| Sl. No. | Item Description |
| 1 | PART -I -ADDN/ALTN/IMP IN AIRMEN BILLET TO ACCOMMODATE AGNIVEERVAYU (WOMEN) |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed. |
| 3 | Dismantling of Stone slab and tiles laid bedded and pointed in any mortar of any description or thickness in floors, apron etc complete all as specified and directed. |
| 4 | M&L for Demolition of un-reinforced cement concrete as in of any description and any in position not otherwise specifically provided complete all as directed |
| 5 | M&L for Demolition Cement concrete concrete (unreinforced concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | Taking down plastering on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc etc complete all as directed |
| 7 | Taking down chowkhats or frames with shutters and (without taking off shutters from frames) n.exc 1.5 sq. m each complete all as specified and directed. |
| 8 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each all as speciffied and directed |
| 9 | Taking up or down steel tubing and connections, including removal to store for 15mm bore complete all as specified and directed. |
| 10 | All as item No. 8.00 above but for 20mm bore complete all as specified and directed. |
| 11 | All as item No.8.00 above but for 25mm bore complete all as specified and directed. |
| 12 | Taking down PVC pipes / (any pipe of any size) or pattern incl all fittings, head shoes, bends swan necks etc including cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories) complete all as directed. |
| 13 | Demolition of stones or brick masonry or block walling, built in cement mortar including all quoins, arches etc., but excluding ashlar facing, dressed stone work etc.complete including removal of debris to a distance exc 1.5 km but n.exc 2 Km, all as specified and as directed. |
| 14 | M&L for Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed. |
| 15 | M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built incement mortar 1:4 (01 cement : 04 coarse sand) all as specified & directed. |
| 16 | M &L Rendering 10 mm thick on fair faces of brick or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement (Internal surfaces) all as specified and directed. |
| 17 | M&L for Rendering cement plaster 10mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on ceiling, surface finished even and smooth without using extra cement,complete all as specified and directed. |
| 18 | M&L for Preparation of new plastered or unplastered surfaces of walls and applying applying two coats of oil emulsion distemper over a coat of alkali resistant primer including 3mm thick wall care puttycomplete all as specified and directed. |
| 19 | M&L for Preparation of new plastered or unplastered surfaces and applying two coats of Oil Bound distemper over a coat of primeron ceiling complete all as specified and directed. |
| 20 | M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall and preparation of plastered surface of walls and applying applying two coats of oil emulsion distemper over a coat of alkali resistant primer including 3mm thic wall care puttyfor smooth surface complete all as specified and as directed. complete all as specified and directed . |
| 21 | M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall and preparation of plastered surface of walls and applying two coats of oil bound distemper over primer on ceilingfor smooth surface complete all as specified and as directed. complete all as specified and directed. |
| 22 | M&L for Non-skid ceramic coloured tiles7 to 8mmthick (square / rectangular) area of each tile exceeding 0.06 square metre but not exceeding 0.11 square metre, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B1 quality over cement screed 1:4, 15mm thick applied with cement slurry at the rate of 3 kg / square metre complete all as specified and as directed. |
| 23 | M&L for Vitrified ceramic coloured tiles, light shade, 10mm thick (square / rectangular) polished, area of each tile exceeding 0.36 square metrebut not exceeding 0.42 square metre in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over cement screed 1:4, 15mm thick applied with cement slurry at the rate of 3 kg / square metre complete all as specified and as directed. |
| 24 | M&L for Vitrified ceramic coloured tiles, light shade, 10mm thick (square / rectangular) polished, area of each tile exceeding 0.36 square metrebut not exceeding 0.42 square metre in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:4. 10mm thick complete all as specified and as directed. |
| 25 | M&L for Non ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar 1:6 (01 cement : 6 coarse sand) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 26 | M &L for 25mm thickPCC 1:2:4 type B-0 (using 12.50 mm stone aggregate) as in levelling courseall as specified and directed. |
| 27 | Glazed ceramic tiles coloured of size 350mm x 250mm/ 450mm x 350mm / 300 x 450mmminimum 7mm thickin vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:4. 10mm thick complete all as specified and as directed. |
| 28 | S&F Coloured Glazedtiles 300x200x7mm thick, on walls/verticaletc. set & jointed in neat cement slurry & pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) on fair face of brick or concrete surface complete all as specified and as directed. |
| 29 | M & L 18-20mm thick Granite (of any type) work (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed. |
| 30 | Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed |
| 31 | Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc including taking down or and making good of disturbed surface all as specified below complete all as specified and directed. (a) Frame(top & side)section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm(Section No 19584)(f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370). |
| 32 | S&F Aluminium die cast body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and directed. |
| 33 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position all as specified and directed. |
| 34 | Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) partition wall, partly glazed with 5.50 mm thick tinted glass and partly panlled with 9 mm thick prelaminated particle board with both side decorative laminatied including rubber bead joining cleat for fixing in position etc all as specified below complete all as specified and directed. (a) Outer member top & verticle section shall of size 101.60 x 44.45 x 2.5 mm ( Section No 20102) (b) Middle member top & verticle section shall of size 101.60 x 44.45 x 2.5 mm ( Section No 20057) (f) Glazing clip for securing glass / panel shall be be of 0.80 mm thick (Section No 19370). Make- Jinal Section, |
| 35 | Supply, fabricate and fixing in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) ventilator, partially glazed and partially louvers, outer frame & mullionfabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.50 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portion louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti including S.S wire gauge of fixing of 0.36mm dia and 1.40 width of aperture with 25x3mm think aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position all as specified and directed. Note for Serial Item Nos 33 to 35:- (i) Section No given above are of Make-Jindal and are for guide line. (ii) The measurements shall be taken actual at site, any wastage shall be included in the rates quoted. |
| 36 | S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,framework of water tanks and similar work conforming to Fe 290 Grade E-165 |
| 37 | Forming jambs, etc to openings including cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work complete in cement mortar 1:4 |
| 38 | Making good under cills or over arches lintels and bressummers including all pinning when necessary complete in cement mortar 1:4 |
| 39 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm thick MS square tube of 19 gauge mitre cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mmx15mm MS squaretube inside the 19mm MS square tube and suitably screwed complete all as specified and as directed. |
| 40 | Supply & fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail & bottom rail Paneling plain colour PVC sheet to be fitted in MS frame welded/sealed to the stile & rails with suitable PVC sheet beading as per specification & shown on drawing in SSRPt II of 2020 complete all as specified. |
| 41 | S&F 75mm size type C21 Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised complete all as specified and as directed |
| 42 | S&F aluminium handle 150 mm cast type anodized complete all as specified and as directed |
| 43 | S & F aluminium anodized tower bolt 150mm size complete all as specified and directed. |
| 44 | S&F roller blind with aluminium powder coated channel & PVC runners and fabric blinds fixed to window as per manufacture instruction complete all as specified and directed. |
| 45 | Supply and fix vertical blind with aluminium powder coated channel & PVC runners and fabric blinds fixed to window as per manufacture instruction complete as per sample kept in GE\"s office including taking down old vertical blind all as specified and directed. |
| 46 | Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complet all as specified and directed. |
| 47 | S&F in repair for Harrison Curtain rails 25mm dia, mild steel, chromium plated with fixing brackets, stops, rollers etc.in repair all as specified and as directed. |
| 48 | S&F Powder Coating(minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 49 | S&F for Sheet glass 5.5mm thick , selected quality and glazing with oil putty in squareexc 0.5 sq. m in each pane etc. complete all as specified and directed |
| 50 | S&F for Solar control film 25 micron reflective type (gareware sun control or equivalent) complete all as specified and directed |
| 51 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stain less steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction . |
| 52 | S&F for 18/19 thick Prelaminated particle board, interior grade,prelaminated both sides with decorative choice laminationsfixed with screws totimber frame worketc. complete all as specified and directed |
| 53 | M&L for Iind class Plain fillets. square, rectangular or triangular in exc 3 sqcm n.exc 6 sqcm section, clean sawn, secured with nails or bradsetc. complete all as specified and directed |
| 54 | S&F in repair for 4mm thick dia Plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc.complete all as specified and as directed |
| 55 | S&F for 52mm thick PVC Partition consisting of 12mm thick plain solidPVC ply sheet reinforced with frame work made from 40mm x 20mm MS tubes. In between two MS tubes, 5mm thick Plain heat mouldedChannel of size 75mmx50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply opanel shall be inserted in the PVC \"C channel.The first & last MS tube should be errected such that it is inside a PVC\"C\" channel, in between adjoining plastic panel, 5mm thick x75mmwidth plain PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete all as specified and directed. |
| 56 | S&F Unplasticised PVC pipes and fittings of 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 57 | S&F Unplasticised PVC pipes and fittings of 20mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 58 | S&F Unplasticised PVC pipes and fittings of 25mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 59 | M&L for Cutting chases or making holes in brick walls for concealed watertubing, making good to facings where required, cutting not exc 10 cm girth all as specified and directed. |
| 60 | S & F in repairs Vitreous china water closet pan (pedestal pattern), white including fixing bolts, plastic water closet seat, black/white closed pattern with flat bottom and cover and mild steel chromium plated hinging device complete all as specified and directed. |
| 61 | S&F for Vitreous China squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, snow white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc and making good to floors to match existing, in repairs, all as specified and directed. |
| 62 | S & F in repairs PVC valve less flushing cistern syphonic action type, low level, inlet, ball valve, float & handle 10 litre capacity including brackets, flush pipe and all accessories all as directed. |
| 63 | S & F in repairs of 2-in-1 faucet with 1.5m tube and hook all as directed. |
| 64 | S&F in repair vitreous china wash basin (WHB) , white , flat back , size 550 mm x 400 mmexcluding supply of taps,but includingwaste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and flt nuts , flange end embedded in red lead cement and other end fixed , chain and plug and porcelain stopper and brackets including cutting for and pinning in ends of brackets or erecting stand ,making connections to waste and supply pipes andcomplete all as specified and directed |
| 65 | S & F in repair vitreous chinaurinal half stall urinal type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including60mm long brass screws pointing around urinal back in cement complete all as directed. |
| 66 | S&F in repairs 15 mm dia Bib taps,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for PVC/ iron pipe or for brass ferrule and fixed complete all as specified amd directed |
| 67 | S&F in repairs 15mm dia stop valve/Angle valve, chromium plated fancy type cast copper alloy, screwed down high pressure, with crutch or butter fly handle, screwed both ends for PVC/iron pipes or for unions and fixed of,complete all as specified and directed. |
| 68 | S&Fin repairs pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or cold with long screwed shanks and flynuts, scewed for union pipe and fixed to 15mm dia pipe. |
| 69 | S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor, of 110 mm dia complete all as specified and directed. |
| 70 | S&F PVC (SWR)bends110mm dia of any radius with access door complete all as specified and directed. |
| 71 | S&F PVC (SWR) branch piece, single (Y)equal or unequal110 mm bore with access door complete all as specified and directed. |
| 72 | S&F 75 mm bore PVC ( SWR) pipes ofsingle socketed in any length with rubber ring joints fixed to floor all as specified |
| 73 | S&F 75 mm bore. PVC (SWR) bends complete all as specified and directed. |
| 74 | S&F PVC (SWR) Gully trap 125/110mm setting and jointing with solvent cement complete all as specified and directed |
| 75 | S&F in repairs tubular towel rail brass chromium plated, 20mm dia, complete all as specified & directed |
| 76 | S&Fbrass CP two way bib tap of 15mm dia chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for PVC/ iron pipe or for brass ferrule and fixed complete all as specified amd directed . |
| 77 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, all as specified and directed. |
| 78 | S & F PVC connections 15mm size with PTMT nuts of length 600 mm,complete all as specified and directed. |
| 79 | S&F in repair 500ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl taking down oldall as specified and directed |
| 80 | S&F in repair 1000ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl taking down oldall as specified and directed |
| 81 | S&F Ball valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore (Minimum weight 455 gms )and fixed complete all as specified and directed. |
| 82 | S & F in repairs600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 83 | S&F in repairs Stainless steel Soap dishfixed to wall all as specified and directed |
| 84 | S&F for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed. |
| 85 | M&L for PCC 1:3:6 type C2 (40mm graded Stone aggregate) as in foundation of post holes filling and mass concrete all as specified and directed. |
| 86 | M & L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides;fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 87 | M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated Fe 410 -W (Gde- E- 250) quality A all as specified and directed. |
| 88 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly prepared steel surfaces over 10cm in width or girth not otherwise described all as specified and directed. |
| 89 | Supply & Fix 06 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories complete all as specified and as per manufacturer\"s instructions all as specified and directed. |
| 90 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 91 | Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulatedFRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision ofone 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly,including steelbox of required module for modular switches/sockets and regulators all as specified complete Note : Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 92 | one light point controlled by one switch. |
| 93 | One ceiling fan point controlled by one switch and regulator |
| 94 | One Exhaust fan point controlled by one switch. |
| 95 | One switch socket outlet 3 pin 5 Amps on same board along with other switches |
| 96 | One switch socket outlet 3 pin 5 Amps on independent board. |
| 97 | All as per item No 90.00 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulatedsingle coremultistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board and industrial socket complete all as specified and as directed. |
| 98 | M&L Pointing wiring in Existing conduit with 1.5 Sqmm (nominal area) PVC insulated,(FRLSH) unsheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existingPVC/ steel heavy duty conduit 20 mm diaconduit including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, replaced with 1.6 mm thick MS terminal box finished to wall & 3 mm thick laminated hylam sheet top coverfor one light/fan/Bell/5 Amp socket all as specifiedand directed. |
| 99 | M&L Pointing wiring in Existing conduit with 4 Sqmm (nominal area) PVC insulated,(FRLSH) unsheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existingPVC/ steel heavy duty conduit 20 mm diaconduit including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, replaced with 1.6 mm thick MS terminal box finished to wall & 3 mm thick laminated hylam sheet top coverfor 15Amps socket all as specifiedand directed. |
| 100 | M&L for replacement oflaminated hylam sheet top cover with brass screws, cup wahser suitable for 03/04 modules concealed box and cutting of grooves for switchs,sockets and regulator etc complete all as specified and directed.(Note: 1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Switch,sockets,regulators to be measured and paid separately) |
| 101 | All as per above item No.94.00 description but 06 to 10 modules complete all as specified and directed. |
| 102 | All as per above item No. 94.00 description but 18 to 24 modules complete all as specified and directed. |
| 103 | S&F Switch piano flush type, single pole,5 Amps, 240 volts complete all as specified and directed. |
| 104 | S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all as specified and directed. |
| 105 | S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all as specified and directed. |
| 106 | S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all as specified and directed. |
| 107 | S&F electronic fan regulator, flush type phenolic laminated sheet etc; as required all as specified and directed. |
| 108 | Taking down carefully Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 2/3 runs of 6 Sq.mm removing materials from site, taken ascredit ,making good thedisturbed surfaces all as specifiedand as directed. |
| 109 | Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmmconforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistrandedcopper conductorcable (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly complete all as specified and as directed. |
| 110 | S&F MCB DB SPN 8 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer andSP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incomingand Outgoing MCB measured separately relevent items. |
| 111 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 112 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amps, in the MCB DBcomplete with connection testing and commissioning complete all as specified and directed. |
| 113 | S&F in replacement ofSurface and wall mounted LED tube light fitting, 20 W, batten type,PC housing provided for efficient heat dissipation with polycarbonate diffuser andintegrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed. |
| 114 | Taking down unserviceable ceiling fan from site and re-fixing in position duly rectifying the defects (replacing of ball and bearing, oiling / greasing,winding etc.) and make it serviceable in all respect including painting and marking MES No complete all as specified and as directed . |
| 115 | Supply & fix ceiling fans ceiling BLDC type complete with accessories 230 V,1400 mm sweep. BEE 5 star rated with provn of necesary hanging hook on ceiling complete all as specified and directed. |
| 116 | S&F of Exhaustfan, heavy duty, 300mm sweep, 1370 RPM, with louvers, metal body conforming to IS-2312-1967, AC singlephase, 240 Volts, 50 Hzand connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 117 | Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed |
| 118 | Earthing complete with galvanised iron earth plate electrode 600mm X600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of MES Sch Part-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal,lugs including testing complete all as specified and as directed. |
| 119 | PART II-PROVN OF CYCLE PARKING SHED FOR 1349 DSC PLATOON . |
| 120 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard / dense soil complete all as specified and directed. |
| 121 | Excavating in post holes each not exc 0.5 Cum getting out hard and dense soil,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface all as specified and directed. |
| 122 | M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate in bed plates in foundations etc.all as specified and directed. |
| 123 | Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified and directed. |
| 124 | S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W (Gde-E-250) quality ‘A’ complete all as specified and as directed. |
| 125 | M&L Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thickof an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws all as specified and directed. |
| 126 | M&L Pre painted galvalume aluminium zinc coating GI based plain steel sheet in ridges 0.50mm thickof an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws all as specified and directed. |
| 127 | M & LPreparation of new steel surfaces over 10cm width or girth and priming with red oxide primer and painting with synthetic enamel painting two coats all as specified and directed. |
| 128 | Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 129 | Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate)as in sub base floor 100mm thick etc all as specified and directed. |
| 130 | Chequered tiles 30cm x30cm x25mm thick set and jointedand pointed in neat in floors over and including 20mm thick screed bed in CM 1:4 bedded and jointed in grey cement slurry with pigment all as specified and directed. |
| 131 | M&L Brick work with fly ash bricks, straight or curved on plan exc 6m radius built in CM 1:6 complete all as specified and directed. |
| 132 | M&L Rendering in CM 1:6 10 mm thick on brick work surfaces to be finished even and smooth without using extra cement complete all as specified and directed. |
| 133 | M&L Preparation of newly plastered surfaces of wall and applying three coats of white washing complete all as specified and directed. |
| 134 | Supply and fix Water heater storage type, electric, capacity 25 litres, BEE 5 star rated (incl inlet, out let pipes), adjustable thermostat, Efficient long-life copper heating element, Shock-resistant and rust-proof engineering, thermoplastic body, IPX4 waterproof technology, tank designed to withstand 8 bar pressure, tank marine grade glass line coated,PUF insulation, Magnesium anode complete with all fixing arrangements all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail