge). 32 mm thickness |
| 38 | Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with 6 levers and a pair of anodised ( anodic coating not less than grade AC 10 as per IS:1868) aluminium lever handles with necessary screws etc. complete (best make of approved quality) |
| 39 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc.complete. : 250x10 mm |
| 40 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc.complete. : 150x10 mm |
| 41 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 42 | Providing and fixing bright finished brass handles with screws etc. complete :125mm |
| 43 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 44 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive |
| 45 | Cement plaster in coarse sand .12mm cement plaster of mix 1:6 (1 cement :6 coarse sand) |
| 46 | Cement plaster in coarse sand 15mm cement plaster on the rough side of single or half brick wall of mix 1: 4(1 cement :6 coarse sand) |
| 47 | 6mm cement plaster to celling of mix 1:3(1 cement :3 fine sand) |
| 48 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 49 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 50 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 51 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 52 | Finishing walls with texturedexterior paint of required shade on new work (two or more coats applied @ 3.28 liter/ 10sqm over and including base coat of water proofing cement paint applied @2.20kg/10sqm |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 54 | Melamine polishing on wood work (one or more coats) |
| 55 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at everyjunction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto150mm on both sides of joint and two coats of primer suitable for board. |
| 56 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 57 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part-I : 2011 (Board with BIS certification marks) |
| 58 | Structural steel workwelded inbuilt up sections, trusses and framed work, including cutting, hoisting, fixing in position and applyinga rpimingcoat of approved steelprimer all complete. |
| 59 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 60 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required. |
| 61 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 62 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 63 | Providing and Fixing WARDROBES (60 cm deep) including 18mm Plywood All around, including Shelves and 12mm Ply for back Side Inner Area Finished With Liner, Outer Face of Shutters with Mica Finishing(1 mm), Concealed Cabinet Hinges, Cabinet Handles, Magnetic Catcher, 19mm Ply To Ply For Shutters, Hanger Rod, Drawer Locks, Mica Beading etc.of approved Brandswith necessary fittings all completeas per direction of Engineer in Charge. sizes- 2.4 mx 2.4 m |
| 64 | Providing and Fixing Modular Kitchen (HDHMR) including Bottle Pullout Basket, Plain Basket, Cutlery Basket, Thali Basket, Dish Rack(SS), Channels, Hinges etc.of approved Brandswith necessary fittings all completeas per direction of Engineer in Charge. (front area to be measured only). |
| 65 | Providing and laying 60mm thick factory made cement concreteinterlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 66 | Providing and fixing white vitreous china extended wall mounting Water Closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 6 litre (adjustable to8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 67 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 68 | Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board .510x1040 mm bowl depth 225 mm |
| 69 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe40 mm dia |
| 70 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 71 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 72 | Providing and fixing toilet paper holder : C.P. brass of standard size |
| 73 | Providingandfixing15mmnominalboreC.P.brassanglevalveforbasin mixer and geyser points of approved make conforming to IS : 8931, 15mm nominal bore |
| 74 | Providing and fixing brass bib cock of approved quality.15 mm nominal bore |
| 75 | Providing and fixing uplasticized PVC connection pipe with brass unions : 45 cm length,15 mm nominal bore |
| 76 | Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 77 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet, 100 mm diameter |
| 78 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 79 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. |
| 80 | Providing and fixing soil, waste and vent pipes.100 mm dia Centrifugally Cast (spun) Iron S&S pipe as per IS:3989. |
| 81 | Providing and fixing soil, waste and vent pipes. 75 mm dia Centrifugally Cast (spun) Iron S&S pipe as per IS:3989. |
| 82 | Providing and fixing M.S. holder bat-clamps of approved design to Sand Cast Iron / Cast Iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal sixe) including cost of cutting holes and making good the wall etc :For 100 mm dia. |
| 83 | Providing and fixing M.S. holder bat-clamps of approved design to Sand Cast Iron / Cast Iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal sixe) including cost of cutting holes and making good the wall etc :For 75 mm dia. |
| 84 | Providing and fixing MS stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter. For 100 mm dia pipe |
| 85 | Providing and fixing MS stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter. For 75 mm dia pipe |
| 86 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaSand cast iron S&S as per IS - 3989 |
| 87 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.75 mm diaSand cast iron S&S as per IS - 3989 |
| 88 | Providing and fixing plain bend of required degree.(IS 3989)100 mm dia Sand Cast Iron S&S as per IS:3989. |
| 89 | Providing and fixing plain bend of required degree.(IS 3989)75 mm dia Sand Cast Iron S&S as per IS:3989. |
| 90 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100 mm Sand Cast Iron S&S as per IS:3989. |
| 91 | Providing and fixing single equal plain junction of required degreewith access door, insertion rubber washer 3 mm thick, bolts and nuts complete.75x75x75 mm Sand Cast Iron S&S as per IS:3989. |
| 92 | Providing and fixing terminal guard 100 mm dia Sand Cast Iron S&S as per IS:3989. |
| 93 | Providing and fixing terminal guard 75 mm dia Sand Cast Iron S&S as per IS:3989. |
| 94 | Providing and fixing collar :100 mm Sand cast iron S&S as per IS -3989 |
| 95 | Providing and fixing collar :75 mm Sand cast iron S&S as per IS -3989 |
| 96 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm |
| 97 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :75 mm |
| 98 | Providing and fixing trap of self cleasing design with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 75 mm outlet Sand Cast Iron S&S as per IS:3989. |
| 99 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore (M) |
| 100 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore (M) |
| 101 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc.Internal work-Exposed on wall :25 mm dia nominal bore b) Medium |
| 102 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. Internal work-Exposed on wall :32 mm dia nominal bore b) Medium |
| 103 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work :50 mm dia nominal bore b) Medium |
| 104 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work :65 mm dia nominal bore b) Medium |
| 105 | Providing and fixing ball valve (brass) of approved quality,High or low pressure, with plastic floats complete, 20 mm nominal bore |
| 106 | ProvidingandfixinggunmetalgatevalvewithC.I.wheelofapprovedquality (screwed end)20 mm nominal bore |
| 107 | ProvidingandfixinggunmetalgatevalvewithC.I.wheelofapprovedquality (screwed end)25 mm nominal bore |
| 108 | Providing and placing on terrace (at all floor levels) polyethylene water storagetankISI:12701marked,withcoverandsuitablelockingarrangementandmakingnecessaryholesforinlet,outletandoverflowpipes but without fittings and the base support for tank |
| 109 | Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I. grating brick masonry chamber with water tight C.I. cover with frameof300x300mmsize(inside)theweightofcovertobenotlessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design |
| 110 | Providingandlayingcementconcrete1:5:10(1cement:5coarsesand:10gradedstoneaggregate40mmnominalsize)including bedconcreteas per standard design All around S.W. pipe 150 mm diameter S.W. pipe |
| 111 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarsesand(zone-III):3gradedstoneaggregate20mmnominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thickwithcementmortar1:3(1cement:3coarsesand)finishedwithfloatingcoatofneatcementandmakingchannelsincementconcrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20mmnominalsize)finishedwithafloatingcoatofneatcementcompleteasper standard design :Inside size 90x80 cm and 45 cm deep including C.I. coverwith frame(lightduty)455x610mminternaldimensions,totalweightofcoverandframetobenotlessthan38kg(weightofcover23kgandweight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 112 | Providing and fixing PTMT grating of approved quality and colour.Circular type, 125 mm nominal dia with 25 mm waste hole |
| 113 | Providing & fixing first quality white colour vitreous china oval / roundlavatory basin, approx size 550x410 mm for under counter mounting, with 15 mm C.P. brass Single lever basin mixer Specially fabricated C.I./M.S. brackets, painted with two or three coats of enamel paint of approved shade over a coat of primer,32 mm C.P. brass waste and C.P.brass cast brass bottle trap and pipe to wall with C.P. brass flange and rubber adopter for waste connection complete includingfilling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required. |
| 114 | Providing & fixing 15mm C.P. brass table mounted quarter turn Sink hot and cold Mixing fittingfor kitchen sink with swinging spout, 450 mm copper pipes and brass nuts complete including cutting & making good the walls where required. |
| 115 | Providing & fixing Wall Mixer with provision for connection to overhead shower with bend pipe for upper sidecomplete including cutting and making good the walls wherever required.Exposed Wall Mixer With Provision Only for Overhead Shower & Hand Shower with Connecting Legs & Wall Flanges) |
| 116 | Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. |
| 117 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100Amp, 30kA, MCCB |
| 118 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A. |
| 119 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A. |
| 120 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 250 mm X 60 mm deep |
| 121 | Supplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door |
