| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 2 | a) Of area 3 sq. metres and below |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | a) All kinds of soil. |
| 5 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 6 | a) Second class teak wood |
| 7 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) a) Second class teak wood |
| 8 | a) 30 mm thick shutters |
| 9 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 10 | a) Second class teak wood |
| 11 | Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. |
| 12 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/rubbish to the nearest municipal dumping ground, all complete as per directions of Engineer-In-Charge. |
| 13 | a) For door/ window/ clerestory window. |
| 14 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : a) Kitchen sink with drain board |
| 15 | (i)510x1040 mm bowl depth 200 mm. |
| 16 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 17 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 18 | a) Rectangular shape 453x357 mm |
| 19 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 20 | a) 25 mm nominal bore, 152 mm long. Weighing not less than 440 gms. |
| 21 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 22 | a) 25mm nominal bore. Weighing not less than 62 gms. |
| 23 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black), comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. (minimum). Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 24 | a) With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 26 | a)For fixed portioni) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 27 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 28 | a) Pre-laminated particle board with decorative lamination on both sides. |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 30 | a) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 31 | Removing aluminium partition including dismembering of all members like Aluminium pipes, channels, panel board, glass, grills, etc and stacking properly etc. complete as directed by Engineer in charge. |
| 32 | Refixing / erecting of aluminium partition using available aluminium pipes, door verticals door bottoms, galzing clips, channels, glass panels, particle boards etc. with proper care and precautions and with out any breakage etc including all necessary fixtures and fittings etc. completed as directed by Engineer -in-charge. (Note: EPDM rubber gasket and Aluminium snap beading shall be paid separately). |
| 33 | Transportation of dismantled Chowkat, Dismantled Aluminium Partition Materials upto Civil Division Store at Type IV Sqtrs and stacking the same neatly as per the direction of the Engineer in Charge. |
| 34 | Providing and fixing PTMT lever valve of approved quality and colour. |
| 35 | a) 25 mm nominal bore, 100 mm long. Weighing not less than 110 gms. |
| 36 | b) 40 mm nominal bore, 125 mm long. Weighing not less than 200 gms. |
| 37 | Providing and fixing PTMT union of approved quality and colour. |
| 38 | a) 25 mm nominal bore, 75 mm long. Weighing not less than 90 gms. |
| 39 | b) 40 mm nominal bore, 100 mm long. Weighing not less than 120 gms. |
| 40 | Constructing brick masonry Manhole chamber 60x60x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 600x600 mm FRP coverwith frame complete as per standard design : |
| 41 | a)With common burnt clay F.P.S. (non modular) bricks of class designation 3.5 |
| 42 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 43 | a) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 44 | Finishing walls with water proofing cement paint of required shade : |
| 45 | a)Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 47 | a)One or more coats on old work. |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 49 | a)Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |