| 1 | Earth Work in Excavation in foundation in Kankar mixed soil . Including all materials, labours, T&P etc required for proper completion of work as per direction of Engineer in charge. |
| 2 | Cement Concrete with 40mm gauge Stone ballast, fine sand of 1.25 FM and Cement in proportion of 8:4:1 including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 3 | Rcc work with 20mm gauge stone grit, coarse sand and Cement in proportion of 3:1.5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work.Column |
| 4 | Rcc work with 20mm gauge stone grit, coarse sand and Cement in proportion of 3:1.5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 5 | Rcc work with 20mm gauge stone grit, coarse sand and Cement in proportion of 3:1.5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work. Lintel Beam |
| 6 | Rcc work with 20mm gauge stone grit, coarse sand and Cement in proportion of 3:1.5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work.T Beam |
| 7 | Rcc work with 20mm gauge stone grit, coarse sand and Cement in proportion of 3:1.5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work. Slab |
| 8 | M/S or iron work in plain work such as reinforcement . including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 9 | Class -150 Brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 10 | Class -150 Brick work in 1:6 cement and coarse sand mortar in Super Structure including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 11 | 12 mm thick plaster On Smooth Surface in 1:6 with cement fine sand including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 12 | 15 mm thick plaster on Rough Surface in 1:4 with cement fine sand including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 13 | Providing and fixing in position MS Grill with Shutter for Window, Ventilator . including supply of all materials, labour and T&P etc. required for proper completion of the work. ( SI New Item 3 ) |
| 14 | Painting of Doors and Windows including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 15 | Finishing of Wall with water proof cement paint including supply of all materials, labour and T&P etc. required for proper completion of the work. SI 660+661 Out Side Painting |
| 16 | One priming coat and two coat Oil Distemper on new work In Side of Building including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 17 | Providing and applying Plaster of Paris Putty of 2 mm thick over plastered surface to prepare the surface even and smooth ,including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 18 | 25 mm Cement Concrete Flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate of size 12.5 mm and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips.(excluding cost of glass strip). |
| 19 | Providing and Laying 8 to 10 mm thick Ivory or light shade Vitrified Tiles of 600x600mm size in Flooring and Skirting laid with base of cement sand mortar (1:3) laid and jointed with cement . including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 20 | Supply and fixing of PVC Pipe of approved quality for 110 mm dia as per Item. |
| 21 | Supply and fixing of Sign board |
| 22 | Wiring point for Light with 1.5 sq mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy duty PVC conduit pipe cancealed in the wall complete as earthwire drawn inside the conduit with modular type switch . Including all materials , labour T&P etc required for proper complition of work. SI 131 C + 187 C |
| 23 | Wiring point for Fan with 1.5 sq mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy duty PVC conduit pipe cancealed in the wall complete as earthwire drawn inside the conduit with modular type switch . Including all materials , labour T&P etc required for proper complition of work. SI 133 C + 187 C |
| 24 | Wiring point for Plug with 1.5 sq mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy duty PVC conduit pipe cancealed in the wall complete as earthwire drawn inside the conduit with modular type switch . Including all materials , labour T&P etc required for proper complition of work. SI 134 C + 187 C |
| 25 | S/F of Power Plug with 20A/250Volt flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed M.S. box . Including all materials , labour T&P etc required for proper complition of work. SI 1139 A |
| 26 | Supply and Wiring of Submain with two number 2.5 sq mm FRLSH PVC insulated 1100 V grade multi strand (M/S) single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit concealed in wall complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1304 C |
| 27 | S/F of 6 Amp to 32 Amp SPMCB (10KA) C curve complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1002 , CAT A |
| 28 | S/F of LED Tube Light with metal heavy duty box type batten light fitting 1x22 Watt suitable for up to 1x22 watt LED Polycabonate tube light complete including tube complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1413 CAT - AA |
| 29 | S/F of Surface / flush mounting 12 way SPN Distribution board with additional metal door without MCB (Miniature Circuit Breaker) complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1025 A , CAT A |
| 30 | S/F of Ceiling Fans with fan motor of A.C. Permanent insulation , capacitor rating conferming BEE 5 Star rating 1200 mm sweep complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1501 (i) |
| 31 | S/F of electronic Fan Regulator 120-280 V ISI marked on existing switch board including making connection complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1203 (A) |
| 32 | Erection and Testing of Ceiling Fans and Regulator etc excluding supply of down rod complete in all respect . Including all materials , labour T&P etc required for proper complition of work. SI 1115 Please Enable Macros to View BoQ information |