| 122 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 123 | SupplyigandfixingoffollowingCopperBusBar Chamber on surface or in recess. 6 way 200 A |
| 124 | Supply of PVC sheathed pvc insulated XLPE armoured Aluminium conductor cable of size3.5 core 25 sqmm, 1100 V grade as per IS7098-Part I with latest ammendments. |
| 125 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm. |
| 126 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia |
| 127 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required. 50 mm dia |
| 128 | Supplying and making end termination with brass compression gland andaluminiumlugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28 mm) |
| 129 | Earthing with copper earth plate600mmX 600 mm X 3 mm thick including accessories, and providing masonry enclosure with coverplate having locking arrangementand wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 130 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 131 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 132 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 133 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required |
| 134 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 135 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 136 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 137 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 138 | Supplying and fixing followingmodularswitch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 139 | Supplying and fixing followingmodularswitch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 140 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Modules |
| 141 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Modules |
| 142 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.18 Modules |
| 143 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 144 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 Pin 5/6 A Socket Outlet |
| 145 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 146 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch(2 Module), connection etc. as required. |
| 147 | Supplying of 200mm Ventilating/Exhaust Fan Non Metalic Body White Colour |
| 148 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto450 mm sweep |
| 149 | Supplying of LED luminaire suitable for armstrong / grid ceiling alongwith driver 18W. |
| 150 | Supplying of Bracket LED light luminaire(18W or above). |
| 151 | Supplying of surface mounted decorative LED Downlight luminaire suitable for exterior wall lighting (10W or above). |
| 152 | Supplying of LED Post Top Lamp luminaire suitable for Boundary lighting (10W or above). |
| 153 | Supplying of LED Bed Side Lamp luminaire suitable for Reading (18W or above). |
| 154 | Supplying of LED Foot Lamp luminaire suitable for Night Walk (4 W or above). |
| 155 | Supplying ofdecorative LED luminaire suitable for mirror lighting (10W or above). |
| 156 | Installation, testing and commissioningofpre- wired, fluorescent fitting / compact fluorescent fitting/LED tube fittings of all types, complete with all accessories and tube etc. directlyonceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 157 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 158 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 159 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 160 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 161 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 162 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 163 | Supplying and fixing following size/modules,GI box alongwith modular base & cover plate for modular switches in recess etc as required. 2 Module |
| 164 | Supplying ofmodularswitch/ socket with modular plate & switch box including connections as required. LAN socket outlet RJ45 |
| 165 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 166 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV Antenna socket outlet |
| 167 | Supplying, installing, testing & commissioning of inteligent analouge photoelectric optical type smoke detector and mounting base with LED light complete as required. |
| 168 | Supplying, installing, testing & commissioning of single phase AC 220/250 V Speaker Hooter of size minimum 20 Cm dia suitable for wall mounted complete as required |
| 169 | Supplying, installing, testing & commissioning of Notifier manual call point in suitable enclosure with arrangement to raise the alaram and reset in original position complete as required. |
| 170 | Supplying, installing, testing & commissioning of microprocessor based main fire alarm control panel, operating on AC 220V, 2 zone capacity wall mounted complete with inbuilt batteries, battery charger complete as required. |
| 171 | Supplying of Cable for Dish TV (RG-6) |
| 172 | Supplying of Ceiling Fans, Double Ball Bearing, 1200mm Sweep (5 Star) with Electronic Regulator |
| 173 | Supplying, installation,testingandcommissioning of Geyser of 25 Ltr. Capacity (5 Star) alongwith 15/16 A plug top and connecting pipe. |
| 174 | Supplying of Oil Filled Heat Radiator equipped with thermostat for over heat protection, minimum 13 Wave Fins, 2900 watt |
| 175 | Supplying, installation,testingandcommissioning of Split Type Hot & Cold Air Conditioners, 1.5 Ton, Wall Mounted (5 Star) |
| 176 | Supplying of Stabilizer for AC min. 4kVA or above. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail